Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
J Ultrasound Med ; 43(1): 127-136, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37842972

RESUMO

OBJECTIVES: Topically applied macromolecules have the potential to provide vision-saving treatments for many of the leading causes of blindness in the United States. The aim of this study was to determine if ultrasound can be applied to increase transcorneal drug delivery of macromolecules without dangerously overheating surrounding ocular tissues. METHODS: Dissected corneas of adult rabbits were placed in a diffusion cell between a donor compartment filled with a solution of macromolecules (40, 70 kDa, or 150 kDa) and a receiver compartment. Each cornea was exposed to the drug solution for 60 minutes, with the experimental group receiving 5 minutes of continuous ultrasound or 10 minutes of pulsed ultrasound at a 50% duty cycle (pulse repetition frequency of 500 ms on, 500 ms off) at the beginning of treatment. Unfocused circular ultrasound transducers were operated at 0.5 to 1 W/cm2 intensity and at 600 kHz frequency. RESULTS: The greatest increase in transcorneal drug delivery seen was 1.2 times (P < .05) with the application of pulsed ultrasound at 0.5 W/cm2 and 600 kHz for 10 minutes with 40 kDa macromolecules. Histological analysis revealed structural damage mostly in the corneal epithelium, with most damage occurring at the epithelial surface. CONCLUSIONS: This study suggests that ultrasound may be used for enhancing transcorneal delivery of macromolecules of lower molecular weights. Further research is needed on the long-term effects of ultrasound parameters used in this study on human ocular tissues.


Assuntos
Córnea , Terapia por Ultrassom , Animais , Humanos , Coelhos , Córnea/diagnóstico por imagem , Córnea/metabolismo , Ultrassonografia , Ondas Ultrassônicas , Permeabilidade
2.
Int J Hyperthermia ; 39(1): 998-1009, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35876089

RESUMO

OBJECTIVE: Thermosensitive liposomes (TSL) and other triggered drug delivery systems (DDS) are promising therapeutic strategies for targeted drug delivery. However, successful designs with candidate drugs depend on many variables, including nanoparticle formulation, drug properties, and cancer cell properties. We developed a computational model based on experimental data to predict the potential efficacies of drugs when used with triggered DDS, such as TSL. METHODS: A computer model based on the Krogh cylinder was developed to predict uptake and cell survival with four anthracyclines when delivered by intravascular triggered DDS (e.g., TSL): doxorubicin (DOX), idarubicin (IDA), pirarubicin (PIR), and aclarubicin (ACLA). We simulated three tumor types derived from SVR angiosarcoma, LLC lung cancer, or SCC-1 oral carcinoma cells. In vitro cellular drug uptake and cytotoxicity data were obtained experimentally and incorporated into the model. RESULTS: For all three cell lines, ACLA and IDA had the fastest cell uptake, with slower uptake for DOX and PIR. Cytotoxicity was highest for IDA and lowest for ACLA. The computer model predicted the highest tumor drug uptake for ACLA and IDA, resulting from their rapid cell uptake. Overall, IDA was most effective and produced the lowest tumor survival fraction, with DOX being the second best. Perivascular drug penetration was reduced for drugs with rapid cell uptake, potentially limiting delivery to cancer cells distant from the vasculature. CONCLUSION: Combining simple in vitro experiments with a computer model could provide a powerful screening tool to evaluate the potential efficacy of candidate investigative drugs preceding TSL encapsulation and in vivo studies.


Assuntos
Lipossomos , Nanopartículas , Antibióticos Antineoplásicos , Linhagem Celular Tumoral , Doxorrubicina/farmacologia , Doxorrubicina/uso terapêutico , Sistemas de Liberação de Medicamentos , Nanopartículas/uso terapêutico
3.
Int J Hyperthermia ; 38(1): 1149-1163, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34376106

RESUMO

PURPOSE: To develop and validate a three-dimensional (3-D) computer model based on accurate geometry of an irrigated cardiac radiofrequency (RF) ablation catheter with microwave radiometry capability, and to test catheter performance. METHODS: A computer model was developed based on CAD geometry of a RF cardiac ablation catheter prototype to simulate electromagnetic heating, heat transfer, and computational fluid dynamics (blood flow, open irrigation, and natural convection). Parametric studies were performed; blood flow velocity (0-25 cm/s) and irrigation flow (0-40 ml/min) varied, both with perpendicular (PE) and parallel (PA) catheter orientations relative to tissue. Tissue Agar phantom studies were performed under similar conditions, and temperature maps were recorded via infrared camera. Computer model simulations were performed with constant voltage and with voltage adjusted to achieve maximum tissue temperatures of 95-105 °C. RESULTS: Model predicted thermal lesion width at 5 W power was 5.8-6.4 mm (PE)/6.5-6.6 mm (PA), and lesion depth was 4.0-4.3 mm (PE)/4.0-4.1 mm (PA). Compared to phantom studies, the mean errors of the computer model were as follows: 6.2 °C(PE)/4.3 °C (PA) for maximum gel temperature, 0.7 mm (10.9%) (PE)/0.1 mm (0.8%) (PA) for lesion width, and 0.3 mm (7.7%)(PE)/0.7 mm (19.1%) (PA) for lesion depth. For temperature-controlled ablation, model predicted thermal lesion width was 7-9.2 mm (PE)/8.6-9.2 mm (PA), and lesion depth was 4.3-5.5 mm (PE)/3.4-5.4 mm (PA). CONCLUSIONS: Computer models were able to reproduce device performance and to enable device evaluation under varying conditions. Temperature controlled ablation of irrigated catheters enables optimal tissue temperatures independent of patient-specific conditions such as blood flow.


Assuntos
Ablação por Cateter , Catéteres , Simulação por Computador , Coração , Humanos , Temperatura
4.
Int J Hyperthermia ; 36(1): 817-826, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31451077

RESUMO

Objective: Thermosensitive liposomal doxorubicin (TSL-Dox) is a promising stimuli-responsive nanoparticle drug delivery system that rapidly releases the contained drug in response to hyperthermia (HT) (>40 °C). Combined with localized heating, TSL-Dox allows highly localized delivery. The goals of this study were to demonstrate that real-time fluorescence imaging can visualize drug uptake during delivery, and can predict tumor drug uptake. Methods: Nude mice carrying subcutaneous tumors (Lewis lung carcinoma) were anesthetized and injected with TSL-Dox (5 mg/kg dose). Localized HT was induced by heating tumors for 15, 30 or 60 min via a custom-designed HT probe placed superficially at the tumor location. In vivo fluorescence imaging (excitation 523 nm, emission 610 nm) was performed before, during, and for 5 min following HT. After imaging, tumors were extracted, drug uptake was quantified by high-performance liquid chromatography, and correlated with in vivo fluorescence. Plasma samples were obtained before and after HT to measure TSL-Dox pharmacokinetics. Results: Local drug uptake could be visualized in real-time during HT. Compared to unheated control tumors, fluorescence of heated tumors increased by 4.6-fold (15 min HT), 9.3-fold (30 min HT), and 13.2-fold (60 min HT). HT duration predicted tumor drug uptake (p = .02), with tumor drug concentrations of 4.2 ± 1.3 µg/g (no HT), 7.1 ± 5.9 µg/g (15 min HT), 14.1 ± 6.7 µg/g (30 min HT) and 21.4 ± 12.6 µg/g (60 min HT). There was good correlation (R2 = 0.67) between fluorescence of the tumor region and tumor drug uptake. Conclusions: Real-time in vivo fluorescence imaging can visualize drug uptake during delivery, and can predict tumor drug uptake.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Pulmonar de Lewis/diagnóstico por imagem , Carcinoma Pulmonar de Lewis/terapia , Doxorrubicina/análogos & derivados , Hipertermia Induzida , Imagem Óptica , Animais , Antibióticos Antineoplásicos/sangue , Antibióticos Antineoplásicos/farmacocinética , Carcinoma Pulmonar de Lewis/metabolismo , Doxorrubicina/administração & dosagem , Doxorrubicina/sangue , Doxorrubicina/farmacocinética , Sistemas de Liberação de Medicamentos , Feminino , Camundongos Endogâmicos BALB C , Camundongos Nus , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/farmacocinética , Temperatura
5.
Int J Hyperthermia ; 34(6): 786-794, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29284329

RESUMO

PURPOSE: Current release assays have inadequate temporal resolution ( ∼ 10 s) to characterise temperature sensitive liposomes (TSL) designed for intravascular triggered drug release, where release within the first few seconds is relevant for drug delivery. MATERIALS AND METHODS: We developed a novel release assay based on a millifluidic device. A 500 µm capillary tube was heated by a temperature-controlled Peltier element. A TSL solution encapsulating a fluorescent compound was pumped through the tube, producing a fluorescence gradient along the tube due to TSL release. Release kinetics were measured by analysing fluorescence images of the tube. We measured three TSL formulations: traditional TSL (DPPC:DSPC:DSPE-PEF2000,80:15:5), MSPC-LTSL (DPPC:MSPC:DSPE-PEG2000,85:10:5) and MPPC-LTSL (DPPC:MMPC:PEF2000,86:10:4). TSL were loaded with either carboxyfluorescein (CF), Calcein, tetramethylrhodamine (TMR) or doxorubicin (Dox). TSL were diluted in one of the four buffers: phosphate buffered saline (PBS), 10% bovine serum albumin (BSA) solution, foetal bovine serum (FBS) or human plasma. Release was measured between 37-45 °C. RESULTS: The millifluidic device allowed measurement of release kinetics within the first few seconds at ∼5 ms temporal resolution. Dox had the fastest release and highest release %, followed by CF, Calcein and TMR. Of the four buffers, release was fastest in human plasma, followed by FBS, BSA and PBS. CONCLUSIONS: The millifluidic device allows measurement of TSL release at unprecedented temporal resolution, thus allowing adequate characterisation of TSL release at time scales relevant for intravascular triggered drug release. The type of buffer and encapsulated compound significantly affect release kinetics and need to be considered when designing and evaluating novel TSL-drug combinations.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Liberação Controlada de Fármacos/efeitos dos fármacos , Hipertermia Induzida/métodos , Lipossomos/química , Microfluídica/métodos , Humanos , Temperatura
6.
Int J Hyperthermia ; 33(1): 74-82, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27431040

RESUMO

INTRODUCTION: For computational models of microwave ablation (MWA), knowledge of the antenna design is necessary, but the proprietary design of clinical applicators is often unknown. We characterised the specific absorption rate (SAR) during MWA experimentally and compared to a multi-physics simulation. METHODS: An infrared (IR) camera was used to measure SAR during MWA within a split ex vivo liver model. Perseon Medical's short-tip (ST) or long-tip (LT) MWA antenna were placed on top of a tissue sample (n = 6), and microwave power (15 W) was applied for 6 min, while intermittently interrupting power. Tissue surface temperature was recorded via IR camera (3.3 fps, 320 × 240 resolution). SAR was calculated intermittently based on temperature slope before and after power interruption. Temperature and SAR data were compared to simulation results. RESULTS: Experimentally measured SAR changed considerably once tissue temperatures exceeded 100 °C, contrary to simulation results. The ablation zone diameters were 1.28 cm and 1.30 ± 0.03 cm (transverse), and 2.10 cm and 2.66 ± -0.22 cm (axial), for simulation and experiment, respectively. The average difference in temperature between the simulation and experiment were 5.6 °C (ST) and 6.2 °C (LT). Dice coefficients for 1000 W/kg SAR iso-contour were 0.74 ± 0.01 (ST) and 0.77 (± 0.03) (LT), suggesting good agreement of SAR contours. CONCLUSION: We experimentally demonstrated changes in SAR during MWA ablation, which were not present in simulation, suggesting inaccuracies in dielectric properties. The measured SAR may be used in simplified computer simulations to predict tissue temperature when the antenna geometry is unknown.


Assuntos
Técnicas de Ablação , Micro-Ondas , Modelos Biológicos , Animais , Simulação por Computador , Fígado/cirurgia , Suínos , Temperatura
7.
Int J Hyperthermia ; 33(7): 733-740, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28540814

RESUMO

PURPOSE: To evaluate lyso-thermosensitive liposomal doxorubicin (LTLD, ThermoDox®) in combination with loco-regional mild hyperthermia (HT) for targeted drug delivery to the bladder wall and potential treatment of bladder cancer. MATERIAL AND METHODS: Porcine in vivo studies were performed with the following groups: (i) intravenous (IV) LTLD with hyperthermia (LTLD + HT); (ii) IV doxorubicin (DOX) with hyperthermia (IV DOX + HT) and (iii) IV LTLD without hyperthermia (LTLD - HT). Drug formulations were delivered via 30 min IV infusion coinciding with 1-h bladder irrigation (45 °C water for HT groups, 37 °C for non-HT group), followed by immediate bladder resection. DOX concentrations were measured in consecutive sections parallel to the bladder lumen by liquid chromatography following drug extraction. Computer models were developed to simulate tissue heating and drug release from LTLD. RESULTS: Comparing mean DOX concentrations at increasing depths from the lumen to outer surface of the bladder wall, the ranges for LTLD + HT, IV DOX + HT and LTLD - HT, respectively, were 20.32-3.52 µg/g, 2.34-0.61 µg/g and 2.18-0.51 µg/g. The average DOX concentrations in the urothelium/lamina and muscularis, respectively, were 9.7 ± 0.67 and 4.09 ± 0.81 µg/g for IV LTLD + HT, 1.2 ± 0.39 and 0.86 ± 0.24 µg/g for IV DOX + HT, and 1.15 ± 0.38 and 0.62 ± 0.15 µg/g for LTLD - HT. Computational model results were similar to measured DOX levels and suggest adequate temperatures were reached within the bladder wall for drug release from LTLD. CONCLUSIONS: Doxorubicin accumulation and distribution within the bladder wall was achieved at concentrations higher than with free IV doxorubicin by mild bladder hyperthermia combined with systemic delivery of LTLD.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/análogos & derivados , Sistemas de Liberação de Medicamentos , Hipertermia Induzida , Animais , Antibióticos Antineoplásicos/farmacocinética , Terapia Combinada , Doxorrubicina/administração & dosagem , Doxorrubicina/farmacocinética , Feminino , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/farmacocinética , Suínos , Bexiga Urinária/metabolismo , Neoplasias da Bexiga Urinária/terapia
8.
Crit Rev Biomed Eng ; 42(6): 467-92, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25955712

RESUMO

The application of supraphysiological temperatures (>40°C) to biological tissues causes changes at the molecular, cellular, and structural level, with corresponding changes in tissue function and in thermal, mechanical and dielectric tissue properties. This is particularly relevant for image-guided thermal treatments (e.g. hyperthermia and thermal ablation) delivering heat via focused ultrasound (FUS), radiofrequency (RF), microwave (MW), or laser energy; temperature induced changes in tissue properties are of relevance in relation to predicting tissue temperature profile, monitoring during treatment, and evaluation of treatment results. This paper presents a literature survey of temperature dependence of electrical (electrical conductivity, resistivity, permittivity) and thermal tissue properties (thermal conductivity, specific heat, diffusivity). Data of soft tissues (liver, prostate, muscle, kidney, uterus, collagen, myocardium and spleen) for temperatures between 5 to 90°C, and dielectric properties in the frequency range between 460 kHz and 3 GHz are reported. Furthermore, perfusion changes in tumors including carcinomas, sarcomas, rhabdomyosarcoma, adenocarcinoma and ependymoblastoma in response to hyperthmic temperatures up to 46°C are presented. Where appropriate, mathematical models to describe temperature dependence of properties are presented. The presented data is valuable for mathematical models that predict tissue temperature during thermal therapies (e.g. hyperthermia or thermal ablation), as well as for applications related to prediction and monitoring of temperature induced tissue changes.


Assuntos
Ablação por Cateter , Hipertermia Induzida , Modelos Biológicos , Animais , Condutividade Elétrica , Radiação Eletromagnética , Fígado/irrigação sanguínea , Fígado/efeitos da radiação , Masculino , Micro-Ondas , Próstata/irrigação sanguínea , Próstata/efeitos da radiação , Fluxo Sanguíneo Regional/fisiologia , Fluxo Sanguíneo Regional/efeitos da radiação , Temperatura , Condutividade Térmica
9.
Int J Hyperthermia ; 30(1): 1-5, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24350642

RESUMO

Like other technically sophisticated medical endeavours, a hyperthermia clinic relies on skilled staffing. Physicians, physicists and technologists perform multiple tasks to ensure properly functioning equipment, appropriate patient selection, and to plan and administer this treatment. This paper reviews the competencies and tasks that are used in a hyperthermia clinic.


Assuntos
Instituições de Assistência Ambulatorial , Hipertermia Induzida , Humanos , Hipertermia Induzida/instrumentação , Corpo Clínico , Monitorização Fisiológica , Médicos , Termometria/instrumentação , Recursos Humanos
11.
Int J Hyperthermia ; 29(4): 318-23, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23738699

RESUMO

PURPOSE: Image-guided ablative therapies use temperatures greater than 45 °C to kill abnormal cells. There is limited published data of cell survival after ablative temperature exposures, which is of importance to predict ablation zone dimensions. The objective of this study was to determine and mathematically model survival of hepatocellular carcinoma cells following ablative temperature exposures (45-60 °C). MATERIALS AND METHODS: Hepatocellular carcinoma (HCC) cell lines were plated in 96-well plates, and heated between 45 and 60 °C for 0-32 min. Heating was applied by a rapid media exchange with heated Hank's balanced salt solution (HBSS) in a temperature-controlled water bath. Cell viability was determined by MTS assay. Survival data was modelled by the Arrhenius model, and the thermal isoeffective dose (TID) model where kinetic parameters were determined via non-linear optimisation. RESULTS: Results suggest that the thermal dose based on cumulative equivalent minutes and parameters as used for hyperthermia exposures (<43 °C) is not applicable for ablative exposures. We found R = 0.72 for temperatures between 45-60°C for the TID model. The Arrhenius parameters were frequency factor A = 3.25E43 1/s, and activation energy Ea = 281 kJ/mol. These parameters correlate well with a prior study in the same cell line, and with threshold temperatures for necrosis from in vivo studies. CONCLUSIONS: Our results suggest that standard TID model kinetic parameters based on hyperthermia studies, often also used at ablation temperatures, are not applicable at these higher temperatures for HCC cells.


Assuntos
Carcinoma Hepatocelular/terapia , Hipertermia Induzida , Neoplasias Hepáticas/terapia , Modelos Biológicos , Sobrevivência Celular , Células Hep G2 , Temperatura Alta , Humanos
12.
Cancers (Basel) ; 15(2)2023 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-36672347

RESUMO

Thermosensitive liposomes (TSL) are triggered nanoparticles that release the encapsulated drug in response to hyperthermia. Combined with localized hyperthermia, TSL enabled loco-regional drug delivery to tumors with reduced systemic toxicities. More recent TSL formulations are based on intravascular triggered release, where drug release occurs within the microvasculature. Thus, this delivery strategy does not require enhanced permeability and retention (EPR). Compared to traditional nanoparticle drug delivery systems based on EPR with passive or active tumor targeting (typically <5%ID/g tumor), TSL can achieve superior tumor drug uptake (>10%ID/g tumor). Numerous TSL formulations have been combined with various drugs and hyperthermia devices in preclinical and clinical studies over the last four decades. Here, we review how the properties of TSL dictate delivery and discuss the advantages of rapid drug release from TSL. We show the benefits of selecting a drug with rapid extraction by tissue, and with quick cellular uptake. Furthermore, the optimal characteristics of hyperthermia devices are reviewed, and impact of tumor biology and cancer cell characteristics are discussed. Thus, this review provides guidelines on how to improve drug delivery with TSL by optimizing the combination of TSL, drug, and hyperthermia method. Many of the concepts discussed are applicable to a variety of other triggered drug delivery systems.

14.
Int J Hyperthermia ; 28(4): 337-48, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22621735

RESUMO

PURPOSE: To develop and validate a computational model that simulates (1) tissue heating with high intensity focused ultrasound (HIFU), and (2) resulting hyperthermia-mediated drug delivery from temperature-sensitive liposomes (TSL). MATERIALS AND METHODS: HIFU heating in tissue was simulated using a heat transfer model based on the bioheat equation, including heat-induced cessation of perfusion. A spatio-temporal multi-compartment pharmacokinetic model simulated intravascular release of doxorubicin from TSL, its transport into interstitium, and cell uptake. Two heating schedules were simulated, each lasting 30 min: (1) hyperthermia at 43 °C (HT) and (2) hyperthermia followed by a high temperature (50 °C for 20 s) pulse (HT+). As preliminary model validation, in vivo studies were performed in thigh muscle of a New Zealand White rabbit, where local hyperthermia with a clinical magnetic resonance-guided HIFU system was applied following TSL administration. RESULTS: HT produced a defined region of high doxorubicin concentration (cellular concentration ∼15-23 µg/g) in the target region. Cellular drug uptake was directly related to HT duration, with increasing doxorubicin uptake up to ∼2 h. HT+ enhanced drug delivery by ∼40% compared to HT alone. Temperature difference between model and experiment within the hyperthermia zone was on average 0.54 °C. Doxorubicin concentration profile agreed qualitatively with in vivo fluorescence profile. CONCLUSIONS: Computational models can predict temperature and delivered drug from combination of HIFU with TSL. Drug delivery using TSL may be enhanced by prolonged hyperthermia up to 2 h or by local cessation of vascular perfusion with a high temperature pulse following hyperthermia.


Assuntos
Simulação por Computador , Sistemas de Liberação de Medicamentos/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade , Hipertermia Induzida/métodos , Animais , Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/administração & dosagem , Lipossomos , Neoplasias/metabolismo , Neoplasias/terapia , Coelhos , Temperatura
15.
Int J Hyperthermia ; 28(8): 766-75, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23043501

RESUMO

PURPOSE: The purpose of this study was to monitor tumour blood flow with power Doppler ultrasound following antiangiogenic therapy with bevacizumab in order to optimally time the application of radiofrequency (RF) ablation to increase ablation diameter. MATERIALS AND METHODS: Athymic nude mice bearing human hepatocellular carcinoma xenografts were treated with bevacizumab and imaged daily with power Doppler ultrasound to quantify tumour blood flow. Mice were treated with RF ablation alone or in combination with bevacizumab at the optimal time, as determined by ultrasound. Ablation diameter was measured with histology and tumour microvascular density was calculated with immunohistochemistry. A computational thermal model of RF ablation was used to estimate ablation volume. RESULTS: A maximum reduction of 27.8 ± 8.6% in tumour blood flow occurred on day 2 following antiangiogenic therapy, while control tumours increased 29.3 ± 17.1% (p < 0.05). Tumour microvascular density was similarly reduced by 45.1 ± 5.9% on day 2 following antiangiogenic therapy. Histology demonstrated a 13.6 ± 5.6% increase in ablation diameter (40 ± 21% increase in volume) consistent with a computational model. CONCLUSION: Quantitative power Doppler ultrasound is a useful biomarker to monitor tumour blood flow following antiangiogenic treatment and to guide the application of RF ablation as a drug plus device combination therapy.


Assuntos
Inibidores da Angiogênese/administração & dosagem , Anticorpos Monoclonais Humanizados/administração & dosagem , Carcinoma Hepatocelular/terapia , Ablação por Cateter , Neoplasias Hepáticas/terapia , Animais , Bevacizumab , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Terapia Combinada , Modelos Animais de Doenças , Células Hep G2 , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Camundongos , Camundongos Nus , Fluxo Sanguíneo Regional , Ultrassonografia Doppler , Ensaios Antitumorais Modelo de Xenoenxerto
16.
Int J Hyperthermia ; 28(4): 320-36, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22621734

RESUMO

PURPOSE: Mild hyperthermia (40-45 °C) is a proven adjuvant for radiotherapy and chemotherapy. Magnetic resonance guided high intensity focused ultrasound (MR-HIFU) can non-invasively heat solid tumours under image guidance. Low temperature-sensitive liposomes (LTSLs) release their drug cargo in response to heat (>40 °C) and may improve drug delivery to solid tumours when combined with mild hyperthermia. The objective of this study was to develop and implement a clinically relevant MR-HIFU mild hyperthermia heating algorithm for combination with LTSLs. MATERIALS AND METHODS: Sonications were performed with a clinical MR-HIFU platform in a phantom and rabbits bearing VX2 tumours (target = 4-16 mm). A binary control algorithm was used for real-time mild hyperthermia feedback control (target = 40-41 °C). Drug delivery with LTSLs was measured with HPLC. Data were compared to simulation results and analysed for spatial targeting accuracy (offset), temperature accuracy (mean), homogeneity of heating (standard deviation (SD), T10 and T90), and thermal dose (CEM43). RESULTS: Sonications in a phantom resulted in better temperature control than in vivo. Sonications in VX2 tumours resulted in mean temperatures between 40.4 °C and 41.3 °C with a SD of 1.0-1.5 °C (T10 = 41.7-43.7 °C, T90 = 39.0-39.6 °C), in agreement with simulations. 3D spatial offset was 0.1-3.2 mm in vitro and 0.6-4.8 mm in vivo. Combination of MR-HIFU hyperthermia and LTSLs demonstrated heterogeneous delivery to a partially heated VX2 tumour, as expected. CONCLUSIONS: An MR-HIFU mild hyperthermia heating algorithm was developed, resulting in accurate and homogeneous heating within the targeted region in vitro and in vivo, which is suitable for applications in drug delivery.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Hipertermia Induzida/métodos , Animais , Antibióticos Antineoplásicos/administração & dosagem , Doxorrubicina/administração & dosagem , Espectroscopia de Ressonância Magnética , Transplante de Neoplasias , Neoplasias/metabolismo , Neoplasias/terapia , Coelhos
17.
Cancers (Basel) ; 14(5)2022 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-35267630

RESUMO

Thermosensitive liposomal doxorubicin (TSL-Dox) combined with localized hyperthermia enables targeted drug delivery. Tumor drug uptake occurs only during hyperthermia. We developed a novel method for removal of systemic TSL-Dox remaining after hyperthermia-triggered delivery to reduce toxicities. The carotid artery and jugular vein of Norway brown rats carrying two subcutaneous BN-175 tumors were catheterized. After allowing the animals to recover, TSL-Dox was infused at 7 mg/kg dose. Drug delivery to one of the tumors was performed by inducing 15 min microwave hyperthermia (43 °C). At the end of hyperthermia, an extracorporeal circuit (ECC) comprising a heating module to release drug from TSL-Dox followed by an activated carbon filter to remove free drug was established for 1 h (n = 3). A computational model simulated TSL-Dox pharmacokinetics, including ECC filtration, and predicted cardiac Dox uptake. In animals receiving ECC, we were able to remove 576 ± 65 mg of Dox (29.7 ± 3.7% of the infused dose) within 1 h, with a 2.9-fold reduction of plasma AUC. Fluorescent monitoring enabled real-time quantification of blood concentration and removed drug. Computational modeling predicted that up to 59% of drug could be removed with an ideal filter, and that cardiac uptake can be reduced up to 7×. We demonstrated removal of drug remaining after tumor delivery, reduced plasma AUC, and reduced cardiac uptake, suggesting reduced toxicity.

18.
Theranostics ; 11(15): 7276-7293, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34158850

RESUMO

Effective drug delivery in brain tumors remains a major challenge in oncology. Although local hyperthermia and stimuli-responsive delivery systems, such as thermosensitive liposomes, represent promising strategies to locally enhance drug delivery in solid tumors and improve outcomes, their application in intracranial malignancies remains unexplored. We hypothesized that the combined abilities of closed-loop trans-skull Magnetic Resonance Imaging guided Focused Ultrasound (MRgFUS) hyperthermia with those of thermosensitive drugs can alleviate challenges in drug delivery and improve survival in gliomas. Methods: To conduct our investigations, we first designed a closed loop MR-guided Focused Ultrasound (MRgFUS) system for localized trans-skull hyperthermia (ΔT < 0.5 °C) in rodents and established safety thresholds in healthy mice. To assess the abilities of the developed system and proposed therapeutic strategy for FUS-triggered chemotherapy release we employed thermosensitive liposomal Dox (TSL-Dox) and tested it in two different glioma tumor models (F98 in rats and GL261 in mice). To quantify Dox delivery and changes in the transvascular transport dynamics in the tumor microenvironment we combined fluorescent microscopy, dynamic contrast enhanced MRI (DCE-MRI), and physiologically based pharmacokinetic (PBPK) modeling. Lastly, to assess the therapeutic efficacy of the system and of the proposed therapeutic strategy we performed a survival study in the GL261 glioma bearing mice. Results: The developed closed-loop trans-skull MRgFUS-hyperthermia system that operated at 1.7 MHz, a frequency that maximized the brain (FUS-focus) to skull temperature ratio in mice, was able to attain and maintain the desired focal temperature within a narrow range. Histological evidence (H&E and Nissl) suggests that focal temperature at 41.5 ± 0.5 °C for 10 min is below the threshold for tissue damage. Quantitative analysis of doxorubicin delivery from TSLs with MRgFUS-hyperthermia demonstrated 3.5-fold improvement in cellular uptake in GL261 glioma mouse tumors (p < 0.001) and 5-fold increase in delivery in F98 glioma rat tumors (p < 0.05), as compared to controls (TSL-Dox-only). Moreover, PBPK modeling of drug transport that was calibrated using the experimental data indicated that thermal stress could lead to significant improvement in the transvascular transport (2.3-fold increase in the vessel diffusion coefficient; P < 0.001), in addition to promoting targeted Dox release. Prospective experimental investigations with DCE-MRI during FUS-hyperthermia, supported these findings and provided evidence that moderate thermal stress (≈41 °C for up to 10 min) can promote acute changes in the vascular transport dynamics in the brain tumor microenvironment (Ktrans value for control vs. FUS was 0.0097 and 0.0148 min-1, respectively; p = 0.026). Crucially, survival analysis demonstrated significant improvement in the survival in the TSL-Dox-FUS group as compared to TSL-Dox-only group (p < 0.05), providing supporting evidence on the therapeutic potential of the proposed strategy. Conclusions: Our investigations demonstrated that spatially controlled thermal stress can be attained and sustained in the mouse brain, using a trans-skull closed-loop MRgFUS system, and used to promote the effective delivery of chemotherapy in gliomas from thermosensitive drugs. This system also allowed us to conduct mechanistic investigations that resulted in the refinement of our understanding on the role of thermal stress in augmenting mass and drug transport in brain tumors. Overall, our study established a new paradigm for effective drug delivery in brain tumors based on closed-loop ultrasound-mediated thermal stress and thermosensitive drugs.


Assuntos
Neoplasias Encefálicas/terapia , Doxorrubicina , Sistemas de Liberação de Medicamentos , Glioma/terapia , Hipertermia Induzida , Crânio , Terapia por Ultrassom , Animais , Linhagem Celular Tumoral , Doxorrubicina/farmacocinética , Doxorrubicina/farmacologia , Feminino , Camundongos
19.
IEEE Open J Eng Med Biol ; 2: 187-197, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34734189

RESUMO

GOAL: The impact of hyperthermia (HT) method on tumor drug uptake with thermosensitive liposomes (TSL) is not well understood. METHODS: We created realistic three-dimensional (3-D) computer models that simulate TSL-encapsulated doxorubicin (TSL-DOX) delivery in mouse tumors with three HT methods (thermistor probe (T), laser (L) and water bath (WB), at 15 min and 60 min HT duration), with corroborating in vivo studies. RESULTS: Average computer model-predicted tumor drug concentrations (µg/g) were 8.8(T, 15 min), 21.0(T, 60 min), 14.1(L, 15 min), 25.2(L, 60 min), 9.4(WB, 15 min), and 8.7(WB, 60 min). Tumor fluorescence was increased by 2.6 × (T) and 1.6 × (L) when HT duration was extended from 15 to 60 min (p < 0.05), with no increase for WB HT. Pharmacokinetic analysis confirmed that water bath HT causes rapid depletion of encapsulated TSL-DOX in systemic circulation due to the large heated tissue volume. CONCLUSIONS: Untargeted large volume HT causes poor tumor drug uptake from TSL.

20.
Commun Biol ; 4(1): 920, 2021 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-34321602

RESUMO

Intravascular triggered drug delivery systems (IV-DDS) for local drug delivery include various stimuli-responsive nanoparticles that release the associated agent in response to internal (e.g., pH, enzymes) or external stimuli (e.g., temperature, light, ultrasound, electromagnetic fields, X-rays). We developed a computational model to simulate IV-DDS drug delivery, for which we quantified all model parameters in vivo in rodent tumors. The model was validated via quantitative intravital microscopy studies with unencapsulated fluorescent dye, and with two formulations of temperature-sensitive liposomes (slow, and fast release) encapsulating a fluorescent dye as example IV-DDS. Tumor intra- and extravascular dye concentration dynamics were extracted from the intravital microscopy data by quantitative image processing, and were compared to computer model results. Via this computer model we explain IV-DDS delivery kinetics and identify parameters of IV-DDS, of drug, and of target tissue for optimal delivery. Two parameter ratios were identified that exclusively dictate how much drug can be delivered with IV-DDS, indicating the importance of IV-DDS with fast drug release (~sec) and choice of a drug with rapid tissue uptake (i.e., high first-pass extraction fraction). The computational model thus enables engineering of improved future IV-DDS based on tissue parameters that can be quantified by imaging.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Desenvolvimento de Medicamentos/métodos , Neoplasias/tratamento farmacológico , Corantes Fluorescentes/química , Cinética , Lipossomos/química , Nanopartículas/metabolismo , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA