Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Med Phys ; 38(1): 210-22, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21361189

RESUMO

PURPOSE: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D x-ray reconstruction angiography (3DRA) and time of flight magnetic resonance angiography (TOF-MRA) images available in the clinical routine. METHODS: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols, and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using different imaging equipment. Evaluation included qualitative and quantitative analyses of the segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: isointensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an intermodality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. RESULTS: Both GAR and ISE differed from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatability of GAR was superior to manual measurements and ISE. The intermodality agreement was similar between GAR and the manual measurements. CONCLUSIONS: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.


Assuntos
Angiografia/métodos , Circulação Cerebrovascular , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico , Aneurisma Intracraniano/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Automação , Feminino , Humanos , Imageamento Tridimensional/normas , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos
2.
Med Phys ; 37(4): 1689-706, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20443490

RESUMO

PURPOSE: In this article, the authors studied the feasibility of estimating regional mechanical properties in cerebral aneurysms, integrating information extracted from imaging and physiological data with generic computational models of the arterial wall behavior. METHODS: A data assimilation framework was developed to incorporate patient-specific geometries into a given biomechanical model, whereas wall motion estimates were obtained from applying registration techniques to a pair of simulated MR images and guided the mechanical parameter estimation. A simple incompressible linear and isotropic Hookean model coupled with computational fluid-dynamics was employed as a first approximation for computational purposes. Additionally, an automatic clustering technique was developed to reduce the number of parameters to assimilate at the optimization stage and it considerably accelerated the convergence of the simulations. Several in silico experiments were designed to assess the influence of aneurysm geometrical characteristics and the accuracy of wall motion estimates on the mechanical property estimates. Hence, the proposed methodology was applied to six real cerebral aneurysms and tested against a varying number of regions with different elasticity, different mesh discretization, imaging resolution, and registration configurations. RESULTS: Several in silico experiments were conducted to investigate the feasibility of the proposed workflow, results found suggesting that the estimation of the mechanical properties was mainly influenced by the image spatial resolution and the chosen registration configuration. According to the in silico experiments, the minimal spatial resolution needed to extract wall pulsation measurements with enough accuracy to guide the proposed data assimilation framework was of 0.1 mm. CONCLUSIONS: Current routine imaging modalities do not have such a high spatial resolution and therefore the proposed data assimilation framework cannot currently be used on in vivo data to reliably estimate regional properties in cerebral aneurysms. Besides, it was observed that the incorporation of fluid-structure interaction in a biomechanical model with linear and isotropic material properties did not have a substantial influence in the final results.


Assuntos
Biologia Computacional/métodos , Aneurisma Intracraniano/patologia , Imageamento por Ressonância Magnética/métodos , Algoritmos , Fenômenos Biomecânicos , Análise por Conglomerados , Simulação por Computador , Elasticidade , Análise de Elementos Finitos , Humanos , Processamento de Imagem Assistida por Computador , Aneurisma Intracraniano/metabolismo , Movimento , Software , Estresse Mecânico
3.
J Nucl Med ; 55(5): 830-7, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24686779

RESUMO

UNLABELLED: Longitudinal imaging of intratumoral distributions of antibodies in vivo in mouse cancer models is of great importance for developing cancer therapies. In this study, multipinhole SPECT with sub-half-millimeter resolution was tested for exploring intratumoral distributions of radiolabeled antibodies directed toward the epidermal growth factor receptor (EGFr) and compared with full 3-dimensional target expression assessed by immunohistochemistry. METHODS: (111)In-labeled zalutumumab, a human monoclonal human EGFr-targeting antibody, was administered at a nonsaturating dose to 3 mice with xenografted A431 tumors exhibiting high EGFr expression. Total-body and focused in vivo tumor SPECT was performed at 0 and 48 h after injection and compared both visually and quantitatively with full 3-dimensional immunohistochemical staining for EGFr target expression. RESULTS: SPECT at 48 h after injection showed that activity was predominantly concentrated in the tumor (10.5% ± 1.3% of the total-body activity; average concentration, 30.1% ± 4.6% of the injected dose per cubic centimeter). (111)In-labeled EGFr-targeting antibodies were distributed heterogeneously throughout the tumor. Some hot spots were observed near the tumor rim. Immunohistochemistry indicated that the antibody distributions obtained by SPECT were morphologically similar to those obtained for ex vivo EGFr target expression. Regions showing low SPECT activity were necrotic or virtually negative for EGFr target expression. A good correlation (r = 0.86, P < 0.0001) was found between the percentage of regions showing low activity on SPECT and the percentage of necrotic tissue on immunohistochemistry. CONCLUSION: Multipinhole SPECT enables high-resolution visualization and quantification of the heterogeneity of (111)In-zalutumumab concentrations in vivo.


Assuntos
Anticorpos/química , Receptores ErbB/metabolismo , Imageamento Tridimensional , Tomografia Computadorizada de Emissão de Fóton Único , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais Humanizados , Linhagem Celular Tumoral , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imunoconjugados/química , Imuno-Histoquímica , Radioisótopos de Índio/química , Camundongos , Camundongos SCID , Transplante de Neoplasias , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
4.
EJNMMI Res ; 3(1): 7, 2013 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-23369630

RESUMO

BACKGROUND: In single-photon emission computed tomography (SPECT), attenuation of photon flux in tissue affects quantitative accuracy of reconstructed images. Attenuation maps derived from X-ray computed tomography (CT) can be employed for attenuation correction. The attenuation coefficients as well as registration accuracy between SPECT and CT can be influenced by several factors. Here we investigate how such inaccuracies influence micro-SPECT quantification. METHODS: Effects of (1) misalignments between micro-SPECT and micro-CT through shifts and rotation, (2) globally altered attenuation coefficients and (3) combinations of these were evaluated. Tests were performed with a NEMA NU 4-2008 phantom and with rat cadavers containing sources with known activity. RESULTS: Changes in measured activities within volumes of interest in phantom images ranged from <1.5% (125I) and <0.6% (201Tl, 99mTc and 111In) for 1-mm shifts to <4.5% (125I) and <1.7% (201Tl, 99mTc and 111In) with large misregistration (3 mm). Changes induced by 15° rotation were smaller than those by 3-mm shifts. By significantly altering attenuation coefficients (±10%), activity changes of <5.2% for 125I and <2.7% for 201Tl, 99mTc and 111In were induced. Similar trends were seen in rat studies. CONCLUSIONS: While getting sufficient accuracy of attenuation maps in clinical imaging is highly challenging, our results indicate that micro-SPECT quantification is quite robust to various imperfections of attenuation maps.

5.
Clin Neurol Neurosurg ; 111(9): 717-23, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19560262

RESUMO

OBJECTIVES: Computed tomography venography (CTV) has proven to be a reliable imaging method in the evaluation of cerebral venous thrombosis with good correlation to magnetic resonance (MR) imaging and digital subtraction angiography (DSA). It is fast and widely accessible, especially in the emergency setting. For better visualization of vascular structures bone is often removed from the images. The purpose of this study was to evaluate the quality of a fully automatic bone removal method, matched mask bone elimination (MMBE), and to assess the interobserver variability of the CTV technique. PATIENTS AND METHODS: Fifty patients with clinical suspicion of cerebral venous thrombosis underwent multislice CTV with MMBE post-processing. Axial source images and maximum intensity projections were retrospectively evaluated by two neuroradiologists for quality of bone removal and for the presence or absence of thrombosis in nine dural sinuses and five deep cerebral veins. A per sinus/vein and a per patient analysis (thrombosis in at least one sinus or vein) was performed and interobserver agreement was assessed. RESULTS: Both observers considered bone removal good in all patients (100%). Interobserver agreement per patient was excellent (kappa=0.83), with a full agreement in 47 of 50 patients (94%). The interobserver agreement per sinus or vein was good (kappa=0.76), with a full agreement in 679 of 700 sinuses or veins (97%). CONCLUSION: CTV aided with MMBE is a robust technique for visualization of the intracranial venous circulation, removing bone effectively. CTV has high interobserver agreement for presence or absence of cerebral venous thrombosis.


Assuntos
Osso e Ossos/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Trombose Intracraniana/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral , Criança , Pré-Escolar , Cavidades Cranianas/diagnóstico por imagem , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Flebografia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
6.
Eur Radiol ; 16(2): 391-8, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16170556

RESUMO

The aim of the study was to evaluate a new method for automated definition of a center lumen line in vessels in cardiovascular image data. This method, called VAMPIRE, is based on improved detection of vessel-like structures. A multiobserver evaluation study was conducted involving 40 tracings in clinical CTA data of carotid arteries to compare VAMPIRE with an established technique. This comparison showed that VAMPIRE yields considerably more successful tracings and improved handling of stenosis, calcifications, multiple vessels, and nearby bone structures. We conclude that VAMPIRE is highly suitable for automated definition of center lumen lines in vessels in cardiovascular image data.


Assuntos
Angiografia/métodos , Arteriopatias Oclusivas/diagnóstico por imagem , Diagnóstico por Computador/métodos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Computação Matemática , Tomografia Computadorizada Espiral/métodos , Algoritmos , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Humanos , Artéria Ilíaca/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Variações Dependentes do Observador , Sensibilidade e Especificidade , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA