RESUMO
Natriuretic peptides (NP) play an essential role in heart failure (HF) regulation, and their measurement has improved diagnostic and prognostic accuracy. Clinical symptoms and objective measurements, such as NP levels, should be included in the HF definition to render it more reliable and consistent among observers, hospitals, and healthcare systems. BNP and NT-proBNP are reasonable surrogates for cardiac disease, and their measurement is critical to early diagnosis and risk stratification of HF patients. NPs should be measured in all patients presenting with dyspnea or other symptoms suggestive of HF to facilitate early diagnosis and risk stratification. Both BNP and NT-proBNP are currently used for guided HF management and display comparable diagnostic and prognostic accuracy. Standardized cutoffs for each NP assay are essential for data comparison. The value of NP testing is recognized at various levels, including patient empowerment and education, analytical and operational issues, clinical HF management, and cost-effectiveness.
Assuntos
Insuficiência Cardíaca , Peptídeos Natriuréticos , Humanos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico , Peptídeos Natriuréticos/sangue , Peptídeos Natriuréticos/análise , Peptídeo Natriurético Encefálico/sangue , Biomarcadores/sangue , Fragmentos de Peptídeos/sangue , PrognósticoRESUMO
BACKGROUND: Secondary hypertension (SH) is a form of high blood pressure caused by an identifiable underlying condition. Although, it accounts for a small fraction of the overall hypertensive population, detection and management of SH is of utmost importance, because SH phenotypes carry a high cardiovascular risk and can possibly be cured by timely treatment. CONTENT: This review focuses on the endocrine causes of SH, such as primary aldosteronism, Cushing syndrome, thyroid disease, pheochromocytoma and paraganglioma, acromegaly, and rare monogenic forms. It discusses current biomarkers, analytical methods, and diagnostic strategies, highlighting advantages and limitations of each approach. It also explores the emerging -omics technologies that can provide a comprehensive and multidimensional assessment of SH and its underlying mechanisms. SUMMARY: Endocrine SH is a heterogeneous and complex condition that requires proper screening and confirmatory tests to avoid diagnostic delays and improve patient outcomes. Careful biomarker interpretation is essential due to potential interferences, variability, and method-dependent differences. Liquid chromatography-tandem mass spectrometry is a superior method for measuring low-concentration hormones and metabolites involved in SH, but it requires expertise. Omics approaches have great potential to identify novel biomarkers, pathways, and targets for SH diagnosis and treatment, especially considering its multifactorial nature.
Assuntos
Biomarcadores , Hipertensão , Humanos , Hipertensão/diagnóstico , Doenças do Sistema Endócrino/diagnóstico , Hiperaldosteronismo/diagnóstico , Feocromocitoma/diagnóstico , Síndrome de Cushing/diagnósticoRESUMO
Advances in technology have transformed healthcare and laboratory medicine. Biosensors have emerged as a promising technology in healthcare, providing a way to monitor human physiological parameters in a continuous, real-time, and non-intrusive manner and offering value and benefits in a wide range of applications. This position statement aims to present the current situation around biosensors, their perspectives and importantly the need to set the framework for their validation and safe use. The development of a qualification framework for biosensors should be conceptually adopted and extended to cover digitally measured biomarkers from biosensors for advancing healthcare and achieving more individualized patient management and better patient outcome.
Assuntos
Técnicas Biossensoriais , Técnicas Biossensoriais/métodos , Humanos , Telemedicina , BioengenhariaRESUMO
This opinion article highlights the critical role of laboratory medicine and emerging technologies in cardiovascular risk reduction through exposome analysis. The exposome encompasses all external and internal exposures an individual faces throughout their life, influencing the onset and progression of cardiovascular diseases (CVD). Integrating exposome data with genetic information allows for a comprehensive understanding of the multifactorial causes of CVD, facilitating targeted preventive interventions. Laboratory medicine, enhanced by advanced technologies such as metabolomics and artificial intelligence (AI), plays a pivotal role in identifying and mitigating these exposures. Metabolomics provides detailed insights into metabolic changes triggered by environmental factors, while AI efficiently processes complex datasets to uncover patterns and associations. This integration fosters a proactive approach in public health and personalized medicine, enabling earlier detection and intervention. The article calls for global implementation of exposome technologies to improve population health, emphasizing the need for robust technological platforms and policy-driven initiatives to seamlessly integrate environmental data with clinical diagnostics. By harnessing these innovative technologies, laboratory medicine can significantly contribute to reducing the global burden of cardiovascular diseases through precise and personalized risk mitigation strategies.
RESUMO
Thyroid dysfunctions are among the most common endocrine disorders and accurate biochemical testing is needed to confirm or rule out a diagnosis. Notably, true hyperthyroidism and hypothyroidism in the setting of a normal thyroid-stimulating hormone level are highly unlikely, making the assessment of free thyroxine (FT4) inappropriate in most new cases. However, FT4 measurement is integral in both the diagnosis and management of relevant central dysfunctions (central hypothyroidism and central hyperthyroidism) as well as for monitoring therapy in hyperthyroid patients treated with anti-thyroid drugs or radioiodine. In such settings, accurate FT4 quantification is required. Global standardization will improve the comparability of the results across laboratories and allow the development of common clinical decision limits in evidence-based guidelines. The International Federation of Clinical Chemistry and Laboratory Medicine Committee for Standardization of Thyroid Function Tests has undertaken FT4 immunoassay method comparison and recalibration studies and developed a reference measurement procedure that is currently being validated. However, technical and implementation challenges, including the establishment of different clinical decision limits for distinct patient groups, still remain. Accordingly, different assays and reference values cannot be interchanged. Two-way communication between the laboratory and clinical specialists is pivotal to properly select a reliable FT4 assay, establish reference intervals, investigate discordant results, and monitor the analytical and clinical performance of the method over time.
Assuntos
Hipertireoidismo , Hipotireoidismo , Humanos , Testes de Função Tireóidea , Tiroxina , Radioisótopos do Iodo , Hipotireoidismo/diagnóstico , Hipertireoidismo/diagnóstico , Padrões de Referência , Valores de ReferênciaRESUMO
OBJECTIVES: In the digital age, the metaverse has emerged with impressive potential for many segments of society. The metaverse could be presented as a parallel dimension able to enhance the physical world as well as our actions and decisions in it with the objective to use a coalition between the natural and virtual worlds for value creation. Our aim was to elaborate on the impact of the metaverse on laboratory medicine. METHODS: Based on the available evidence, literature and reports, we analyzed the different perspectives of the metaverse on laboratory medicine and the needs for an efficient transition. RESULTS: The convergence and integration of technologies in the metaverse will participate to the reimagination of laboratory medicine services with augmented services, users' experiences, efficiency, and personalized care. The revolution around the metaverse offers different opportunities for laboratory medicine but also open multiple related challenges that are presented in this article. CONCLUSIONS: Scientific societies, multidisciplinary teams and specialists in laboratory medicine must prepare the integration metaverse and meta-medical laboratories, raise the awareness, educate, set guidance to obtain a maximum of value and mitigate potential adverse consequences.
Assuntos
Unidades Hospitalares , Laboratórios , Humanos , Sociedades CientíficasRESUMO
The term "emerging technology" (ET) is used extensively, and there are numerous definitions offered, but to our knowledge, none specifically encompass the field of laboratory medicine. An ET definition that incorporates the overarching IFCC aim of "Advancing excellence in laboratory medicine to support healthcare worldwide" would clarify discussions. We discuss key aspects of the term "emerging technology(ies)" as it applies to laboratory medicine with a view to laying the foundations for a practical definition for the profession and propose the definition of an ET as "An analytical method or device that by virtue of its stage of development, translation into broad routine clinical practice, or geographical adoption and implementation has the potential to add value to clinical diagnostics".
Assuntos
Atenção à Saúde , LaboratóriosRESUMO
OBJECTIVES: Tumor markers are well-known for being important tools in the support of diagnosis, monitoring of treatment efficacy and follow-up of cancers. CA 125, CA 15-3 and HE 4 have demonstrated potential efficacy in other clinical indications. The main objective was to evaluate the biological variation of these glycoproteins using two different immunoassays in an apparently healthy Caucasian population. METHODS: Nineteen healthy volunteers including 11 women and 8 men were sampled weekly for 5 consecutive weeks. Samples were analyzed in duplicate on Lumipulse® G600II (Fujirebio) and on the Cobas e602 (Roche Diagnostics) analyzers. After assessment of normality, exclusion of outliers and analysis of homogeneity of variance, analytical variation (CVA), within-subject biological variation (CVI) and between-subject biological variation (CVG) were determined using a nested ANOVA. RESULTS: CVA, CVI and CVG were determined on both analyzers and both genders. For CA 125, the CVA ranges from 1.0 to 3.4%, the CVI from 5.7 to 13.8% and the CVG from 32.2 to 42.9%. For CA 15-3, the CVA is between 1.1 and 3.4%, the CVI between 3.9 and 6.5% and the CVG between 43.7 and 196.9%. Lastly, HE 4 has CVA values between 1.4 and 2.4%, CVI between 5.1 and 10.5% and CVG between 7.1 and 12.6%. CONCLUSIONS: Our study provided updated data on the biological variation of CA 125, HE 4 and CA 15-3. These data allow to improve the clinical interpretation and thus the management of the patient.
Assuntos
Lítio , População Branca , Humanos , Masculino , Feminino , Valores de Referência , Voluntários SaudáveisRESUMO
An emerging technology (ET) for laboratory medicine can be defined as an analytical method (including biomarkers) or device (software, applications, and algorithms) that by its stage of development, translation into broad routine clinical practice, or geographical adoption and implementation has the potential to add value to clinical diagnostics. Considering the laboratory medicine-specific definition, this document examines eight key tools, encompassing clinical, analytical, operational, and financial aspects, used throughout the life cycle of ET implementation. The tools provide a systematic approach starting with identifying the unmet need or identifying opportunities for improvement (Tool 1), forecasting (Tool 2), technology readiness assessment (Tool 3), health technology assessment (Tool 4), organizational impact map (Tool 5), change management (Tool 6), total pathway to method evaluation checklist (Tool 7), and green procurement (Tool 8). Whilst there are differences in clinical priorities between different settings, the use of this set of tools will help support the overall quality and sustainability of the emerging technology implementation.
Assuntos
Tecnologia Biomédica , Ciência de Laboratório Médico , Previsões , Ciência de Laboratório Médico/tendênciasRESUMO
Heart failure (HF) with preserved ejection fraction (HFpEF) is associated with high burden of comorbidities known to increase the mean platelet volume (MPV). This parameter has been associated with morbidity and mortality in HF. However, the role of platelets and the prognostic relevance of MPV in HFpEF remain largely unexplored. We aimed to evaluate the clinical usefulness of MPV as a prognostic marker in HFpEF. We prospectively enrolled 228 patients with HFpEF (79 ± 9 years; 66% females) and 38 controls of similar age and gender (78 ± 5 years; 63% females). All subjects underwent two-dimensional echocardiography and MPV measurements. Patients were followed-up for a primary end point of all-cause mortality or first HF hospitalization. The prognostic impact of MPV was determined using Cox proportional hazard models. Mean MPV was significantly higher in HFpEF patients compared with controls (MPV: 10.7 ± 1.1fL vs. 10.1 ± 1.1fL, p = .005). HFpEF patients (n = 56) with MPV >75th percentile (11.3 fL) displayed more commonly a history of ischemic cardiomyopathy. Over a median follow-up of 26 months, 136 HFpEF patients reached the composite endpoint. MPV >75th percentile was a significant predictor of the primary endpoint (HR: 1.70 [1.08; 2.67], p = .023) adjusted for NYHA class, chronic obstructive pulmonary disease, loop diuretics, renal function, and hemoglobin. We demonstrated that MPV was significantly higher in HFpEF patients compared with controls of similar age and gender. Elevated MPV was a strong and independent predictor of poor outcome in HFpEF patients and may be relevant for clinical use.
What is the context? Heart failure with preserved ejection fraction (HFpEF) is associated with several comorbidities known to increase the mean platelet volume (MPV).MPV is a measure of platelet size and a potential marker of platelet reactivity. An increased MPV results from an increased platelet turnover.MPV has been associated with morbidity and mortality from heart failure.No study has previously compared MPV between HFpEF and controls and investigated the prognostic relevance of MPV in HFpEF disease.What is new? In this study, we compared the MPV between HFpEF patients and controls of similar age and gender, prospectively enrolled between 2015 and 2021. We evaluated the prognostic role of elevated MPV in HFpEF patients.Our main results:The MPV was higher in HFpEF patients compared to controls of similar age and gender.HFpEF patients with elevated MPV displayed more commonly a history of ischemic cardiomyopathy.Elevated MPV was a strong and independent predictor of poor outcome in HFpEF patients.What is the impact? MPV may be relevant for clinical use to predict clinical outcome in HFpEF patients.Elevated MPV reflecting platelet activity supports the potential role of platelets in HFpEF's pathophysiology.
Assuntos
Insuficiência Cardíaca , Feminino , Humanos , Masculino , Insuficiência Cardíaca/diagnóstico , Prognóstico , Volume Sistólico , Volume Plaquetário Médio , Hospitalização , Função Ventricular EsquerdaRESUMO
Severe forms of coronavirus 2019 (COVID-19) disease are caused by an exaggerated systemic inflammatory response and subsequent inflammation-related coagulopathy. Anti-inflammatory treatment with low dose dexamethasone has been shown to reduce mortality in COVID-19 patients requiring oxygen therapy. However, the mechanisms of action of corticosteroids have not been extensively studied in critically ill patients in the context of COVID-19. Plasma biomarkers of inflammatory and immune responses, endothelial and platelet activation, neutrophil extracellular trap formation, and coagulopathy were compared between patients treated or not by systemic dexamethasone for severe forms of COVID-19. Dexamethasone treatment significantly reduced the inflammatory and lymphoid immune response in critical COVID-19 patients but had little effect on the myeloid immune response and no effect on endothelial activation, platelet activation, neutrophil extracellular trap formation, and coagulopathy. The benefits of low dose dexamethasone on outcome in critical COVID-19 can be partially explained by a modulation of the inflammatory response but not by reduction of coagulopathy. Future studies should explore the impact of combining dexamethasone with other immunomodulatory or anticoagulant drugs in severe COVID-19.
Assuntos
COVID-19 , Citocinas , Humanos , SARS-CoV-2 , Estado Terminal , Tratamento Farmacológico da COVID-19 , COVID-19/complicações , Dexametasona/farmacologia , Dexametasona/uso terapêuticoRESUMO
OBJECTIVES: Biological variation (BV) data obtained in a standardized way is valuable to assess the analytical requirements and the utility of a reference interval. Our study aimed to determine the short-term BV of thrombophilia (protein S, protein C, activated protein C resistance (APCR) and factor VIII) and hemophilia (factors VIII, IX and XI) parameters in plasma. Coagulation factors V and XII were also evaluated. Based on the obtained data, we assessed analytical performance specifications for the parameters. Finally, we intended to provide a robust tool for comparison of serial measurements of factors V, VIII, IX and XI. METHODS: A blood draw was performed weekly in 19 apparently healthy Caucasian adults for five weeks at Saint-Luc University Hospital (Brussels, Belgium). Parameters were measured in duplicate. BV components were calculated with a nested analysis of variance after exclusion of outliers. RESULTS: The analytical coefficient of variation (CV) varied from 1.5 to 4.6%, the within-subject CV from 1.6 to 8.9% and the between-subject CV from 3.8 to 24.1%. All parameters showed high individuality. For most parameters, the analytical goal was met with our assays. Reference change values (RCV) of -16.7% to +20.0%, -20.7% to +26.0%, -15.3% to +18.1% and -13.1% to +15.1% were obtained for factors V, VIII, IX and XI respectively. CONCLUSIONS: All studied parameters were highly individualized. The assessment of BV data can guide setting analytical goal specifications. Comparison of serial measurements in the follow-up of patients suffering from hepatic failure or mild hemophilia is facilitated by evaluation of the RCV.
Assuntos
Hemofilia A , Trombofilia , Adulto , Bélgica , Humanos , Valores de Referência , Trombofilia/diagnósticoRESUMO
BACKGROUND AND AIMS: To assess the hospitalized sick children admitted to the pediatric emergency department (ED) and to find new patterns of clinical and laboratory attributes using association rule mining (ARM). METHODS: In this observational study, 158 children with median (IQR) age 11 months and a PRISM III score of 5 (2-9) were enrolled. Hotspot data mining method was applied to assess clinical attributes, lab investigations and pre-defined outcome parameters of children and their association in sick hospitalized children aged 1 month to 12 years. RESULTS: We obtained 30 rules with value for outcome as discharge is given attributes as follows: duration of hospitalization > 4 days, lactate > 1.2 mmol/L, platelet = 3.67/µL, dur_ventil = 0 h, serum K = 5.2 mmol/L, SBP = 120 mmHg, pCO2 = 41.9 mmHg, PaO2 = 163 mmHg, age = 92 months, heart rate > 114-159 per minute, temperature > 98 °F, GCS (Glasgow Coma Scale) > 7-14, gas K = 4.14 mmol/L, gas Na = 138.1 mmol/L, BUN (Blood Urea Nitrogen) = 18.69 mg/dL, Diagnosis > 1-718, Creatinine = 1.2 mg/dL, serum Na = 148 mmol/L, shock = 2, Glucose = 144 mg/dL, Mg(i) > 0.23 meq/L, BUN > 6.54 mg/dL. CONCLUSION: ARM is an effective data analysis technique to find meaningful patterns using clinical features with actual numbers in pediatric critical illness. It can prove to be important while analysing the association of clinical attributes with disease pattern, its features, and therapeutic or intervention success patterns.
Assuntos
Glucose , Sódio , Humanos , Criança , Potássio , Nitrogênio da Ureia Sanguínea , Serviço Hospitalar de EmergênciaRESUMO
BACKGROUND: Sickle-cell anemia (SCA) is the most common genetic disease worldwide caused by a single mutation in the gene HBB. DNA testing can help to clarify the diagnosis when Hb electrophoresis is inconclusive. We evaluated the usefulness and feasibility of DNA-based diagnosis of SCA in rural Central Africa. METHODS: This is a cross-sectional study conducted from November 2016 to end October 2017 in the Hôpital Saint Luc de Kisantu, located 120 km from Kinshasa. This hospital offers the management of SCA patients, mainly identified using the Sickling test (Emmel test) combined with clinical features. We included patients aged 6 months to 18 years locally diagnosed as SCA, and we collected clinical and hematological data. All patients were offered Hb electrophoresis and DNA testing at the Center for Human Genetics of the University of Kinshasa. RESULTS: This study included 160 patients. Hemoglobin capillary electrophoresis suggested that 136 (85%) were homozygote SS, 13 (8.1%) were heterozygote (AS), and 11 (6.9%) were homozygote normal (AA). DNA testing confirmed these electrophoresis findings, with the exception of four patients, two AS in electrophoresis were found SS due to recent transfusion, and two SS in electrophoresis were found AS because they have compound heterozygous form S/ß°-thalassemia. The diagnosis of SCA was therefore wrongly ascertained with Emmel test in 15% of patients. CONCLUSION: This study reveals a high proportion of false-positive SCA diagnoses in a rural environment in Central Africa. This underlines the importance of DNA testing in conjunction with Hb electrophoresis.
Assuntos
Anemia Falciforme , Talassemia beta , Anemia Falciforme/diagnóstico , Anemia Falciforme/epidemiologia , Anemia Falciforme/genética , Estudos Transversais , DNA , República Democrática do Congo , Humanos , Prevalência , Talassemia beta/diagnósticoRESUMO
BACKGROUND: The CARdiac MARker Guideline Uptake in Europe (CAMARGUE) program is a multi-country audit of the use of cardiac biomarkers in routine clinical practice. METHODS: An email link to a web-based questionnaire of 30 multiple-choice questions was distributed via the professional societies in Europe. RESULTS: 374 questionnaires were returned from 39 countries, the majority of which were in northern Europe with a response rate of 8.2%-42.0%. The majority of the respondents were from hospitals with proportionately more responses from central hospitals than district hospitals. Cardiac troponin was the preferred cardiac biomarker, evenly split between cardiac troponin T (cTnT) and cardiac troponin I (cTnI). Aspartate transaminase and lactate dehydrogenase are no longer offered as cardiac biomarkers. Creatine kinase, creatine kinase MB isoenzyme, and myoglobin continue to be offered as part of the cardiac biomarker profile in approximately on 50% of respondents. There is widespread utilization of high sensitivity (hs) troponin assays. The majority of cTnT users measure hs-cTnT. 29.5% of laboratories measure cTnI by a non-hs method but there has been substantial conversion to hs-cTnI. The majority of respondents used ng/L and use the 99th percentile as the upper reference limit (71.9% of respondents). A range of diagnostic protocols are in use. CONCLUSIONS: There is widespread utilization of hs troponin methods. A significant minority do not use the 99th percentile as recommended and there is, as yet, little uptake of very rapid diagnostic strategies. Education of laboratory professionals and clinicians remains a priority.
Assuntos
Laboratórios , Troponina T , Biomarcadores , Creatina Quinase Forma MB , Humanos , Troponina IRESUMO
Since December 2019, we have been in the battlefield with a new threat to the humanity, known as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), which causes coronavirus disease 2019 (COVID-19), characterized by viral pneumonia. It may be asymptomatic or cause various symptoms, ranging from flu-like symptoms to acute respiratory distress syndrome and eventually death. At present, the only reliable test for COVID-19 diagnosis is quantitative reverse transcriptase-polymerase chain reaction. Assessing the immune response against SARS-CoV-2 could increase the detection sensitivity of infected population. Hereby, we report the performances of a fully automated chemiluminescent immunoassay (CLIA) on 276 serum samples. One hundred samples obtained from COVID-19 negative subjects (COVID-19 free) were analyzed to evaluate the diagnostic specificity of antibody (Ab) detection. Thereafter, 176 samples obtained from 125 patients with confirmed COVID-19 (COVID-19 patients) were selected to assess the diagnostic sensitivity of the CLIA. All samples were analyzed on MAGLUMI 800 platform. All COVID-19 free samples had Ab levels below the cutoff values. Hence, the diagnostic specificity was estimated at 100% (95% confidence interval [CI] = 96.3-100.0; positive predictive value = 100%). By the 18th day from the onset of symptoms, we reached an optimal diagnostic sensitivity (more than 95.0%) In fact, the diagnostic sensitivity increased over time and between 15 and 25 days after symptoms onset, reached 95.5% (95% CI = 84.9-99.2). The new automated CLIA analyzer appeared to be a robust and reliable method to measure specific Ab against COVID-19 at high throughput. Our data suggest that combining Ab and nucleic acid detection could increase diagnostic sensitivity.
Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Imunoglobulina M/sangue , Medições Luminescentes/métodos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade , Adulto JovemRESUMO
BACKGROUND: Interpretation of thyroid function tests by means of biological variation (BV) data is essential to identify significant changes between serial measurements at an individual level. Data on thyroid parameters in adults are limited. OBJECTIVES: We aimed at determining the BV of four thyroid function test (thyroid-stimulating hormone (TSH), free thyroxin (FT4), free triiodothyronine (FT3) and thyroglobulin (Tg)) by applying recent recommendations to acquire BV data on a latest generation of immunoassay. METHODS: Nineteen healthy volunteers (8 males and 11 females) were drawn every week during 5 consecutive weeks. Samples were analysed in duplicate on the Cobas 602 analyzer (Roche Diagnostics). After normality assessment, outlier exclusion and homogeneity of variance analysis, analytical variation (CVA ), within-subject biological variation (CVI ) and between-subject biological variation (CVG ) were determined using nested ANOVA. RESULTS: CVA , CVI and CVG were 0.9%, 19.7% and 37.6% for TSH; 3.6%, 4.6% and 10.8% for FT4; 2.2%, 6.0% and 8.6% for FT3; and 0.9%, 15.4% and 84.9% for Tg. Index of individuality (II) for all parameters was between 0.2 and 0.7. The percentage above which the change between two measures is truly significant (reference change value) was 54.7% for TSH, 16.2% for FT4, 17.7% for FT3 and 42.8% for Tg. CONCLUSION: Based on recent international recommendations, our study provides updated BV data for four thyroid function tests in European healthy volunteers. Reliable BV characteristics, and especially RCV, can facilitate the interpretation of consecutive thyroid function tests in an individual and therefore have the potential to efficiently support clinical decisions regarding thyroid diseases.
Assuntos
Objetivos , Glândula Tireoide , Adulto , Biomarcadores , Feminino , Voluntários Saudáveis , Humanos , Masculino , Valores de Referência , Tireotropina , Tiroxina , Tri-IodotironinaRESUMO
Cardiac troponins (cTn) are the preferred biomarkers for the evaluation of myocardial injury and play a key role in the diagnosis of acute myocardial infarction (MI). Pre-analytical or analytical issues and interferences affecting troponin T and I assays are therefore of major concern given the risk of misdiagnosis. False positive troponin results have been related to various interferences including anti-troponin antibodies, heterophilic antibodies, or elevated alkaline phosphatase level. On the other hand, false negative results have been reported in the case of a large biotin intake. These interferences are characterized with erroneous but reproducible troponin results. Of interest, non-reproducible results have also been reported in the literature. In other words, if the sample is reanalyzed a second time, a significant difference in troponin results will be observed. These interferences have been named "fliers" or "outliers". Compared to the biotin interference that received major attention in the literature, troponin outliers are also able to induce harmful clinical consequences for the patient. Moreover, the prevalence of outliers in recent studies was found to be higher (0.28-0.57%) compared to the biotin interference. The aim of this systematic review is to warn clinicians about these non-reproducible results that may alter their clinical judgment. Four case reports that occurred in the Clinique of Saint-Luc Bouge are presented to attest this point. Moreover, we aimed at identifying the nature of these non-reproducible troponin results, determining their occurrence, and describing the best way for their identification.
Assuntos
Infarto do Miocárdio , Troponina I , Biomarcadores , Biotina , Humanos , Infarto do Miocárdio/diagnóstico , Troponina TRESUMO
Background The correct identification of the macro-B12 interference (macroforms) is paramount to avoid potential erroneous clinical decisions. Our objectives were to determine whether immunoassays are affected by the presence of macro-B12 and to validate a polyethylene glycol (PEG) precipitation procedure to detect it. Methods Sixty-two serum samples obtained from healthy volunteers were analyzed to determine recovery and reference intervals (RIs) following PEG precipitation. Thereafter, 50 serum samples with very high levels of B12 (>1476 pmol/L) were randomly selected to search for macro-B12 interferences. Serum samples obtained from healthy volunteers and related PEG aliquots were analyzed on a Cobas® immunoassay. Patients' samples were analyzed on both Cobas® and Architect® immunoassays. Finally, samples suspected to contain macro-B12 were analyzed by size-exclusion chromatography (SEC) to confirm the presence of macro-B12. Results Recovery and post-PEG RIs determined on a Cobas 8000® in healthy volunteers ranged from 68.3% to 108.4% and from 122.1 to 514.4 pmol/L, respectively. Fifteen samples (30%) were found to show macro-B12 while using the recovery criteria, and nine samples (18%) while using the post-PEG RI. The other immunoassay ran on the Architect i2000® was also affected by the presence of macro-B12. Size-exclusion chromatography studies confirmed the presence of macro-B12 (immunoglobulin-B12 complexes). Conclusions The prevalence of macro-B12 in elevated B12 samples is high. We suggest to systematically screen for the presence of macro-B12 with PEG precipitation procedure in samples with elevated B12 levels to avoid potential misdiagnosis or harmful clinical consequences.
Assuntos
Análise Química do Sangue , Vitamina B 12/sangue , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
Background Biotin is currently a matter of concern for laboratories using biotin-streptavidin-based immunoassays. Biotin interferences have been reported for high-sensitive troponin T (hsTnT) and thyroid-stimulating hormone (TSH) assays. We aimed to evaluate the new generation of hsTnT and TSH electrochemiluminescent immunoassays announced to be less sensitive to biotin. Methods Firstly, we assessed the analytical performances of new generation assays (imprecision, bias, total error, limit of quantification) and compared previous and new generation assays in the absence of biotin. Secondly, we challenged both generations of assays with samples spiked with seven different biotin levels. The efficiency of new generation assays was also compared to the streptavidin beads treatment. Results New generation assays presented suitable analytical performances. Previous and new generations of hsTnT and TSH assays were commutable in the absence of biotin. In the presence of biotin, we confirmed that previous generation assays were affected by biotin concentration as low as 40.5 ng/mL and that new generation assays were not affected up to the announced tolerance threshold of 1200 ng/mL. After the streptavidin beads treatment, we observed a higher imprecision for both parameters and a constant 10% negative bias for TSH compared to new generation assays. Conclusions New generation of electrochemiluminescent immunoassays appears as a reliable systematic solution to prevent biotin interference for hsTnT and TSH testing.