BACKGROUND AND AIMS: Entropy monitoring entails measurement of the effect of anesthetic on its target organ rather than merely the concentration of anesthetic in the brain (indicated by alveolar concentration based on which minimum alveolar concentration [MAC] is displayed). We proposed this prospective randomised study to evaluate the effect of entropy monitoring on isoflurane consumption and anesthesia recovery period. MATERIAL AND METHODS: Sixty patients undergoing total abdominal hysterectomy under general anesthesia using an endotracheal tube were enrolled in either clinical practice (CP) or entropy (E) group. In group CP, isoflurane was titrated as per clinical parameters and MAC values, while in Group E, it was titrated to entropy values between 40 and 60. Data including demographics, vital parameters, alveolar isoflurane concentration, MAC values, entropy values, and recovery profile were recorded in both groups. RESULTS: Demographic data and duration of surgery were comparable. Time to eye opening on command and time to extubation (mean ± standard deviation) were significantly shorter, in Group E (6.6 ± 3.66 and 7.27 ± 4.059 min) as compared to Group CP (9.77 ± 5.88 and 11.63 ± 6.90 min), respectively. Mean isoflurane consumption (ml/h) was 10.81 ± 2.08 in Group E and 11.45 ± 2.24 in Group CP and was not significantly different between the groups. Time to readiness to recovery room discharge and postanesthesia recovery scores were also same in both groups. CONCLUSION: Use of entropy monitoring does not change the amount of isoflurane consumed during maintenance of anesthesia or result in clinically significant faster recovery.

2.
J Anaesthesiol Clin Pharmacol ; 33(3): 359-364, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29109636

RESUMO

BACKGROUND AND AIMS: The Airtraq™ video laryngoscope facilitates tracheal intubations in patients with difficult airway or cervical spine immobilization. However, curved reinforced tracheal tube and straight reinforced tracheal tubes are useful where neck of the patient is likely to be moved or flexed or if patient is in prone position, wherein nonreinforced endotracheal tube (ETT) might get kinked and/or compressed. We compared intubation success rate of curved and straight reinforced tracheal tubes with polyvinyl chloride (PVC) tracheal tube using Airtaq™ laryngoscope in paralyzed and anesthetized patients. MATERIAL AND METHODS: Totally, 120 patients underwent random allocation to one of the three groups using computer-generated randomization table. Patients were intubated with appropriate size and type of ETT using Airtraq™ after obtaining optimal glottis view. Experienced anesthesiologist performed endotracheal intubation and unblinded observer noted down success and ease of intubation. RESULTS: Patients intubated with PVC tube (100%) had higher rates of successful intubation and shorter intubation time (4 s), in comparison to intubation with curved reinforced (92.5%) and straight reinforced tubes (SRTs) (85%) using Airtraq™ laryngoscope (AL). However, there was no statistical difference in the incidence of airway trauma among all the three groups. CONCLUSIONS: PVC tracheal tube is significantly superior to both curved and SRTs for intubation using AL.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA