Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Environ Sci (China) ; 24(9): 1559-68, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23520862

RESUMO

The present work covers the preparation of carbon-based nanosorbents by ethylene decomposition on stainless steel mesh without the use of external catalyst for the treatment of water containing nickel ions (Ni2+). The reaction temperature was varied from 650 to 850 degrees C, while reaction time and ethylene to nitrogen flow ratio were maintained at 30 min and 1:1 cm3/min, respectively. Results show that nanosorbents synthesised at a reaction temperature of 650 degrees C had the smallest average diameter (75 nm), largest BET surface area (68.95 m2/g) and least amount of impurity (0.98 wt.% Fe). A series of batch-sorption tests were performed to evaluate the effects of initial pH, initial metal concentration and contact time on Ni2+ removal by the nanosorbents. The equilibrium data fitted well to Freundlich isotherm. The kinetic data were best correlated to a pseudo second-order model indicating that the process was of chemisorption type. Further analysis by the Boyd kinetic model revealed that boundary layer diffusion was the controlling step. This primary study suggests that the prepared material with Freundlich constants compared well with those in the literature, is a promising sorbent for the sequestration of Ni2+ in aqueous solutions.


Assuntos
Etilenos/química , Nanotubos de Carbono/química , Níquel/química , Água/química , Aço Inoxidável
2.
Phys Rev E Stat Nonlin Soft Matter Phys ; 77(5 Pt 1): 050801, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18643014

RESUMO

Entangled polymer melts exhibit a variety of flow instabilities that limit production rates in industrial applications. We present both experimental and computational findings, using flow of monodisperse linear polystyrenes in a contraction-expansion geometry, which illustrate the formation and development of one such flow instability. This viscoelastic disturbance is observed at the slit outlet and subsequently produces large-scale fluid motions upstream. A numerical linear stability study using the molecular structure based Rolie-Poly model confirms the instability and identifies important parameters within the model, which gives physical insight into the underlying mechanism. Chain stretch was found to play a critical role in the instability mechanism, which partially explains the effectiveness of introducing a low-molecular weight tail into a polymer blend to increase its processability.

3.
Am J Kidney Dis ; 38(5): 948-55, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11684546

RESUMO

Dialysis efficacy indexed by Kt/V can generally be augmented by increasing the dialyzer blood flow rate. However, increasing the dialyzer blood flow rate may lead to vascular-access recirculation (AR) in patients with a compromised vascular-access flow rate. This can have an attenuating effect on dialysis efficacy. The aim of the present study is to investigate the effect of dialyzer blood flow rates of 200, 300, and 400 mL/min on AR and Kt/V in 8 patients with low (<600 mL/min) and 13 patients with normal (>600 mL/min) vascular-access flow rates. AR and vascular-access flow rate were determined using an ultrasound saline dilution technique, and session-delivered Kt/V was computed using an on-line dialysate urea monitor. AR was minor and only observed in 4 patients in the low vascular-access flow rate group (0.9% +/- 0.6%) at dialyzer blood flow rates of 200 mL/min (1 patient), 300 mL/min (2 patients), and 400 mL/min (3 patients) and 4 patients in the normal vascular-access flow rate group (1.2% +/- 1.1%) at dialyzer blood flow rates of 200 mL/min (3 patients) and 300 mL/min (1 patient). Kt/V increased with increasing dialyzer blood flow rates in both groups, and in individual cases, there was no decrease in Kt/V at greater dialyzer blood flow rates in either group. Also in those patients with minor AR, Kt/V increased at greater dialyzer blood flow rates, except in 1 patient in the low-flow group, in whom Kt/V remained unchanged at a change in dialyzer blood flow rate from 300 to 400 mL/min, whereas AR increased. From this study, it is concluded that even in patients with low access flow, increasing dialyzer blood flow rate in general leads to an increase in delivered Kt/V regardless of vascular access flow rate.


Assuntos
Circulação Sanguínea , Falência Renal Crônica/fisiopatologia , Diálise Renal/métodos , Idoso , Derivação Arteriovenosa Cirúrgica , Velocidade do Fluxo Sanguíneo , Prótese Vascular , Feminino , Humanos , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade
4.
Med Phys ; 21(3): 453-61, 1994 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8208221

RESUMO

An automated digital image subtraction technique for temporally sequential chest images has been developed in order to aid radiologists in the detection of interval changes. A number of small regions of interest (ROIs) are selected automatically in the lung areas of two temporally sequential chest images. A local matching, based on a cross-correlation method, is performed on each pair of corresponding ROIs in order to determine shift values for the coordinates of two images. A proper warping of x,y coordinates is obtained by fitting two-dimensional polynomials to the distributions of shift values. One of the images is warped and then subtracted from the other. Forty six pairs of chest images (42 with interval changes and 4 without interval change) were processed using this method. The subtraction images were able to enhance various important interval changes, such as differences in the size of tumor masses, changes in heart size, and changes in pulmonary infiltrates or pleural effusions. Approximately 70% of the pairs showed reasonably good registration.


Assuntos
Intensificação de Imagem Radiográfica , Radiografia Torácica/métodos , Humanos , Técnica de Subtração , Tecnologia Radiológica , Fatores de Tempo
8.
9.
AJNR Am J Neuroradiol ; 29(9): 1684-91, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18599575

RESUMO

BACKGROUND AND PURPOSE: The higher relaxivity of gadobenate dimeglumine compared with gadodiamide is potentially advantageous for contrast-enhanced brain MR imaging. This study intraindividually compared 0.1-mmol/kg doses of these agents for qualitative and quantitative lesion enhancement. MATERIALS AND METHODS: Adult patients with suggested or known brain lesions underwent 2 identical MR imaging examinations at 1.5T, one with gadobenate dimeglumine and the other with gadodiamide. The agents were administered in randomized order separated by 3-14 days. Imaging sequences and postinjection acquisition timing were identical for the 2 examinations. Three blinded readers evaluated images qualitatively for diagnostic information (lesion extent, delineation, morphology, enhancement, and global preference) and quantitatively for contrast-to-noise ratio (CNR). RESULTS: One hundred thirteen of 138 enrolled patients successfully underwent both examinations. Final diagnoses were intra-axial tumor, metastasis, extra-axial tumor, or other (47, 27, 18, and 21 subjects, respectively). Readers 1, 2, and 3 demonstrated global preference for gadobenate dimeglumine in 63 (55.8%), 77 (68.1%), and 73 (64.6%) patients, respectively, compared with 3, 2, and 3 patients for gadodiamide (P < .0001, all readers). Highly significant (P < .0001, all readers) preference for gadobenate dimeglumine was demonstrated for all qualitative end points and for CNR (increases of 23.3%-34.7% and 42.4%-48.9% [spin-echo and gradient-refocused echo sequences, respectively] for gadobenate dimeglumine compared with gadodiamide). Inter-reader agreement was good for all evaluations (kappa = 0.47-0.69). Significant preference for gadobenate dimeglumine was demonstrated for all lesion subgroup analyses. CONCLUSION: Significantly greater diagnostic information and lesion enhancement are achieved on brain MR imaging with 0.1-mmol/kg gadobenate dimeglumine compared with gadodiamide at an equivalent dose.


Assuntos
Neoplasias Encefálicas/diagnóstico , Meios de Contraste , Gadolínio DTPA , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo/patologia , Neoplasias Encefálicas/secundário , Estudos Cross-Over , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sensibilidade e Especificidade , Adulto Jovem
10.
Pediatr Radiol ; 19(3): 206-7, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2497433

RESUMO

An attempt at placement of a left femoral vein hyperalimentation catheter resulted in entrance of the catheter into the spinal canal. Catheter location was documented by injections of nonionic contrast material into the catheter without neurologic sequellae.


Assuntos
Cateterismo Venoso Central/efeitos adversos , Nutrição Parenteral Total/instrumentação , Canal Medular , Humanos , Lactente , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA