Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Phys ; 36(6): 2107-17, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19610300

RESUMO

Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasimonochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten Kalpha emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor increases from 2.2 to 2.4 by using quasi-monochromatic instead of polychromatic radiation. An additional increase in the radiation dose by a factor of 1.4 due to the focusing characteristic of the x-ray optical module was calculated. Photoelectric-enhanced radiation therapy based on a clinical CT unit combined with an x-ray optical module is a novel therapy option in radiation oncology. The optimized quasi-monochromatic radiation is strongly focused and ensures high photoelectric dose enhancement for iodine.


Assuntos
Radioterapia Conformacional/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Anal Bioanal Chem ; 393(2): 623-34, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18998118

RESUMO

Multilayered samples consisting of Al, Co and Ni nanolayers were produced by MBE and characterized nondestructively by means of SRXRF, mu-XRF, WDXRF, RBS, XRR, and destructively with SIMS. The main aims were to identify the elements, to determine their purity and their sequence, and also to examine the roughness, density, homogeneity and thickness of each layer. Most of these important properties could be determined by XRF methods, e.g., on commercial devices. For the thickness, it was found that all of the results obtained via XRR, RBS, SIMS and various XRF methods (SRXRF, mu-XRF, WDXRF) agreed with each other within the limits of uncertainty, and a constant deviation from the presets used in the MBE production method was observed. Some serious preliminary discrepancies in the results from the XRF methods were examined, but all deviations could be explained by introducing various corrections into the evaluation methods and/or redetermining some fundamental parameters.


Assuntos
Alumínio/análise , Cobalto/análise , Cobre/análise , Nanotecnologia , Níquel/análise , Nanoestruturas/análise , Tamanho da Partícula , Sensibilidade e Especificidade , Espectrometria por Raios X , Propriedades de Superfície
3.
Eur J Radiol ; 68(3 Suppl): S63-8, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18586430

RESUMO

INTRODUCTION: Computed tomography (CT) is a widespread and highly precise technique working in the energy range around 50-100 keV. For radiotherapy, however, the MeV energy range enables a better dose distribution. This gap between diagnosis and therapy can be overcome by the use of a modified CT machine in combination with heavy elements targeted to the tumour and used as photoelectric radiation enhancer. MATERIALS AND METHODS: The experimental setup consists of an X-ray optical module mounted at the exit of the X-ray tube of a clinical CT. The module converts the standard fan-shaped beam into a high intensity, monochromatized and focused beam. The radiation was characterized using an energy-dispersive detection system calibrated by synchrotron radiation and gel dosimetry. The photoelectric radiation enhancement for different elements was calculated and experimentally verified. RESULTS: The X-ray optical module filters selectively the energy of the tungsten K alpha-emission line (59.3 keV) with a full width at half maximum (FWHM) of 5 keV and focused the radiation onto a focal spot which coincides with the isocentre of the gantry. This results in a steep dose gradient at the centre of rotation qualified for locoregional radiation therapy. The photon energy of the quasi-monochromatic radiation agrees with the energy range of maximal photoelectric dose enhancement for gadolinium and iodine. CONCLUSION: An additional X-ray optical module optimized for targeted therapy and photoelectric dose enhancement allows the combination of diagnosis and radiotherapy on a clinical CT.


Assuntos
Desenho Assistido por Computador , Radioterapia de Alta Energia/instrumentação , Radioterapia de Alta Energia/métodos , Tomografia por Raios X/instrumentação , Tomografia por Raios X/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA