Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Anaesthesia ; 73(6): 738-745, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29230797

RESUMO

We investigated the association of pre-operative activity, reported by the Duke Activity Score Index, Short Form-12 and measured by an accelerometer worn at home, with five cardiopulmonary exercise variables: peak power; peak oxygen consumption; anaerobic threshold; and ventilatory equivalents for oxygen and carbon dioxide. Fifty patients scheduled for major surgery underwent a standard pre-operative cardiopulmonary exercise test and wore a chest-mounted triaxial accelerometer for a mean (SD) duration of 3.2 (0.4) days. The Duke Activity Score Index and six accelerometer variables were significantly correlated with all five cardiopulmonary exercise variables, Pearson correlation coefficients 0.5-0.7, p = 0.02 to p < 0.001. Our results can guide future studies that measure physical activity for pre-operative assessment and interventions.


Assuntos
Acelerometria/métodos , Teste de Esforço , Exercício Físico/fisiologia , Idoso , Algoritmos , Limiar Anaeróbio/fisiologia , Anestesia , Dióxido de Carbono/sangue , Estudos de Viabilidade , Feminino , Testes de Função Cardíaca , Humanos , Masculino , Oxigênio/sangue , Consumo de Oxigênio/fisiologia , Testes de Função Respiratória
2.
Phys Rev Lett ; 109(3): 032505, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22861843

RESUMO

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3) kg(-1) yr(-1) keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νßß)(136Xe)>1.6×10(25) yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.

3.
Phys Rev Lett ; 107(21): 212501, 2011 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-22181874

RESUMO

We report the observation of two-neutrino double-beta decay in (136)Xe with T(1/2) = 2.11 ± 0.04(stat) ± 0.21(syst) × 10(21) yr. This second-order process, predicted by the standard model, has been observed for several nuclei but not for (136)Xe. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrinoless double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

4.
Pediatrics ; 74(5): 828-31, 1984 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-6493878

RESUMO

Although fiberoptic, upper gastrointestinal (UGI) endoscopy has become an accepted diagnostic technique in the older child and adult, concerns about safety have limited the use of this procedure in infants. A 1-year experience with 49 upper gastrointestinal endoscopies in infants less than 25 months of age is reported. There were varied indications for the procedures, including upper gastrointestinal hemorrhage and obstruction, but evaluation for esophagitis secondary to gastroesophageal reflux was most common. Procedures were performed without sedation in 45% of all infants studied, including 87% of infants less than 3 months of age; procedures were well tolerated. General anesthesia was used on only three occasions. A thorough examination was always possible, and biopsies were taken whenever indicated. Only one complication, transient bradycardia, occurred in a critically ill infant. This experience demonstrates that upper gastrointestinal endoscopy is a safe and effective diagnostic aid in infants, and it can often be performed with little or no sedation.


Assuntos
Endoscopia , Gastroenteropatias/diagnóstico , Anestesia Geral , Bradicardia/etiologia , Pré-Escolar , Duodenoscopia , Endoscopia/efeitos adversos , Endoscopia/métodos , Esofagite Péptica/diagnóstico , Esofagite Péptica/etiologia , Esofagoscopia , Estudos de Avaliação como Assunto , Refluxo Gastroesofágico/diagnóstico , Gastroscopia , Humanos , Hipnóticos e Sedativos/uso terapêutico , Lactente , Recém-Nascido , Pré-Medicação
5.
MLO Med Lab Obs ; 25(9): 50-2, 54, 56, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10128452

RESUMO

The key is an orientation checklist of procedures that defines required levels of competency and records each level a new employee achieves.


Assuntos
Capacitação em Serviço/métodos , Laboratórios Hospitalares/normas , Pessoal de Laboratório Médico/educação , Controle de Formulários e Registros , Laboratórios Hospitalares/organização & administração , Técnicas de Planejamento , Estados Unidos
6.
Rev Sci Instrum ; 82(10): 105114, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22047336

RESUMO

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon time projection chamber of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute of xenon gas with 750 Torr differential pressure.

7.
Rev Sci Instrum ; 81(11): 113301, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21133463

RESUMO

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating (148)Gd onto a silicon α-particle detector and vapor depositing a layer of BaF(2) over it. (144)Sm recoils from the alpha decay of (148)Gd are used to dislodge Ba(+) ions from the BaF(2) layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba(+) emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

10.
Am J Nurs ; 66(1): 106-7, 1966 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-5174424

Assuntos
Enfermagem , Humanos
13.
RN ; 30(2): 78-84, 1967 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-5180673
14.
J Pediatr ; 107(6): 881-4, 1985 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-4067745

RESUMO

A control group of infants was evaluated to determine criteria for the diagnosis of histologic esophagitis. Based on our observations, histologic esophagitis was defined as four or more intraepithelial neutrophils or one eosinophil per high power field or both. Esophageal biopsy specimens from 33 consecutive infants younger than 2 years who had been examined for clinically significant gastroesophageal reflux (GER) were reviewed for histologic esophagitis. Endoscopy had been performed in each patient, and 4.1 +/- 1.1 (mean +/- SD) biopsy specimens had been obtained above the distal 20% of the esophagus. Twenty (61%) infants had histologic esophagitis, including 15 with intraepithelial eosinophils alone, one with intraepithelial neutrophils alone, and four with both. Older infants (7 to 24 months) with histologic esophagitis were more likely to have moderate to severe inflammation than were infants younger than 7 months of age (P = 0.01). Endoscopic evidence for gross esophagitis was found in six (18%) infants; of these, five had abnormal biopsies, including four with moderate to severe inflammation. Among the 27 infants with a grossly normal esophagus, 14 (52%) had histologic esophagitis, including nine (33%) with moderate to severe inflammation. We conclude that in infants with clinically significant GER: (1) esophagitis is common, (2) histologic esophagitis frequently occurs in the absence of gross endoscopic findings, (3) the likelihood of moderate to severe inflammation increases after 6 months of age, and (4) intraepithelial eosinophils are a sensitive marker for acute inflammation in association with GER.


Assuntos
Esofagite Péptica/patologia , Esôfago/patologia , Biópsia , Endoscopia , Eosinófilos/patologia , Esofagite Péptica/diagnóstico , Humanos , Lactente , Neutrófilos/patologia
15.
Phys Rev Lett ; 92(10): 102004, 2004 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-15089201

RESUMO

Data from the Sudbury Neutrino Observatory have been used to constrain the lifetime for nucleon decay to "invisible" modes, such as n-->3nu. The analysis was based on a search for gamma rays from the deexcitation of the residual nucleus that would result from the disappearance of either a proton or neutron from 16O. A limit of tau(inv)>2 x 10(29) yr is obtained at 90% confidence for either neutron- or proton-decay modes. This is about an order of magnitude more stringent than previous constraints on invisible proton-decay modes and 400 times more stringent than similar neutron modes.

16.
Phys Rev Lett ; 92(18): 181301, 2004 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-15169480

RESUMO

The Sudbury Neutrino Observatory has precisely determined the total active (nu(x)) 8B solar neutrino flux without assumptions about the energy dependence of the nu(e) survival probability. The measurements were made with dissolved NaCl in heavy water to enhance the sensitivity and signature for neutral-current interactions. The flux is found to be 5.21 +/- 0.27(stat)+/-0.38(syst) x 10(6) cm(-2) s(-1), in agreement with previous measurements and standard solar models. A global analysis of these and other solar and reactor neutrino results yields Deltam(2)=7.1(+1.2)(-0.6) x 10(-5) eV(2) and theta=32.5(+2.4)(-2.3) degrees. Maximal mixing is rejected at the equivalent of 5.4 standard deviations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA