Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(20): 4635-4645, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38949681

RESUMO

17α-Hydroxyprogesterone (17α-OHP) quantification in dried blood spots (DBS) is essential for newborn screening for congenital adrenal hyperplasia (CAH), which is challenging due to its low physiological concentration. The high false-positive rates of immunoassays necessitate the development of more accurate methods. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers increased specificity and sensitivity, yet standardized procedures for 17α-OHP measurement are required for clinical application. A candidate reference measurement procedure (cRMP) using isotope dilution LC-MS/MS was developed for 17α-OHP quantification in DBS. By utilizing stable isotope-labeled D8-17α-OHP as an internal standard, the cRMP was optimized, covering sample preparation, calibration, and LC-MS/MS analysis. The method performance was validated across several parameters, including precision, accuracy, specificity, detection limits, and matrix effects. Clinical applicability was further assessed through the establishment of reference intervals for healthy newborns. The developed cRMP exhibited a linear range of 1.00 to 80.00 ng/mL for 17α-OHP, with detection and quantification limits of 0.14 ng/mL and 0.52 ng/mL, respectively. Inter- and intraday precision demonstrated coefficients of variation within 1.27 to 5.69%. The recovery rates and matrix effects were well within acceptable limits, ensuring method reliability. Clinical application showed distinct reference intervals for healthy newborns that were unaffected by sex but influenced by weight and gestational age. This method significantly enhances CAH diagnostic accuracy in newborns, providing a valuable tool for clinical laboratories and improving newborn screening program standardization and traceability.


Assuntos
17-alfa-Hidroxiprogesterona , Teste em Amostras de Sangue Seco , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Teste em Amostras de Sangue Seco/métodos , 17-alfa-Hidroxiprogesterona/sangue , Recém-Nascido , Cromatografia Líquida/métodos , Limite de Detecção , Padrões de Referência , Hiperplasia Suprarrenal Congênita/sangue , Hiperplasia Suprarrenal Congênita/diagnóstico , Triagem Neonatal/métodos , Reprodutibilidade dos Testes , Técnicas de Diluição do Indicador , Feminino , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA