Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Niger J Clin Pract ; 21(12): 1656-1661, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30560832

RESUMO

AIM: Temporary cement can be applied for both permanent and temporary cementation of implant-supported fixed restorations. These cements must have certain physical and mechanical properties. Specifically, the film thickness directly affects the cement's clinical success. The aim of this study was to evaluate and compare the film thicknesses of six temporary cements before and after thermal cycling. MATERIALS AND METHODS: Eighty-four metal copings with uniform holding loops were fabricated and divided into 12 groups of seven samples each. Six of these groups were subjected to a thermal cycling process. The copings were cemented to solid implant abutments (Implance Solid Abutment, 3.5-mm cervical diameter, 2 mm high, 6° taper, Implance Dental Implant System; AGS Medical, Trabzon, Turkey), using six different types of cement. The fitting surfaces were coated with the luting cements. After steeping in artificial saliva for 24 hours, the specimens were subjected to pull-out testing using an Instron machine. Specimens in the thermal cycling groups were subjected to 700 thermal cycles (36-55°C) prior to pull-out testing. RESULTS: The Mann-Whitney U test revealed significant differences between the retention values of the thermal cycling (+) and thermal cycling (-) groups (U = 153.0, P < 0.01). The retention values of the groups subjected to thermal cycling were significantly lower than those of the cements that were not subjected to thermal cycling. Thermal cycling also affected the film thickness significantly (Wilcoxon signed rank test, Z = -5.533, P < 0.001). CONCLUSIONS: Thermal cycling affects the film thickness and retention of temporary cements significantly. The retention value was significantly higher for glass ionomer cement than for the other cements tested, and this cement also exhibited greatest film thickness.


Assuntos
Cimentação/métodos , Dente Suporte , Cimentos Dentários/química , Prótese Dentária Fixada por Implante , Coroas , Retenção em Prótese Dentária , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro/química , Humanos , Teste de Materiais , Cimentos de Resina/química , Turquia
2.
Niger J Clin Pract ; 20(2): 252-255, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28091447

RESUMO

This case report presents the prosthodontic rehabilitation of a patient with a resected right mandible, caused by an accident. Right condyle, ramus, and the posterior part of ramus were affected by the accident. These structures were resected, and the mandible was positioned toward the surgical area and a facial asymmetry was occurred. The patient was treated with a bar-retained maxillar denture with a guide ramp and an implant-supported fixed mandibular prosthesis.


Assuntos
Mandíbula/cirurgia , Implante de Prótese Mandibular/reabilitação , Articulação Temporomandibular/cirurgia , Prótese Dentária Fixada por Implante , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA