1.
J Cardiovasc Electrophysiol ; 34(1): 142-146, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36349715

RESUMO

OBJECTIVE: This study aimed to report the real-world atrial fibrillation (AF) diagnostic yield of the implantable cardiac monitor (ICM) in patients with stroke or transient ischemic attack (TIA), and compare it to patients with an ICM for unexplained syncope. METHODS: We used patient data from device clinics across the United States of America with ICM remote monitoring via PaceMate™, implanted for stroke or TIA, and unexplained syncope. Patients with known AF or atrial flutter were excluded. The outcome was AF lasting ≥2 min, adjudicated by International Board of Heart Rhythm Examiners certified cardiac device specialists. RESULTS: We included a total of 2469 patients, 51.1% with stroke or TIA (mean age: 69.7 [SD: 12.2] years, 41.1% female) and 48.9% with syncope (mean age: 67.0 [SD: 17.1] years, 59.4% female). The cumulative AF detection rate in patients with stroke or TIA was 5.5%, 8.9%, and 14.0% at 12, 24, and 36 months, respectively. The median episode duration was 73 (interquartile range: 10-456) min, ranging from 2 min to 40.9 days, with 52.3%, 28.6%, and 4.4% of episodes lasting at least 1, 6, and 24 h, respectively. AF detection was increased by age (adjusted hazard ratio [for every 1-year increase]: 1.024, 95% confidence interval: 1.008-1.040; p = .003), but was not influenced by sex (p = .089). For comparison, the cumulative detection rate at 12, 24, and 36 months were, respectively, 2.4%, 5.2%, and 7.4% in patients with syncope. CONCLUSION: Patients with stroke or TIA have a higher rate of AF detection. However, this real-world study shows significantly lower AF detection rates than what has been previously reported.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/diagnóstico , Eletrocardiografia Ambulatorial , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Síncope/diagnóstico , Síncope/etiologia
2.
Eur Heart J ; 42(5): 520-528, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33321517

RESUMO

AIMS: Our objective was to determine the ventricular arrhythmia burden in implantable cardioverter-defibrillator (ICD) patients during COVID-19. METHODS AND RESULTS: In this multicentre, observational, cohort study over a 100-day period during the COVID-19 pandemic in the USA, we assessed ventricular arrhythmias in ICD patients from 20 centres in 13 states, via remote monitoring. Comparison was via a 100-day control period (late 2019) and seasonal control period (early 2019). The primary outcome was the impact of COVID-19 on ventricular arrhythmia burden. The secondary outcome was correlation with COVID-19 incidence. During the COVID-19 period, 5963 ICD patients underwent remote monitoring, with 16 942 episodes of treated ventricular arrhythmias (2.8 events per 100 patient-days). Ventricular arrhythmia burden progressively declined during COVID-19 (P < 0.001). The proportion of patients with ventricular arrhythmias amongst the high COVID-19 incidence states was significantly reduced compared with those in low incidence states [odds ratio 0.61, 95% confidence interval (CI) 0.54-0.69, P < 0.001]. Comparing patients remotely monitored during both COVID-19 and control periods (n = 2458), significantly fewer ventricular arrhythmias occurred during COVID-19 [incident rate ratio (IRR) 0.68, 95% CI 0.58-0.79, P < 0.001]. This difference persisted when comparing the 1719 patients monitored during both the COVID-19 and seasonal control periods (IRR 0.69, 95% CI 0.56-0.85, P < 0.001). CONCLUSIONS: During COVID-19, there was a 32% reduction in ventricular arrhythmias needing device therapies, coinciding with measures of social isolation. There was a 39% reduction in the proportion of patients with ventricular arrhythmias in states with higher COVID-19 incidence. These findings highlight the potential role of real-life stressors in ventricular arrhythmia burden in individuals with ICDs. TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry; URL: https://www.anzctr.org.au/; Unique Identifier: ACTRN12620000641998.


Assuntos
Arritmias Cardíacas/epidemiologia , COVID-19 , Desfibriladores Implantáveis , Fibrilação Ventricular/epidemiologia , Adulto , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , COVID-19/epidemiologia , COVID-19/prevenção & controle , Efeitos Psicossociais da Doença , Feminino , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Pandemias , Distanciamento Físico , Fatores de Proteção , Sistema de Registros , Fatores de Risco , Estresse Psicológico , Telemedicina , Estados Unidos/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia
3.
Europace ; 23(9): 1493-1501, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-34077513

RESUMO

AIMS: The aim of this study is to determine the association between the coronavirus disease 2019 (COVID-19) pandemic and atrial fibrillation (AF) occurrence in individuals with cardiac implantable electronic devices (CIEDs). METHOD AND RESULTS: Multi-centre, observational, cohort study over a 100-day period during the COVID-19 pandemic (COVID-19) in the USA. Remote monitoring was used to assess AF episodes in patients with a CIED (pacemaker or defibrillator; 20 centres, 13 states). For comparison, the identical 100-day period in 2019 was used (Control). The primary outcomes were the AF burden during the COVID-19 pandemic, and the association of the pandemic with AF occurrence, as compared with 1 year prior. The secondary outcome was the association of AF occurrence with per-state COVID-19 prevalence. During COVID-19, 10 346 CIEDs with an atrial lead were monitored. There were 16 570 AF episodes of ≥6 min transmitted (16 events per 1000 patient days) with a significant increase in proportion of patients with AF episodes in high COVID-19 prevalence states compared with low prevalence states [odds ratio 1.34, 95% confidence interval (CI) 1.21-1.48, P < 0.001]. There were significantly more AF episodes during COVID-19 compared with Control [incident rate ratio (IRR) 1.33, 95% CI 1.25-1.40, P < 0.001]. This relationship persisted for AF episodes ≥1 h (IRR 1.65, 95% CI 1.53-1.79, P < 0.001) and ≥6 h (IRR 1.54, 95% CI 1.38-1.73, P < 0.001). CONCLUSION: During the first 100 days of COVID-19, a 33% increase in AF episodes occurred with a 34% increase in the proportion of patients with AF episodes observed in states with higher COVID-19 prevalence. These findings suggest a possible association between pandemic-associated social disruptions and AF in patients with CIEDs. CLINICAL TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry: ACTRN12620000692932.


Assuntos
Fibrilação Atrial , COVID-19 , Desfibriladores Implantáveis , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Austrália , Estudos de Coortes , Humanos , Pandemias , SARS-CoV-2
4.
Heart Rhythm O2 ; 4(2): 90-96, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36873319

RESUMO

Background: The volume of remote monitoring (RM) data generates a significant workload and is generally dealt with by clinic staff during standard office hours, potentially delaying clinical action. Objective: The purpose of this study was to determine the clinical efficiency and workflow of implementing intensive RM (IRM) in patients with cardiac implantable electronic device (CIED) when compared with standard RM (SRM). Methods: From a cohort of >1500 remotely monitored devices, 70 patients were randomly selected to undergo IRM. For comparison, an equal number of matched patients were prospectively selected for SRM. Intensive follow-up occurred via automated vendor-neutral software with rapid alert processing by International Board of Heart Rhythm Examiners-certified device specialists. Standard follow-up was conducted by clinic staff during office hours via individual device vendor interfaces. Alerts were categorized on the basis of the level of acuity as actionable (red [high], yellow [moderate]), or green [not requiring action]). Results: Over 9 months of follow-up, 922 remote transmissions were received; 339 (36.8%) were coded as actionable alerts (118 in IRM and 221 in SRM; P < .001). The median time from initial transmission to review was 6 hours (interquartile range [IQR] 1.8-16.8 hours) in the IRM group compared with 10.5 hours (IQR 6.0-32.2 hours) in the SRM group (P < .001). The median time from transmission to review of actionable alerts in the IRM group was 5.1 hours (IQR 2.3-8.9 hours) compared with 9.1 hours (IQR 6.7-32.5 hours) in the SRM group (P < .001). Conclusion: Intensive and managed RM results in a significant reduction in time to review alerts and number of actionable alerts. Monitoring with enhanced alert adjudication is needed to facilitate device clinic efficiency and optimize patient care. Study Registration: ACTRN12621001275853.

5.
J Interv Card Electrophysiol ; 66(7): 1659-1668, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36735111

RESUMO

BACKGROUND: Remote monitoring (RM) can facilitate early detection of subclinical and symptomatic atrial fibrillation (AF), providing an opportunity to evaluate the need for stroke prevention therapies. We aimed to characterize the burden of RM AF alerts and its impact on anticoagulation of patients with device-detected AF. METHODS: Consecutive patients with a cardiac implantable electronic device, at least one AF episode, undergoing RM were included and assigned an estimated minimum CHA2DS2-VASc score based on age and device type. RM was provided via automated software system, providing rapid alert processing by device specialists and systematic, recurrent prompts for anticoagulation. RESULTS: From 7651 individual, 389,188 AF episodes were identified, 3120 (40.8%) permanent pacemakers, 2260 (29.5%) implantable loop recorders (ILRs), 987 (12.9%) implantable cardioverter defibrillators, 968 (12.7%) cardiac resynchronization therapy (CRT) defibrillators, and 316 (4.1%) CRT pacemakers. ILRs transmitted 48.8% of all AF episodes. At twelve-months, 3404 (44.5%) AF < 6 min, 1367 (17.9%) 6 min-6 h, 1206 (15.8%) 6-24 h, and 1674 (21.9%) ≥ 24 h. A minimum CHA2DS2-VASc score of 2 was assigned to 1704 (63.1%) of the patients with an AF episode of ≥ 6 h, 531 (31.2%) who were not anticoagulated at 12-months, and 1031 (61.6%) patients with an AF episode duration of ≥ 24 h, 290 (28.1%) were not anticoagulated. CONCLUSIONS: Despite being intensively managed via RM software system incorporating cues for anticoagulation, a substantial proportion of patients with increased stroke risk remained unanticoagulated after a device-detected AF episode of significant duration. These data highlight the need for improved clinical response pathways and an integrated care approach to RM. TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry: ACTRN12620001232921.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Anticoagulantes , Fibrilação Atrial/diagnóstico , Austrália , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS