Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 530(7588): 71-6, 2016 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-26779949

RESUMO

Many procedures in modern clinical medicine rely on the use of electronic implants in treating conditions that range from acute coronary events to traumatic injury. However, standard permanent electronic hardware acts as a nidus for infection: bacteria form biofilms along percutaneous wires, or seed haematogenously, with the potential to migrate within the body and to provoke immune-mediated pathological tissue reactions. The associated surgical retrieval procedures, meanwhile, subject patients to the distress associated with re-operation and expose them to additional complications. Here, we report materials, device architectures, integration strategies, and in vivo demonstrations in rats of implantable, multifunctional silicon sensors for the brain, for which all of the constituent materials naturally resorb via hydrolysis and/or metabolic action, eliminating the need for extraction. Continuous monitoring of intracranial pressure and temperature illustrates functionality essential to the treatment of traumatic brain injury; the measurement performance of our resorbable devices compares favourably with that of non-resorbable clinical standards. In our experiments, insulated percutaneous wires connect to an externally mounted, miniaturized wireless potentiostat for data transmission. In a separate set-up, we connect a sensor to an implanted (but only partially resorbable) data-communication system, proving the principle that there is no need for any percutaneous wiring. The devices can be adapted to sense fluid flow, motion, pH or thermal characteristics, in formats that are compatible with the body's abdomen and extremities, as well as the deep brain, suggesting that the sensors might meet many needs in clinical medicine.


Assuntos
Implantes Absorvíveis , Encéfalo/metabolismo , Eletrônica/instrumentação , Monitorização Fisiológica/instrumentação , Próteses e Implantes , Silício , Implantes Absorvíveis/efeitos adversos , Administração Cutânea , Animais , Temperatura Corporal , Encéfalo/cirurgia , Desenho de Equipamento , Hidrólise , Masculino , Monitorização Fisiológica/efeitos adversos , Especificidade de Órgãos , Pressão , Próteses e Implantes/efeitos adversos , Ratos , Ratos Endogâmicos Lew , Telemetria/instrumentação , Tecnologia sem Fio/instrumentação
2.
Anal Chem ; 88(5): 2666-74, 2016 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-26815205

RESUMO

This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density <10(-4) g/cm(3) for macroscopic objects (>mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

3.
Nat Med ; 24(12): 1830-1836, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30297910

RESUMO

Peripheral nerve injuries represent a significant problem in public health, constituting 2-5% of all trauma cases1. For severe nerve injuries, even advanced forms of clinical intervention often lead to incomplete and unsatisfactory motor and/or sensory function2. Numerous studies report the potential of pharmacological approaches (for example, growth factors, immunosuppressants) to accelerate and enhance nerve regeneration in rodent models3-10. Unfortunately, few have had a positive impact in clinical practice. Direct intraoperative electrical stimulation of injured nerve tissue proximal to the site of repair has been demonstrated to enhance and accelerate functional recovery11,12, suggesting a novel nonpharmacological, bioelectric form of therapy that could complement existing surgical approaches. A significant limitation of this technique is that existing protocols are constrained to intraoperative use and limited therapeutic benefits13. Herein we introduce (i) a platform for wireless, programmable electrical peripheral nerve stimulation, built with a collection of circuit elements and substrates that are entirely bioresorbable and biocompatible, and (ii) the first reported demonstration of enhanced neuroregeneration and functional recovery in rodent models as a result of multiple episodes of electrical stimulation of injured nervous tissue.


Assuntos
Estimulação Elétrica/métodos , Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/terapia , Cicatrização/fisiologia , Implantes Absorvíveis/normas , Estimulação Elétrica/instrumentação , Humanos , Traumatismos dos Nervos Periféricos/fisiopatologia , Recuperação de Função Fisiológica , Tecnologia sem Fio
4.
Adv Mater ; 29(8)2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28004863

RESUMO

Scissoring in thick bars suppresses buckling behavior in serpentine traces that have thicknesses greater than their widths, as detailed in a systematic set of analytical and experimental studies. Scissoring in thick copper traces enables elastic stretchability as large as ≈350%, corresponding to a sixfold improvement over previously reported values for thin geometries (≈60%).

5.
Adv Mater ; 27(9): 1587-92, 2015 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-25589230

RESUMO

Magnetic levitation (MagLev) enables rapid and non-destructive quality control of plastic parts. The feasibility of MagLev as a method to: i) rapidly assess injection-molded plastic parts for defects during process optimization, ii) monitor the degradation of plastics after exposure to harsh environmental conditions, and iii) detect counterfeit polymers by density is demonstrated.


Assuntos
Magnetismo , Movimento (Física) , Plásticos , Simulação por Computador , Desenho de Equipamento , Fenômenos Magnéticos , Modelos Teóricos , Plásticos/efeitos da radiação , Raios Ultravioleta/efeitos adversos
6.
NPG Asia Mater ; 72015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27175221

RESUMO

On-demand, localized release of drugs in precisely controlled, patient-specific time sequences represents an ideal scenario for pharmacological treatment of various forms of hormone imbalances, malignant cancers, osteoporosis, diabetic conditions and others. We present a wirelessly operated, implantable drug delivery system that offers such capabilities in a form that undergoes complete bioresorption after an engineered functional period, thereby obviating the need for surgical extraction. The device architecture combines thermally actuated lipid membranes embedded with multiple types of drugs, configured in spatial arrays and co-located with individually addressable, wireless elements for Joule heating. The result provides the ability for externally triggered, precision dosage of drugs with high levels of control and negligible unwanted leakage, all without the need for surgical removal. In vitro and in vivo investigations reveal all of the underlying operational and materials aspects, as well as the basic efficacy and biocompatibility of these systems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA