Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
J Nucl Cardiol ; 32: 101796, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278706

RESUMO

BACKGROUND: Differences in tracer characteristics may influence the interpretation of positron emission tomography myocardial perfusion imaging (MPI). We compare the reading of MPIs with a low-extraction retention tracer (82Rb) and a high-extraction non-retention tracer (15O-water) in a selected cohort of patients with known coronary artery disease (CAD). METHODS: Thirty-nine patients with known CAD referred to 82Rb MPI due to angina underwent rest and stress imaging with both tracers and experienced MPI readers provided blinded consensus reads of all studies. In addition, a comparison of regional and global quantitative measures of perfusion was performed. RESULTS: The results showed 74 % agreement in the reading of 82Rb and 15O-water MPI for regional reversible ischemia and global disease, and 82 % agreement for regional irreversible ischemia. The 15O-water MPI identified more cases of global disease (n = 12 (15O-water) vs n = 4 (82Rb), p = 0.03), whereas differences in reversible ischemia (n = 22 vs n = 16, p = 0.11) and, irreversible ischemia (n = 8 vs n = 11, p = 0.45) were not significant. The correlation between myocardial blood flow measured using the two tracers was similar to previous studies (R2 = 0.78) with wide limits of agreement (-0.93 to 0.84 ml/g/min). CONCLUSIONS: Agreement between consensus readings of 82Rb and 15O-water MPI was good in patients with known CAD. In this limited size study, no significant differences in the identification of reversible and irreversible ischemia found, whereas 15O-water MPI had a higher positive rate for suspected global disease.


Assuntos
Isquemia , Radioisótopos de Oxigênio , Tomografia por Emissão de Pósitrons , Humanos , Radioisótopos de Rubídio
2.
Circulation ; 139(18): 2129-2141, 2019 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-30884964

RESUMO

BACKGROUND: Myocardial utilization of 3-hydroxybutyrate (3-OHB) is increased in patients with heart failure and reduced ejection fraction (HFrEF). However, the cardiovascular effects of increased circulating plasma-3-OHB levels in these patients are unknown. Consequently, the authors' aim was to modulate circulating 3-OHB levels in HFrEF patients and evaluate: (1) changes in cardiac output (CO); (2) a potential dose-response relationship between 3-OHB levels and CO; (3) the impact on myocardial external energy efficiency (MEE) and oxygen consumption (MVO2); and (4) whether the cardiovascular response differed between HFrEF patients and age-matched volunteers. METHODS: Study 1: 16 chronic HFrEF patients (left ventricular ejection fraction: 37±3%) were randomized in a crossover design to 3-hour of 3-OHB or placebo infusion. Patients were monitored invasively with a Swan-Ganz catheter and with echocardiography. Study 2: In a dose-response study, 8 HFrEF patients were examined at increasing 3-OHB infusion rates. Study 3 to 4: 10 HFrEF patients and 10 age-matched volunteers were randomized in a crossover design to 3-hour 3-OHB or placebo infusion. MEE and MVO2 were evaluated using 11C-acetate positron emission tomography. RESULTS: 3-OHB infusion increased circulating levels of plasma 3-OHB from 0.4±0.3 to 3.3±0.4 mM ( P<0.001). CO rose by 2.0±0.2 L/min ( P<0.001) because of an increase in stroke volume of 20±2 mL ( P<0.001) and heart rate of 7±2 beats per minute (bpm) ( P<0.001). Left ventricular ejection fraction increased 8±1% ( P<0.001) numerically. There was a dose-response relationship with a significant CO increase of 0.3 L/min already at plasma-3-OHB levels of 0.7 mM ( P<0.001). 3-OHB increased MVO2 without altering MEE. The response to 3-OHB infusion in terms of MEE and CO did not differ between HFrEF patents and age-matched volunteers. CONCLUSIONS: 3-OHB has beneficial hemodynamic effects in HFrEF patients without impairing MEE. These beneficial effects are detectable in the physiological concentration range of circulating 3-OHB levels. The hemodynamic effects of 3-OHB were observed in both HFrEF patients and age-matched volunteers. 3-OHB may potentially constitute a novel treatment principle in HFrEF patients.


Assuntos
Ácido 3-Hidroxibutírico , Insuficiência Cardíaca , Frequência Cardíaca/efeitos dos fármacos , Tomografia por Emissão de Pósitrons , Volume Sistólico/efeitos dos fármacos , Ácido 3-Hidroxibutírico/farmacocinética , Ácido 3-Hidroxibutírico/farmacologia , Acetatos/farmacologia , Idoso , Radioisótopos de Carbono/farmacologia , Doença Crônica , Feminino , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Consumo de Oxigênio/efeitos dos fármacos
3.
J Nucl Cardiol ; 26(2): 585-597, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-28770459

RESUMO

BACKGROUND: The glucagon-like peptide-1 analog liraglutide increases heart rate and may be associated with more cardiac events in chronic heart failure (CHF) patients. We studied whether this could be ascribed to effects on myocardial glucose uptake (MGU), myocardial blood flow (MBF) and MBF reserve (MFR). METHODS AND RESULTS: CHF patients with left ventricular ejection fraction ≤45% and without type 2 diabetes were randomized to liraglutide (N = 18) 1.8 mg once daily or placebo (N = 18) for 24 weeks in a double-blinded design. Changes in MGU during an oral glucose tolerance test (OGTT) and changes in MBF and MFR from baseline to follow-up were measured quantitatively by 18F-FDG and 15O-H2O positron emission tomography. Compared with placebo, liraglutide reduced weight (P = 0.03), HbA1c (P = 0.03) and the 2-hour glucose value during the OGTT (P = 0.004). Despite this, changes in MGU (P = 0.98), MBF (P = 0.76) and MFR (P = 0.89) from baseline to follow-up did not differ between groups. Furthermore, there was no association between the level of insulin resistance at baseline and changes in MGU in patients treated with liraglutide. CONCLUSION: Liraglutide did not affect MGU, MBF, or MFR in non-diabetic CHF patients. Any potential increase in cardiac events in these patients seems not to involve changes in MGU, MBF, or MFR. TRIAL REGISTRATION: Trial registry: http://www.ClinicalTrials.org . Identifier: NCT01472640. Url: https://clinicaltrials.gov/ct2/show/NCT01472640?term=NCT01472640&rank=1.


Assuntos
Glicemia/metabolismo , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Liraglutida/uso terapêutico , Miocárdio/metabolismo , Administração Oral , Idoso , Velocidade do Fluxo Sanguíneo , Doença Crônica , Circulação Coronária , Dinamarca/epidemiologia , Método Duplo-Cego , Ecocardiografia , Feminino , Teste de Tolerância a Glucose , Humanos , Masculino , Pessoa de Meia-Idade , Perfusão , Volume Sistólico
4.
J Nucl Cardiol ; 25(1): 169-176, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-27473218

RESUMO

BACKGROUND: In type 2 diabetes, a decrease in myocardial glucose uptake (MGU) may lower glucose oxidation and contribute to progression of chronic heart failure (CHF). However, it is unsettled whether CHF patients with prediabetes have abnormal MGU and myocardial blood flow (MBF) during normal physiological conditions. METHODS AND RESULTS: We studied 35 patients with CHF and reduced left ventricular ejections fraction (34 ± 9%) without overt T2D (mean HbA1c: 40 ± 4 mmol/mol) using echocardiography and quantitative measurements of MGU by 18F-FDG-PET and perfusion by 15O-H2O-PET. An oral glucose tolerance test (OGTT) was performed during the FDG-PET, which identified 17 patients with abnormal and 18 patients with normal glucometabolic response. Global MGU was higher in patients with normal OGTT response (0.31 ± 0.09 µmol/g/min) compared with patients with abnormal OGTT response (0.25 ± 0.09 µmol/g/min) (P = 0.05). MBF (P = 0.22) and myocardial flow reserve (MFR) (P = 0.83) were similar in the study groups. The reduced MGU in prediabetic patients was attributable to reduced MGU in viable myocardium with normal MFR (P < 0.001). CONCLUSION: CHF patients with prediabetes have reduced MGU in segments with preserved MFR as compared to CHF patients with normal glucose tolerance. Whether reversal of these myocardial abnormalities can improve outcome needs to be investigated in large-scale studies.


Assuntos
Complicações do Diabetes , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico por imagem , Miocárdio/metabolismo , Estado Pré-Diabético/complicações , Idoso , Cicatriz/diagnóstico por imagem , Circulação Coronária , Diabetes Mellitus Tipo 2/complicações , Progressão da Doença , Ecocardiografia , Feminino , Fluordesoxiglucose F18 , Glucose/farmacocinética , Teste de Tolerância a Glucose , Coração/diagnóstico por imagem , Humanos , Liraglutida/administração & dosagem , Masculino , Síndrome Metabólica/complicações , Pessoa de Meia-Idade , Perfusão , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Período Pós-Prandial , Disfunção Ventricular Esquerda/diagnóstico por imagem
5.
J Nucl Cardiol ; 25(6): 1929-1936, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29855984

RESUMO

BACKGROUND: Myocardial efficiency measured by 11C-acetate positron emission tomography (PET) has successfully been used in clinical research to quantify mechanoenergetic coupling. The objective of this study was to establish the repeatability of myocardial external efficiency (MEE) and work metabolic index (WMI) by non-invasive concepts. METHODS AND RESULTS: Ten healthy volunteers (63 ± 4 years) were examined twice, one week apart, using 11C-acetate PET, cardiovascular magnetic resonance (CMR), and echocardiography. Myocardial oxygen consumption from PET was combined with stroke work data from CMR, echocardiography, or PET to obtain MEE and WMI for each modality. Repeatability was estimated as the coefficient of variation (CV) between test and retest. MEECMR, MEEEcho, and MEEPET values were 21.9 ± 2.7%, 16.4 ± 3.7%, and 23.8 ± 4.9%, respectively, P < .001. WMICMR, WMIEcho, and WMIPET values were 4.42 ± 0.90, 4.07 ± 0.63, and 4.58 ± 1.13 mmHg × mL/m2 × 106, respectively, P = .45. Repeatability for MEECMR was superior compared with MEEEcho but did not differ significantly compared with MEEPET (6.3% vs 12.9% and 9.4%, P = .04 and .25). CV values for WMICMR, WMIEcho, and WMIPET were 10.0%, 14.8%, and 12.0%, respectively, (P = .53). CONCLUSIONS: Non-invasive measurements of MEE using 11C-acetate PET are highly repeatable. A PET-only approach did not differ significantly from CMR/PET and might facilitate further clinical research due to lower costs and broader applicability.


Assuntos
Imagem Multimodal/métodos , Miocárdio/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Acetatos , Idoso , Radioisótopos de Carbono , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Oxirredução , Consumo de Oxigênio , Reprodutibilidade dos Testes
6.
J Nucl Cardiol ; 23(4): 670-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27094041

RESUMO

BACKGROUND: Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. METHODS: Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. RESULTS: LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P < .001 for all), but were underestimated by PET (P < .001 for all except ESV P = .79). PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P < .001, bias -3 ± 21%, P = .56). PET-based MEE bias was strongly associated with LV wall thickness. CONCLUSIONS: Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.


Assuntos
Acetatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Consumo de Oxigênio , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Radioisótopos de Carbono , Técnicas de Imagem Cardíaca/métodos , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Eur Heart J Cardiovasc Imaging ; 23(3): 328-337, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-34751738

RESUMO

AIMS: Myocardial external efficiency (MEE) is the ratio of cardiac work in relation with energy expenditure. We studied MEE in patients with different aetiologies and stages of heart failure (HF) to discover the role and causes of deranged MEE. In addition, we explored the impact of patient characteristics such as sex, body mass index (BMI), and age on myocardial energetics. METHODS AND RESULTS: Cardiac energetic profiles were assessed with 11C-acetate positron emission tomography (PET) and left ventricular ejection fraction (LVEF) was acquired with echocardiography. MEE was studied in 121 participants: healthy controls (n = 20); HF patients with reduced (HFrEF; n = 25) and mildly reduced (HFmrEF; n = 23) LVEF; and patients with asymptomatic (AS-asymp; n = 38) and symptomatic (AS-symp; n = 15) aortic stenosis (AS). Reduced MEE coincided with symptoms of HF irrespective of aetiology and declined in tandem with deteriorating LVEF. Patients with AS-symp and HFmrEF had reduced MEE as compared with controls (22.2 ± 4.9%, P = 0.041 and 20.0 ± 4.2%, P < 0.001 vs. 26.1 ± 5.8% in controls) and a further decline was observed in patients with HFrEF (14.7 ± 6.3%, P < 0.001). Disproportionate left ventricular hypertrophy was a major cause of reduced MEE. Female sex (P < 0.001), a lower BMI (P = 0.001), and advanced age (P = 0.03) were associated with a lower MEE. CONCLUSION: MEE was reduced in patients with HFrEF, HFmrEF, and HF due to pressure overload and MEE may therefore constitute a treatment target in HF. Patients with LVH, advanced age, female sex, and low BMI had more pronounced reduction in MEE and personalized treatment within these patient subgroups could be relevant.


Assuntos
Insuficiência Cardíaca , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Miocárdio , Prognóstico , Volume Sistólico , Função Ventricular Esquerda
9.
JACC Cardiovasc Imaging ; 13(7): 1564-1576, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31864979

RESUMO

Myocardial external efficiency is the relation of mechanical energy generated by the left (or right) ventricle to the consumed chemical energy from aerobic metabolism. Efficiency can be calculated invasively, and, more importantly, noninvasively by using positron emission tomography, providing a single parameter by which to judge the adequacy of myocardial metabolism to generated mechanical output. This parameter has been found to be impaired in heart failure of myocardial or valvular etiology, and it changes in a characteristic manner with medical or interventional cardiac therapy. The authors discuss the concept, strengths, and limitations, known applications, and future perspectives of the use of myocardial efficiency.


Assuntos
Consumo de Oxigênio , Fenômenos Fisiológicos , Humanos , Miocárdio/metabolismo , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
10.
Eur J Heart Fail ; 22(9): 1628-1637, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31863557

RESUMO

AIMS: The present study tested the hypothesis that metformin treatment may increase myocardial efficiency (stroke work/myocardial oxygen consumption) in insulin-resistant patients with heart failure and reduced ejection fraction (HFrEF) without diabetes. METHODS AND RESULTS: Thirty-six HFrEF patients (ejection fraction 37 ± 8%; median age 66 years) were randomised to metformin (n = 19) or placebo (n = 17) for 3 months in addition to standard heart failure therapy. The primary endpoint was change in myocardial efficiency expressed as the work metabolic index (WMI), assessed by 11 C-acetate positron emission tomography and transthoracic echocardiography. Compared with placebo, metformin treatment (1450 ± 550 mg/day) increased WMI [absolute mean difference, 1.0 mmHg·mL·m-2 ·106 ; 95% confidence interval (CI) 0.1 to 1.8; P = 0.03], equivalent to a 20% relative efficiency increase. Patients with above-median plasma metformin levels displayed greater WMI increase (25% vs. -4%; P = 0.02). Metformin reduced myocardial oxygen consumption (-1.6 mL O2 ·100 g-1 ·min-1 ; P = 0.014). Cardiac stroke work was preserved (-2 J; 95% CI -11 to 7; P = 0.69). Metformin reduced body weight (-2.2 kg; 95% CI -3.6 to -0.8; P = 0.003) and glycated haemoglobin levels (-0.2%; 95% CI -0.3 to 0.0; P = 0.02). Changes in resting and exercise ejection fraction, global longitudinal strain, and exercise capacity did not differ between groups. CONCLUSION: Metformin treatment in non-diabetic HFrEF patients improved myocardial efficiency by reducing myocardial oxygen consumption. Measurement of circulating metformin levels differentiated responders from non-responders. These energy-sparing effects of metformin encourage further large-scale investigations in heart failure patients without diabetes.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Metformina/uso terapêutico , Idoso , Método Duplo-Cego , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina , Volume Sistólico
11.
Eur Heart J Cardiovasc Imaging ; 20(10): 1120-1128, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30887037

RESUMO

AIMS: Left ventricular filling pressure (preload) can be assessed by pulmonary capillary wedge pressure (PCWP) during pulmonary arterial catheterization (PAC). An emerging method [pulse indexed contour cardiac output (PICCO)] can estimate preload by global end-diastolic volume (GEDV) and congestion as extravascular lung water (EVLW) content. However, no reliable quantitative non-invasive methods are available. Hence, in a porcine model of pulmonary congestion, we evaluated EVLW and GEDV by positron emission tomography (PET). The method was applied in 35 heart failure (HF) patients and 9 healthy volunteers. METHODS AND RESULTS: Eight pigs were studied. Pulmonary congestion was induced by a combination of beta-blockers, angiotensin-2 agonist and saline infusion. PAC, PICCO, computerized tomography, and 15O-H2O-PET were performed. EVLW increased from 521 ± 76 to 973 ± 325 mL (P < 0.001) and GEDV from 1068 ± 170 to 1254 ± 85 mL (P < 0.001). 15O-H2O-PET measures of EVLW increased from 566 ± 151 to 797 ± 231 mL (P < 0.001) and GEDV from 364 ± 60 to 524 ± 92 mL (P < 0.001). Both EVLW and GEDV measured with PICCO and 15O-H2O-PET correlated (r2 = 0.40, P < 0.001; r2 = 0.40, P < 0.001, respectively). EVLW correlated with Hounsfield units (HU; PICCO: r2 = 0.36, P < 0.001, PET: r2 = 0.46, P < 0.001) and GEDV with PCWP (PICCO: r2 = 0.20, P = 0.01, PET: r2 = 0.29, P = 0.002). In human subjects, measurements were indexed (I) for body surface area. Neither EVLWI nor HU differed between chronic stable HF patients and healthy volunteers (P = 0.11, P = 0.29) whereas GEDVI was increased in HF patients (336 ± 66 mL/m2 vs. 276 ± 44 mL/m2, P = 0.01). CONCLUSION: The present study demonstrates that 15O-H2O-PET can assess pulmonary congestion and preload quantitatively. Hence, prognostic information from 15O-H2O-PET examinations should be evaluated in clinical trials.


Assuntos
Água Extravascular Pulmonar/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Idoso , Animais , Débito Cardíaco , Estudos de Casos e Controles , Modelos Animais de Doenças , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Circulação Pulmonar , Pressão Propulsora Pulmonar , Suínos , Tomografia Computadorizada por Raios X
12.
EJNMMI Phys ; 4(1): 26, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29138942

RESUMO

BACKGROUND: Quantitative measurement of myocardial blood flow (MBF) is of increasing interest in the clinical assessment of patients with suspected coronary artery disease (CAD). 15O-water positron emission tomography (PET) is considered the gold standard for non-invasive MBF measurements. However, calculation of left ventricular (LV) volumes and ejection fraction (EF) is not possible from standard 15O-water uptake images. The purpose of the present work was to investigate the possibility of calculating LV volumes and LVEF from cardiac-gated parametric blood volume (V B) 15O-water images and from first pass (FP) images. Sixteen patients with mitral or aortic regurgitation underwent an eight-gate dynamic cardiac-gated 15O-water PET/CT scan and cardiac MRI. V B and FP images were generated for each gate. Calculations of end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV) and LVEF were performed with automatic segmentation of V B and FP images, using commercially available software. LV volumes and LVEF were calculated with surface-, count-, and volume-based methods, and the results were compared with gold standard MRI. RESULTS: Using V B images, high correlations between PET and MRI ESV (r = 0.89, p < 0.001), EDV (r = 0.85, p < 0.001), SV (r = 0.74, p = 0.006) and LVEF (r = 0.72, p = 0.008) were found for the volume-based method. Correlations for FP images were slightly, but not significantly, lower than those for V B images when compared to MRI. Surface- and count-based methods showed no significant difference compared with the volume-based correlations with MRI. The volume-based method showed the best agreement with MRI with no significant difference on average for EDV and LVEF but with an overestimation of values for ESV (14%, p = 0.005) and SV (18%, p = 0.004) when using V B images. Using FP images, none of the parameters showed a significant difference from MRI. Inter-operator repeatability was excellent for all parameters (ICC > 0.86, p < 0.001). CONCLUSION: Calculation of LV volumes and LVEF from dynamic 15O-water PET is feasible and shows good correlation with MRI. However, the analysis method is laborious, and future work is needed for more automation to make the method more easily applicable in a clinical setting.

13.
J Am Heart Assoc ; 6(3)2017 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-28242634

RESUMO

BACKGROUND: High levels of ketone bodies are associated with improved survival as observed with regular exercise, caloric restriction, and-most recently-treatment with sodium-glucose linked transporter 2 inhibitor antidiabetic drugs. In heart failure, indices of ketone body metabolism are upregulated, which may improve energy efficiency and increase blood flow in skeletal muscle and the kidneys. Nevertheless, it is uncertain how ketone bodies affect myocardial glucose uptake and blood flow in humans. Our study was therefore designed to test whether ketone body administration in humans reduces myocardial glucose uptake (MGU) and increases myocardial blood flow. METHODS AND RESULTS: Eight healthy subjects, median aged 60 were randomly studied twice: (1) During 390 minutes infusion of Na-3-hydroxybutyrate (KETONE) or (2) during 390 minutes infusion of saline (SALINE), together with a concomitant low-dose hyperinsulinemic-euglycemic clamp to inhibit endogenous ketogenesis. Myocardial blood flow was measured by 15O-H2O positron emission tomography/computed tomography, myocardial fatty acid metabolism by 11C-palmitate positron emission tomography/computed tomography and MGU by 18F-fluorodeoxyglucose positron emission tomography/computed tomography. Similar euglycemia, hyperinsulinemia, and suppressed free fatty acids levels were recorded on both study days; Na-3-hydroxybutyrate infusion increased circulating Na-3-hydroxybutyrate levels from zero to 3.8±0.5 mmol/L. MGU was halved by hyperketonemia (MGU [nmol/g per minute]: 304±97 [SALINE] versus 156±62 [KETONE], P<0.01), whereas no effects were observed on palmitate uptake oxidation or esterification. Hyperketonemia increased heart rate by ≈25% and myocardial blood flow by 75%. CONCLUSIONS: Ketone bodies displace MGU and increase myocardial blood flow in healthy humans; these novel observations suggest that ketone bodies are important cardiac fuels and vasodilators, which may have therapeutic potentials.


Assuntos
Ácido 3-Hidroxibutírico/farmacologia , Circulação Coronária/efeitos dos fármacos , Glucose/metabolismo , Frequência Cardíaca/efeitos dos fármacos , Coração/efeitos dos fármacos , Corpos Cetônicos/farmacologia , Miocárdio/metabolismo , Idoso , Radioisótopos de Carbono , Feminino , Fluordesoxiglucose F18 , Técnica Clamp de Glucose , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , Palmitatos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Compostos Radiofarmacêuticos , Água
14.
J Am Heart Assoc ; 6(2)2017 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-28167498

RESUMO

BACKGROUND: Myocardial oxygen consumption (MVO2) and its coupling to contractile work are fundamentals of cardiac function and may be involved causally in the transition from compensated left ventricular hypertrophy to failure. Nevertheless, these processes have not been studied previously in patients with aortic valve stenosis (AS). METHODS AND RESULTS: Participants underwent 11C-acetate positron emission tomography, cardiovascular magnetic resonance, and echocardiography to measure MVO2 and myocardial external efficiency (MEE) defined as the ratio of left ventricular stroke work and the energy equivalent of MVO2. We studied 10 healthy controls (group A), 37 asymptomatic AS patients with left ventricular ejection fraction ≥50% (group B), 12 symptomatic AS patients with left ventricular ejection fraction ≥50% (group C), and 9 symptomatic AS patients with left ventricular ejection fraction <50% (group D). MVO2 did not differ among groups A, B, C, and D (0.105±0.02, 0.117±0.024, 0.129±0.032, and 0.104±0.026 mL/min per gram, respectively; P=0.07), whereas MEE was reduced in group D (21.0±1.6%, 22.3±3.3%, 22.1±4.2%, and 17.3±4.7%, respectively; P<0.05). Similarly, patients with global longitudinal strain greater than -12% and paradoxical low-flow, low-gradient AS had impaired MEE (P<0.05 versus controls). The ability to discriminate between symptomatic and asymptomatic patients was superior for global longitudinal strain compared with MVO2 and MEE (area under the curve 0.98, 0.48, and 0.61, respectively; P<0.05). CONCLUSIONS: AS patients display a persistent ability to maintain normal MVO2 and MEE (ie, the ability to convert energy into stroke work); however, patients with left ventricular ejection fraction <50%; global longitudinal strain greater than -12%; or paradoxical low-flow, low-gradient AS demonstrate reduced MEE. These findings suggest that mitochondrial uncoupling contributes to the dismal prognosis in patients with reduced contractile function or paradoxical low-flow, low-gradient AS.


Assuntos
Estenose da Valva Aórtica/metabolismo , Insuficiência Cardíaca/metabolismo , Ventrículos do Coração/fisiopatologia , Miocárdio/metabolismo , Consumo de Oxigênio , Volume Sistólico/fisiologia , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Progressão da Doença , Ecocardiografia , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Prognóstico , Índice de Gravidade de Doença , Função Ventricular Esquerda
15.
Circ Cardiovasc Imaging ; 10(10)2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28956773

RESUMO

BACKGROUND: Currently, no pharmacological treatment can modify the natural history of aortic valve stenosis (AS). This underlines the critical need to explore novel treatment strategies, which could postpone or prevent the need for aortic valve replacement in patients with asymptomatic AS. The objectives of this study were to investigate whether metoprolol reduce the hemodynamic and metabolic burden imposed by AS. METHODS AND RESULTS: In a double-blinded design, 40 patients with moderate-severe asymptomatic AS (aortic valve area, 0.5±0.1 cm2/m2; peak gradient, 53±19 mm Hg) were randomized to placebo or metoprolol treatment for 22 weeks. Patients were evaluated by echocardiography, cardiovascular magnetic resonance, and 11C-acetate positron emission tomography. Compared with placebo, metoprolol (100±53 mg/d) decreased heart rate; mean difference (95% confidence interval) -8 minute-1 (-13, -3; P=0.003) and increased ejection time 26 ms (2, 50; P=0.03). Furthermore, metoprolol reduced aortic valve peak -7 mm Hg (-13, 0; P=0.05) and mean -4 mm Hg (-7, -1; P=0.03) gradients, without affecting stroke volume 3 mL/m2 (-2, 8; P=0.16). Valvuloarterial impedance (ie, global afterload) and myocardial oxygen consumption were reduced by -11% and -12% (P=0.03 and 0.01), respectively; and decreased heart rate correlated with lower valvuloarterial impedance, myocardial oxygen consumption, and improved myocardial efficiency defined as stroke work/myocardial oxygen consumption (r=0.63-0.65; all P<0.01). There were 2 adverse cardiovascular events in the metoprolol group and none in the placebo group. CONCLUSIONS: In patients with asymptomatic AS, metoprolol increases systolic ejection time and reduces aortic valve gradients, global afterload, and myocardial oxygen requirements. Thus, metoprolol displays favorable hemodynamic and metabolic effects and could improve outcome in patients with asymptomatic AS. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT02076711.


Assuntos
Antagonistas de Receptores Adrenérgicos beta 1/uso terapêutico , Estenose da Valva Aórtica/tratamento farmacológico , Valva Aórtica/efeitos dos fármacos , Metabolismo Energético/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Metoprolol/uso terapêutico , Antagonistas de Receptores Adrenérgicos beta 1/efeitos adversos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/metabolismo , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/metabolismo , Estenose da Valva Aórtica/fisiopatologia , Doenças Assintomáticas , Dinamarca , Método Duplo-Cego , Ecocardiografia Doppler , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Metoprolol/efeitos adversos , Pessoa de Meia-Idade , Consumo de Oxigênio/efeitos dos fármacos , Tomografia por Emissão de Pósitrons , Fatores de Tempo , Resultado do Tratamento
16.
J Nucl Med ; 57(9): 1382-7, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27127219

RESUMO

UNLABELLED: Dynamic cardiac PET is used to quantify molecular processes in vivo. However, measurements of left ventricular (LV) mass and volume require electrocardiogram-gated PET data. The aim of this study was to explore the feasibility of measuring LV geometry using nongated dynamic cardiac PET. METHODS: Thirty-five patients with aortic-valve stenosis and 10 healthy controls underwent a 27-min (11)C-acetate PET/CT scan and cardiac MRI (CMR). The controls were scanned twice to assess repeatability. Parametric images of uptake rate K1 and the blood pool were generated from nongated dynamic data. Using software-based structure recognition, the LV wall was automatically segmented from K1 images to derive functional assessments of LV mass (mLV) and wall thickness. End-systolic and end-diastolic volumes were calculated using blood pool images and applied to obtain stroke volume and LV ejection fraction (LVEF). PET measurements were compared with CMR. RESULTS: High, linear correlations were found for LV mass (r = 0.95), end-systolic volume (r = 0.93), and end-diastolic volume (r = 0.90), and slightly lower correlations were found for stroke volume (r = 0.74), LVEF (r = 0.81), and thickness (r = 0.78). Bland-Altman analyses showed significant differences for mLV and thickness only and an overestimation for LVEF at lower values. Intra- and interobserver correlations were greater than 0.95 for all PET measurements. PET repeatability accuracy in the controls was comparable to CMR. CONCLUSION: LV mass and volume are accurately and automatically generated from dynamic (11)C-acetate PET without electrocardiogram gating. This method can be incorporated in a standard routine without any additional workload and can, in theory, be extended to other PET tracers.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Reconhecimento Automatizado de Padrão/métodos , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Estenose da Valva Aórtica/complicações , Técnicas de Imagem de Sincronização Cardíaca , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
17.
EJNMMI Phys ; 2(1): 25, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26501826

RESUMO

BACKGROUND: The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. METHODS: 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR). RESULTS: FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p < 0.001 for all). FSV based on (11)C-acetate and (15)O-water correlated highly (r = 0.99, slope = 1.03) with no significant difference between FSV estimates (p = 0.14). CONCLUSIONS: FSV can be obtained automatically using dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA