Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Chemistry ; : e202401407, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38699860

RESUMO

Semiochemicals can be used to manipulate insect behaviour for sustainable pest management strategies, but their high volatility is a major issue for their practical implementation. Inclusion of these molecules within porous materials is a potential solution to this issue, as it can allow for a slower and more controlled release. In this work, we demonstrate that a series of Zr(IV) and Al(III) metal-organic frameworks (MOFs) with channel-type pores enable controlled release of three semiochemicals over 100 days by pore size design, with the uptake and rate of release highly dependent on the pore size. Insight from grand canonical Monte Carlo simulations indicates that this is due to weaker MOF-guest interactions per guest molecule as the pore size increases. These MOFs are all stable post-release and can be reloaded to show near-identical re-release profiles. These results provide valuable insight on the diffusion behaviour of volatile guests in MOFs, and for the further development of porous materials for sustainable agriculture applications.

2.
Osteoporos Int ; 32(8): 1487-1497, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33768342

RESUMO

Older adults spend more than 8 h/day in sedentary behaviours. Detrimental effects of sedentary behaviour (SB) on health are established, yet little is known about SB and bone health (bone mineral density; BMD) in older adults. The purpose of this review is to examine associations of SB with BMD in older adults. Five electronic databases were searched: Web of Science (Core Collection); PubMed; EMBASE; Sports Medicine and Education and PsycInfo. Inclusion criteria were healthy older adults mean age ≥ 65 years; measured SB and measured BMD using dual-energy X-ray absorptiometry. Quality was assessed using National Institute of Health Quality Assessment Tool for Observational Cohort and Cross-Sectional Studies. After excluding duplicates 17813 papers were assessed; 17757 were excluded on title/abstract, 49 at full text, resulting in two prospective and five cross-sectional observational studies reviewed. Four were rated 'good' and three were rated 'fair' using the quality assessment criteria. Findings varied across the studies and differed by gender. In women, four studies reported significant positive associations of SB with BMD at different sites, and two found significant negative associations. Five studies which examined both men and women, men reported negative or no associations of SB with femoral neck, pelvic, whole body, spine or leg BMD. Whilst these findings suggest differences between men and women in the associations of SB with BMD, they may be due to the varying anatomical sections examined for BMD, the different methods used to measure SB, the varied quality of the studies included and the limited number of published findings.


Assuntos
Densidade Óssea , Comportamento Sedentário , Absorciometria de Fóton , Idoso , Estudos Transversais , Feminino , Colo do Fêmur , Humanos , Masculino , Estudos Prospectivos
3.
Magn Reson Med ; 84(2): 1035-1047, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31883207

RESUMO

PURPOSE: We explore the use of thermo-acoustic ultrasound (TAUS) to monitor temperature at the tips of conductive device leads during MRI. THEORY: In TAUS, rapid radiofrequency (RF) power deposition excites an acoustic signal via thermoelastic expansion. Coupling of the MRI RF transmit to device leads causes SAR amplification at lead tips, allowing MRI RF transmitters to excite significant lead tip TAUS signals. Because the amplitude of the TAUS signal depends on temperature, it becomes feasible to monitor the lead tip temperature during MRI by tracking the TAUS amplitude. METHODS: The TAUS temperature dependence was characterized in a phantom and in tissue. To perform TAUS acquisitions in an MRI scanner, amplitude modulated RF chirps were transmitted by the body coil, and the lead tip TAUS signal was detected by an ultrasonic transducer. The TAUS signal level was correlated with the RF current induced on the lead and the associated B1 artifacts in MRI. TAUS signals acquired during RF-induced heating were used to estimate the lead tip temperature. RESULTS: The TAUS signal exhibited strong dependence on temperature, increasing over 30% with 10∘ C of heating both in the phantom and in tissue. A lead tip TAUS signal was observed for a 100 mA rms current induced on a lead. During RF-induced heating, the TAUS signal appeared to accurately approximate the peak lead tip temperature. CONCLUSIONS: TAUS allows for noninvasive monitoring of lead tip temperature in an MRI environment. With further development, TAUS opens new avenues to improve RF device safety during MRI scans.


Assuntos
Temperatura Alta , Ondas de Rádio , Acústica , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Temperatura
4.
Int J Behav Nutr Phys Act ; 15(1): 21, 2018 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-29482617

RESUMO

BACKGROUND: Sedentary behaviour is a public health concern that requires surveillance and epidemiological research. For such large scale studies, self-report tools are a pragmatic measurement solution. A large number of self-report tools are currently in use, but few have been validated against an objective measure of sedentary time and there is no comparative information between tools to guide choice or to enable comparison between studies. The aim of this study was to provide a systematic comparison, generalisable to all tools, of the validity of self-report measures of sedentary time against a gold standard sedentary time objective monitor. METHODS: Cross sectional data from three cohorts (N = 700) were used in this validation study. Eighteen self-report measures of sedentary time, based on the TAxonomy of Self-report SB Tools (TASST) framework, were compared against an objective measure of postural sitting (activPAL) to provide information, generalizable to all existing tools, on agreement and precision using Bland-Altman statistics, on criterion validity using Pearson correlation, and on data loss. RESULTS: All self-report measures showed poor accuracy compared with the objective measure of sedentary time, with very wide limits of agreement and poor precision (random error > 2.5 h). Most tools under-reported total sedentary time and demonstrated low correlations with objective data. The type of assessment used by the tool, whether direct, proxy, or a composite measure, influenced the measurement characteristics. Proxy measures (TV time) and single item direct measures using a visual analogue scale to assess the proportion of the day spent sitting, showed the best combination of precision and data loss. The recall period (e.g. previous week) had little influence on measurement characteristics. CONCLUSION: Self-report measures of sedentary time result in large bias, poor precision and low correlation with an objective measure of sedentary time. Choice of tool depends on the research context, design and question. Choice can be guided by this systematic comparative validation and, in the case of population surveillance, it recommends to use a visual analog scale and a 7 day recall period. Comparison between studies and improving population estimates of average sedentary time, is possible with the comparative correction factors provided.


Assuntos
Exercício Físico , Comportamento Sedentário , Autorrelato/normas , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Rememoração Mental , Pessoa de Meia-Idade , Vigilância da População , Postura , Reprodutibilidade dos Testes , Inquéritos e Questionários , Televisão , Tempo
5.
Magn Reson Med ; 76(3): 1015-21, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26418283

RESUMO

PURPOSE: To design, construct, and validate a semiflexible 64-channel receive-only phased array for pediatric body MRI at 3T. METHODS: A 64-channel receive-only phased array was developed and constructed. The designed flexible coil can easily conform to different patient sizes with nonoverlapping coil elements in the transverse plane. It can cover a field of view of up to 44 × 28 cm(2) and removes the need for coil repositioning for body MRI patients with multiple clinical concerns. The 64-channel coil was compared with a 32-channel standard coil for signal-to-noise ratio and parallel imaging performances on different phantoms. With IRB approval and informed consent/assent, the designed coil was validated on 21 consecutive pediatric patients. RESULTS: The pediatric coil provided higher signal-to-noise ratio than the standard coil on different phantoms, with the averaged signal-to-noise ratio gain at least 23% over a depth of 7 cm along the cross-section of phantoms. It also achieved better parallel imaging performance under moderate acceleration factors. Good image quality (average score 4.6 out of 5) was achieved using the developed pediatric coil in the clinical studies. CONCLUSION: A 64-channel semiflexible receive-only phased array has been developed and validated to facilitate high quality pediatric body MRI at 3T. Magn Reson Med 76:1015-1021, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Pediatria/instrumentação , Transdutores , Imagem Corporal Total/instrumentação , Criança , Pré-Escolar , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
6.
Magn Reson Med ; 73(3): 1328-39, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24623586

RESUMO

PURPOSE: The concept of a "radiofrequency safety prescreen" is investigated, wherein dangerous interactions between radiofrequency fields used in MRI, and conductive implants in patients are detected through impedance changes in the radiofrequency coil. THEORY: The behavior of coupled oscillators is reviewed, and the resulting, observable impedance changes are discussed. METHODS: A birdcage coil is loaded with a static head phantom and a wire phantom with a wire close to its resonant length, the shape, position, and orientation of which can be changed. Interactions are probed with a current sensor and network analyzer. RESULTS: Impedance spectra show dramatic, unmistakable splitting in cases of strong coupling, and strong correlation is observed between induced current and scattering parameters. CONCLUSIONS: The feasibility of a new, low-power prescreening technique has been demonstrated in a simple phantom experiment, which can unambiguously detect resonant interactions between an implanted wire and an imaging coil. A new technique has also been presented which can detect parallel transmit null modes for the wire.


Assuntos
Queimaduras por Corrente Elétrica/etiologia , Queimaduras por Corrente Elétrica/prevenção & controle , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Próteses e Implantes , Contraindicações , Desenho de Equipamento , Análise de Falha de Equipamento , Segurança de Equipamentos , Humanos , Ondas de Rádio/efeitos adversos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Inorg Chem ; 53(18): 9509-15, 2014 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-25148242

RESUMO

A series of amine-functionalized mixed-linker metal-organic frameworks (MOFs) of idealized structural formula Zr6O4(OH)4(BDC)(6-6X)(ABDC)6X (where BDC = benzene-1,4-dicarboxylic acid, ABDC = 2-aminobenzene-1,4-dicarboxylic acid) has been prepared by solvothermal synthesis. The materials have been characterized by thermogravimetric analysis (TGA), powder X-ray diffraction (PXRD), and Fourier transform infrared (FTIR) spectroscopy with the aim of elucidating the effect that varying the degrees of amine functionalization has on the stability (thermal and chemical) and porosity of the framework. This work includes the first application of ultraviolet-visible light (UV-vis) spectroscopy in the quantification of ABDC in mixed-linker MOFs.

8.
Support Care Cancer ; 22(5): 1269-75, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24389826

RESUMO

PURPOSE: The aim of this study was to test the safety, tolerability and efficacy of a novel combination of an anabolic ß2-agonist and an appetite stimulant in patients with cancer cachexia. METHODS: Thirteen patients (M/F 5:8) with advanced malignancy and involuntary weight loss received oral formoterol (80 µg/day) and megestrol acetate (480 mg/day) for up to 8 weeks. Quadriceps size (MRI), quadriceps and hand-grip strength, lower limb extensor power, physical activity and quality of life were measured at baseline and at 8 weeks. Response criteria were specified pre-trial, with a major response defined as an increase in muscle size ≥ 4 % or function ≥ 10 %. RESULTS: Six patients withdrew before 8 weeks, reflecting the frail, comorbid population. In contrast, six out of seven (86 %) patients completing the course achieved a major response for muscle size and/or function. In the six responders, mean quadriceps volume increased significantly (left 0.99 vs. 1.05 L, p=0.012; right 1.02 vs. 1.06 L, p=0.004). There was a trend towards an increase in quadriceps and handgrip strength (p>0.05). The lack of appetite symptom score declined markedly (76.2 vs. 23.8; p=0.005), indicating improvement. Adverse reactions were few, the commonest being tremor (eight reports), peripheral oedema (three), tachycardia (two) and dyspepsia (two). CONCLUSIONS: In this frail cohort with advanced cancer cachexia, an 8-week course of megestrol and formoterol in combination was safe and well tolerated. Muscle mass and/or function were improved to a clinically significant extent in most patients completing the course. This combination regimen warrants further investigation in larger, randomized trials.


Assuntos
Estimulantes do Apetite/uso terapêutico , Caquexia/tratamento farmacológico , Etanolaminas/uso terapêutico , Acetato de Megestrol/uso terapêutico , Megestrol/uso terapêutico , Neoplasias/metabolismo , Agonistas de Receptores Adrenérgicos beta 2/efeitos adversos , Agonistas de Receptores Adrenérgicos beta 2/uso terapêutico , Adulto , Idoso , Anorexia/tratamento farmacológico , Anorexia/etiologia , Antropometria/métodos , Estimulantes do Apetite/efeitos adversos , Caquexia/etiologia , Terapia Combinada , Etanolaminas/efeitos adversos , Feminino , Fumarato de Formoterol , Humanos , Masculino , Megestrol/efeitos adversos , Acetato de Megestrol/efeitos adversos , Pessoa de Meia-Idade , Neoplasias/terapia , Redução de Peso/efeitos dos fármacos
9.
Scand J Med Sci Sports ; 24(1): e1-10, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24151875

RESUMO

The purpose of this review was to determine whether very elderly muscle (>75 years) hypertrophies in response to physical training. The databases MEDLINE; EMBASE; CINAHL Plus and SPORTDiscus were systematically literature searched with reference lists of all included studies and relevant reviews. Controlled trials (inactive elderly control group) involving healthy elderly participants over 75 years participating in an intervention complying with an established definition of physical training were included. Data extraction and quality assessment were performed using the PEDro scale. Data analysis was performed on muscle size and strength using RevMan (software version 5.1). Four studies were included of which four of four measured changes in gross muscle size. Training induced increases in muscle size from 1.5%-15.6% were reported in three of four studies, and one of four studies reported a decrease in muscle size (3%). The greatest gain in muscle mass was observed in a study of whole body vibration training. Meta-analysis of three studies found an increase of thigh muscle cross-sectional area (mean difference 2.31 cm(2) or 0.2%, 95% confidence interval (CI): 0.62 to 4.00; P = 0.008) and muscle strength (standardized mean difference 1.04, 95% CI: 0.65 to 1.43; P < 0.001). Physical training when delivered as resistance training has the ability to elicit hypertrophy and increase muscle strength in very elderly muscle.


Assuntos
Exercício Físico/fisiologia , Força Muscular/fisiologia , Músculo Esquelético/fisiologia , Treinamento Resistido/métodos , Sarcopenia/terapia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino
10.
Proc Biol Sci ; 280(1763): 20130584, 2013 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-23698007

RESUMO

A 'dark morph' melanic strain of the greater wax moth, Galleria mellonella, was studied for its atypical, heightened resistance to infection with the entomopathogenic fungus, Beauveria bassiana. We show that these insects exhibit multiple intraspecific immunity and physiological traits that distinguish them from a non-melanic, fungus-susceptible morph. The melanic and non-melanic morphs were geographical variants that had evolved different, independent defence strategies. Melanic morphs exhibit a thickened cuticle, higher basal expression of immunity- and stress-management-related genes, higher numbers of circulating haemocytes, upregulated cuticle phenoloxidase (PO) activity concomitant with conidial invasion, and an enhanced capacity to encapsulate fungal particles. These insects prioritize specific augmentations to those frontline defences that are most likely to encounter invading pathogens or to sustain damage. Other immune responses that target late-stage infection, such as haemolymph lysozyme and PO activities, do not contribute to fungal tolerance. The net effect is increased larval survival times, retarded cuticular fungal penetration and a lower propensity to develop haemolymph infections when challenged naturally (topically) and by injection. In the absence of fungal infection, however, the heavy defence investments made by melanic insects result in a lower biomass, decreased longevity and lower fecundity in comparison with their non-melanic counterparts. Although melanism is clearly correlated with increased fungal resistance, the costly mechanisms enabling this protective trait constitute more than just a colour change.


Assuntos
Beauveria , Proteínas de Insetos/genética , Proteínas de Insetos/metabolismo , Mariposas/imunologia , Mariposas/microbiologia , Animais , Beauveria/genética , Beauveria/fisiologia , Resistência à Doença , Fertilidade , Regulação da Expressão Gênica/imunologia , Interações Hospedeiro-Patógeno , Insetos/genética , Insetos/imunologia , Insetos/fisiologia , Larva/genética , Larva/imunologia , Larva/microbiologia , Larva/fisiologia , Melanose , Mariposas/genética , Mariposas/fisiologia
11.
Rapid Commun Mass Spectrom ; 27(15): 1769-77, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23821570

RESUMO

RATIONALE: Conventionally, myofibrillar protein synthesis is measured over time periods of hours. In clinical studies, interventions occur over weeks. Functional measures over such periods may be more representative. We aimed to develop a novel method to determine myofibrillar protein fractional synthetic rate (FSR) to estimate habitual rates, while avoiding intravenous tracer infusions. METHODS: Four healthy males were given 100 g water enriched to 70 Atom % with (2)H2O as a single oral bolus. Vastus-lateralis needle biopsies were performed and plasma samples collected, 3-13 days post-dose. (2)H enrichment in body water was measured in plasma using continuous flow isotope ratio mass spectrometry (IRMS). Myofibrillar protein was isolated from muscle biopsies and acid hydrolysed. (2)H enrichment of protein-bound and plasma-free alanine was measured by gas chromatography (GC)/pyrolysis/IRMS. Myofibrillar protein FSR was calculated (% day(-1)). RESULTS: The tracer bolus raised the initial enrichment of body water to 1514 ppm (2)H excess. Water elimination followed a simple exponential. The average elimination half-time was 8.3 days. Plasma alanine, labelled during de novo synthesis, followed the same elimination kinetics as water. The weighted average myofibrillar protein FSR from the four subjects was 1.38 % day(-1) (range, 1.0-1.9 % day(-1) ). CONCLUSIONS: Myofibrillar protein FSR was measured in free-living healthy individuals over 3-13 days. Using a single oral (2)H2O bolus, endogenous labelling of alanine occurred in a predictable manner giving estimates of synthesis comparable with published values. Furthermore, the protocol does not compromise the ability to measure other important metabolic processes such as total energy expenditure.


Assuntos
Cromatografia Gasosa/métodos , Espectrometria de Massas/métodos , Proteínas Musculares/química , Biossíntese de Proteínas , Adulto , Humanos , Cinética , Masculino , Proteínas Musculares/sangue , Proteínas Musculares/genética , Proteínas Musculares/metabolismo , Músculo Esquelético/química , Músculo Esquelético/metabolismo , Miofibrilas/química , Miofibrilas/genética , Miofibrilas/metabolismo
12.
Nat Commun ; 13(1): 4441, 2022 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-35948540

RESUMO

The achievement of the Paris Agreement climate goals of well-below 2 degrees of warming requires companies to align their greenhouse gas emission reductions with this goal. To measure whether companies are compliant with the Paris targets we propose several strict conditions that any emissions allocation methodology must meet before it can be classified as Paris-Compliant. Our conditions focus on the need for a common, and early as practicable, base year for all companies and consistency with an underlying Paris-aligned decarbonisation pathway. Additionally, we propose four operationalisation requirements to ensure companies can declare they are on a Paris Compliant Pathway including calculations of their carbon budgets and re-alignment pathways. Applying example Paris-Compliant Pathways and associated metrics to ten high emission electric utility companies and ten cement companies, we find that all but one of these companies are not currently Paris-compliant, with every year of delayed action increasing their required rate of decarbonisation and hence the exposure of billions of investment dollars to transition risk. Applying this proposed method will ensure the Paris carbon budget is met and that progress can be tracked accurately - an imperative for any companies and stakeholders seeking to align their decision-making with the Paris Agreement.


Assuntos
Mudança Climática , Gases de Efeito Estufa , Carbono , Paris
13.
Med Phys ; 48(10): 6069-6079, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34287972

RESUMO

PURPOSE: Almost one in four lumpectomies fails to fully remove cancerous tissue from the breast, requiring reoperation. This high failure rate suggests that existing lumpectomy guidance methods are inadequate for allowing surgeons to consistently identify the proper volume of tissue for excision. Current guidance techniques either provide little information about the tumor position or require surgeons to frequently switch between making incisions and manually probing for a marker placed at the lesion site. This article explores the feasibility of thermo-acoustic ultrasound (TAUS) to enable hands-free localization of metallic biopsy markers throughout surgery, which would allow for continuous visualization of the lesion site in the breast without the interruption of surgery. In a TAUS-based localization system, microwave excitations would be transmitted into the breast, and the amplification in microwave absorption around the metallic markers would generate acoustic signals from the marker sites through the thermo-acoustic effect. Detection and ranging of these signals by multiple acoustic receivers on the breast could then enable marker localization through acoustic multilateration. METHODS: Physics simulations were used to characterize the TAUS signals generated from different markers by microwave excitations. First, electromagnetic simulations determined the spatial pattern of the amplification in microwave absorption around the markers. Then, acoustic simulations characterized the acoustic fields generated from these markers at various acoustic frequencies. TAUS-based one-dimensional (1D) ranging of two metallic markers-including a biopsy marker that is FDA-approved for clinical use-immersed in saline was also performed using a bench-top setup. To perform TAUS acquisitions, a microwave applicator was driven by 2.66 GHz microwave signals that were amplitude-modulated by chirps at the desired acoustic excitation frequencies, and the resulting TAUS signal from the markers was detected by an ultrasonic transducer. RESULTS: The simulation results show that the geometry of the marker strongly impacts the quantity and spatial pattern of both the microwave absorption around the marker and the resulting TAUS signal generated from the marker. The simulated TAUS signal maps and acoustic frequency responses also make clear that the marker geometry plays an important role in determining the overall system response. Using the bench-top setup, TAUS detection and 1D localization of the markers were successfully demonstrated for multiple different combinations of microwave applicator and metallic marker. These initial results indicate that TAUS-based localization of biopsy markers is feasible. CONCLUSIONS: Through microwave excitations and acoustic detection, TAUS can be used to localize metallic biopsy markers. With further development, TAUS opens new avenues to enable a more intuitive lumpectomy guidance system that could help to achieve better lumpectomy outcomes.


Assuntos
Neoplasias da Mama , Mastectomia Segmentar , Acústica , Biópsia , Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Feminino , Humanos , Ultrassonografia
14.
Magn Reson Med ; 64(3): 823-33, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20593374

RESUMO

Patients with long-wire medical implants are currently prevented from undergoing magnetic resonance imaging (MRI) scans due to the risk of radio frequency (RF) heating. We have developed a simple technique for determining the heating potential for these implants using reversed radio frequency (RF) polarization. This technique could be used on a patient-to-patient basis as a part of the standard prescan procedure to ensure that the subject's device does not pose a heating risk. By using reversed quadrature polarization, the MR scan can be sensitized exclusively to the potentially dangerous currents in the device. Here, we derive the physical principles governing the technique and explore the primary sources of inaccuracy. These principles are verified through finite-difference simulations and through phantom scans of implant leads. These studies demonstrate the potential of the technique for sensitively detecting potentially dangerous coupling conditions before they can do any harm.


Assuntos
Queimaduras por Corrente Elétrica/etiologia , Queimaduras por Corrente Elétrica/prevenção & controle , Segurança de Equipamentos/instrumentação , Segurança de Equipamentos/métodos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/instrumentação , Próteses e Implantes/efeitos adversos , Algoritmos , Desenho Assistido por Computador , Análise de Falha de Equipamento , Humanos , Ondas de Rádio
15.
Magn Reson Med ; 64(5): 1432-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20632401

RESUMO

Parallel excitation uses multiple transmit channels and coils, each driven by independent waveforms, to afford the pulse designer an additional spatial encoding mechanism that complements gradient encoding. In contrast to parallel reception, parallel excitation requires individual power amplifiers for each transmit channel, which can be cost prohibitive. Several groups have explored the use of low-cost power amplifiers for parallel excitation; however, such amplifiers commonly exhibit nonlinear memory effects that distort radio frequency pulses. This is especially true for pulses with rapidly varying envelopes, which are common in parallel excitation. To overcome this problem, we introduce a technique for parallel excitation pulse design that yields pulses with smoother envelopes. We demonstrate experimentally that pulses designed with the new technique suffer less amplifier distortion than unregularized pulses and pulses designed with conventional regularization.


Assuntos
Amplificadores Eletrônicos , Artefatos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/instrumentação , Reconhecimento Automatizado de Padrão/métodos , Processamento de Sinais Assistido por Computador/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
16.
J Magn Reson Imaging ; 32(3): 684-91, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20815067

RESUMO

PURPOSE: To evaluate a novel soft, lightweight cushion that can match the magnetic susceptibility of human tissue. The magnetic susceptibility difference between air and tissue produces field inhomogeneities in the B(0) field, which leads to susceptibility artifacts in magnetic resonance imaging (MRI) studies. MATERIALS AND METHODS: Pyrolytic graphite (PG) microparticles were uniformly embedded into a foam cushion to reduce or eliminate field inhomogeneities at accessible air and tissue interfaces. 3T MR images and field maps of an air/water/PG foam phantom were acquired. Q measurements on a 4T tuned head coil and pulse sequence heating tests at 3T were also performed. RESULTS: The PG foam improved susceptibility matching, reduced the field perturbations in phantoms, does not heat, and is nonconductive. CONCLUSION: The susceptibility matched PG foam is lightweight, safe for patient use, adds no noise or MRI artifacts, is compatible with radiofrequency coil arrays, and improves B(0) homogeneity, which enables more robust MR studies.


Assuntos
Carbono/química , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Substâncias Viscoelásticas/química , Artefatos , Imagem Ecoplanar/métodos , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional , Teste de Materiais , Modelos Estruturais , Sensibilidade e Especificidade
17.
IEEE Trans Microw Theory Tech ; 58(5): 1297-1308, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20814450

RESUMO

A modified Cartesian feedback method called "frequency-offset Cartesian feedback" and based on polyphase difference amplifiers is described that significantly reduces the problems associated with quadrature errors and DC-offsets in classic Cartesian feedback power amplifier control systems.In this method, the reference input and feedback signals are down-converted and compared at a low intermediate frequency (IF) instead of at DC. The polyphase difference amplifiers create a complex control bandwidth centered at this low IF, which is typically offset from DC by 200-1500 kHz. Consequently, the loop gain peak does not overlap DC where voltage offsets, drift, and local oscillator leakage create errors. Moreover, quadrature mismatch errors are significantly attenuated in the control bandwidth. Since the polyphase amplifiers selectively amplify the complex signals characterized by a +90° phase relationship representing positive frequency signals, the control system operates somewhat like single sideband (SSB) modulation. However, the approach still allows the same modulation bandwidth control as classic Cartesian feedback.In this paper, the behavior of the polyphase difference amplifier is described through both the results of simulations, based on a theoretical analysis of their architecture, and experiments. We then describe our first printed circuit board prototype of a frequency-offset Cartesian feedback transmitter and its performance in open and closed loop configuration. This approach should be especially useful in magnetic resonance imaging transmit array systems.

18.
IEEE Trans Biomed Eng ; 67(3): 876-882, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31247538

RESUMO

Interventional magnetic resonance imaging (MRI) could allow for diagnosis and immediate treatment of ischemic stroke; however, such endovascular catheter-based procedures under MRI guidance are inherently difficult. One major challenge is tracking the tip of the catheter, as standard fabrication methods for building inductively coupled coil markers are rigid and bulky. Here, we report a new approach that uses aerosol jet deposition to three-dimensional (3-D) print an inductively coupled RF coil marker on a polymer catheter. Our approach enables lightweight conforming markers on polymer catheters and these low-profile markers allow the catheter to be more safely navigated in small caliber vessels. Prototype markers with an inductor with the geometry of a double helix are incorporated on catheters for in vitro studies, and we show that these markers exhibit good signal amplification. We report temperature measurements and, finally, demonstrate feasibility in a preliminary in vivo experiment. We provide material properties and electromagnetic simulation performance analysis. This paper presents fully aerosol jet-deposited and functional wireless resonant markers on polymer catheters for use in 3T clinical scanners.


Assuntos
Catéteres , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imagem por Ressonância Magnética Intervencionista/métodos , Tecnologia sem Fio/instrumentação , Animais , Desenho de Equipamento , Feminino , Suínos , Temperatura
19.
Clin Nutr ; 38(6): 2875-2880, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30612853

RESUMO

INTRODUCTION: Following the consensus definition of cancer cachexia, more studies are using CT scan analysis of truncal muscles as a marker of muscle wasting. However, how CT-derived body composition relates to function, strength and power in patients with cancer is largely unknown. AIMS: We aimed to describe the relationship between CT truncal (L3) skeletal muscle index (SMI) and MRI quadriceps cross sectional area with lower limb strength, power and measures of complex function. METHODS: Patients undergoing assessment for potentially curative surgery for oesophagogastric or pancreatic cancer were recruited from the regional upper gastrointestinal (UGI) or hepatopancreaticobiliary (HPB) multi-disciplinary team meetings. Maximum Isometric Knee Extensor Strength (IKES) and Maximum Leg Extensor Power (Nottingham Power Rig) (LEP) were used as measures of lower limb performance. Both Sit to Stand (STS) and Timed Up and Go (TUG) were used as measures of global complex muscle function. Muscle SMI was measured from routine CT scans at the level of the third lumbar vertebrae (L3) and MRI scan was used for the assessment of quadriceps muscles. Linear regression analysis was performed for CT SMI or MRI quadriceps as a predictor of each measure of performance. RESULTS: Forty-four patients underwent assessment. Height and weight were significantly related to function in terms of quadriceps power, while only weight was associated with strength (P < 0.001). CT SMI was not related to measures of quadriceps strength or power but had significant association with more complex functional measures (P = 0.006, R2 = 0.234 and 0.0019, R2 = 0.175 for STS and TUG respectively). In comparison, both gross and fat-subtracted measures of quadriceps muscle mass from MRI were significantly correlated with quadriceps strength and power (P < 0.001), but did not show any significant association with complex functional measures. CONCLUSION: CT SMI and MRI quadriceps have been shown to reflect different aspects of functional ability with CT SMI being a marker of global muscle function and MRI quadriceps being specific to quadriceps power and strength. This should therefore be considered when choosing outcome measures for trials or definitions of muscle mass and function.


Assuntos
Caquexia/complicações , Neoplasias Esofágicas/complicações , Músculo Esquelético/diagnóstico por imagem , Neoplasias Pancreáticas/complicações , Neoplasias Gástricas/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Caquexia/fisiopatologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Força Muscular/fisiologia , Músculo Esquelético/fisiologia , Músculo Quadríceps , Tomografia Computadorizada por Raios X/métodos
20.
IEEE Trans Med Imaging ; 37(2): 536-546, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29053449

RESUMO

Patients who have implanted medical devices with long conductive leads are often restricted from receiving MRI scans due to the danger of RF-induced heating near the lead tips. Phantom studies have shown that this heating varies significantly on a case-by-case basis, indicating that many patients with implanted devices can receive clinically useful MRI scans without harm. However, the difficulty of predicting RF-induced lead tip heating prior to scanning prevents numerous implant recipients from being scanned. Here, we demonstrate that thermo-acoustic ultrasound (TAUS) has the potential to be utilized for a pre-scan procedure assessing the risk of RF-induced lead tip heating in MRI. A system was developed to detect TAUS signals by four different TAUS acquisition methods. We then integrated this system with an MRI scanner and detected a peak in RF power absorption near the tip of a model lead when transmitting from the scanner's body coil. We also developed and experimentally validated simulations to characterize the thermo-acoustic signal generated near lead tips. These results indicate that TAUS is a promising method for assessing RF implant safety, and with further development, a TAUS pre-scan could allow many more patients to have access to MRI scans of significant clinical value.


Assuntos
Imageamento por Ressonância Magnética/efeitos adversos , Próteses e Implantes/efeitos adversos , Termografia/métodos , Ultrassonografia/métodos , Simulação por Computador , Desenho de Equipamento , Temperatura Alta/efeitos adversos , Humanos , Processamento de Imagem Assistida por Computador , Segurança do Paciente , Imagens de Fantasmas , Ondas de Rádio , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA