1.
J Microsc ; 281(2): 138-156, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32737879

RESUMO

The introduction of cryo-techniques to the focused ion-beam scanning electron microscope (FIB-SEM) has brought new opportunities to study frozen, hydrated samples from the field of Life Sciences. Cryo-techniques have long been employed in electron microscopy. Thin electron transparent sections are produced by cryo-ultramicrotomy for observation in a cryo-transmission electron microscope (TEM). Cryo-TEM is presently reaching the imaging of macromolecular structures. In parallel, cryo-fractured surfaces from bulk materials have been investigated by cryo-SEM. Both cryo-TEM and cryo-SEM have provided a wealth of information, despite being 2D techniques. Cryo-TEM tomography does provide 3D information, but the thickness of the volume has a maximum of 200-300 nm, which limits the 3D information within the context of specific structures. FIB-milling enables imaging additional planes by creating cross-sections (e.g. cross-sectioning or site-specific X-sectioning) perpendicular to the cryo-fracture surface, thus adding a third imaging dimension to the cryo-SEM. This paper discusses how to produce suitable cryo-FIB-SEM cross-section results from frozen, hydrated Life Science samples with emphasis on 'common knowledge' and reoccurring observations. LAY DESCRIPTION: Life Sciences studies life down to the smallest details. Visualising the smallest details requires electron microscopy, which utilises high-vacuum chambers. One method to maintain the integrity of Life Sciences samples under vacuum conditions is freezing. Frozen samples can remain in a suspended state. As a result, research can be carried out without having to change the chemistry or internal physical structure of the samples. Two types of electron microscopes equipped with cryo-sample handling facilities are used to investigate samples: The scanning electron microscope (SEM) which investigates surfaces and the transmission electron microscope (TEM) which investigates thin electron transparent sections (called lamellae). A third method of investigation combines a SEM with a focused ion beam (FIB) to form a cryo-FIB-SEM, which is the basis of this paper. The electron beam images the cryo-sample surface while the ion beam mills into the surface to expose the interior of the sample. The latter is called cross-sectioning and the result provides a way of investigating the 3rd dimension of the sample. This paper looks at the making of cross-sections in this manner originating from knowledge and experience gained with this technique over many years. This information is meant for newcomers, and experienced researchers in cryo-microscopy alike.


Assuntos
Disciplinas das Ciências Biológicas , Tomografia com Microscopia Eletrônica , Microscopia Crioeletrônica , Microscopia Eletrônica , Microtomia
2.
J Microsc ; 281(2): 125-137, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32691851

RESUMO

The desire to study macromolecular complexes within their cellular context requires the ability to produce thin samples suitable for cryo-TEM (cryo-transmission electron microscope) investigations. In this paper, we discuss two similar approaches, which were developed independently in Utrecht (the Netherlands) and Albany (USA). The methods are particularly suitable for both tissue samples and cell suspensions prepared by a high-pressure freezer (HPF). The workflows are explained with particular attention to potential pitfalls, while underlying principles are highlighted ('why to do so'). Although both workflows function with a high success rate, full execution requires considerable experience and remains demanding. In addition, throughput is low. We hope to encourage other research groups worldwide to take on the challenge of improving the HPF- cryo-FIB-SEM - cryo-TEM workflow. We discuss a number of suggestions to this end. LAY DESCRIPTION: Life is ultimately dictated by the interaction of molecules in our bodies. Highly complex equipment is being used and further developed to study these interactions. The present paper describes methods to prepare small, very thin lamellae (area of 5×5 µm2 , thickness 50-300 nm) of a cell to be studied in a cryo-transmission electron microscope (cryo-TEM). Special care must be taken to preserve the natural state of molecules in their natural environment. In the case of cryo-TEM, the samples must be frozen and kept frozen to be compatible with the vacuum conditions in the microscope. The frozen condition imposes technical challenges which are addressed. Two approaches to obtain the thin lamellae are described. Both make use of a focused ion beam (FIB) microscope. The FIB allows removal of material with nanometre precision by focusing a beam of ionised atoms (gallium ions) onto the sample. Careful control of the FIB allows cutting out of the required thin lamellae. In both strategies, the thin lamellae remain attached to the original sample, and the ensemble of sample with section and sample holder is transported from the FIB microscope to the TEM while being kept frozen.


Assuntos
Gálio/química , Íons/química , Microscopia Eletrônica de Transmissão , Microscopia Crioeletrônica , Congelamento , Fluxo de Trabalho
3.
J Microsc ; 242(3): 295-310, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21155992

RESUMO

Naturally deformed ice contains subgrains with characteristic geometries that have recently been identified in etched surfaces using high-resolution light microscopy (LM). The probable slip systems responsible for these subgrain boundary types can be determined using electron backscattered diffraction (EBSD), providing the etch features imaged with reflected LM can be retained during EBSD data acquisition in a scanning electron microscope (SEM). Retention of the etch features requires that the ice surface is stable. Depending on the pressure and temperature, sublimation of ice can occur. The equilibrium temperature for a low pressure SEM operating at 1 × 10(-6) hPa is about -112°C and operating at higher temperatures causes sublimation. Although charging of uncoated ice samples is reduced by sublimation, important information contained in the etch features are removed as the surface sublimes. We developed a method for collecting EBSD data on stable ice surfaces in a low pressure SEM. We found that operating at temperatures of <-112°C reduced sublimation so that the original etch surface features were retained. Charging, which occurred at low pressures (<1.5 × 10(-6) to 2.8 × 10(-5) hPa) was reduced by defocusing the beam. At very low pressures (<1.5 × 10(-6) hPa) the spatial resolution with a defocused beam at 10 kV was about 3 µm in the x-direction at -150°C and 0.5 µm at -120°C, because at higher temperature charging was less and only a small defocus was needed to compensate it. Angular resolution was better than 0.7° after orientation averaging. Excellent agreement was obtained between LM etch features and EBSD mapped microstructures. First results are shown, which indicate subgrain boundary types comprised of basal (tilt and twist) and nonbasal dislocations (tilt boundaries).

4.
J Microsc ; 226(Pt 3): 263-9, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17535265

RESUMO

The combination of focused ion beam and scanning electron microscopy with a cryo-preparation/transfer system allows specimens to be milled at low temperatures. However, for biological specimens in particular, the quality of results is strongly dependent on correct preparation of the specimen surface. We demonstrate a method for deposition of a protective, planarizing surface layer onto a cryo-sample, enabling high-quality cross-sectioning using the ion beam and investigation of structures at the nanoscale.