Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Diabetes Obes Metab ; 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39300963

RESUMO

AIM: Automated insulin delivery (AID) systems have demonstrated improved glycaemic outcomes in people with type 1 diabetes (T1D), yet limited data exist on these systems in very young children and their impact on caregivers. We evaluated psychosocial outcomes following use of the tubeless Omnipod® 5 AID System in caregivers of very young children. MATERIALS AND METHODS: This 3-month single-arm, multicentre, pivotal clinical trial enrolled 80 children aged 2.0-5.9 years with T1D to use the Omnipod 5 AID System. Caregivers completed questionnaires assessing psychosocial outcomes-diabetes distress (Problem Areas in Diabetes), hypoglycaemia confidence (Hypoglycemia Confidence Scale), well-being (World Health Organization 5 Well-Being Index), sleep quality (Pittsburgh Sleep Quality Index), insulin delivery satisfaction (Insulin Delivery Satisfaction Survey) and system usability (System Usability Scale) at baseline with standard therapy and after 3 months of AID use. RESULTS: Following 3 months of Omnipod 5 use, caregivers experienced significant improvements across all measures, including diabetes-related psychosocial outcomes (Problem Areas in Diabetes; p < 0.0001, Hypoglycemia Confidence Scale; p < 0.01), well-being (World Health Organization 5 Well-Being Index; p < 0.0001) and perceived system usability (System Usability Scale; p < 0.0001). Significant improvements were seen in the Pittsburgh Sleep Quality Index total score and the overall sleep quality, sleep duration and efficiency subscales (all p < 0.05). Insulin Delivery Satisfaction Survey scores improved on all subscales (greater satisfaction, reduced burden and reduced inconvenience; all p < 0.0001). CONCLUSIONS: Caregivers face unique challenges when managing T1D in very young children. While glycaemic metrics have unquestioned importance, these results evaluating psychosocial outcomes reveal additional meaningful benefits and suggest that the Omnipod 5 AID System alleviates some of the burdens caregivers face with diabetes management.

2.
Molecules ; 27(24)2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36558022

RESUMO

Breast cancer (BC), the most common malignancy in women, results from significant alterations in genetic and epigenetic mechanisms that alter multiple signaling pathways in growth and malignant progression, leading to limited long-term survival. Current studies with numerous drug therapies have shown that BC is a complex disease with tumor heterogeneity, rapidity, and dynamics of the tumor microenvironment that result in resistance to existing therapy. Targeting a single cell-signaling pathway is unlikely to treat or prevent BC. Curcumin (a natural yellow pigment), the principal ingredient in the spice turmeric, is well-documented for its diverse pharmacological properties including anti-cancer activity. However, its clinical application has been limited because of its low solubility, stability, and bioavailability. To overcome the limitation of curcumin, several modified curcumin conjugates and curcumin mimics were developed and studied for their anti-cancer properties. In this review, we have focused on the application of curcumin mimics and their conjugates for breast cancer.


Assuntos
Antineoplásicos , Neoplasias da Mama , Curcumina , Humanos , Feminino , Curcumina/farmacologia , Curcumina/uso terapêutico , Neoplasias da Mama/metabolismo , Solubilidade , Transdução de Sinais , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Microambiente Tumoral
3.
J Pediatr ; 199: 263-266, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29699796

RESUMO

The prevalence of nephrocalcinosis in persons with pseudohypoparathyroidism has not been systematically examined. We conducted a retrospective study of renal imaging and biochemical results in 19 patients with pseudohypoparathyroidism with 49 imaging assessments. No cases of nephrocalcinosis were identified. Routine screening for nephrocalcinosis in pseudohypoparathyroidism may not be necessary.


Assuntos
Nefrocalcinose/diagnóstico , Nefrocalcinose/etiologia , Pseudo-Hipoparatireoidismo/complicações , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Programas de Rastreamento , Nefrocalcinose/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Risco
5.
Am J Biol Anthropol ; : e25009, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39238322

RESUMO

OBJECTIVES: Bioarchaeological studies have provided important information about mortality patterns during the second pandemic of plague, including the Black Death, but most to date have focused on European contexts. This study represents a spatial contribution to plague bioarchaeology, focusing on Central Asia, the origin of the second pandemic. We examine the relationship between stature and plague mortality during an outbreak of plague at Kara-Djigach in northern Kyrgyzstan in 1338-1339, the earliest archaeological site known to contain victims of the Black Death in Eurasia. METHODS: This study uses epigraphic data and in situ measurements from the Syriac Christian cemeteries at Kara-Djigach, obtained from field notes from excavations conducted by Russian archaeologists in the 1880s (n = 34 individuals). The epigraphic data provide detailed information about the interred individuals, including occupations, year of death, and gender. In situ measurements provide data on adult stature. This study uses chi-square and Fisher's exact tests to examine relationships between stature and plague at the site. RESULTS: We find evidence that relatively short people were disproportionately affected by plague when compared with non-plague years. DISCUSSION: These results might reflect increased mortality risks from plague based on exposure to early life biological stress events.

6.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38277156

RESUMO

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Pré-Escolar , Insulina/administração & dosagem , Insulina/uso terapêutico , Feminino , Masculino , Glicemia/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas/análise , Hipoglicemia/prevenção & controle , Resultado do Tratamento , Controle Glicêmico/métodos , Automonitorização da Glicemia
7.
Diabetes Technol Ther ; 26(1): 11-23, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37850941

RESUMO

Background: The Omnipod® 5 Automated Insulin Delivery (AID) System was shown to be safe and effective following 3 months of use in people with type 1 diabetes (T1D); however, data on the durability of these results are limited. This study evaluated the long-term safety and effectiveness of Omnipod 5 use in people with T1D during up to 2 years of use. Materials and Methods: After a 3-month single-arm, multicenter, pivotal trial in children (6-13.9 years) and adolescents/adults (14-70 years), participants could continue system use in an extension phase. HbA1c was measured every 3 months for up to 15 months; continuous glucose monitor metrics were collected for up to 2 years. Results: Participants (N = 224) completed median (interquartile range) 22.3 (21.7, 22.7) months of AID. HbA1c was reduced in the pivotal trial from 7.7% ± 0.9% in children and 7.2% ± 0.9% in adolescents/adults to 7.0% ± 0.6% and 6.8% ± 0.7%, respectively, (P < 0.0001), and was maintained at 7.2% ± 0.7% and 6.9% ± 0.6% after 15 months (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 52.4% ± 15.6% in children and 63.6% ± 16.5% in adolescents/adults at baseline to 67.9% ± 8.0% and 73.8% ± 10.8%, respectively, during the pivotal trial (P < 0.0001) and was maintained at 65.9% ± 8.9% and 72.9% ± 11.3% during the extension (P < 0.0001 from baseline). One episode of diabetic ketoacidosis and seven episodes of severe hypoglycemia occurred during the extension. Children and adolescents/adults spent median 96.1% and 96.3% of time in Automated Mode, respectively. Conclusion: Our study supports that long-term use of the Omnipod 5 AID System can safely maintain improvements in glycemic outcomes for up to 2 years of use in people with T1D. Clinical Trials Registration Number: NCT04196140.


Assuntos
Diabetes Mellitus Tipo 1 , Adulto , Criança , Humanos , Adolescente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Hemoglobinas Glicadas , Sistemas de Infusão de Insulina , Glicemia , Automonitorização da Glicemia
8.
Diabetes Care ; 45(8): 1907-1910, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35678724

RESUMO

OBJECTIVE: Very young children with type 1 diabetes often struggle to achieve glycemic targets, putting them at risk for long-term complications and creating an immense management burden for caregivers. We conducted the first evaluation of the Omnipod 5 Automated Insulin Delivery System in this population. RESEARCH DESIGN AND METHODS: A total of 80 children aged 2.0-5.9 years used the investigational system in a single-arm study for 13 weeks following 14 days of baseline data collection with their usual therapy. RESULTS: There were no episodes of severe hypoglycemia or diabetic ketoacidosis. By study end, HbA1c decreased by 0.55% (6.0 mmol/mol) (P < 0.0001). Time with sensor glucose levels in target range 70-180 mg/dL increased by 10.9%, or 2.6 h/day (P < 0.0001), while time with levels <70 mg/dL declined by median 0.27% (P = 0.0204). CONCLUSIONS: Use of the automated insulin delivery system was safe, and participants experienced improved glycemic measures and reduced hypoglycemia during the study phase compared with baseline.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Glicemia , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/epidemiologia , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/epidemiologia , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico
9.
Diabetes Care ; 44(7): 1630-1640, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34099518

RESUMO

OBJECTIVE: Advances in diabetes technology have transformed the treatment paradigm for type 1 diabetes, yet the burden of disease is significant. We report on a pivotal safety study of the first tubeless, on-body automated insulin delivery system with customizable glycemic targets. RESEARCH DESIGN AND METHODS: This single-arm, multicenter, prospective study enrolled 112 children (age 6-13.9 years) and 129 adults (age 14-70 years). A 2-week standard therapy phase (usual insulin regimen) was followed by 3 months of automated insulin delivery. Primary safety outcomes were incidence of severe hypoglycemia and diabetic ketoacidosis. Primary effectiveness outcomes were change in HbA1c and percent time in sensor glucose range 70-180 mg/dL ("time in range"). RESULTS: A total of 235 participants (98% of enrolled, including 111 children and 124 adults) completed the study. HbA1c was significantly reduced in children by 0.71% (7.8 mmol/mol) (mean ± SD: 7.67 ± 0.95% to 6.99 ± 0.63% [60 ± 10.4 mmol/mol to 53 ± 6.9 mmol/mol], P < 0.0001) and in adults by 0.38% (4.2 mmol/mol) (7.16 ± 0.86% to 6.78 ± 0.68% [55 ± 9.4 mmol/mol to 51 ± 7.4 mmol/mol], P < 0.0001). Time in range was improved from standard therapy by 15.6 ± 11.5% or 3.7 h/day in children and 9.3 ± 11.8% or 2.2 h/day in adults (both P < 0.0001). This was accomplished with a reduction in time in hypoglycemia <70 mg/dL among adults (median [interquartile range]: 2.00% [0.63, 4.06] to 1.09% [0.46, 1.75], P < 0.0001), while this parameter remained the same in children. There were three severe hypoglycemia events not attributable to automated insulin delivery malfunction and one diabetic ketoacidosis event from an infusion site failure. CONCLUSIONS: This tubeless automated insulin delivery system was safe and allowed participants to significantly improve HbA1c levels and time in target glucose range with a very low occurrence of hypoglycemia.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Adolescente , Adulto , Idoso , Glicemia , Criança , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes , Sistemas de Infusão de Insulina , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA