Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Perfusion ; 27(2): 141-5, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22143092

RESUMO

Lower extremity ischemia is common when the femoral artery is used for veno-arterial extracorporeal membrane oxygenation (VA ECMO). We describe a new technique to reperfuse the extremity. The ipsilateral posterior tibial artery is exposed via a small incision behind the medial malleolus. The vessel is cannulated in a retrograde fashion and connected to the arterial limb of the ECMO circuit. Thirty-six patients received a posterior tibial reperfusion cannula: average flow was 155.8 ml/min and increased over the initial 24 hours. Fifty-eight percent received the posterior tibial cannula within 6 hours of ECMO initiation and none sustained permanent lower extremity injury. Of the remaining 42%, three required amputation or developed permanent neurologic injury. Overall survival was 41%. Cannulation of the posterior tibial artery is a simple technique to reperfuse the lower extremity during VA ECMO. The cannula should be inserted within 6 hours of ECMO initiation to avoid irreversible ischemic damage.


Assuntos
Oxigenação por Membrana Extracorpórea/métodos , Artéria Femoral/cirurgia , Isquemia/prevenção & controle , Perna (Membro)/irrigação sanguínea , Tíbia/irrigação sanguínea , Artérias da Tíbia/cirurgia , Adolescente , Adulto , Cateterismo/métodos , Criança , Estudos de Coortes , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Isquemia/etiologia , Perna (Membro)/cirurgia , Pessoa de Meia-Idade , Tíbia/cirurgia , Adulto Jovem
2.
J Thorac Cardiovasc Surg ; 122(6): 1094-100, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11726884

RESUMO

OBJECTIVE: Artificial lungs may have a role in supporting patients with end-stage lung disease as a bridge or alternative to lung transplantation. This investigation was performed to determine the effect of an artificial lung, perfused by the right ventricle in parallel with the pulmonary circulation, on indices of right ventricular load in a model of pulmonary hypertension. METHODS: Seven adult male sheep were connected to a low-resistance membrane oxygenator through conduits anastomosed end to side to the pulmonary artery and left atrium. Banding of the distal pulmonary artery generated acute pulmonary hypertension. Data were obtained with and without flow through the device conduits. Outcome measures of right ventricular load included hemodynamic parameters, as well as analysis of impedance, power consumption, wave reflections, cardiac efficiency, and the tension-time index. RESULTS: The model of pulmonary hypertension increased all indices of right ventricular load and decreased ventricular efficiency. Allowing flow through the artificial lung significantly reduced mean pulmonary artery pressure, zero harmonic impedance, right ventricular power consumption, amplitude of reflected waves, and the tension-time index. Cardiac efficiency was significantly increased. CONCLUSIONS: An artificial lung perfused by the right ventricle and applied in parallel with the pulmonary circulation reduces ventricular load and improves cardiac efficiency in the setting of pulmonary hypertension. These data suggest that an artificial lung in this configuration may benefit patients with end-stage lung disease and pulmonary hypertension with right ventricular strain.


Assuntos
Órgãos Artificiais , Hipertensão Pulmonar/fisiopatologia , Pulmão , Função Ventricular Direita , Resistência das Vias Respiratórias/fisiologia , Animais , Hipertensão Pulmonar/terapia , Masculino , Circulação Pulmonar/fisiologia , Ovinos , Função Ventricular Direita/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA