Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Ultrasound Obstet Gynecol ; 63(3): 385-391, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37676105

RESUMO

OBJECTIVES: It has been suggested previously that the presence of Probst bundles (PB) in cases with a short corpus callosum (SCC) on diffusion tensor imaging (DTI) may help to differentiate between corpus callosal (CC) dysplasia and a variant of normal CC development. The objectives of this study were to compare DTI parameters between cases of SCC vs normal CC and between cases of SCC with PB (SCC-PB+) vs SCC without PB (SCC-PB-). METHODS: This was a retrospective study of patients referred to the Necker Hospital in Paris, France, for magnetic resonance imaging (MRI) evaluation of an apparently isolated SCC detected by sonography between November 2016 and December 2022 (IRB: 00011928). MRI was performed using a 1.5-Tesla Signa system. T2-weighted axial and sagittal sequences of the fetal brain were used to measure the length and thickness of the CC. 16-direction DTI axial brain sequences were performed to identify the presence of PB and to generate quantitative imaging parameters (fractional anisotropy (FA) and apparent diffusion coefficient (ADC)) of the entire CC, genu, body and splenium. Cases in which other associated brain abnormalities were detected on MRI were excluded. Cases were matched for fetal gender and gestational age with controls in a 1:3 ratio. Control cases were normal fetuses included in the LUMIERE on the FETUS trial (NCT04142606) that underwent the same DTI evaluation of the brain. Comparisons between SCC and normal CC cases, and between SCC-PB+ and SCC-PB- cases were performed using ANOVA and adjusted for potential confounders using ANCOVA. RESULTS: Twenty-two SCC cases were included and compared with 66 fetuses with a normal CC. In 10/22 (45.5%) cases of SCC, PB were identified. As expected, dimensions of the CC were significantly smaller in SCC compared with normal CC cases (all P < 0.01). In SCC-PB+ vs SCC-PB- cases, FA values were significantly lower in the entire CC (median, 0.21 (range, 0.19-0.24) vs 0.24 (range, 0.22-0.28); P < 0.01), genu (median, 0.21 (range, 0.15-0.29) vs 0.24 (range, 0.17-0.29); P = 0.04), body (median, 0.21 (range, 0.18-0.23) vs 0.23 (range, 0.21-0.27); P = 0.04) and splenium (median, 0.22 (range, 0.16-0.30) vs 0.25 (range, 0.20-0.29); P = 0.03). ADC values were significantly higher in the entire CC, genu and body in SCC-PB+ vs SCC-PB- cases (all P < 0.05). In SCC-PB+ cases, all FA values were significantly lower, and ADC values in the CC body were significantly higher compared with normal CC cases (all P < 0.05). In SCC-PB- cases, there was no significant difference in FA and ADC compared with normal CC cases (all P > 0.05). CONCLUSIONS: Fetal DTI evaluation of the CC showed that FA values were significantly lower and ADC values tended to be significantly higher in SCC-PB+ compared with normal CC cases. This may highlight alterations of the white matter microstructure in SCC-PB+. In contrast, isolated SCC-PB- did not demonstrate significant changes in DTI parameters, strengthening the possibility that this is a normal CC variant. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Corpo Caloso , Imagem de Tensor de Difusão , Feminino , Humanos , Gravidez , Corpo Caloso/diagnóstico por imagem , Imageamento por Ressonância Magnética , Cuidado Pré-Natal , Estudos Retrospectivos , Ensaios Clínicos como Assunto
2.
Ultrasound Obstet Gynecol ; 63(4): 472-480, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-37743665

RESUMO

OBJECTIVES: Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) facilitates the non-invasive in-vivo evaluation of placental oxygenation. The aims of this study were to identify and quantify a relative BOLD effect in response to hyperoxia in the human placenta and to compare it between pregnancies with and those without fetal growth restriction (FGR). METHODS: This was a prospective multicenter study (NCT02238301) of 19 pregnancies with FGR (estimated fetal weight (EFW) on ultrasound < 5th centile) and 75 non-FGR pregnancies (controls) recruited at two centers in Paris, France. Using a 1.5-Tesla MRI system, the same multi-echo gradient-recalled echo (GRE) sequences were performed at both centers to obtain placental T2* values at baseline and in hyperoxic conditions. The relative BOLD effect was calculated according to the equation 100 × (hyperoxic T2* - baseline T2*)/baseline T2*. Baseline T2* values and relative BOLD effect were compared according to EFW (FGR vs non-FGR), presence/absence of Doppler anomalies and birth weight (small-for-gestational age (SGA) vs non-SGA). RESULTS: We observed a relative BOLD effect in response to hyperoxia in the human placenta (median, 33.8% (interquartile range (IQR), 22.5-48.0%)). The relative BOLD effect did not differ significantly between pregnancies with and those without FGR (median, 34.4% (IQR, 24.1-48.5%) vs 33.7% (22.7-47.4%); P = 0.95). Baseline T2* Z-score adjusted for gestational age at MRI was significantly lower in FGR pregnancies compared with non-FGR pregnancies (median, -1.27 (IQR, -4.87 to -0.10) vs 0.33 (IQR, -0.81 to 1.02); P = 0.001). Baseline T2* Z-score was also significantly lower in those pregnancies that subsequently delivered a SGA neonate (n = 23) compared with those that delivered a non-SGA neonate (n = 62) (median, -0.75 (IQR, -3.48 to 0.29) vs 0.35 (IQR, -0.79 to 1.05); P = 0.01). CONCLUSIONS: Our study confirms a BOLD effect in the human placenta and that baseline T2* values are significantly lower in pregnancies with FGR. Further studies are needed to evaluate whether such parameters may detect placental insufficiency before it has a clinical impact on fetal growth. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Hiperóxia , Placenta , Recém-Nascido , Gravidez , Feminino , Humanos , Placenta/diagnóstico por imagem , Estudos Prospectivos , Retardo do Crescimento Fetal/diagnóstico por imagem , Recém-Nascido Pequeno para a Idade Gestacional , Peso Fetal , Idade Gestacional , Ultrassonografia Pré-Natal/métodos
3.
Artigo em Inglês | MEDLINE | ID: mdl-38348601

RESUMO

OBJECTIVES: T2*-weighted sequences have been identified as non-invasive tools to study the placental oxygenation in-vivo. This study aims to investigate both static and dynamic responses to hyperoxia of the normal placenta across gestation. METHODS: We conducted a single-center prospective study including 52 uncomplicated pregnancies. Two T2*-weighted sequences were performed: T2*-relaxometry was performed before and after maternal hyperoxia. The histogram distribution of T2* values was assessed by fitting a gamma distribution as T2*~Γ(αß). A dynamic acquisition (BOLD protocol) was also performed before and during oxygen supply, until placental oxygen saturation. The signal change over time was modeled using a sigmoid function, used to determine the intensity of enhancement (∆BOLD,%), a temporal variation coefficient (λ,min-1 , controlling the slope of the curve), and the maximal steepness (Vmax, ∆BOLD.min-1 ) of placental enhancement. RESULTS: The histogram analysis of the T2* values in normoxia showed a whole-placenta variation, with a decreasing linear trend in the mean T2* value (R= -0.83, 95% CI [-0.9, -0.71], p<0.001) along with a more peaked and narrower distribution of T2* values across gestation. After maternal hyperoxia, the mean T2* ratios (mean T2*hyperoxia / mean T2*baseline ) were positively correlated with gestational age, while the other histogram parameters remained stable, suggesting a translation of the histogram towards higher values with a similar aspect. The ∆BOLD showed a non-linear increase across gestation. Conversely, the λ(min-1 ) parameter, showed an inverted trend across gestation, with a significantly weaker correlation (R = -0.33, 95% CI [-0.58, -0.02], p=0.04, R2 = 0.1). As a combination of ∆BOLD and λ, the changes in Vmax throughout gestation were mainly influenced by the changes in ∆BOLD and resulted in a positive non-linear correlation with gestational age. CONCLUSION: Our results suggest that the decrease in the T2* placental signal over gestation does not reflect a dysfunction. The BOLD effect, representative of a free-diffusion model of oxygenation, highlights the growing differences in oxygen saturation between mother and fetus across gestation (∆BOLD), and placental permeability to oxygen (λ). This article is protected by copyright. All rights reserved.

4.
Ultrasound Obstet Gynecol ; 62(2): 175-184, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36864530

RESUMO

OBJECTIVE: Adequate reference ranges of size of the corpus callosum (CC) are necessary to improve characterization of CC abnormalities and parental counseling. The objective of this study was to evaluate the methodology used in studies developing references charts for CC biometry. METHODS: We conducted a systematic review of studies on fetal CC biometry using a set of predefined quality criteria of study design, statistical analysis and reporting methods. We included observational studies whose primary aim was to create ultrasound or magnetic resonance imaging charts for CC size in a normal population of fetuses. Studies were scored against a predefined set of independently agreed methodological criteria, and an overall quality score was given for each study. RESULTS: Twelve studies met the inclusion criteria. Quality scores ranged between 17.4% and 95.7%. The greatest potential for bias was noted for the following items: sample selection and sample-size calculation, as only 17% of the studies were population-based and had consecutive or random recruitment of patients and with a justification of the sample size; number of measurements obtained for CC biometry, as only 17% of the studies performed more than one measurement per fetus and per scan; and description of characteristics of the study population, as only 8% of the studies clearly reported a minimum dataset of demographic characteristics. CONCLUSIONS: Our review demonstrates substantial heterogeneity in methods and final biometric values of the fetal CC across the evaluated studies. The use of uniform methodology of the highest quality is essential in order to define a 'short' CC and provide appropriate parental counseling. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Corpo Caloso , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Corpo Caloso/diagnóstico por imagem , Idade Gestacional , Ultrassonografia Pré-Natal/métodos , Valores de Referência , Biometria/métodos , Feto/diagnóstico por imagem
5.
Ultrasound Obstet Gynecol ; 62(2): 241-247, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36971038

RESUMO

OBJECTIVES: Diffusion tensor imaging (DTI) of the fetal brain is a relatively new technique that allows evaluation of white matter tracts of the central nervous system throughout pregnancy, as well as in certain pathological conditions. The objectives of this study were to evaluate the feasibility of DTI of the spinal cord in utero and to examine gestational-age (GA)-related changes in DTI parameters during pregnancy. METHODS: This was a prospective study conducted between December 2021 and June 2022 in the LUMIERE Platform, Necker-Enfants Malades Hospital, Paris, France, as part of the LUMIERE SUR LE FETUS trial. Women with a pregnancy between 18 and 36 weeks of gestation without fetal or maternal abnormality were eligible for inclusion. Sagittal diffusion-weighted scans of the fetal spine were acquired, without sedation, using a 1.5-Tesla magnetic resonance imaging scanner. The imaging parameters were as follows: 15 non-collinear direction diffusion-weighted magnetic-pulsed gradients with a b-value 700 s/mm2 and one B0 image without diffusion-weighting; slice thickness, 3 mm; field of view (FOV), 36 mm; phase FOV, 1.00; voxel size, 4.5 × 2.8 × 3 mm3 ; number of slices, 7-10; repetition time, 2800 ms; echo time, minimum; and total acquisition time, 2.3 min. DTI parameters, including fractional anisotropy (FA) and apparent diffusion coefficient (ADC), were extracted at the cervical, upper thoracic, lower thoracic and lumbar levels of the spinal cord. Cases with motion degradation and those with aberrant reconstruction of the spinal cord on tractography were excluded. Pearson's correlation analysis was performed to evaluate GA-related changes of DTI parameters during pregnancy. RESULTS: During the study period, 42 pregnant women were included at a median GA of 29.3 (range, 22.0-35.7) weeks. Five (11.9%) patients were not included in the analysis because of fetal movement. Two (4.8%) patients with aberrant tractography reconstruction were also excluded from analysis. Acquisition of DTI parameters was feasible in all remaining cases (35/35). Increasing GA correlated with increasing FA averaged over the entire fetal spinal cord (r, 0.37; P < 0.01), as well as at the individual cervical (r, 0.519; P < 0.01), upper thoracic (r, 0.468; P < 0.01), lower thoracic (r, 0.425; P = 0.02) and lumbar (r, 0.427; P = 0.02) levels. There was no correlation between GA and ADC averaged over the entire spinal cord (r, 0.01; P = 0.99) or at the individual cervical (r, -0.109; P = 0.56), upper thoracic (r, -0.226; P = 0.22), lower thoracic (r, -0.052; P = 0.78) or lumbar (r, -0.11; P = 0.95) levels. CONCLUSIONS: This study shows that DTI of the spinal cord is feasible in normal fetuses in typical clinical practice and allows extraction of DTI parameters of the spinal cord. There is a significant GA-related change in FA in the fetal spinal cord during pregnancy, which may result from decreasing water content as observed during myelination of fiber tracts occurring in utero. This study may serve as a basis for further investigation of DTI in the fetus, including research into its potential in pathological conditions that impact spinal cord development. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Imagem de Tensor de Difusão , Substância Branca , Humanos , Feminino , Gravidez , Imagem de Tensor de Difusão/métodos , Estudos Prospectivos , Estudos de Viabilidade , Medula Espinal/diagnóstico por imagem , Medula Espinal/patologia
6.
Ultrasound Obstet Gynecol ; 60(4): 470-476, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35561129

RESUMO

Human brain development is a complex process that begins in the third week of gestation. During early development, the fetal brain undergoes dynamic morphological changes. These changes result from events such as neurogenesis, neuronal migration, synapse formation, axonal growth and myelination. Disruption of any of these processes is thought to be responsible for a wide array of different pathologies. Recent advances in magnetic resonance imaging, especially diffusion-weighted imaging and diffusion tensor imaging (DTI), have enabled characterization and evaluation of brain development in utero. In this review, aimed at practitioners involved in fetal medicine and high-risk pregnancies, we provide a comprehensive overview of fetal DTI studies focusing on characterization of early normal brain development as well as evaluation of brain pathology in utero. We also discuss the reliability and limitations of fetal brain DTI. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Encéfalo , Imagem de Tensor de Difusão , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Gravidez , Reprodutibilidade dos Testes
7.
Ultrasound Obstet Gynecol ; 59(2): 153-161, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34396620

RESUMO

OBJECTIVE: To evaluate the postnatal outcome of children with a prenatal diagnosis of apparently isolated agenesis of the septum pellucidum (ASP). METHODS: A retrospective cohort study of cases of prenatally diagnosed ASP followed in two tertiary centers and a meta-analysis combining data from the cohort study with data from published studies identified in a systematic review were carried out. Only cases with apparently isolated ASP on antenatal ultrasound and/or magnetic resonance imaging and with available postnatal follow-up data were considered eligible for inclusion. The following outcomes were analyzed: incidence of chromosomal anomalies, agreement between antenatal and postnatal findings, overall incidence of septo-optic dysplasia (SOD) and incidence of major neurological disability (motor, language, coordination or behavioral disorder or epilepsy) in non-SOD children. The incidence of SOD in infants with apparently normal optic pathways on antenatal imaging was also evaluated. RESULTS: Fifteen cases of isolated ASP, with median postnatal follow-up of 36 months (range, 12-60 months), were selected from the two centers. Six previously published studies met the inclusion criteria for the systematic review and a total of 78 cases were eligible for the analysis, including the 15 cases from our series. Genetic tests were carried out antenatally in 30 fetuses, of which two had an abnormal result (pooled proportion, 9.0% (95% CI, 1.8-20.7%); I2 = 0%). Additional or discordant imaging findings were noted postnatally in 9/70 (pooled proportion, 13.7% (95% CI, 3.5-29.0%); I2 = 63.9%) cases. Of all 78 neonates with available follow-up, SOD was diagnosed postnatally in 14 (pooled proportion, 19.4% (95% CI, 8.6-33.2%); I2 = 51.2%). In 60 cases, the optic pathways were considered to be normal on antenatal imaging, and six of these (pooled proportion, 9.1% (95% CI, 1.1-24.0%); I2 = 62.0%) were diagnosed postnatally with SOD. Of the 46 infants with available neurological follow-up who were not affected by SOD, a major neurological disability was diagnosed in three (pooled proportion, 6.5% (95% CI, 0.5-18.6%); I2 = 40.1%). CONCLUSIONS: In the vast majority of cases with a prenatal diagnosis of apparently isolated ASP, the prognosis is favorable. However, an additional anomaly is detected after birth in about 14% of cases and has a negative impact on clinical outcome. Detailed antenatal assessment of the brain and optic pathways is strongly recommended in order to identify the presence of associated anomalies. Antenatal visualization of apparently normal optic pathways does not rule out SOD. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Diagnóstico Pré-Natal/métodos , Displasia Septo-Óptica/diagnóstico por imagem , Septo Pelúcido/anormalidades , Septo Pelúcido/diagnóstico por imagem , Estudos de Coortes , Feminino , Feto/diagnóstico por imagem , Humanos , Gravidez , Displasia Septo-Óptica/patologia , Ultrassonografia Pré-Natal
8.
Ultrasound Obstet Gynecol ; 58(1): 11-18, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32798278

RESUMO

OBJECTIVE: Fetal anomalies of the corpus callosum (CC) have been reported in the prenatal imaging literature since 1985, and, especially when isolated, pose challenges for both the patient and fetal medicine specialist. The purpose of this study was to review systematically the literature on prenatally diagnosed abnormalities of the CC, focusing on the terminology used to describe abnormalities other than complete agenesis of the CC, and to assess the heterogeneity of the nomenclature and definitions used. METHODS: This study was conducted in accordance with the PRISMA statement for reporting systematic reviews. A literature search was performed to identify prospective or retrospective case series or cohort studies, published in English, French, Italian, German or Spanish, reporting fetal imaging findings and describing anomalies of the CC. Quality and risk of bias of the studies were evaluated using the Newcastle-Ottawa scale and a modification of the scale developed by Conde-Agudelo et al. for other fetal imaging studies. The data extracted included the number of patients, the number of different anomalies identified, the descriptive names of the anomalies, and, where applicable, the definitions of the anomalies, the number of cases of each type of anomaly and the biometric charts used. Secondary tests used to confirm the diagnosis, as well as the postnatal or post-termination tests used to ascertain the diagnosis, were also recorded. RESULTS: The search identified 998 records, and, after review of titles and abstracts and full review of 45 papers, 27 studies were included initially in the review, of which 24 were included in the final analysis. These 24 studies had a broad range of quality and risk of bias and represented 1135 cases of CC anomalies, of which 49% were complete agenesis and the remainder were described using the term partial agenesis or nine other terms, of which five had more than one definition. CONCLUSIONS: In comparison to the postnatal literature, in the prenatal literature there is much greater heterogeneity in the nomenclature and definition of CC anomalies other than complete agenesis. This heterogeneity and lack of standard definitions in the prenatal literature make it difficult to develop large multicenter pooled cohorts of patients who can be followed in order to develop a better understanding of the genetic associations and neurodevelopmental and psychological outcomes of patients with CC anomalies. As this information is important to improve counseling of these patients, a good first step towards this goal would be to develop a simpler categorization of prenatal CC anomalies that matches better the postnatal literature. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Agenesia do Corpo Caloso/embriologia , Corpo Caloso/embriologia , Feto/diagnóstico por imagem , Diagnóstico Pré-Natal , Terminologia como Assunto , Agenesia do Corpo Caloso/diagnóstico por imagem , Corpo Caloso/diagnóstico por imagem , Feminino , Feto/embriologia , Humanos , Gravidez , Estudos Prospectivos , Estudos Retrospectivos
9.
BJOG ; 127(3): 355-362, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31505103

RESUMO

OBJECTIVE: To define the predictive value (PV) of known prognostic factors of fetal infection with Cytomegalovirus following maternal primary infection <14 weeks of gestation, at different time points of pregnancy: the end of the second trimester; following prenatal magnetic resonance imaging (MRI) at 32 weeks of gestation; and using all ultrasound scans performed in the third trimester (US3rdT). DESIGN: A retrospective study. SETTING: Reference fetal medicine unit. POPULATION: Sixty-two fetuses infected <14 weeks of gestation. METHODS: We defined second-trimester assessment (STA) as the combination of ultrasound findings <28 weeks of gestation and fetal platelet count at cordocentesis. Three groups were defined: normal, extracerebral, and cerebral STA. MAIN OUTCOME MEASURES: For each group, the PV of STA alone, STA + MRI, and STA + US3rdT were assessed retrospectively. Outcome at birth and at follow-up were reported. RESULTS: The STA was normal, and with extracerebral and cerebral features, in 43.5, 42.0, and 14.5%, respectively. The negative PV of normal STA and MRI for moderate to severe sequelae was 100%. The residual risk was unilateral hearing loss in 16.7% of cases. Of pregnancies with cerebral STA, 44% were terminated. Following extracerebral STA, 48% of neonates were symptomatic and 30% had moderate to severe sequelae. In those cases, the positive and negative PV of MRI for sequelae were 33 and 73%, respectively. STA + US3rdT had a lower negative PV than MRI for symptoms at birth and for moderate to severe sequelae. Any false-positive findings at MRI were mostly the result of hypersignals of white matter. CONCLUSIONS: Serial assessment in the second and third trimesters by ultrasound and MRI is necessary to predict the risk of sequelae occurring in 35% of pregnancies following fetal infection in the first trimester of pregnancy. TWEETABLE ABSTRACT: Serial ultrasound prognostic assessment following fetal CMV infection in the 1st trimester is improved by MRI at 32 weeks.


Assuntos
Encéfalo/diagnóstico por imagem , Infecções por Citomegalovirus , Citomegalovirus/isolamento & purificação , Doenças Fetais , Imageamento por Ressonância Magnética/métodos , Polimicrogiria , Complicações Infecciosas na Gravidez , Ultrassonografia Pré-Natal/métodos , Aborto Eugênico/estatística & dados numéricos , Adulto , Autopsia , Infecções por Citomegalovirus/diagnóstico , Infecções por Citomegalovirus/epidemiologia , Feminino , Doenças Fetais/etiologia , Doenças Fetais/patologia , França , Humanos , Lactente , Recém-Nascido , Masculino , Polimicrogiria/etiologia , Polimicrogiria/patologia , Valor Preditivo dos Testes , Gravidez , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/epidemiologia , Trimestres da Gravidez , Prognóstico
10.
Ultrasound Obstet Gynecol ; 56(1): 86-95, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31006924

RESUMO

OBJECTIVES: Incompatibility between currently available fetoscopes and the anatomical constraints of the distended fetal bladder, with the resulting curvature around the bladder neck, account for most technical difficulties during fetal cystoscopy in lower urinary tract obstruction (LUTO). The aim of this anatomical study was to assess by magnetic resonance imaging (MRI) the variation in three bladder angles (bladder-neck angle (BNA), vesicourethral angle (VUA) and angle between bladder dome and posterior urethra (DUA)), according to gestational age (GA), bladder volume and the presence of LUTO. METHODS: From our fetal medicine database, we retrieved for review 46 MRI examinations of male fetuses between 2015 and 2019, including 17 with LUTO, examined at a mean GA of 28.1 (range, 17.3-35.0) weeks and 29 age-matched controls, examined at 29.9 (range, 21.9-35.0) weeks. We measured bladder volume, bladder-wall thickness and the three bladder angles, and used the Mann-Whitney U-test to compare values between groups. Variations according to GA and bladder volume were determined using analysis of variance (ANOVA). A reliability study was performed using the Bland-Altman method and Lin's correlation coefficient was calculated. RESULTS: Both bladder volume and bladder-wall thickness were significantly greater in the LUTO group (P < 0.01). BNA was significantly larger in LUTO compared with control fetuses: the mean (range) was 127.1° (101.6-161.6°) vs 111.2° (88.5-157.3°) (P < 0.01). DUA averaged 117° and showed no difference between the groups (P = 0.92). No statistical comparison was performed on VUA since this was not measurable in most control fetuses. ANOVA showed no variation of any angle with bladder volume in both LUTO fetuses and control fetuses. BNA in LUTO fetuses was the only angle to vary with GA, being larger after, compared with at or before, 25 weeks (P = 0.04). The reliability study showed an acceptable bias for both intra- and interobserver reproducibility for all three angles. CONCLUSION: The findings that BNA is increased by approximately 15° in fetuses with LUTO and DUA averages 117° could aid in development of a customized fetal cystoscope and help to overcome the current technical challenges of fetal cystoscopy. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Diagnóstico Pré-Natal , Obstrução do Colo da Bexiga Urinária/diagnóstico por imagem , Adulto , Biometria , Estudos de Casos e Controles , Cistoscopia/métodos , Feminino , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética , Masculino , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal , Obstrução do Colo da Bexiga Urinária/congênito
16.
J Med Genet ; 51(7): 429-35, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24793058

RESUMO

Mitochondrial diseases are characterised by a broad clinical and genetic heterogeneity that makes diagnosis difficult. Owing to the wide pattern of symptoms in mitochondrial disorders and the constantly growing number of disease genes, their genetic diagnosis is difficult and genotype/phenotype correlations remain elusive. Brain MRI appears as a useful tool for genotype/phenotype correlations. Here, we summarise the various combinations of MRI lesions observed in the most frequent mitochondrial respiratory chain deficiencies so as to direct molecular genetic test in patients at risk of such diseases. We believe that the combination of brain MRI features is of value to support respiratory chain deficiency and direct molecular genetic tests.


Assuntos
Encéfalo/metabolismo , Complexo de Proteínas da Cadeia de Transporte de Elétrons/deficiência , Doenças Mitocondriais/patologia , Encéfalo/patologia , Estudos de Associação Genética , Humanos , Imageamento por Ressonância Magnética , Doenças Mitocondriais/metabolismo , Neuroimagem , Ubiquinona/deficiência
17.
Rev Neurol (Paris) ; 171(1): 45-57, 2015 Jan.
Artigo em Francês | MEDLINE | ID: mdl-25555853

RESUMO

Moya-Moya disease is a rare arterial occlusive disease affecting the internal carotid artery and its branches. It is found in both pediatric and adult populations, and it may lead to severe clinical presentations such as stroke and intracranial hemorrhage. Several surgical procedures have been developed to improve its clinical outcome. Imaging techniques have a key role in management of Moya-Moya disease, as they are necessary for diagnosis, choice of treatment and follow-up. Although catheter angiography remains the diagnostic gold standard, and nuclear-medicine techniques best perform hemodynamic studies, less invasive imaging techniques have become efficient in serving these purposes. Conventional MRI and MR angiography, as well as MR functional and metabolic studies, are now widely used in each stage of disease management, from diagnosis to follow-up. CT scan and Doppler sonography may also help assess severity of disease and effects of treatment. The aim of this review is to clarify the utility, efficiency and latest developments of each imaging modality in management of Moya-Moya disease.


Assuntos
Diagnóstico por Imagem/métodos , Doença de Moyamoya/diagnóstico , Adulto , Angiografia Cerebral/métodos , Ecoencefalografia/métodos , Humanos , Angiografia por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler , Dispositivos de Acesso Vascular
18.
Rev Neurol (Paris) ; 170(5): 381-9, 2014 May.
Artigo em Francês | MEDLINE | ID: mdl-24768439

RESUMO

Mitochondrial diseases are due to deficiency of the respiratory chain and are characterized by a broad clinical and genetic heterogeneity that makes diagnosis difficult. Some clinical presentations are highly suggestive of given gene mutations, allowing rapid genetic diagnosis. However, owing to the wide pattern of symptoms in mitochondrial disorders and the constantly growing number of disease genes, their genetic diagnosis is frequently difficult and genotype/phenotype correlations remain elusive. For this reason, brain MRI appears as a useful tool for genotype/phenotype correlations. Here, we report the most frequent neuroradiological signs in mitochondrial respiratory chain deficiency and we propose a diagnostic algorithm based on neuroimaging features, so as to direct molecular genetic tests in patients at risk of mitochondrial respiratory chain deficiency. This algorithm is based on the careful analysis of five areas on brain MRI: (1) basal ganglia (hyperintensities on T2 or calcifications); (2) cerebellum (hyperintensities on T2 or atrophy); (3) brainstem (hyperintensities on T2 or atrophy); (4) white matter (leukoencephalopathy); (5) cortex (sub-tentorial atrophy); (6) stroke-like episodes. We believe that the combination of brain MRI features is of value to support respiratory chain deficiency and direct molecular genetic tests.


Assuntos
Algoritmos , Transporte de Elétrons/genética , Imageamento por Ressonância Magnética , Doenças Mitocondriais/diagnóstico , Doenças Mitocondriais/genética , Neuroimagem/métodos , Encéfalo/patologia , Árvores de Decisões , Humanos , Doenças Mitocondriais/epidemiologia , Mutação
19.
J Med Genet ; 48(1): 16-23, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20972245

RESUMO

OBJECTIVE: To identify a consistent pattern of brain MRI imaging in primary complex I deficiency. Complex I deficiency, a major cause of respiratory chain dysfunction, accounts for various clinical presentations, including Leigh syndrome. Human complex I comprises seven core subunits encoded by mitochondrial DNA (mtDNA) and 38 core subunits encoded by nuclear DNA (nDNA). Moreover, its assembly requires six known and many unknown assembly factors. To date, no correlation between genotypes and brain MRI phenotypes has been found in complex I deficiencies. DESIGN AND SUBJECTS: The brain MRIs of 30 patients carrying known mutation(s) in genes involved in complex I were retrospectively collected and compared with the brain MRIs of 11 patients carrying known mutations in genes involved in the pyruvate dehydrogenase (PDH) complex as well as 10 patients with MT-TL1 mutations. RESULTS: All complex I deficient patients showed bilateral brainstem lesions (30/30) and 77% (23/30) showed anomalies of the putamen. Supratentorial stroke-like lesions were only observed in complex I deficient patients carrying mtDNA mutations (8/19) and necrotising leucoencephalopathy in patients with nDNA mutations (4/5). Conversely, the isolated stroke-like images observed in patients with MT-TL1 mutations, or the corpus callosum malformations observed in PDH deficient patients, were never observed in complex I deficient patients. CONCLUSION: A common pattern of brain MRI imaging was identified with abnormal signal intensities in brainstem and subtentorial nuclei with lactate peak as a clue of complex I deficiency. Combining clinico-biochemical data with brain imaging may therefore help orient genetic studies in complex I deficiency.


Assuntos
Encéfalo/enzimologia , Encéfalo/patologia , Complexo I de Transporte de Elétrons/deficiência , Imageamento por Ressonância Magnética/métodos , Doenças Mitocondriais/enzimologia , Doenças Mitocondriais/patologia , Adolescente , Adulto , Criança , Pré-Escolar , Complexo I de Transporte de Elétrons/genética , Feminino , Humanos , Lactente , Leucoencefalopatias/complicações , Leucoencefalopatias/patologia , Masculino , Pessoa de Meia-Idade , Doenças Mitocondriais/diagnóstico por imagem , Doenças Mitocondriais/genética , Mutação/genética , Complexo Piruvato Desidrogenase/genética , Radiografia , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/patologia , Adulto Jovem
20.
Pediatr Radiol ; 42(5): 599-605, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22237479

RESUMO

BACKGROUND: Percutaneous sclerotherapy is an effective treatment for aneurysmal bone cysts (ABCs). OBJECTIVE: The purpose of this study was to demonstrate the safety and efficacy of sclerotherapy with absolute alcohol and to propose a vascular classification of ABCs based on a retrospective review. MATERIALS AND METHODS: This was a review of children treated with absolute alcohol sclerotherapy for ABC at a single institution from January 1995 until November 2009. Treatment response was evaluated radiographically and clinically. Cyst fluid was classified as clear, partially bloody, or bloody. Presence of any venous drainage of the cyst was assessed by injection of contrast medium into the cyst cavity. RESULTS: Twenty-nine children with ages ranging from 2 to 16 years were included. Treatment response was good in 17 (59%), partial in 9 (31%), and poor in 3 (10%) children. Venous drainage was absent in six out of seven clear-fluid cysts, which we classified as lymphatic. Drainage was present in all seven bloody-fluid cysts, which we classified as venous. In seven partially bloody-fluid cysts, venous drainage was seen in three. CONCLUSION: Sclerotherapy with absolute alcohol is a safe and effective treatment of ABC. We propose classifying ABC as lymphatic or venous and suggest considering ABC intraosseous slow-flow vascular malformations.


Assuntos
Cistos Ósseos Aneurismáticos/classificação , Cistos Ósseos Aneurismáticos/terapia , Etanol/administração & dosagem , Soluções Esclerosantes/administração & dosagem , Escleroterapia/métodos , Adolescente , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Feminino , Fluoroscopia , Humanos , Lactente , Masculino , Radiografia Intervencionista , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA