Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 43(8): 1597-1607, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38833104

RESUMO

PURPOSE: To comprehensively investigate the diagnostic performance of routinely used assays in MPXV testing, the National Center of Clinical Laboratories in China conducted a nationwide external quality assessment (EQA) scheme and an evaluated nine assays used by ≥ 5 laboratories in the EQA. METHODS: MPXV virus-like particles with 2700, 900 and 300 copies/mL were distributed to 195 EQA laboratories. For extended analysis, triple-diluted samples from 9000 to 4.12 copies/mL were repeated 20 times using the assays employed by ≥ 5 laboratories. The diagnostic performance was assessed by analyzing EQA data and calculating the limits of detection (LODs). RESULTS: The performance was competent in 87.69% (171/195) of the participants and 87.94% (175/199) of the datasets. The positive percentage agreements (PPAs) were greater than 99% for samples at 2700 and 900 copies/mL, and 95.60% (761/796) for samples at 300 copies/mL. The calculated LODs for the two clades ranged from 228.44 to 924.31 copies/mL and were greater than the LODs specified by the respective kits. EasyDiagnosis had the lowest calculated LODs and showed superior performance in EQA, whereas BioGerm and Sansure, with higher calculated LODs, did not perform well in EQA. CONCLUSION: This study provides valuable information from the EQA data and evaluation of the diagnostic performance of MPXV detection assays. It also provided insights into reagent optimization and enabled prompt public health interventions for the outbreak.


Assuntos
Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , China/epidemiologia , Limite de Detecção , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Monkeypox virus/genética , Monkeypox virus/isolamento & purificação
2.
Clin Chem ; 69(9): 1038-1049, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37303219

RESUMO

BACKGROUND: Laboratory-developed metagenomic next-generation sequencing (mNGS) assays are increasingly being used for the diagnosis of infectious disease. To ensure comparable results and advance the quality control for the mNGS assay, we initiated a large-scale multicenter quality assessment to scrutinize the ability of mNGS to detect pathogens in lower respiratory infections. METHODS: A reference panel containing artificial microbial communities and real clinical samples was used to assess the performance of 122 laboratories. We comprehensively evaluated the reliability, the source of false-positive and false-negative microbes, as well as the ability to interpret the results. RESULTS: A wide variety of weighted F1-scores was observed across 122 participants, with a range from 0.20 to 0.97. The majority of false positive microbes (68.56%, 399/582) were introduced from "wet lab." The loss of microbial sequence during wet labs was the chief cause (76.18%, 275/361) of false-negative errors. When the human context is 2 × 105 copies/mL, most DNA and RNA viruses at titers above 104 copies/mL could be detected by >80% of the participants, while >90% of the laboratories could detect bacteria and fungi at titers lower than 103 copies/mL. A total of 10.66% (13/122) to 38.52% (47/122) of the participants could detect the target pathogens but failed to reach a correct etiological diagnosis. CONCLUSIONS: This study clarified the sources of false-positive and false-negative results and evaluated the performance of interpreting the results. This study was valuable for clinical mNGS laboratories to improve method development, avoid erroneous results being reported, and implement regulatory quality controls in the clinic.


Assuntos
Microbiota , Infecções Respiratórias , Humanos , Reprodutibilidade dos Testes , Infecções Respiratórias/diagnóstico , Sequenciamento de Nucleotídeos em Larga Escala , Bioensaio , Metagenômica , Sensibilidade e Especificidade
3.
Clin Chem Lab Med ; 61(12): 2237-2247, 2023 11 27.
Artigo em Inglês | MEDLINE | ID: mdl-37377068

RESUMO

OBJECTIVES: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen detection is an indispensable tool for epidemic surveillance in the post-pandemic era. Faced with irregular performance, a comprehensive external quality assessment (EQA) scheme was conducted by the National Center for Clinical Laboratories (NCCL) to evaluate the analytical performance and status of SARS-CoV-2 antigen tests. METHODS: The EQA panel included ten lyophilized samples containing serial 5-fold dilutions of inactivated SARS-CoV-2-positive supernatants of the Omicron BA.1 and BA.5 strains and negative samples, which were classified into "validating" samples and "educational" samples. Data were analyzed according to qualitative results for each sample. RESULTS: A total of 339 laboratories in China participated in this EQA scheme, and 378 effective results were collected. All validating samples were correctly reported by 90.56 % (307/339) of the participants and 90.21 % (341/378) of the datasets. The positive percent agreement (PPA) was >99 % for samples with concentrations of 2 × 107 copies/mL but was 92.20 % (697/756) for 4 × 106 copies/mL and 25.26 % (382/1,512) for 8 × 105 copies/mL samples. Colloidal gold was the most frequently used (84.66 %, 320/378) but showed the lowest PPAs (57.11 %, 1,462/2,560) for positive samples compared with fluorescence immunochromatography (90 %, 36/40) and latex chromatography (79.01 %, 335/424). Among 11 assays used in more than 10 clinical laboratories, ACON showed a higher sensitivity than other assays. CONCLUSIONS: The EQA study can help to validate whether it's necessary to update antigen detection assays for manufacturers and provide participants with information about the performance of assays to take the first step toward routine post-market surveillance.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Laboratórios , Pandemias , Teste para COVID-19 , Sensibilidade e Especificidade
4.
J Clin Microbiol ; 60(4): e0237421, 2022 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-35341301

RESUMO

Emerging severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants with enhanced transmissibility, pathogenicity, and immune escape ability have ravaged many countries and regions, which has brought substantial challenges to pandemic prevention and control. Real-time reverse transcriptase PCR (rRT-PCR) is widely used for SARS-CoV-2 detection but may be limited by the continuous evolution of the virus. However, the sensitivity of Chinese commercial rRT-PCR kits to critical SARS-CoV-2 variants remains unknown. In this study, contrived MS2 virus-like particles were used as reference materials to evaluate the analytical sensitivity of Daan, BioGerm, EasyDiagnosis, Liferiver, and Sansure kits when detecting six important variants (Alpha, Beta, Gamma, Delta, Omicron, and Fin-796H). The Beta and Delta variants adversely affected the analytical sensitivity of the BioGerm ORF1ab gene assay (9.52% versus 42.96%, P = 0.014, and 14.29% versus 42.96%, P = 0.040, respectively), whereas the N gene assay completely failed in terms of the Fin-796H variant. The Gamma and Fin-796H variants impeded the PCR amplification efficiency for the Sansure ORF1ab gene assay (33.33% versus 66.67%, P = 0.031, and 66.67% versus 95.24%, P = 0.040, respectively), and the Delta variant compromised the E gene assay (52.38% versus 85.71%, P = 0.019). The Alpha and Omicron variants had no significant effect on the kits. This study highlights the necessity of identifying the potential effect of viral mutations on the efficacy and sensitivity of clinical detection assays. It can also provide helpful insights regarding the development and optimization of diagnostic assays and aid the strategic management of the ongoing pandemic.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Pandemias , Reação em Cadeia da Polimerase Via Transcriptase Reversa , SARS-CoV-2/genética
5.
J Clin Lab Anal ; 36(1): e24139, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34811797

RESUMO

BACKGROUND: Quality control materials are necessary for assay development, test validation, and proficiency testing in cancer mutation analysis. Most of the existing controls for somatic mutations only harbor a single variant and are derived from unstable cell lines. This study aimed to establish a method to create stable multianalyte controls in a defined background by genome editing in GM12878 cells, which also can be applied for the reference of next-generation sequencing. METHODS: GM12878 cells were electroporated with a donor plasmid containing a mutant DNA sequence and a Cas9/sgRNA expressing vector. The genome-edited GM12878 cell was validated with Sanger sequencing, amplification refractory mutation system (ARMS), and next-generation sequencing (NGS). RESULTS: We have successfully generated a mutant GM12878 cell line harboring the defined variants including single-nucleotide variants (SNVs), small insertions and deletions (indels), and structural variants (SVs). The introduction of intended mutations in GM12878 cell line was confirmed by both ARMS and sequencing methods. CONCLUSIONS: We developed a method for the preparation of the multiplexed controls for reference mutations in cancer gene by genome editing in GM12878 cells. This methodology can be used to generate other stable cancer reference materials with an unlimited supply.


Assuntos
Análise Mutacional de DNA , Edição de Genes/métodos , Neoplasias/genética , Sistemas CRISPR-Cas/genética , Linhagem Celular Tumoral , Análise Mutacional de DNA/métodos , Análise Mutacional de DNA/normas , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Sequenciamento de Nucleotídeos em Larga Escala/normas , Humanos , Mutação/genética , Controle de Qualidade , Padrões de Referência
6.
J Clin Lab Anal ; 35(5): e23746, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33826163

RESUMO

BACKGROUND: Mismatch repair deficiency (dMMR) status induced by MLH1 protein deficiency plays a pivotal role in therapeutic decision-making for cancer patients. Appropriate quality control (QC) materials are necessary for monitoring the accuracy of MLH1 protein deficiency assays used in clinical laboratories. METHODS: CRISPR/Cas9 technology was used to edit the MLH1 gene of GM12878Cas9 cells to establish MLH1 protein-deficient cell lines. The positive cell lines were screened and validated by Sanger sequencing, Western blot (WB), and next-generation sequencing (NGS) and were then used to prepare formalin-fixed, paraffin-embedded (FFPE) samples through xenografting. These FFPE samples were tested by hematoxylin and eosin (H&E) staining and immunohistochemistry (IHC) for suitability as novel QC materials for MLH1 protein deficiency testing. RESULTS: We successfully cultured 358 monoclonal cells, with a survival rate of 37.3% (358/960) of the sorted monoclonal cells. Through Sanger sequencing, cell lines with MLH1 gene mutation were identified. Subsequently, two cell lines with MLH1 protein deficiency were identified by WB and named as GM12878Cas9_6 and GM12878Cas9_10. The NGS results further confirmed that the MLH1 gene mutation in these two cell lines would cause the formation of stop codons and terminate the expression of the MLH1 protein. The H&E staining and IHC results also verified the deficiency of the MLH1 protein, and FFPE samples from xenografts proved their similarity and consistency with clinical samples. CONCLUSIONS: We successfully established MLH1 protein-deficient cell lines. Followed by xenografting, we developed novel FFPE QC materials with homogenous, sustainable, and typical histological structures advantages that are suitable for the standardization of clinical IHC methods.


Assuntos
Sistemas CRISPR-Cas/genética , Edição de Genes/normas , Proteína 1 Homóloga a MutL/deficiência , Proteína 1 Homóloga a MutL/genética , Ensaios Antitumorais Modelo de Xenoenxerto , Animais , Sequência de Bases , Linhagem Celular , Humanos , Camundongos Endogâmicos NOD , Camundongos SCID , Mutação/genética , Controle de Qualidade
7.
J Med Virol ; 91(1): 115-123, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30091789

RESUMO

Hepatitis C virus (HCV) RNA can be detected in body fluids such as urine. However, because of deficiencies in established isolation and detection methods, the actual prevalence and form of HCV RNA in the urine of patients with hepatitis C remain unclear. To more sensitively and accurately measure urine HCV RNA levels, a novel real-time PCR assay with a modified isolation method and short amplicon designed for short HCV RNA fragments was developed in this study. The limit of detection, precision, linearity, and specificity of the assay was evaluated and demonstrated high-quality performance. The prevalence of HCV RNA in the urine of viremic patients infected with HCV was 60% (36/60), as determined by a 62-bp assay. The HCV RNA detection rate and concentration were much lower with a 157-bp assay, and were undetectable with 222- and 304-bp assays. With the 62-bp assay, patients with detectable urine HCV RNA had significantly higher plasma HCV RNA levels ( P < 0.001), and plasma and urine concentrations were significantly positively correlated ( R 2 = 0.708, P < 0.001). The method not only increased the detection rate of urine HCV RNA but also revealed the presence of short HCV RNA fragments in urine, indicating that urine from CHC patients with normal kidney function should not be infectious. In addition, it raised the possibility of urinary HCV RNA as a potential noninvasive marker for therapeutic monitoring of patients with hepatitis C.


Assuntos
Hepatite C Crônica/virologia , RNA Viral/urina , Reação em Cadeia da Polimerase em Tempo Real/métodos , Urina/virologia , Humanos , Prevalência , Sensibilidade e Especificidade
8.
J Clin Lab Anal ; 32(2)2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28440597

RESUMO

BACKGROUND: Due to the significant risk of developing Stevens-Johnson syndrome (SJS) and toxic epidermal necrolysis (TEN), the use of carbamazepine is not recommended in patients carrying the human leukocyte antigen B (HLA-B) *15:02 allele. In an effort to guarantee reliable community-based HLA-B*15:02 testing throughout China, a HLA-B*15:02 genotyping external quality assessment (EQA) program was set up. METHODS: In 2016, 10 genomic DNA samples with known HLA-B*15:02 allele status were sent to 37 laboratories from 16 provinces with a request for routine HLA-B*15:02 screening. The samples were validated using Sanger sequencing by a reference laboratory. Both genotyping results and clinical written reports were evaluated. RESULTS: Thirty-six of the participating laboratories correctly identified the HLA-B*15:02 allele status for all EQA samples. However, one lab failed to identify any positive challenges. The overall analytical sensitivity was 97.3% (180/185 challenges; 95% confidence interval: 93.8%-99.1%) and the analytic specificity was 100% (185/185; 95% confidence interval: 98.0%-100%). A review of the written reports showed that the clinical reporting for HLA-B*15:02 detection should be improved. Some essential information was missing, most notably laboratory information/contact, therapeutic recommendations, and methodology. CONCLUSION: External quality assessment is valuable in assessing and improving the quality of laboratory testing of HLA-B*15:02 allele.


Assuntos
Carbamazepina/efeitos adversos , Antígeno HLA-B15/genética , Síndrome de Stevens-Johnson , Carbamazepina/uso terapêutico , Contraindicações de Medicamentos , Epilepsia/tratamento farmacológico , Predisposição Genética para Doença/genética , Humanos , Fatores de Risco , Sensibilidade e Especificidade , Síndrome de Stevens-Johnson/epidemiologia , Síndrome de Stevens-Johnson/etiologia , Síndrome de Stevens-Johnson/genética
9.
J Clin Lab Anal ; 32(8): e22563, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29708622

RESUMO

BACKGROUND: Tacrolimus is the most widely used immunosuppressant in solid organ transplant patients. The cytochrome P450 3A5 (CYP3A5) has been proved to be associated with tacrolimus dose requirement. Molecular detection for CYP3A5 genotyping is demanded for the optimization of treatments of tacrolimus. METHODS: To achieve the consistency and accuracy of the testing results, the Chinese National Center for Clinical Laboratories (NCCL) organized a national external quality assessment(EQA) program to evaluate the performance of laboratories providing CYP3A5 genotyping. Ten validated DNA samples covering the common genetic polymorphisms of CYP3A5 were delivered to 33 voluntary laboratories, and their detecting results and clinical written reports were evaluated. RESULTS: Thirty-three datasets were received. The corresponding analytical sensitivity was 95.9% (285/297 challenges; 95% confidence interval: 93.0%-97.9%), and the analytical specificity was 95.3% (346/363; 95% confidence interval: 92.6%-97.2%). Thirty of the participating laboratories correctly identified the CYP3A5 allele status for all EQA samples. Three laboratories made genotyping errors, and 2 of them failed to detect any of the homozygotes such as *1/*1 and *3/*3. Twenty-eight CYP3A5*3 tests reports were submitted, but many reports showed a shortage of essential information. No reports fulfilled all the consensus recommendations for pharmacogenetic test result reporting. CONCLUSION: The EQA program highlighted the necessity for an improvement in the accuracy of genotyping for some of the laboratories and a greater education on the reporting of CYP3A5 genotyping results.


Assuntos
Citocromo P-450 CYP3A/genética , Técnicas de Genotipagem/normas , Ensaio de Proficiência Laboratorial/normas , China , Genótipo , Técnicas de Genotipagem/métodos , Rejeição de Enxerto/tratamento farmacológico , Rejeição de Enxerto/prevenção & controle , Humanos , Imunossupressores/uso terapêutico , Ensaio de Proficiência Laboratorial/métodos , Transplante de Órgãos/efeitos adversos , Tacrolimo/uso terapêutico
10.
J Clin Lab Anal ; 32(5): e22391, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29380513

RESUMO

BACKGROUND: KRAS mutations are the key indicator for EGFR monoclonal antibody-targeted therapy and acquired drug resistance, and their accurate detection is critical to the clinical decision-making of colorectal cancer. However, no proper quality control material is available for the current detection methods, particularly next-generation sequencing (NGS). The ideal quality control material for NGS needs to provide both the tumor mutation gene and the matched background genomic DNA, which is uncataloged in public databases, to accurately distinguish germline polymorphisms and somatic mutations. METHODS: We developed a novel KRAS G12V mutant cell line using the clustered regularly interspaced short palindromic repeat (CRISPR)/CRISPR-associated protein 9 (Cas9) technique to make up for the deficiencies in existing quality control material and further validated the feasibility of the cell line as quality control material by amplification refractory mutation system (ARMS), Sanger sequencing, digital PCR (dPCR), and NGS. RESULTS: We verified that the edited cell line specifically had the G12V mutation, and the validation results presented a high consistency among the four methods of detection. The three cell lines screened contained the G12V mutation and the mutation allele fractions of G12V-1, G12V-2, and G12V-3 were 52.01%, 82.06%, and 17.29%, respectively. CONCLUSION: The novel KRAS G12V cell line generated using the CRISPR/Cas9 gene editing system is suitable as a quality control material for all current detection methods and provides a new direction in the development of quality control material.


Assuntos
Sistemas CRISPR-Cas/genética , Glicina/genética , Mutação/genética , Proteínas Proto-Oncogênicas p21(ras)/genética , Valina/genética , Linhagem Celular , Análise Mutacional de DNA , Células HEK293 , Humanos , Transfecção
11.
Oncologist ; 22(11): 1325-1332, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28701573

RESUMO

BACKGROUND: Reports serve as a bridge between laboratories and clinicians, help synthesize an overwhelming amount of raw data into evidence-based medicine, and play a significant role in designing clinical treatments. In an effort to guarantee high-quality epidermal growth factor receptor (EGFR) gene mutation testing and reporting performance, the National Center for Clinical Laboratories launched a proficiency testing (PT) scheme reflecting clinical practices in China since 2014. This study focuses on the quality assessment of gene mutation reports. MATERIALS AND METHODS: Fifty-three laboratories that submitted reports in both 2014 and 2016 EGFR gene mutation PT schemes were selected for report analysis and comparison according to predefined evaluation criteria. RESULTS: The average score for reports from 2014 was 14 out of 30 points. The overall scores for reports from 2016 improved substantially, yielding an average score of 20 out of 30 points. Among the evaluation criteria, general items were well documented in the reports. However, items specific to molecular diagnosis were far from satisfactory, and some items were even missing. CONCLUSION: The quality assessment of clinical written reports from 2014 and 2016 demonstrates that substantial improvements have been made in overall reporting performance. However, not all statements pertaining to important elements met expectations. To continue education, repeated PT schemes need to be executed in a timely fashion to expose and address existing shortcomings in clinical reports. There remains ample room for improvement towards generating concise, comprehensive, and readable reports. IMPLICATIONS FOR PRACTICE: This article compares the quality of clinical gene mutation reports submitted in 2014 to those submitted in 2016 epidermal growth factor receptor proficiency testing schemes, exposes the existing shortcomings, and discusses ways to communicate results more effectively in the future. The findings demonstrate that notable progress was observed in the overall reporting performance. However, key points specific to molecular diagnosis were far from expectation, and some items were even missing. Standardization needs to be emphasized to improve the report format and content. This article provides a reference that laboratories can use to write concise, comprehensive, and readily accessible clinical reports.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/genética , Ensaio de Proficiência Laboratorial/normas , Patologia Molecular/normas , Carcinoma Pulmonar de Células não Pequenas/patologia , China , Receptores ErbB/genética , Feminino , Humanos , Mutação , Garantia da Qualidade dos Cuidados de Saúde
12.
Clin Chem ; 63(9): 1465-1475, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28720677

RESUMO

BACKGROUND: Detection of somatic genomic alterations in tumor-derived cell-free DNA (cfDNA) in the plasma is challenging owing to the low concentrations of cfDNA, variable detection methods, and complex workflows. Moreover, no proper quality control materials are available currently. METHODS: We developed a set of synthetic cfDNA quality control materials (SCQCMs) containing spike-in cfDNA on the basis of micrococcal nuclease digestion carrying somatic mutations as simulated cfDNA and matched genomic DNA as genetic background to emulate paired tumor-normal samples in real clinical tests. Site-directed mutagenesis DNA that contained 1500-2000 bases with single-nucleotide variants or indels and genomic DNA from CRISPR/Cas9 edited cells with EML4-ALK rearrangements was fragmented, quantified, and added into micrococcal nuclease-digested DNA derived from HEK293T cells. To prove their suitability, the SCQCMs were compared with patient-derived plasma samples and validated in a collaborative study that encompassed 11 laboratories. RESULTS: The results of SCQCM analysis by next-generation sequencing showed strong agreement with those of patient-derived plasma samples, including the size profile of cfDNA and the quality control metrics of the sequencing data. More than 95% of laboratories correctly detected the SCQCMs with EGFR T790M, L858R, KRAS G12D, and a deletion in exon 19, as well as with EML4-ALK variant 2. CONCLUSIONS: The SCQCMs were successfully applied in a broad range of settings, methodologies, and informatics techniques. We conclude that SCQCMs can be used as optimal quality controls in test performance assessments for circulating tumor DNA somatic mutation detection.


Assuntos
Biomarcadores Tumorais/sangue , Biópsia/métodos , DNA de Neoplasias/sangue , Biomarcadores Tumorais/genética , Biópsia/normas , DNA de Neoplasias/genética , Variação Genética , Células HEK293 , Humanos , Variações Dependentes do Observador
13.
Clin Chem Lab Med ; 55(12): 1817-1833, 2017 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-28493816

RESUMO

In this era of precision medicine, molecular biology is becoming increasingly significant for the diagnosis and therapeutic management of non-small cell lung cancer. The specimen as the primary element of the whole testing flow is particularly important for maintaining the accuracy of gene alteration testing. Presently, the main sample types applied in routine diagnosis are tissue and cytology biopsies. Liquid biopsies are considered as the most promising alternatives when tissue and cytology samples are not available. Each sample type possesses its own strengths and weaknesses, pertaining to the disparity of sampling, preparation and preservation procedures, the heterogeneity of inter- or intratumors, the tumor cellularity (percentage and number of tumor cells) of specimens, etc., and none of them can individually be a "one size to fit all". Therefore, in this review, we summarized the strengths and weaknesses of different sample types that are widely used in clinical practice, offered solutions to reduce the negative impact of the samples and proposed an optimized strategy for choice of samples during the entire diagnostic course. We hope to provide valuable information to laboratories for choosing optimal clinical specimens to achieve comprehensive functional genomic landscapes and formulate individually tailored treatment plans for NSCLC patients that are in advanced stages.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/tratamento farmacológico , Técnicas de Diagnóstico Molecular , Medicina de Precisão , Carcinoma Pulmonar de Células não Pequenas/genética , Humanos , Neoplasias Pulmonares/genética
14.
Clin Chem Lab Med ; 55(7): 926-933, 2017 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-27845879

RESUMO

Pharmacogenomics has significantly added to our understanding of drug responses in clinical pharmacology, changing the paradigm of treatment decisions. Interrogations of both inherited and somatic variations for therapeutic purposes are increasingly being adopted in clinics, where quality control (QC) materials are required. However, for many pharmacogenomic tests, the acquisition of well-characterized QC materials is often difficult or impossible. In this review, several sources of appropriate QC materials for therapy-associated genetic testing are discussed. Among them, the novel methods for producing renewable controls that resemble patient samples are highlighted. Owing to technological complexity, more efforts are needed to develop proper controls for next-generation sequencing-based assay.


Assuntos
Testes Farmacogenômicos/métodos , Testes Genéticos , Humanos , Mutação , Neoplasias/genética , Neoplasias/terapia , Testes Farmacogenômicos/normas , Controle de Qualidade
15.
Mediators Inflamm ; 2016: 2953072, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27143816

RESUMO

The κ/λ hybrid antibodies in normal human serum were reported recently, but their clinical relevance has not yet been explored. Rheumatoid arthritis (RA) is one of the major joint diseases, and the early diagnosis and treatment of RA remain a challenge. Here, we developed a double-sandwich enzyme-linked immunosorbent assay system to quantify relative serum κ/λ hybrid antibody levels in RA patients, osteoarthritis (OA) patients, and healthy controls (HC) in order to assess their potential use as a serological biomarker of early disease and clinical activity and to preliminarily investigate their immunomodulatory roles in RA. Surprisingly, we found that κ/λ hybrid antibody was markedly increased in both early and established RA. Serum κ/λ hybrid antibody levels were significantly correlated with clinical indexes and inflammatory markers in RA. Further analysis showed a positive correlation between κ/λ hybrid antibody levels and the 28-joint disease activity score (DAS28). In conclusion, serum κ/λ hybrid antibodies in RA were identified for the first time. High levels of κ/λ hybrid antibody may be a useful tool in distinguishing early RA from OA and HC. We suggest κ/λ hybrid antibody as a marker for disease activity. The increased κ/λ hybrid antibodies were associated with inflammatory conditions in RA.


Assuntos
Artrite Reumatoide/sangue , Cadeias kappa de Imunoglobulina/sangue , Cadeias lambda de Imunoglobulina/sangue , Imunoglobulinas/sangue , Inflamação/sangue , Adulto , Idoso , Biomarcadores/sangue , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade
16.
Clin Lab ; 61(12): 1837-44, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26882805

RESUMO

BACKGROUND: The application of traditional internal quality control processes in molecular testing for personalized medicine often proves difficult due to limited control materials. We established a quality control algorithm independent of control materials to monitor routine clinical test results. METHODS: A quality control algorithm was constructed based on the parameters p, P(pos), P(neg), and P(con) calculated by an elementary probability theory. This quality control algorithm was applied in CYP2C19 genotyping and EGFR mutation testing in two molecular diagnostics laboratories in order to illustrate how probabilities are calculated and test results are analyzed. RESULTS: For CYP2C19 genotyping, when the p-values based on 151 specimens from 20 runs were used, three runs were out of control within 20 runs, while two of the three runs became acceptable with p-values calculated with 362 samples in 40 runs. For EGFR mutation testing, one run was rejected because of the low P(pos)-values of deletion in exon 19 with the p-value based on 421 specimens from 40 runs. CONCLUSIONS: The quality control algorithm can be employed to monitor possible false-positives and false-negatives according to the number and distribution of positive results. Noticeably, the evaluation and interpretation of the control results is essential for the decision by a test laboratory to reject a run.


Assuntos
Citocromo P-450 CYP2C19/genética , Receptores ErbB/genética , Mutação , Medicina de Precisão , Controle de Qualidade , Algoritmos , Genótipo , Humanos
17.
Clin Chem Lab Med ; 52(12): 1851-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24945428

RESUMO

BACKGROUND: Laboratory testing for KRAS (v-Ki-ras2 Kirsten rat sarcoma viral oncogene homolog) mutations in metastatic colorectal cancer (mCRC) is performed by various methods in China, but there is no standardized system for proficiency testing or assay performance evaluations. The aim of this study was to evaluate assay and laboratory performance with artificial samples derived from formalin-fixed, paraffin-embedded (FFPE) cell lines. METHODS: Artificial FFPE samples were prepared from cultured cell lines to construct a proficiency panel of 10 samples covering eight KRAS mutations and two wild-type samples. The samples were validated by Sanger sequencing and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The panel was distributed to participating laboratories and their reported results were compared to the reference sequences. RESULTS: The percentages of mutant KRAS alleles in each mutant sample were more than 50% by MALDI-TOF-MS. Sixty-three laboratories reported results, including 41 hospital laboratories and 22 commercial laboratories and reagent manufacturers. Only 55.6% (35/63) of the laboratories correctly identified the mutations in all samples and 33.3% (21/63) reported at least one false-positive result. The false-positive ratio was 7.1% (45/630) and the false-negative ratio was 3.0% (15/504). CONCLUSIONS: KRAS mutations can be missed even by the most sensitive methods if the procedures are not performed correctly. False-positive results are a substantial problem in KRAS testing; laboratories must use sufficient negative controls to identify cross-contamination from PCR-amplified products or between samples during handling and DNA extraction.


Assuntos
Análise Mutacional de DNA , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Proteínas ras/análise , Linhagem Celular Tumoral , China , Neoplasias Colorretais/metabolismo , Neoplasias Colorretais/patologia , Análise Mutacional de DNA/normas , Reações Falso-Positivas , Formaldeído/química , Humanos , Laboratórios , Ensaio de Proficiência Laboratorial , Mutação , Inclusão em Parafina , Reação em Cadeia da Polimerase/normas , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/normas , Proteínas ras/genética
18.
Clin Chim Acta ; 552: 117663, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38008152

RESUMO

BACKGROUND AND AIMS: The incidence and mortality rate of colorectal cancer (CRC) are increasing worldwide. Septin9 methylated (mSEPT9) DNA in circulation can be used as a non-invasive detection method to assist in the early diagnosis of CRC; however, the detection methods and procedures are complicated. This study aimed to evaluate the ability of clinical laboratories to detect Septin9 methylation in plasma cell-free DNA (cfDNA). MATERIALS AND METHODS: We prepared a sample panel consisting of positive and negative Septin9 methylation cells and CRC cells. Three positive samples with different methylation levels, one negative sample and one duplicate sample, two samples containing interference, three different CRC cell samples, and a fictitious case report were included. The panel was distributed to 59 laboratories for mSEPT9 analysis, result comparison, and scoring. RESULTS: The sample panel, validated by National Medical Products Administration (NMPA)-approved tests and targeted bisulfite sequencing, met expectations and could be used for external quality assessment (EQA). Among the 59 laboratories, 55 (93.22%) correctly reported the mSEPT9 results for all samples, while four (6.79%) reported 15 false negatives and were considered improvable. All false negatives originated from four laboratories using laboratory-developed tests (LDTs), with three failing to detect weakly positive samples, samples containing interference, and samples from different CRC cells, and one reported erroneous results on all positive samples. CONCLUSION: Our results illustrated that the detection of mSEPT9 in cfDNA is satisfactory in China. EQA is indispensable because it can help improve the diagnostic capability and quality management of the laboratories, and provide suggestions for the problems existing in mSEPT9 detection.


Assuntos
Ácidos Nucleicos Livres , Neoplasias Colorretais , Humanos , Metilação de DNA , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/genética , Laboratórios Clínicos , Biomarcadores Tumorais , Septinas/genética , Septinas/metabolismo
19.
NPJ Precis Oncol ; 8(1): 18, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263314

RESUMO

Targeted panel-based tumor mutation burden (TMB) assays are widely employed to guide immunotherapy for patients with solid tumors. However, the accuracy and consistency of this method can be compromised due to the variability in technical details across different laboratories, particularly in terms of panel size, somatic mutation detection and TMB calculation rules. Currently, systematic evaluations of the impact of these technical factors on existing assays and best practice recommendations remain lacking. We assessed the performance of 50 participating panel-based TMB assays involving 38 unique methods using cell line samples. In silico experiments utilizing TCGA MC3 datasets were performed to further dissect the impact of technical factors. Here we show that the panel sizes beyond 1.04 Mb and 389 genes are necessary for the basic discrete accuracy, as determined by over 40,000 synthetic panels. The somatic mutation detection should maintain a reciprocal gap of recall and precision less than 0.179 for reliable psTMB calculation results. The inclusion of synonymous, nonsense and hotspot mutations could enhance the accuracy of panel-based TMB assay. A 5% variant allele frequency cut-off is suitable for TMB assays using tumor samples with at least 20% tumor purity. In conclusion, this multicenter study elucidates the major technical factors as sources of variability in panel-based TMB assays and proposed comprehensive recommendations for the enhancement of accuracy and consistency. These findings will assist clinical laboratories in optimizing the methodological details through bioinformatic experiments to enhance the reliability of panel-based methods.

20.
Anal Chim Acta ; 1287: 342126, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38182396

RESUMO

BACKGROUND: The detection of cancer gene mutations in biofluids plays a pivotal role in revolutionizing disease diagnosis. The presence of a large background of wild-type sequences poses a challenge to liquid biopsy of tumor mutation genes. Suppressing the detection of wild-type sequences can reduce their interference, however, due to the minimal difference between mutant and wild-type sequences (such as single nucleotide variants differing by only one nucleotide), how to suppress the detection of wild-type sequences to the greatest extent without compromising the sensitivity of mutant sequence detection remains to be explored. SIGNIFICANCE: The RLP system addresses the incompatibility between RPA and RT-PCR reactions through a physical separation strategy. Besides, due to the remarkable flexibility of locked nucleic acid probes, the RLP system emerges as a potent tool for detecting mutations across diverse genes. It excels in sensitivity and speed, tolerates plasma matrix, and is cost-effective. This bodes well for advancing the field of precision medicine. RESULTS: The recombinase-assisted locked nucleic acid (LNA) probe-mediated dual amplification biosensing platform (namely RLP), which combines recombinase polymerase amplification (RPA) and LNA clamp PCR method in one tube, enabling highly sensitive and selective detection of EGFR T790M mutation under the help of well-designed LNA probes. This technique can quantify DNA targets with a limit of detection (LoD) at the single copy level and identify point mutation with mutant allelic fractions as low as 0.007 % in 45 min. Moreover, RLP has the potential for the direct detection of plasma samples without the need for nucleic acid extraction and the cost of a single test is less than 1USD. Furthermore, the RLP system is a cascading dual amplification reaction conducted in a single tube, which eliminates the risk of cross-contamination associated with opening multiple tubes and ensures the reliability of the results.


Assuntos
Técnicas Biossensoriais , Receptores ErbB , Neoplasias Pulmonares , Humanos , Receptores ErbB/química , Receptores ErbB/genética , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Mutação , Nucleotídeos , Recombinases , Reprodutibilidade dos Testes , Técnicas Biossensoriais/métodos