Cardiology ; 148(4): 335-346, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37279710

RESUMO

INTRODUCTION: Balloon-expandable (BE) and self-expandable (SE) prostheses are the main types of devices currently used in transcatheter aortic valve implantation (TAVI). Despite the different designs, clinical practice guidelines do not make any specific recommendation on the selection of one device over the other. Most operators are trained in using both BE and SE prostheses, but operator experience with each of the two designs might influence patient outcomes. The aim of this study was to compare the immediate and mid-term clinical outcomes during the learning curve in BE versus SE TAVI. METHODS: The transfemoral TAVI procedures performed in a single center between July 2017 and March 2021 were grouped according to the type of implanted prosthesis. The procedures in each group were ordered according to the case sequence number. For each patient, a minimum follow-up time of 12 months was required for inclusion in the analysis. The outcomes of the BE TAVI procedures were compared with the outcomes of the SE TAVI procedures. Clinical endpoints were defined according to the Valve Academic Research Consortium 3 (VARC-3). RESULTS: The median follow-up time was 28 months. Each device group included 128 patients. In the BE group, case sequence number predicted mid-term all-cause mortality at an optimal cutoff value ≤58 procedures (AUC 0.730; 95% CI: 0.644-0.805; p < 0.001), while in the SE group, the cutoff value was ≤85 procedures (AUC 0.625; 95% CI: 0.535-0.710; p = 0.04). A direct comparison of the AUC showed that case sequence number was equally adequate in predicting mid-term mortality, irrespective of prosthesis type (p = 0.11). A low case sequence number was associated with an increased rate of VARC-3 major cardiac and vascular complications (OR 0.98 95% CI: 0.96-0.99; p = 0.03) in the BE device group, and with an increased rate of post-TAVI aortic regurgitation ≥ grade II (OR 0.98; 95% CI: 0.97-0.99; p = 0.03) in the SE device group. CONCLUSIONS: In transfemoral TAVI, case sequence number influenced mid-term mortality irrespective of prosthesis type, but the learning curve was longer in the case of SE devices.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Curva de Aprendizado , Resultado do Tratamento , Valva Aórtica/cirurgia , Desenho de Prótese
2.
J Pers Med ; 13(6)2023 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-37373978

RESUMO

BACKGROUND: Inflammation plays a significant role in the pathogenesis of aortic stenosis. This study aimed to investigate the prognostic value of the monocyte-HDL cholesterol ratio (MHR), a new inflammatory marker, in severe aortic stenosis (AS) patients who underwent transcatheter aortic valve replacement (TAVR). METHODS: A total of 125 patients with severe AS who underwent TAVR were assessed. Clinical, echocardiographic and laboratory data relevant to the research were retrospectively obtained from the patients' records. The MHR was determined by dividing the absolute monocyte count by the HDL-C value. The primary endpoints were overall and cardiovascular mortality. RESULTS: During a median follow-up time of 39 months, primary endpoints were developed in 51 (40.8%) patients (overall mortality) and 21 (16.8%) patients (cardiovascular mortality). A receiver operating characteristic (ROC) analysis showed that by using a cut-off level of 16.16, the MHR predicted the all-cause mortality with a sensitivity of 50.9% and specificity of 89.1%. In predicting cardiovascular mortality, the MHR exhibited a sensitivity of 80.9% and specificity of 70.1% when a cut-off level of 13.56 was used. In the multivariate analysis, the MHR (p < 0.0001; 95% CI: 1.06-1.15) and atrial fibrillation (p = 0.018; 95% CI: 1.11-3.38) were found to be significant predictors of overall mortality. CONCLUSIONS: This study showed a significant elevation in the MHR among patients who experienced all-cause and cardiovascular mortality and this ratio emerged as an independent predictor of all-cause death in patients with severe AS undergoing TAVR.