Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Subst Use Misuse ; 58(5): 735-738, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36866964

RESUMO

Background: Deaths from drug overdose have reached a crisis level, with more than 100,000 reported from April 2020 to April 2021. Novel approaches to address it are urgently needed. Objectives: National Institute on Drug Abuse (NIDA) is leading novel comprehensive efforts to develop safe and effective products that address the needs of the citizens affected by SUD. NIDA aims to support research and development of medical devices intended to monitor, diagnose, or treat substance use disorders. Results: NIDA participates in Blueprint MedTech program is part of the large NIH Blueprint for Neurological Research Initiative. It supports the research and development of new medical devices through product optimization, pre-clinical testing, and human subject studies, including clinical trials. The program is structured in two main components - Blueprint MedTech Incubator and Blueprint MedTech Translator. It offers free to the researcher services that are typically unavailable in academic environment - business expertise facilities and staffing to successfully develop minimum viable devices, pre-clinical bench testing, clinical studies, planning and executing in manufacturing, as well as regulatory expertise. Conclusions: Through Blueprint MedTech, NIDA provides innovators with expanded resources to ensure the success of the research.


Assuntos
Overdose de Drogas , Transtornos Relacionados ao Uso de Substâncias , Estados Unidos , Humanos , National Institute on Drug Abuse (U.S.) , Transtornos Relacionados ao Uso de Substâncias/terapia , Transtornos Relacionados ao Uso de Substâncias/diagnóstico , Pesquisa
2.
Neuromodulation ; 23(1): 3-9, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31965667

RESUMO

The United States Food and Drug Administration (FDA) ensures that patients in the United States have access to safe and effective medical devices. The division of neurological and physical medicine devices reviews medical technologies that interface with the nervous system, including many neuromodulation devices. This article focuses on neuromodulation devices and addresses how to navigate the FDA's regulatory landscape to successfully bring devices to patients.


Assuntos
Aprovação de Equipamentos/legislação & jurisprudência , Aprovação de Equipamentos/normas , Neuroestimuladores Implantáveis/normas , Estimulação Elétrica Nervosa Transcutânea/normas , Humanos , Estimulação Elétrica Nervosa Transcutânea/instrumentação , Estados Unidos
4.
Neuron ; 92(5): 943-948, 2016 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-27930909

RESUMO

The United States Food and Drug Administration (FDA) ensures that patients in the U.S. have access to safe and effective medical devices. The Division of Neurological and Physical Medicine Devices reviews medical technologies that interface with the nervous system. This article addresses how to navigate the FDA's regulatory landscape to successfully bring medical devices to patients.


Assuntos
Aprovação de Equipamentos/legislação & jurisprudência , Equipamentos e Provisões , Acessibilidade aos Serviços de Saúde , United States Food and Drug Administration/legislação & jurisprudência , Disfonia , Humanos , Medicina Física e Reabilitação , Estados Unidos
5.
Biomaterials ; 44: 55-70, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25617126

RESUMO

Neural electrodes are an important part of brain-machine interface devices that can restore functionality to patients with sensory and movement disorders. Chronically implanted neural electrodes induce an unfavorable tissue response which includes inflammation, scar formation, and neuronal cell death, eventually causing loss of electrode function. We developed a poly(ethylene glycol) hydrogel coating for neural electrodes with non-fouling characteristics, incorporated an anti-inflammatory agent, and engineered a stimulus-responsive degradable portion for on-demand release of the anti-inflammatory agent in response to inflammatory stimuli. This coating reduces in vitro glial cell adhesion, cell spreading, and cytokine release compared to uncoated controls. We also analyzed the in vivo tissue response using immunohistochemistry and microarray qRT-PCR. Although no differences were observed among coated and uncoated electrodes for inflammatory cell markers, lower IgG penetration into the tissue around PEG+IL-1Ra coated electrodes indicates an improvement in blood-brain barrier integrity. Gene expression analysis showed higher expression of IL-6 and MMP-2 around PEG+IL-1Ra samples, as well as an increase in CNTF expression, an important marker for neuronal survival. Importantly, increased neuronal survival around coated electrodes compared to uncoated controls was observed. Collectively, these results indicate promising findings for an engineered coating to increase neuronal survival and improve tissue response around implanted neural electrodes.


Assuntos
Materiais Revestidos Biocompatíveis/farmacologia , Eletrodos Implantados , Proteína Antagonista do Receptor de Interleucina 1/metabolismo , Maleimidas/farmacologia , Neurônios/efeitos dos fármacos , Peptídeo Hidrolases/metabolismo , Polietilenoglicóis/farmacologia , Sequência de Aminoácidos , Animais , Astrócitos/efeitos dos fármacos , Astrócitos/patologia , Barreira Hematoencefálica/efeitos dos fármacos , Barreira Hematoencefálica/patologia , Adesão Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Sulfatos de Condroitina/metabolismo , Regulação da Expressão Gênica/efeitos dos fármacos , Proteína Glial Fibrilar Ácida/metabolismo , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Imunoglobulina G/metabolismo , Mediadores da Inflamação/metabolismo , Lipopolissacarídeos/farmacologia , Masculino , Microglia/efeitos dos fármacos , Dados de Sequência Molecular , Polietilenoglicóis/química , Ratos Sprague-Dawley , Propriedades de Superfície
6.
J Biomed Mater Res A ; 102(5): 1486-99, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-23666919

RESUMO

The performance of neural electrodes implanted in the brain is often limited by host response in the surrounding brain tissue, including astrocytic scar formation, neuronal cell death, and inflammation around the implant. We applied conformal microgel coatings to silicon neural electrodes and examined host responses to microgel-coated and uncoated electrodes following implantation in the rat brain. In vitro analyses demonstrated significantly reduced astrocyte and microglia adhesion to microgel-coated electrodes compared to uncoated controls. Microgel-coated and uncoated electrodes were implanted in the rat brain cortex and the extent of activated microglia and astrocytes as well as neuron density around the implant were evaluated at 1, 4, and 24 weeks postimplantation. Microgel coatings reduced astrocytic recruitment around the implant at later time points. However, microglial response indicated persistence of inflammation in the area around the electrode. Neuronal density around the implanted electrodes was also lower for both implant groups compared to the uninjured control. These results demonstrate that microgel coatings do not significantly improve host responses to implanted neural electrodes and underscore the need for further improvements in implantable materials.


Assuntos
Encéfalo/fisiologia , Materiais Revestidos Biocompatíveis/farmacologia , Eletrodos Implantados , Géis/farmacologia , Neurônios/fisiologia , Animais , Antígenos CD/metabolismo , Antígenos de Diferenciação Mielomonocítica/metabolismo , Encéfalo/efeitos dos fármacos , Antígeno CD11b/metabolismo , Adesão Celular/efeitos dos fármacos , Proteína Glial Fibrilar Ácida/metabolismo , Imuno-Histoquímica , Neuroglia/citologia , Neurônios/efeitos dos fármacos , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA