RESUMO
INTODUCTION: Familial cerebral cavernous malformations (FCCM) are a rare condition characterized by the multiple presences of cavernous malformations located in the central nervous system. CASE DESCRIPTION: We present a case of FCCM incidental diagnosis in a 71-year-old male patient who underwent carotid artery stenting for high-grade carotid artery disease and subsequent reintervention for severe stent restenosis, determining neurological deficit. FCCM diagnosis was made due to the presence of hundreds of cavernous malformations located both in supra- and sub-tentorial regions highlighted by magnetic resonance and confirmed by genetic test for the mutation of the gene KRIT1, inherited also by his son.
Assuntos
Hemangioma Cavernoso do Sistema Nervoso Central , Proteínas Associadas aos Microtúbulos , Idoso , Artérias Carótidas , Hemangioma Cavernoso do Sistema Nervoso Central/diagnóstico por imagem , Hemangioma Cavernoso do Sistema Nervoso Central/genética , Hemangioma Cavernoso do Sistema Nervoso Central/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Proteínas Associadas aos Microtúbulos/genética , Linhagem , Proteínas Proto-Oncogênicas/genéticaRESUMO
An abdominal aortic aneurysm (AAA) is a dilatation of the abdominal aorta that progressively grows until it ruptures. Treatment is typically recommended when the diameter is more than 5 cm. The EVAR (Endovascular aneurysm repair) is a minimally invasive procedure that involves the placement of an expandable stent graft within the aorta to treat aortic disease without operating directly on the aorta. For years, stent grafts' essential design was based on metallic stent frames to support the fabric. More recently, a polymer-based technology has been proposed as an alternative method to seal AAA. This review underlines the two platforms that are based on a polymer technology: (1) the polymer-filled endobags, also known as Endovascular Aneurysm Sealing (EVAS) with Nellix stent graft; and (2) the O-ring EVAR polymer-based proximal neck sealing device, also known as an Ovation stent graft. Polymer characteristics for this particular aim, clinical applications, and durability results are hereby summarized and commented critically. The technique of inflating endobags filled with polymer to exclude the aneurysmal sac was not successful due to the lack of an adequate proximal fixation. The platform that used polymer to create a circumferential sealing of the aneurysmal neck has proven safe and effective.