Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Mater Sci Mater Med ; 29(6): 83, 2018 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-29892952

RESUMO

Following percutaneous coronary intervention, vascular closure devices (VCDs) are increasingly used to reduce time to ambulation, enhance patient comfort, and reduce potential complications compared with traditional manual compression. Newer techniques include complicated, more or less automated suture devices, local application of pads or the use of metal clips and staples. These techniques often have the disadvantage of being time consuming, expensive or not efficient enough. The VCD failure rate in association with vascular complications of 2.0-9.5%, depending on the type of VCD, is still not acceptable. Therefore, the aim of this study is to develop a self-expanding quick vascular closure device (QVCD) made from a bioabsorbable elastic polymer that can be easily applied through the placed introducer sheath. Bioabsorbable block-co-polymers were synthesized and the chemical and mechanical degradation were determined by in vitro tests. The best fitting polymer was selected for further investigation and for microinjection moulding. After comprehensive haemocompatibility analyses in vitro, QVCDs were implanted in arterial vessels following arteriotomy for different time points in sheep to investigate the healing process. The in vivo tests proved that the new QVCD can be safely placed in the arteriotomy hole through the existing sheath instantly sealing the vessel. The degradation time of 14 days found in vitro was sufficient for vessel healing. After 4 weeks, the remaining QVCD material was covered by neointima. Overall, our experiments showed the safety and feasibility of applying this novel QVCD through an existing arterial sheath and hence encourage future work with larger calibers.


Assuntos
Artérias/diagnóstico por imagem , Cateterismo/métodos , Radiografia , Dispositivos de Oclusão Vascular , Anestesia , Animais , Materiais Biocompatíveis/química , Desenho de Equipamento , Feminino , Artéria Femoral , Hemostasia , Humanos , Inflamação , Masculino , Microscopia Eletrônica de Varredura , Polímeros/química , Pressão , Ovinos , Estresse Mecânico
2.
Br J Anaesth ; 114(6): 973-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25835025

RESUMO

BACKGROUND: Neurosurgical procedures requiring a sitting position may put the patient at risk of a potentially life-threatening air embolism. Transient manual jugular venous compression limits further air entry in this situation. This study presents an alternative technique aimed at reducing the risk of air embolism. METHODS: In an in vitro model, an intrajugular balloon catheter was inserted to demonstrate that this device prevents air embolism. In an in vivo study, this device was bilaterally placed into jugular vessels in pigs. Using an ultrasound technique, blood flow was monitored and jugular venous pressure was recorded before and during cuff inflation. Air was applied proximally to the inflated cuffs to test the hypothesis that this novel device blocks air passage. RESULTS: In vitro, the intrajugular balloon catheter reliably prevented further air entry (n=10). Additionally, accumulated air could be aspirated from an orifice of the catheter (n=10). In vivo, inflation of the catheter balloon completely obstructed venous blood flow (n=8). Bilateral inflation of the cuff significantly increased the proximal jugular venous pressure from 9.8 (2.4) mm Hg to 14.5 (2.5) mm Hg (n=8, P<0.05). Under conditions mimicking an air embolism, air passage across the inflated cuffs was prevented and 78 (20%) (n=6) of the air dose could be aspirated by the proximal orifice of the catheter. CONCLUSIONS: These findings may serve as a starting point for the development of intrajugular balloon catheters designed to reduce the risk of air embolism in patients undergoing neurosurgery in a sitting position.


Assuntos
Oclusão com Balão/métodos , Cateterismo Periférico/métodos , Embolia Aérea/prevenção & controle , Veias Jugulares , Animais , Veias Jugulares/diagnóstico por imagem , Procedimentos Neurocirúrgicos/métodos , Posicionamento do Paciente , Suínos , Ultrassonografia
3.
J Urol ; 187(3): 1101-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22266012

RESUMO

PURPOSE: In this tissue engineering study we investigated urethral stricture formation to evaluate different treatment modalities in the large animal model and validate the most current, comparable effect of human stricture development for successful human clinical application. MATERIALS AND METHODS: In 12 male minipigs stricture formation was evaluated by urethrography 1, 8 and 12 weeks after stricture induction by ligation, urethrotomy or thermocoagulation. Normal human urethral and scar tissue of 6 patients was harvested and compared to animal specimens. The effect of urethral damage was investigated for microvessel density and collagen I:III ratio. RESULTS: A week after urethrotomy urothelium covered the spongiosum tissue, showing minimal infiltration of lymphocytes and macrophages, and sporadic eosinophil granulocytes. However, increased connective tissue was observed with time as well as urethral luminal narrowing, vascular network loss (decreased microvessel density) and significantly increased collagen with a favorably revised collagen type I:III ratio. The 3 methods of stricture induction resulted in different stricture severity in the animal model (thermocoagulation >ligation >urethrotomy). Porcine urethral samples after thermocoagulation showed a significantly increased collagen I:III ratio (p <0.001), almost equal to that of human urethral stricture specimens. CONCLUSIONS: We successfully developed a large animal model in which to study urethral stricture formation by defined iatrogenic intervention. The established animal model advances investigation to evaluate new therapy modalities in a preclinical setting to treat urethral stricture and predict clinical outcome.


Assuntos
Modelos Animais de Doenças , Estreitamento Uretral/terapia , Adulto , Idoso , Animais , Western Blotting , Humanos , Doença Iatrogênica , Imuno-Histoquímica , Masculino , Microscopia , Pessoa de Meia-Idade , Suínos , Porco Miniatura , Engenharia Tecidual , Estreitamento Uretral/etiologia , Estreitamento Uretral/patologia
4.
Br J Anaesth ; 108(6): 912-21, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22369765

RESUMO

BACKGROUND: Extracorporeal circulation (ECC) and hypothermia are routinely used in cardiac surgery to maintain stable circulatory parameters and to increase the ischaemic tolerance of the patient. However, ECC and hypothermia cause platelet activation and dysfunction possibly followed by a devastating coagulopathy. Stimulation of the adenosinediphosphate (ADP) receptor P(2)Y(12) plays a pivotal role in platelet activation. This experimental study tested P(2)Y(12) receptor blockade as an approach to protect platelets during ECC. METHODS: Human blood was treated with the short-acting P(2)Y(12) blocker cangrelor (1 µM, t(1/2)<5 min) or the P(2)Y(12) inhibitor 2-MeSAMP (100 µM) and circulated in an ex vivo ECC model at normothermia (37°C) and hypothermia (28°C). Before and after circulation, markers of platelet activation and of coagulation (thrombin-antithrombin complex generation) were analysed. During hypothermic ECC in pigs, the effect of reversible P(2)Y(12) blockade on platelet function was evaluated by cangrelor infusion (0.075 µg kg(-1) min(-1)). RESULTS: During ex vivo hypothermic ECC, P(2)Y(12) blockade inhibited platelet granule release (P<0.01), platelet-granulocyte binding (P<0.05), and platelet loss (P<0.001), whereas no effects on platelet-ECC binding, platelet CD42bα expression, glycoprotein IIb/IIIa activation, or thrombin-antithrombin complex generation were observed. During hypothermic ECC in pigs, cangrelor inhibited platelet-fibrinogen binding (P<0.05) and ADP-induced platelet aggregation (P<0.001). Platelet function was rapidly restored after termination of cangrelor infusion. CONCLUSIONS: P(2)Y(12) blockade by cangrelor prevents platelet activation during ECC and hypothermia. Owing to its short half-life, platelet inhibition can be well controlled, thus potentially reducing bleeding complications. This novel pharmacological strategy has the potential to reduce complications associated with ECC and hypothermia.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Transtornos da Coagulação Sanguínea/prevenção & controle , Plaquetas/efeitos dos fármacos , Circulação Extracorpórea , Hipotermia Induzida , Antagonistas do Receptor Purinérgico P2Y/farmacologia , Difosfato de Adenosina/sangue , Monofosfato de Adenosina/farmacologia , Animais , Antitrombina III/metabolismo , Plaquetas/fisiologia , Ponte Cardiopulmonar , Grânulos Citoplasmáticos/efeitos dos fármacos , Humanos , Peptídeo Hidrolases/metabolismo , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/efeitos dos fármacos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/fisiologia , Complexo Glicoproteico GPIb-IX de Plaquetas/análise , Suínos
5.
Perfusion ; 27(1): 21-9, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22002965

RESUMO

INTRODUCTION: Di(2-ethylhexyl)phthalate (DEHP) is suspected to be toxic for several reasons. During contact with a lipophilic medium, DEHP leaks from polyvinylchloride (PVC), but its influence on inflammatory reactions remains unknown. We examined specific DEHP leaching out of different tubing types, the possibly modulated liberation of proinflammatory cytokines and the induction of adhesion molecule expression in primary endothelial cells. MATERIALS AND METHODS: Blood samples were circulated in traditional PVC, nodioctyl phthalate (DOP) PVC and heparin-coated PVC tubing within a Chandler loop model. The blood was tested for the concentration of DEHP and its active metabolites as well as the liberation of the proinflammatory cytokines TNFα and IL1ß. Furthermore, we exposed human endothelial cells to circulated blood and analysed them for the expression of the adhesion molecules ICAM-1, VCAM-1 and E-selectin. RESULTS: In contrast to the other tubing, PVC tubing showed significantly elevated DEHP levels, but no alteration was observed concerning a potential up-regulation of the cytokines or activation of the endothelial adhesion molecule receptors. CONCLUSIONS: Our data conclude that there is no correlation between DEHP leaching and the inflammatory response after ECC support, but this study showed that even DEHP-free material is leaching DEHP and its toxic metabolites.


Assuntos
Moléculas de Adesão Celular/metabolismo , Citocinas/metabolismo , Dietilexilftalato/efeitos adversos , Endotélio Vascular/metabolismo , Circulação Extracorpórea/instrumentação , Cloreto de Polivinila/efeitos adversos , Adulto , Células Cultivadas , Dietilexilftalato/sangue , Dietilexilftalato/farmacologia , Selectina E/metabolismo , Endotélio Vascular/citologia , Endotélio Vascular/efeitos dos fármacos , Feminino , Humanos , Molécula 1 de Adesão Intercelular/metabolismo , Interleucina-18/metabolismo , Masculino , Fator de Necrose Tumoral alfa/metabolismo , Regulação para Cima , Molécula 1 de Adesão de Célula Vascular/metabolismo
6.
J Cardiovasc Surg (Torino) ; 52(2): 251-9, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21460776

RESUMO

AIM: Coronary artery bypass grafting (CABG) is a standard procedure for treatment of coronary heart disease. Eighty percent of all CABGs are performed with venous grafts which then get exposed to an arterial pressure after surgery. This widely used procedure, however, is complicated by the development of alterations in the vein graft wall, leading to a decreased patency rate and graft failure. This study enlightens the influence of an even moderate arterial pressure on the gene expression of adhesion molecules in venous grafts which play a decisive role for the early induction of atherogenesis. METHODS: Segments of porcine vena jugularis and arteria carotis were mounted in a simulated bypass circuit and subjected to pulsatile flow. Vessel segments were examined for adhesion molecule expression with quantitative real-time - polymerase chain reaction (qRT-PCR) and adherence of leukocytes was observed by confocal laser scanning microscopy and scanning electron microscopy. RESULTS: Veins grafts subjected to an even moderate arterial pressure showed a 14-fold increase of ICAM-1 expression already after 4 hours. An arterial pressure of around 100/80 mmHg was enough to stimulate the adhesion molecule expression Furthermore it led to a 9-fold increase of leukocyte adhesion to the venous endothelium, but, in contrast this was not the case in arteries. CONCLUSION: This study showed, that already 100 mmHg upregulates the expression of several adhesion molecules in pig veins followed by increased adhesion of leukocytes. Therefore, our data demonstrate the advantage of arteries for CABG, and that new therapeutic strategies are urgently necessary to protect vein grafts either physically or pharmacologically if arteries are not available for CABG.


Assuntos
Pressão Sanguínea , Artérias Carótidas/imunologia , Moléculas de Adesão Celular/metabolismo , Ponte de Artéria Coronária/efeitos adversos , Veias Jugulares/imunologia , Animais , Adesão Celular , Moléculas de Adesão Celular/genética , Selectina E/metabolismo , Feminino , Regulação da Expressão Gênica , Técnicas In Vitro , Molécula 1 de Adesão Intercelular/metabolismo , Veias Jugulares/transplante , Leucócitos/imunologia , Microscopia Confocal , Microscopia Eletrônica de Varredura , Perfusão , Fluxo Pulsátil , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Suínos , Fatores de Tempo , Molécula 1 de Adesão de Célula Vascular/metabolismo
7.
Rofo ; 179(10): 1009-15, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17879173

RESUMO

PURPOSE: Mesenchymal stem cells (MSC) seem to be a promising cell source for cellular cardiomyoplasty. We recently developed a new aptamer-based specific selection of MSC to provide "ready to transplant" cells directly after isolation. We evaluated MRI tracking of newly isolated and freshly transplanted MSC in the heart using one short ex vivo selection step combining specific aptamer-based isolation and labeling of the cells. MATERIALS AND METHODS: Bone marrow (BM) was collected from healthy pigs. The animals were euthanized and the heart was placed in a perfusion model. During cold ischemia, immunomagnetic isolation of MSC from the BM by MSC-specific aptamers labeled with Dynabeads was performed within 2 h. For histological identification the cells were additionally stained with PKH26. Approx. 3 x 10(6) of the freshly aptamer-isolated cells were injected into the ramus interventricularis anterior (RIVA) and 5 x 10(5) cells were injected directly into myocardial tissue after damaging the respective area by freezing (cryo-scar). 3 x 10(6) of the aptamer-isolated cells were kept for further characterization (FACS and differentiation assays). 20 h after cell transplantation, MRI of the heart using a clinical 3.0 Tesla whole body scanner (Magnetom Trio, Siemens, Germany) was performed followed by histological examinations. RESULTS: The average yield of sorted cells from 120 ml BM was 7 x 10(6) cells. The cells were cultured and showed MSC-like properties. MRI showed reproducible artifacts within the RIVA-perfusion area and the cryo-scar with surprisingly excellent quality. The histological examination of the biopsies showed PKH26-positive cells within the areas which were positive in the MRI in contrast to the control biopsies. CONCLUSION: Immunomagnetic separation of MSC by specific aptamers linked to magnetic particles is feasible, effective and combines a specific separation and labeling technique to a "one stop shop" strategy.


Assuntos
Aptâmeros de Nucleotídeos , Cardiomioplastia , Imageamento por Ressonância Magnética , Transplante de Células-Tronco Mesenquimais , Células-Tronco Mesenquimais , Animais , Células da Medula Óssea , Cardiomioplastia/métodos , Separação Celular , Estudos de Viabilidade , Corantes Fluorescentes , Separação Imunomagnética , Células-Tronco Mesenquimais/citologia , Isquemia Miocárdica , Compostos Orgânicos , Coloração e Rotulagem , Suínos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA