1.
Proc Natl Acad Sci U S A ; 119(16): e2107393119, 2022 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-35412903

RESUMO

Understanding the climatic drivers of environmental variability (EV) during the Plio-Pleistocene and EV's influence on mammalian macroevolution are two outstanding foci of research in African paleoclimatology and evolutionary biology. The potential effects of EV are especially relevant for testing the variability selection hypothesis, which predicts a positive relationship between EV and speciation and extinction rates in fossil mammals. Addressing these questions is stymied, however, by 1) a lack of multiple comparable EV records of sufficient temporal resolution and duration, and 2) the incompleteness of the mammalian fossil record. Here, we first compile a composite history of Pan-African EV spanning the Plio-Pleistocene, which allows us to explore which climatic variables influenced EV. We find that EV exhibits 1) a long-term trend of increasing variability since ∼3.7 Ma, coincident with rising variability in global ice volume and sea surface temperatures around Africa, and 2) a 400-ky frequency correlated with seasonal insolation variability. We then estimate speciation and extinction rates for fossil mammals from eastern Africa using a method that accounts for sampling variation. We find no statistically significant relationship between EV and estimated speciation or extinction rates across multiple spatial scales. These findings are inconsistent with the variability selection hypothesis as applied to macroevolutionary processes.


Assuntos
Evolução Biológica , Clima , Extinção Biológica , Especiação Genética , Hominidae , África , Animais , Fósseis , Hominidae/genética
2.
Eur Radiol ; 29(9): 4783-4793, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30805703

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of a modified three-material decomposition calcium subtraction (CS) algorithm for the detection of arterial stenosis in dual-energy CT angiography (DE-CTA) of the lower extremity runoff compared to standard image reconstruction, using digital subtraction angiography (DSA) as the reference standard. METHODS: Eighty-eight patients (53 males; mean age, 65.9 ± 11 years) with suspected peripheral arterial disease (PAD) who had undergone a DE-CTA examination of the lower extremity runoff between May 2014 and May 2015 were included in this IRB-approved, HIPAA-compliant retrospective study. Standard linearly blended and CS images were reconstructed and vascular contrast-to-noise ratios (CNR) were calculated. Two independent observers assessed subjective image quality using a 5-point Likert scale. Diagnostic accuracy for ≥ 50% stenosis detection was analyzed in a subgroup of 45 patients who had undergone additional DSA. Diagnostic accuracy parameters were estimated with a random-effects logistic regression analysis and compared using generalized estimating equations. RESULTS: CS datasets showed higher CNR (15.3 ± 7.3) compared to standard reconstructions (13.5 ± 6.5, p < 0.001). Both reconstructions showed comparable qualitative image quality scores (CS, 4.64; standard, 4.57; p = 0.220). Diagnostic accuracy (sensitivity, specificity, positive and negative predictive values) for CS reconstructions was 96.5% (97.5%, 95.6%, 90.9%, 98.1) and 93.1% (98.8%, 90.4%, 82.3%, 99.1%) for standard images. CONCLUSIONS: A modified three-material decomposition CS algorithm provides increased vascular CNR, equivalent qualitative image quality, and greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff on DE-CTA compared with standard image reconstruction. KEY POINTS: • Calcified plaques may lead to overestimation of stenosis severity and false positive results, requiring additional invasive digital subtraction angiography (DSA). • A modified three-material decomposition algorithm for calcium subtraction provides greater diagnostic accuracy for the detection of significant arterial stenosis of the lower extremity runoff compared with standard image reconstruction. • The application of this algorithm in patients with heavily calcified vessels may be helpful to potentially reduce inconclusive CT angiography examinations and the need for subsequent invasive DSA.


Assuntos
Angiografia Digital/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Extremidade Inferior/irrigação sanguínea , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Calcificação Vascular/diagnóstico por imagem
3.
Radiology ; 288(1): 64-72, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29634438

RESUMO

Purpose To compare two technical approaches for determination of coronary computed tomography (CT) angiography-derived fractional flow reserve (FFR)-FFR derived from coronary CT angiography based on computational fluid dynamics (hereafter, FFRCFD) and FFR derived from coronary CT angiography based on machine learning algorithm (hereafter, FFRML)-against coronary CT angiography and quantitative coronary angiography (QCA). Materials and Methods A total of 85 patients (mean age, 62 years ± 11 [standard deviation]; 62% men) who had undergone coronary CT angiography followed by invasive FFR were included in this single-center retrospective study. FFR values were derived on-site from coronary CT angiography data sets by using both FFRCFD and FFRML. The performance of both techniques for detecting lesion-specific ischemia was compared against visual stenosis grading at coronary CT angiography, QCA, and invasive FFR as the reference standard. Results On a per-lesion and per-patient level, FFRML showed a sensitivity of 79% and 90% and a specificity of 94% and 95%, respectively, for detecting lesion-specific ischemia. Meanwhile, FFRCFD resulted in a sensitivity of 79% and 89% and a specificity of 93% and 93%, respectively, on a per-lesion and per-patient basis (P = .86 and P = .92). On a per-lesion level, the area under the receiver operating characteristics curve (AUC) of 0.89 for FFRML and 0.89 for FFRCFD showed significantly higher discriminatory power for detecting lesion-specific ischemia compared with that of coronary CT angiography (AUC, 0.61) and QCA (AUC, 0.69) (all P < .0001). Also, on a per-patient level, FFRML (AUC, 0.91) and FFRCFD (AUC, 0.91) performed significantly better than did coronary CT angiography (AUC, 0.65) and QCA (AUC, 0.68) (all P < .0001). Processing time for FFRML was significantly shorter compared with that of FFRCFD (40.5 minutes ± 6.3 vs 43.4 minutes ± 7.1; P = .042). Conclusion The FFRML algorithm performs equally in detecting lesion-specific ischemia when compared with the FFRCFD approach. Both methods outperform accuracy of coronary CT angiography and QCA in the detection of flow-limiting stenosis.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Aprendizado de Máquina , Algoritmos , Feminino , Hemodinâmica , Humanos , Hidrodinâmica , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
AJR Am J Roentgenol ; 204(1): 92-7, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25539242

RESUMO

OBJECTIVE: The objective of our study was to show the feasibility of distinguishing between uric acid (UA) and non-UA renal stones using two consecutive spatially registered low- and high-energy scans acquired on a conventional CT system. SUBJECTS AND METHODS: A total of 33 patients undergoing clinically indicated dual-source dual-energy CT examinations to differentiate UA from non-UA renal stones were enrolled in this study. Immediately after patients underwent clinically indicated dual-source dual-energy CT, two consecutive scans (one at 80 kV and one at 140 kV) were obtained on a conventional CT scanner over the region limited to the stones identified on the dual-source scans. After 3D deformable registration of the 80- and 140-kV images, UA and non-UA stones were identified using commercial software. The sensitivity, specificity, and accuracy of stone classification were calculated using the dual-source results as the reference standard. RESULTS: A total of 469 stones were identified in the dual-source examinations (26 UA and 443 non-UA stones). The average in-plane stone diameter was 4.4 ± 2.5 (SD) mm (range, 2.0-18.9 mm). The overall sensitivity, specificity, and accuracy for identifying UA stones were 73.1%, 90.1%, and 89.1%, respectively. The sensitivity, specificity, and accuracy were 94.7%, 96.9%, and 96.8% for stones 3 mm or larger (n = 341 [19 UA and 322 non-UA]). CONCLUSION: Accurate differentiation of UA from non-UA renal stones is feasible using two consecutively acquired and spatially registered conventional CT scans.


Assuntos
Imageamento Tridimensional/métodos , Cálculos Renais/química , Cálculos Renais/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Ácido Úrico/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
5.
Proc Natl Acad Sci U S A ; 109(34): 13532-7, 2012 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-22826222

RESUMO

Marked changes in human dispersal and development during the Middle to Upper Paleolithic transition have been attributed to massive volcanic eruption and/or severe climatic deterioration. We test this concept using records of volcanic ash layers of the Campanian Ignimbrite eruption dated to ca. 40,000 y ago (40 ka B.P.). The distribution of the Campanian Ignimbrite has been enhanced by the discovery of cryptotephra deposits (volcanic ash layers that are not visible to the naked eye) in archaeological cave sequences. They enable us to synchronize archaeological and paleoclimatic records through the period of transition from Neanderthal to the earliest anatomically modern human populations in Europe. Our results confirm that the combined effects of a major volcanic eruption and severe climatic cooling failed to have lasting impacts on Neanderthals or early modern humans in Europe. We infer that modern humans proved a greater competitive threat to indigenous populations than natural disasters.


Assuntos
Fósseis , Homem de Neandertal , Erupções Vulcânicas , Animais , Arqueologia/métodos , Clima , Hominidae , Humanos , Espectrometria de Massas/métodos , Microscopia Eletrônica de Varredura/métodos
6.
AJR Am J Roentgenol ; 202(4): W349-56, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24660733

RESUMO

OBJECTIVE: The objective of our study was to evaluate the accuracy of subtraction color-map images created from contrast-enhanced CT (CECT) and unenhanced CT for the diagnosis of pancreatic necrosis in the early stage of acute pancreatitis. MATERIALS AND METHODS: Forty-eight patients underwent unenhanced CT and CECT within 72 hours from the onset of acute pancreatitis. Subtraction color-map images were created from unenhanced CT and CECT using a 3D nonrigid registration method. Three radiologists reviewed two image sets: CECT alone and subtraction color-map images in conjunction with CECT. Readers evaluated each image set for the presence of pancreatic necrosis. The reference standard for pancreatic necrosis was CT or MRI 1 week or more after the onset of acute pancreatitis. The performance of each image set for the prediction of pancreatic necrosis was calculated and compared using the McNemar test. RESULTS: Eleven of the 48 patients developed pancreatic necrosis. There were no technical failures creating the subtraction images. The sensitivity, specificity, and accuracy for predicting pancreatic necrosis with CECT were 64%, 97%, and 90%, respectively, for reader 1; 73%, 87%, and 83% for reader 2; and 73%, 87%, and 83% for reader 3. The sensitivity, specificity, and accuracy for predicting pancreatic necrosis with the subtraction color maps were 100%, 100%, and 100%, respectively, for reader 1; 100%, 95%, and 96% for reader 2; and 82%, 92%, and 90% for reader 3. Accuracy significantly improved with the addition of subtraction color maps compared with CECT alone for reader 1 (p = 0.03) and reader 2 (p = 0.02) but not for reader 3 (p = 0.37). CONCLUSION: A subtraction color map is accurate in the diagnosis of pancreatic necrosis in the early stage of acute pancreatitis.


Assuntos
Pancreatite/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , APACHE , Cor , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iohexol , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Necrose , Pancreatite/mortalidade , Pancreatite/patologia , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Técnica de Subtração
7.
AJR Am J Roentgenol ; 201(4): W626-32, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24059402

RESUMO

OBJECTIVE: The objective of our study was to evaluate in phantoms the differences in CT image noise and artifact level between two types of commercial CT detectors: one with distributed electronics (conventional) and one with integrated electronics intended to decrease system electronic noise. MATERIALS AND METHODS: Cylindric water phantoms of 20, 30, and 40 cm in diameter were scanned using two CT scanners, one equipped with integrated detector electronics and one with distributed detector electronics. All other scanning parameters were identical. Scans were acquired at four tube potentials and 10 tube currents. Semianthropomorphic phantoms were scanned to mimic the shoulder and abdominal regions. Images of two patients were also selected to show the clinical values of the integrated detector. RESULTS: Reduction of image noise with the integrated detector depended on phantom size, tube potential, and tube current. Scans that had low detected signal had the greatest reductions in noise, up to 40% for a 30-cm phantom scanned using 80 kV. This noise reduction translated into up to 50% in dose reduction to achieve equivalent image noise. Streak artifacts through regions of high attenuation were reduced by up to 45% on scans obtained using the integrated detector. Patient images also showed superior image quality for the integrated detector. CONCLUSION: For the same applied radiation level, the use of integrated electronics in a CT detector showed a substantially reduced level of electronic noise, resulting in reductions in image noise and artifacts, compared with detectors having distributed electronics.


Assuntos
Artefatos , Eletrônica/instrumentação , Aumento da Imagem/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
8.
AJR Am J Roentgenol ; 201(2): W297-306, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23883244

RESUMO

OBJECTIVE: The purpose of this study is to assess the ability of a novel automatic tube potential selection tool to reduce radiation dose while maintaining diagnostic quality in CT angiography (CTA) and contrast-enhanced abdominopelvic CT. MATERIALS AND METHODS: One hundred one CTA examinations and 90 contrastenhanced abdominopelvic examinations were performed using an automatic tube potential selection tool on a 128-MDCT scanner. Two vascular radiologists and two abdominal radiologists evaluated the image quality for sharpness, noise, artifact, and diagnostic confidence. In a subset of patients who had undergone prior studies (CTA, 28 patients; abdominopelvic CT, 25 patients), a side-by-side comparison was performed by a separate radiologist. Dose reduction and iodine contrast-to-noise ratio resulting from use of the tool were calculated. RESULTS: For CTA, 80 or 100 kV was selected for 73% of the scans, with a mean dose reduction of 36% relative to the reference 120-kV protocol. For abdominopelvic CT examinations, 80 or 100 kV was used for 55% of the scans, with a mean dose reduction of 25%. Overall dose reduction relative to the reference 120-kV protocol was 25% and 13% for CTA and abdominopelvic CT scans, respectively. Over 98% of scans had acceptable sharpness, noise texture, artifact, and diagnostic confidence for both readers and diagnostic tasks; 94-100% of scans had acceptable noise. Iodine contrast-to-noise ratio was significantly higher than (p < 0.001) or similar to (p = 0.11) that of prior scans, and equivalent quality was achieved despite the dose reduction. CONCLUSION: Automatic tube potential selection provides an efficient and quantitativeway to guide the selection of the optimal tube potential for CTA and abdominopelvic CT examinations.


Assuntos
Angiografia/métodos , Doses de Radiação , Proteção Radiológica/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Automação , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Comput Assist Tomogr ; 37(2): 203-11, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23493209

RESUMO

OBJECTIVE: The objective of this study was to determine the effect of Sinogram-Affirmed Iterative Reconstruction (SAFIRE) on radiological detection, diagnostic confidence, and image quality at half-dose, contrast-enhanced abdominopelvic computed tomography. METHODS: Forty dual-source examinations were reconstructed using routine-dose with filtered back projection, half-dose filtered back projection, and half-dose SAFIRE. Three radiologists detected lesions in abdominopelvic organs, reporting findings of potential medical significance, diagnostic confidence, and image quality. RESULTS: There was greater than 78% concordance between full- and half-dose images ± SAFIRE, and no difference in the detection of lesions within organs between half-dose images ± SAFIRE (P = 0.22 - 1.0). Detection of potentially important findings varied by reader, but not between dose/reconstruction methods. Diagnostic confidence varied widely (P < 0.001 to P > 0.91). Sinogram-Affirmed Iterative Reconstruction significantly improved image quality in the pelvis (P ≤ 0.04). CONCLUSIONS: Half-dose images ± SAFIRE had organ-specific detections similar to routine-dose images. Sinogram-Affirmed Iterative Reconstruction improved image quality in the pelvis, but diagnostic confidence and image quality scores in the abdomen depended on the reader.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Competência Clínica , Estudos de Coortes , Meios de Contraste , Humanos , Projetos Piloto , Doses de Radiação , Estatísticas não Paramétricas
10.
Sci Adv ; 9(41): eadh9513, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37824627

RESUMO

Antarctic climate warming and atmospheric CO2 rise during the last deglaciation may be attributed in part to sea ice reduction in the Southern Ocean. Yet, glacial-interglacial Antarctic sea ice dynamics and underlying mechanisms are poorly constrained, as robust sea ice proxy evidence is sparse. Here, we present a molecular biomarker-based sea ice record that resolves the spring/summer sea ice variability off East Antarctica during the past 40 thousand years (ka). Our results indicate that substantial sea ice reduction culminated rapidly and contemporaneously with upwelling of carbon-enriched waters in the Southern Ocean at the onset of the last deglaciation but began at least ~2 ka earlier probably driven by an increasing local integrated summer insolation. Our findings suggest that sea ice reduction and associated feedbacks facilitated stratification breakup and outgassing of CO2 in the Southern Ocean and warming in Antarctica but may also have played a leading role in initializing these deglacial processes in the Southern Hemisphere.

11.
Radiology ; 262(1): 191-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22190658

RESUMO

PURPOSE: To compare the dose and image quality of three methods for reducing the radiation dose to the eye at head computed tomography (CT): bismuth shielding, organ-based tube current modulation (TCM), and global reduction of the tube current. MATERIALS AND METHODS: An anthropomorphic head phantom was scanned under six conditions: (a) without any dose reduction techniques (reference scanning); (b) with one bismuth eye shield; (c) with organ-based TCM; (d) with reduced tube current to yield the same dose reduction as one bismuth shield; (e) with two layers of bismuth shields; and (f) with organ-based TCM and one bismuth shield. Dose to the eye, image noise, and CT numbers in the brain region were measured and compared. The effect of increasing distance between the bismuth shield and eye lens was also investigated. RESULTS: Relative to the reference scan, the dose to the eye was reduced by 26.4% with one bismuth shield, 30.4% with organ-based TCM, and 30.2% with a global reduction in tube current. A combination of organ-based TCM with one bismuth shield reduced the dose by 47.0%. Image noise in the brain region was slightly increased for all dose reduction methods. CT numbers were increased whenever the bismuth shield was used. Increasing the distance between the bismuth shield and the eye lens helped reduce CT number errors, but the increase in noise remained. CONCLUSION: Organ-based TCM provided superior image quality to that with bismuth shielding while similarly reducing dose to the eye. Simply reducing tube current globally by about 30% provides the same dose reduction to the eye as bismuth shielding; however, CT number accuracy is maintained and dose is reduced to all parts of the head.


Assuntos
Olho/efeitos da radiação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/instrumentação , Artefatos , Bismuto , Humanos , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente
12.
AJR Am J Roentgenol ; 199(5): 1070-7, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23096181

RESUMO

OBJECTIVE: The purpose of this study was to determine whether the use of an automated CT kilovoltage (kV) selection tool (Auto kV) can result in lower radiation dose without sacrificing image quality in contrast-enhanced abdominopelvic CT. MATERIALS AND METHODS: Tube potential, radiation dose, and iodine contrast-to-noise ratio (CNR) were retrospectively evaluated in 36 patients who underwent abdominopelvic CT with Auto kV, and compared with results from size-matched control patients using identical protocols. Two radiologists evaluated image quality (sharpness, noise, and diagnostic confidence) blinded to kV. Volume CT dose index (CTDI(vol)) was also compared with what each patient would have received from scanning at 120 kV. RESULTS: Mean (SD) CTDI(vol) was 16.0 (4.4) mGy after Auto kV versus 19.5 (4.0) mGy using standard 120-kV prescription and was 19.3 (6.0) mGy in control subjects (yielding dose reductions of 18.0% and 17.2%, respectively; p < 0.001 for both). Thirty of 36 patients were scanned at 100 kV (median dose reduction, 25%). Auto kV images were rated as very sharp in 33 (92%) and 36 (100%) cases versus 36 (100%) and 35 (97%) of the control cases, with all cases scored as having optimal noise. Readers had full diagnostic confidence in 34 (94%) and 36 (100%) of Auto kV cases; one reader scored "probably confident" in two cases (6%). Iodine CNRs for the aorta, liver, and portal vein were similar between Auto kV cases and control cases (p > 0.50, all comparisons). CONCLUSION: The use of an automated kV selection tool results in significant dose savings while maintaining diagnostic image quality and iodine CNR.


Assuntos
Doses de Radiação , Proteção Radiológica/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
13.
J Comput Assist Tomogr ; 36(5): 560-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22992607

RESUMO

OBJECTIVE: To evaluate a method for obtaining half-dose CT images for observer studies evaluating lower-dose CT. METHODS: Phantoms of varying sizes were scanned at multiple tube potentials using dose-matched dual-source (DS) and single-source (SS) protocols. Images from single-tube reconstruction of DS data were compared with SS images acquired at half-original CTDIvol. Thirty patients underwent supine SS and dose-matched prone DS CT colonography (CTC). Half-dose prone images were reconstructed with sinogram-affirmed iterative reconstruction (SAFIRE). Two radiologists scored image quality on 2-dimensional (2D) and 3D images. RESULTS: Image noise was similar between half-dose SS images and DS images reconstructed from one tube only with tube potential of 120 kV or more for phantoms 40 cm or smaller (P < 0.05). For both readers, the patients' CTC image quality scores were more than 84% concordant between SS or DS CTC images, and half-dose-prone CTC images with SAFIRE had 84% or more concordance with routine-dose CTC except for 3D image noise. CONCLUSIONS: In appropriately sized patients, DS acquisition with single-tube reconstruction can create half-dose images, permitting comparison to full-dose images. For CTC, there is comparable image quality for colonic evaluation between full-dose and half-dose images reconstructed with SAFIRE.


Assuntos
Colonografia Tomográfica Computadorizada/métodos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Feminino , Humanos , Imageamento Tridimensional , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído , Estatísticas não Paramétricas
14.
AJR Am J Roentgenol ; 197(3): 689-95, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21862813

RESUMO

OBJECTIVE: The purpose of this study was to evaluate in phantoms the dose reduction to anterior surfaces and image quality with organ-based tube-current modulation in head and thoracic CT. MATERIALS AND METHODS: Organ-based tube-current modulation is designed to reduce radiation dose to superficial radiosensitive organs, such as the lens of the eye, thyroid, and breast, by decreasing the tube current when the tube passes closest to these organs. Dose and image quality were evaluated in phantoms for clinical head and thorax examination protocols with and without organ-based tube-current modulation. Surface dose reduction as a function of position was measured using a 32-cm CT dose index (CTDI) phantom, an anthropomorphic adult phantom, and ion chambers. Surface dose reduction as a function of patient size was investigated using three semianthropomorphic phantoms with posteroanterior dimensions of 14, 25, and 31 cm. Image noise (the SD of CT numbers in regions of interest) was evaluated for the anthropomorphic and the semianthropomorphic phantoms. RESULTS: For equivalent scanner output (volume CTDI), the dose to the midline of the anterior surface was reduced by 27-50%, depending on the anatomic region (head or thorax) and phantom size, and the dose to the posterior surface was correspondingly increased. Image noise was not significantly different between scans with and without organ-based tube-current modulation (p = 0.85). CONCLUSION: Organ-based tube-current modulation can reduce the dose to the anterior surface of patients without increasing image noise by commensurately increasing the dose to the posterior surface. This technique can reduce the dose to anterior radiosensitive organs for head and thoracic CT scans.


Assuntos
Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/instrumentação , Cabeça/efeitos da radiação , Humanos , Imagens de Fantasmas , Radiometria/métodos , Tórax/efeitos da radiação
15.
Nat Commun ; 10(1): 5040, 2019 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-31695032

RESUMO

The last interglacial (LIG; ~130 to ~118 thousand years ago, ka) was the last time global sea level rose well above the present level. Greenland Ice Sheet (GrIS) contributions were insufficient to explain the highstand, so that substantial Antarctic Ice Sheet (AIS) reduction is implied. However, the nature and drivers of GrIS and AIS reductions remain enigmatic, even though they may be critical for understanding future sea-level rise. Here we complement existing records with new data, and reveal that the LIG contained an AIS-derived highstand from ~129.5 to ~125 ka, a lowstand centred on 125-124 ka, and joint AIS + GrIS contributions from ~123.5 to ~118 ka. Moreover, a dual substructure within the first highstand suggests temporal variability in the AIS contributions. Implied rates of sea-level rise are high (up to several meters per century; m c-1), and lend credibility to high rates inferred by ice modelling under certain ice-shelf instability parameterisations.

16.
Indian Heart J ; 70(3): 443-445, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29961466

RESUMO

There is an urgent need to develop new protocols to reduce radiation dose of coronary computed tomography angiography (CTA). The aim of this pilot study was to demonstrate the feasibility of an ultra-low dose CTA scanning.


Assuntos
Angiografia por Tomografia Computadorizada/normas , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/normas , Lesões por Radiação/prevenção & controle , Adolescente , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Doses de Radiação , Adulto Jovem
17.
Invest Radiol ; 53(2): 103-109, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29016370

RESUMO

OBJECTIVES: The aim of this study was to evaluate a prototype dual-energy computed tomography calcium subtraction algorithm and its impact on luminal visualization in patients with heavily calcified coronary arteries. MATERIALS AND METHODS: Twenty-nine patients (62% male; mean age, 64 ± 7 years) who had undergone dual-energy coronary computed tomography angiography were retrospectively included in this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study. Linearly blended (M_0.6) and calcium-subtracted images were reconstructed. Two independent observers assessed luminal visualization of the coronary arteries in a segment-based analysis, subjective image quality, and diagnostic confidence using 5-point Likert scales. Contrast-to-noise ratios for both data sets were calculated. Wilcoxon testing and Cohen's κ were used for statistical comparisons. RESULTS: Calcium-subtracted image series showed improved lumen visualization of the coronary arteries (P = 0.008), with excellent interreader agreement (mean score, 3.3; κ = 0.82), compared with M_0.6 series (mean score, 2.9; κ = 0.77). The calcium subtraction algorithm improved diagnostic confidence compared with the M_0.6 reconstructions (mean scores, 4.0 and 3.1, respectively; all P ≤ 0.002). The image quality analysis showed no significant differences between calcium-subtracted and M_0.6 data sets (subjectively: mean scores, 4.1 and 4.2, respectively, P = 0.442; objectively: mean contrast-to-noise ratio, 37.0 and 38.2, respectively, P = 0.733). CONCLUSIONS: A prototype algorithm for calcium subtraction improves coronary lumen visualization and diagnostic confidence in patients with heavy coronary calcifications without differences in conventional subjective and objective measures of image quality.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Invest Radiol ; 52(11): 693-700, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28562414

RESUMO

OBJECTIVES: Explore the potential of dual-source dual-energy (DSDE) computed tomography (CT) to retrospectively analyze the uniformity of iron distribution and establish iron concentration ranges and distribution patterns found in healthy livers. MATERIALS AND METHODS: Ten mixtures consisting of an iron nitrate solution and deionized water were prepared in test tubes and scanned using a DSDE 128-slice CT system. Iron images were derived from a 3-material decomposition algorithm (optimized for the quantification of iron). A conversion factor (mg Fe/mL per Hounsfield unit) was calculated from this phantom study as the quotient of known tube concentrations and their corresponding CT values. Retrospective analysis was performed of patients who had undergone DSDE imaging for renal stones. Thirty-seven patients with normal liver function were randomly selected (mean age, 52.5 years). The examinations were processed for iron concentration. Multiple regions of interest were analyzed, and iron concentration (mg Fe/mL) and distribution was reported. RESULTS: The mean conversion factor obtained from the phantom study was 0.15 mg Fe/mL per Hounsfield unit. Whole-liver mean iron concentrations yielded a range of 0.0 to 2.91 mg Fe/mL, with 94.6% (35/37) of the patients exhibiting mean concentrations below 1.0 mg Fe/mL. The most important finding was that iron concentration was not uniform and patients exhibited regionally high concentrations (36/37). These regions of higher concentration were observed to be dominant in the middle-to-upper part of the liver (75%), medially (72.2%), and anteriorly (83.3%). CONCLUSIONS: Dual-source dual-energy CT can be used to assess the uniformity of iron distribution in healthy subjects. Applying similar techniques to unhealthy livers, future research may focus on the impact of hepatic iron content and distribution for noninvasive assessment in diseased subjects.


Assuntos
Ferro/metabolismo , Fígado/diagnóstico por imagem , Fígado/metabolismo , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Adulto Jovem
19.
Int J Cardiovasc Imaging ; 32(2): 339-346, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26474570

RESUMO

Ventricular volumes and ejection fraction are often used in clinical decision making in patients with congenital heart disease (CHD). The referral diagnosis, radiation exposure and image quality of functional cardiac computed tomography (CT) in a relatively large cohort of patients of CHD has not been reported. This is a retrospective evaluation of functional CT studies performed in CHD patients from three institutions (1/2007-3/2013). Patient and scanner characteristics, radiation dose estimates and image quality were compared. Two hundred ninety-eight functional CT studies were evaluated. The most common referral diagnosis were tetralogy of Fallot (33 %), transposition complexes (24 %) single ventricle heart disease (15 %), and left sided obstruction (15 %). The reason for cardiac CT was presence of pacemaker (60 %), need for detailed coronary artery imaging (18 %), metallic artifact in CMR (12 %), evaluation of prosthetic valve function (4 %), and claustrophobia or BMI too large for the available MR scanner (6 %). 266 (89.3 %) scans allowed quantification of ventricular function, 25 (8.4 %) scans allowed qualitative assessment of function, and 7 (2.3 %) of the scans were non-diagnostic for functional analysis. Median DLP was 399 mGy cm (186, 614), and median effective dose was 5.5 mSv (2.6, 8.5). Radiation dose and image quality varied across institutions. Cardiac CT function imaging can be performed in patients with congenital heart disease when CMR is contraindicated or has poor image quality. Radiation dose and image quality varies across institutions.

20.
J Cardiovasc Comput Tomogr ; 10(2): 173-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26794867

RESUMO

BACKGROUND: The use of cardiac computed tomography (CT) for quantification of ventricular function is limited by relatively high radiation dose. OBJECTIVES: The goal of this study was to describe the radiation exposure and image quality of 70 kVp functional cardiac CT in patients with congenital heart disease (CHD). METHODS: A retrospective review of 70 kVp ECG gated functional CT scans using tube current modulation was performed in CHD patients at a single institution. Quantitative and qualitative (assessed by myocardial segment, 1-4; 1 = optimal) image quality was determined. Per segment image quality was compared between thin (1.5 mm) and thick (8 mm) reconstructions and by patient age and size. Scan DLP was used to estimate radiation dose. RESULTS: 72 scans were performed during the time of review (7/2013-6/2015). Median patient age was 19.5 years (8.0, 27.1) and BMI was 20.1 (16.6, 24.5) kg/m(2). Median functional scan DLP was 78.8 (45.5, 98) and unadjusted and adjusted procedural mSv were 1.10 (0.64, 1.37) and 1.13 (0.90, 1.37). Image quality of 1 was achieved in all myocardial segments in >75% of scans. Patients with a weight ≥75 kg were more likely to have a scan achieve optimal image when using thick reconstructions compared to thin (81.3% vs. 43.8%; p = 0.028). CONCLUSIONS: Imaging of ventricular function with 70 kVp in CHD patients can be done with low radiation doses and provides diagnostic image quality, particularly for patients <75 kg. In larger patients, thicker slice reconstruction improved image quality.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Peso Corporal , Técnicas de Imagem de Sincronização Cardíaca , Criança , Pré-Escolar , Eletrocardiografia , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Função Ventricular , Adulto Jovem