Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Europace ; 25(2): 506-516, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36256597

RESUMO

AIMS: Arrhythmic mitral valve syndrome is linked to life-threatening ventricular arrhythmias. The incidence, morphology and methods for risk stratification are not well known. This prospective study aimed to describe the incidence and the morphology of ventricular arrhythmia and propose risk stratification in patients with arrhythmic mitral valve syndrome. METHODS: Arrhythmic mitral valve syndrome patients were monitored for ventricular tachyarrhythmias by implantable loop recorders (ILR) and secondary preventive implantable cardioverter-defibrillators (ICD). Severe ventricular arrhythmias included ventricular fibrillation, appropriate or aborted ICD therapy, sustained ventricular tachycardia and non-sustained ventricular tachycardia with symptoms of hemodynamic instability. RESULTS: During 3.1 years of follow-up, severe ventricular arrhythmia was recorded in seven (12%) of 60 patients implanted with ILR [first event incidence rate 4% per person-year, 95% confidence interval (CI) 2-9] and in four (20%) of 20 patients with ICD (re-event incidence rate 8% per person-year, 95% CI 3-21). In the ILR group, severe ventricular arrhythmia was associated with frequent premature ventricular complexes, more non-sustained ventricular tachycardias, greater left ventricular diameter and greater posterolateral mitral annular disjunction distance (all P < 0.02). CONCLUSIONS: The yearly incidence of ventricular arrhythmia was high in arrhythmic mitral valve syndrome patients without previous severe arrhythmias using continuous heart rhythm monitoring. The incidence was even higher in patients with secondary preventive ICD. Frequent premature ventricular complexes, non-sustained ventricular tachycardias, greater left ventricular diameter and greater posterolateral mitral annular disjunction distance were predictors of first severe arrhythmic event.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Humanos , Valva Mitral/diagnóstico por imagem , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Complexos Ventriculares Prematuros/complicações , Síndrome , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia
2.
Heart Rhythm ; 19(9): 1433-1441, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35716856

RESUMO

BACKGROUND: Obstructive sleep apnea (OSA) is associated with atrial fibrillation (AF). Whether treatment with continuous positive airway pressure (CPAP) reduces AF recurrence after catheter ablation with pulmonary vein isolation (PVI) is unknown. OBJECTIVE: The purpose of this study was to assess the effect of CPAP treatment on the recurrence and burden of AF after PVI in patients with OSA. METHODS: We randomized patients with paroxysmal AF and an apnea-hypopnea index (AHI) ≥15 events/hour to treatment with CPAP or standard care. Heart rhythm was monitored by an implantable loop recorder. AF recurrence after PVI was defined as any episode of AF lasting >2 minutes after a 3-month blanking period. RESULTS: PVI was performed in 83 patients. Thirty-seven patients were randomized to CPAP treatment and 46 patients to standard care. The AHI was reduced from 26.7 ± 14 events/hour to 1.7 ± 1.3 events/hour at follow-up in the CPAP group (P = .001). A total of 57% of patients in both the CPAP group and the standard care group had at least 1 episode of AF 3-12 months after PVI (P for difference = 1). AF burden after ablation was reduced in both groups, with no between-group difference (P = .69). CONCLUSION: In patients with paroxysmal AF and OSA, treatment with CPAP did not further reduce the risk of AF recurrence after ablation. PVI considerably reduced the burden of AF in OSA patients, without any difference between groups.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Apneia Obstrutiva do Sono , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Veias Pulmonares/cirurgia , Recidiva , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
3.
JACC Clin Electrophysiol ; 7(1): 85-96, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33478716

RESUMO

OBJECTIVES: This multicenter registry aimed to assess the reproducibility and safety of intentional coronary vein exit and carbon dioxide insufflation to facilitate subxiphoid epicardial access in the setting of ventricular tachycardia ablation. BACKGROUND: Epicardial ablation for ventricular tachycardia is not a widespread technique due to the significant potential complications associated with subxiphoid puncture. The first experience in 12 patients showed that intentional coronary vein exit and carbon dioxide insufflation was technically feasible. METHODS: A branch of the coronary sinus was cannulated by means of a diagnostic JR4 coronary catheter. Intentional perforation at the distal portion of that branch was performed with a high tip load 0.014-inch angioplasty wire. A microcatheter was advanced over the wire into the pericardial space. Carbon dioxide was then insufflated into the pericardial space, allowing direct visualization of the anterior pericardial space to facilitate subxiphoid puncture. RESULTS: Intentional coronary vein exit was attempted in 102 consecutive patients in 16 different centers and successfully completed in 101 patients. Significant pericardial adhesions were confirmed in 3 patients, preventing carbon dioxide insufflation and epicardial ablation. None of the punctures were complicated with inadvertent right ventricular puncture or damage to a coronary artery. Significant bleeding (>80 ml) due to coronary vein exit occurred in 5 patients, without hemodynamic compromise. None of the patients required surgery. CONCLUSIONS: Coronary vein exit and carbon dioxide insufflation can be safely and reproducibly achieved to facilitate subxiphoid pericardial access in the setting of ventricular tachycardia ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Humanos , Sistema de Registros , Reprodutibilidade dos Testes , Taquicardia Ventricular/cirurgia
4.
J Cardiovasc Pharmacol ; 56(3): 300-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20588189

RESUMO

BACKGROUND: This study assessed the cardiac electrophysiological and hemodynamic effects of an intravenous infusion of the combined ion channel blocker AZD1305. METHODS: After successful ablation of atrial flutter, patients were randomized to receive placebo (n = 12) or AZD1305 (n = 38) in 4 ascending dose groups. Electrophysiological and hemodynamic measurements were performed before and commencing 20 minutes after start of infusion. RESULTS: Left atrial effective refractory period increased dose and the primary outcome measure increased dose and plasma concentration dependently, with a mean increase of 55 milliseconds in dose group 3. There was a corresponding increase in right atrial effective refractory period of 84 milliseconds. The right ventricular effective refractory period and the paced QT interval also increased dose and concentration dependently, by 59 and 70 milliseconds, respectively, in dose group 3. There were indications of moderate increases of atrial, atrioventricular nodal, and ventricular conduction times. No consistent changes in intracardiac pressures were observed, but there was a small transient decrease in systolic blood pressure. Adverse events were consistent with the study population and procedure, and there were no signs of proarrhythmia despite marked delay in ventricular repolarization in some individuals. CONCLUSIONS: AZD1305 shows electrophysiological characteristics indicative of potential antiarrhythmic efficacy in atrial fibrillation.


Assuntos
Flutter Atrial/cirurgia , Compostos Azabicíclicos/farmacologia , Bloqueadores dos Canais de Cálcio/farmacologia , Carbamatos/farmacologia , Ablação por Cateter , Bloqueadores dos Canais de Sódio/farmacologia , Adulto , Idoso , Compostos Azabicíclicos/administração & dosagem , Compostos Azabicíclicos/efeitos adversos , Bloqueadores dos Canais de Cálcio/administração & dosagem , Bloqueadores dos Canais de Cálcio/efeitos adversos , Carbamatos/administração & dosagem , Carbamatos/efeitos adversos , Relação Dose-Resposta a Droga , Método Duplo-Cego , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/efeitos dos fármacos , Hemodinâmica/efeitos dos fármacos , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Período Refratário Eletrofisiológico/efeitos dos fármacos , Bloqueadores dos Canais de Sódio/administração & dosagem , Bloqueadores dos Canais de Sódio/efeitos adversos
5.
Europace ; 11(10): 1301-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19666643

RESUMO

AIMS: To evaluate the effects of the angiotensin II type 1 receptor blocker candesartan on P-wave signal-averaged electrocardiogram (P-SAECG) after electrical cardioversion in patients with atrial fibrillation (AF). METHODS AND RESULTS: One hundred and seventy-one patients with persistent AF were randomized to receive candesartan 8 mg/day or placebo for 3-6 weeks before and candesartan 16 mg/day or placebo for 6 months after electrical cardioversion. P-SAECG was recorded in 114 patients (57 in each treatment group) after cardioversion and repeated in those with sinus rhythm at 1 and 6 weeks, and 3 and 6 months. Filtered P-wave duration (FPD), root-mean-squared (RMS) voltages of the terminal 40 ms of the filtered P-wave, RMS voltage of the entire filtered P-wave, and the integral of the voltages in the entire PD were analysed. No effects of candesartan were observed on any P-SAECG parameter at baseline. In the subgroup of patients in sinus rhythm after 6 months, FPD was significantly shorter both at baseline (151 +/- 16 vs. 163 +/- 16 ms) and at 6 months (143 +/- 12 vs. 153 +/- 15 ms) in the candesartan (n = 15) compared with the placebo group (n = 21). CONCLUSION: Treatment with candesartan was associated with a shorter FPD in patients remaining in sinus rhythm for 6 months.


Assuntos
Fibrilação Atrial/etiologia , Fibrilação Atrial/prevenção & controle , Benzimidazóis/administração & dosagem , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia/efeitos dos fármacos , Processamento de Sinais Assistido por Computador , Tetrazóis/administração & dosagem , Idoso , Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Compostos de Bifenilo , Diagnóstico por Computador/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Secundária , Resultado do Tratamento
8.
J Am Coll Cardiol ; 72(14): 1600-1609, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-30261961

RESUMO

BACKGROUND: Mitral annulus disjunction (MAD) is an abnormal atrial displacement of the mitral valve leaflet hinge point. MAD has been associated with mitral valve prolapse (MVP) and sudden cardiac death. OBJECTIVES: The purpose of this study was to describe the clinical presentation, MAD morphology, association with MVP, and ventricular arrhythmias in patients with MAD. METHODS: The authors clinically examined patients with MAD. By echocardiography, the authors assessed the presence of MVP and measured MAD distance in parasternal long axis. Using cardiac magnetic resonance (CMR), the authors assessed circumferential MAD in the annular plane, longitudinal MAD distance, and myocardial fibrosis. Aborted cardiac arrest and sustained ventricular tachycardia were defined as severe arrhythmic events. RESULTS: The authors included 116 patients with MAD (age 49 ± 15 years; 60% female). Palpitations were the most common symptom (71%). Severe arrhythmic events occurred in 14 (12%) patients. Longitudinal MAD distance measured by CMR was 3.0 mm (interquartile range [IQR]: 0 to 7.0 mm) and circumferential MAD was 150° (IQR: 90° to 210°). Patients with severe arrhythmic events were younger (age 37 ± 13 years vs. 51 ± 14 years; p = 0.001), had lower ejection fraction (51 ± 5% vs. 57 ± 7%; p = 0.002) and had more frequently papillary muscle fibrosis (4 [36%] vs. 6 [9%]; p = 0.03). MVP was evident in 90 (78%) patients and was not associated with ventricular arrhythmia. CONCLUSIONS: Ventricular arrhythmias were frequent in patients with MAD. A total of 26 (22%) patients with MAD did not have MVP, and MVP was not associated with arrhythmic events, indicating MAD itself as an arrhythmogenic entity. MAD was detected around a large part of the mitral annulus circumference and was interspersed with normal tissue.


Assuntos
Valva Mitral/anormalidades , Valva Mitral/diagnóstico por imagem , Adulto , Arritmias Cardíacas/etiologia , Estudos Transversais , Morte Súbita Cardíaca/etiologia , Ecocardiografia , Feminino , Fibrose/diagnóstico por imagem , Parada Cardíaca/etiologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Prolapso da Valva Mitral/etiologia , Músculos Papilares/diagnóstico por imagem , Músculos Papilares/patologia , Síndrome , Complexos Ventriculares Prematuros/etiologia
9.
ESC Heart Fail ; 4(4): 585-594, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29154430

RESUMO

AIMS: We aimed to explore the burden of frequent premature ventricular contractions (PVCs) associated with myocardial dysfunction in patients with outflow tract arrhythmia (OTA). We hypothesized that this threshold is lower than the previously suggested threshold of 24 000 PVCs/24 h (24%PVC) when systolic function is assessed by strain echocardiography. Furthermore, we aimed to characterize OTA patients with malignant arrhythmic events. METHODS AND RESULTS: We included 52 patients referred for OTA ablation (46 ± 12 years, 58% female). Left ventricular global longitudinal strain (GLS) and mechanical dispersion were assessed by speckle tracking echocardiography. A subset underwent cardiac magnetic resonance imaging. PVC burden (%PVC) was assessed by Holter recording. Sinus rhythm QRS duration and PVC QRS duration were recorded from electrocardiogram, and the ratio was calculated (PVC QRS duration / sinus rhythm QRS duration). Median %PVC was 7.2 (0.2-60.0%). %PVC correlated with GLS (R = 0.44, P = 0.002) and with mechanical dispersion (R = 0.48, P < 0.001), but not with ejection fraction (R = 0.22, P = 0.12). %PVC was higher in patients with impaired systolic function by GLS (worse than -18%) compared with patients with normal function (22% vs. 5%, P = 0.001). Greater than 8%PVC optimally identified patients with abnormal GLS (area under the curve 0.79). Serious arrhythmic events occurred in 11/52 (21%) patients characterized by high QRS ratios (1.56 vs. 1.91, P < 0.001). CONCLUSIONS: More than 8%PVC was associated with impaired systolic function by GLS, which is a lower threshold than previously reported. Patients with serious arrhythmic events had higher QRS ratios, which may represent a more malignant phenotype of OTA.


Assuntos
Eletrocardiografia Ambulatorial , Ventrículos do Coração/diagnóstico por imagem , Miocárdio/patologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Complexos Ventriculares Prematuros/fisiopatologia , Adulto , Ecocardiografia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Complexos Ventriculares Prematuros/diagnóstico
10.
Eur Heart J Cardiovasc Imaging ; 17(6): 660-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26219297

RESUMO

AIMS: We evaluated if a dispersed left atrial (LA) contraction pattern was related to atrial fibrillation (AF) in patients with normal left ventricular (LV) function, and normal or mildly enlarged left atrium. METHODS AND RESULTS: We included 61 patients with paroxysmal AF (PAF). Of these, 30 had not while 31 had recurrence of AF after radiofrequency ablation (RFA). Twenty healthy individuals were included for comparison. Echocardiography was performed in patients in sinus rhythm the day before RFA. LA volume was calculated. Peak negative longitudinal strain was assessed in 18 LA segments during atrial systole. Contraction duration in 18 LA segments was measured as the time from peak of the P wave on electrocardiogram to maximum myocardial shortening in each segment. The standard deviation of contraction durations was defined as LA mechanical dispersion (LA MD). LA size was rather preserved in patients with PAF (LA volume 25 ± 10 mL/m(2)). LA MD was more pronounced in patients with recurrence of AF after RFA compared with those without recurrence and controls (38 ± 14 ms vs. 30 ± 12 ms vs. 16 ± 8 ms, both P < 0.001). LA MD was a predictor of PAF [OR 7.84 (95%CI 2.15-28.7), P < 0.01, per 10 ms increase] adjusted for age, LA volume, e', and LA function. LA function by strain was reduced in both patients with and without recurrent AF after RFA compared with controls (-14 ± 4% vs. -16 ± 3% vs. -19 ± 2%, both P < 0.05). CONCLUSION: LA MD was pronounced, and LA deformation was reduced in patients with PAF with apparently normal LV structure and function, and normal or mildly enlarged LA. LA MD may be useful as a predictor of AF recurrence after RFA.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo/fisiologia , Ablação por Cateter/métodos , Ecocardiografia , Interpretação de Imagem Assistida por Computador , Adulto , Área Sob a Curva , Fibrilação Atrial/diagnóstico por imagem , Estudos de Casos e Controles , Eletrocardiografia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Análise Multivariada , Valor Preditivo dos Testes , Prognóstico , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
11.
Int J Cardiol ; 116(1): 86-92, 2007 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-16815571

RESUMO

BACKGROUND: A randomised study was conducted to determine if short-term exercise training in patients with chronic atrial fibrillation (AF) might improve symptoms and health-related quality of life (HRQoL). METHODS: AF patients (64+/-7 years) were randomised to exercise training (n=15) or a 2-month control period (n=15) followed by an exercise training program (ETP). The ETP consisted of 24 training sessions with aerobic exercise and muscle strengthening. A cycle ergometer test, with recording of perceived exertion on the Borg scale, was performed. The participants completed HRQoL questionnaires, the Short-Form 36 (SF-36) and Symptom and Severity Checklist (SSCL), before and after training. Because there were no changes after two months in the control group, pooled data for all patients are presented before and after training. RESULTS: Four of the eight SF-36 scales improved significantly (p<0.05) following training: physical functioning (82+/-14 pre-ETP, 86+/-10 post-ETP), bodily pain (82+/-17 pre-ETP, 92+/-14 post-ETP), vitality (61+/-14 pre-ETP, 68+/-13 post-ETP) and role-emotional (85+/-28 pre-ETP, 94+/-20 post-ETP). The SF-36 physical component summary scale also increased from 49+/-6 pre-ETP to 52+/-6 post-ETP (p<0.05). Significant improvements were also observed for summary and specific symptom scores of the SSCL. Exercise capacity improved by 41+/-20% and perceived exertion during testing by 1.4 points after training (p<0.05 for both). CONCLUSIONS: The study demonstrates a significant improvement in HRQoL, symptoms during exercise testing and exercise capacity after a short-term exercise training program in patients with chronic AF.


Assuntos
Fibrilação Atrial/terapia , Terapia por Exercício/métodos , Qualidade de Vida , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/psicologia , Doença Crônica , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente
12.
J Cardiopulm Rehabil ; 26(1): 24-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16617223

RESUMO

PURPOSE: A randomized study was conducted to determine whether short-term exercise training in patients with chronic atrial fibrillation (AF) might improve exercise capacity and quality of life (QOL), and influence atrioventricular conduction. METHODS: Atrial fibrillation patients (age 64 +/- 7 years) were randomized to exercise training (n = 15) or a 2-month control period (n = 15) followed by the training program. Twenty-four training sessions consisted of aerobic exercise and muscle strengthening. A cycle ergometer test and a 15-minute resting high-frequency spectral electrocardiogram analysis were performed and a QOL questionnaire (SF-36) was completed before and after training. Because there were no changes after 2 months in the control group, pooled data for all patients are presented before and after training. RESULTS: Cumulated work at Borg scale 17 increased by 41% +/- 36%. Heart rate at rest and after 10 minutes of exercise decreased from 75 +/- 14 to 68 +/- 14 bpm and 145 +/- 19 to 137 +/- 21 bpm, respectively. HF increased from 81 +/- 17 to 91 +/- 22 milliseconds. Four of the 8 scales and 1 of the 2 summary scales of the Short-Form-36 improved. P <.05 for all results. CONCLUSIONS: Exercise capacity, heart rate variability, and QOL improved after 2 months of exercise training in patients with chronic AF. Heart rates at rest and during exercise decreased.


Assuntos
Fibrilação Atrial/terapia , Nó Atrioventricular/fisiopatologia , Terapia por Exercício/métodos , Tolerância ao Exercício/fisiologia , Frequência Cardíaca/fisiologia , Qualidade de Vida , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/psicologia , Doença Crônica , Eletrocardiografia Ambulatorial , Teste de Esforço , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 15(10): 1141-6, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15485437

RESUMO

INTRODUCTION: Modification of AV nodal conduction by radiofrequency ablation (RFA) results in a variable reduction in heart rate during atrial fibrillation (AF). Using AF induced in patients with dual AV nodal pathways as a model, we tested the effect of additional treatment with digitalis (ouabain) and beta-blocker (esmolol). METHODS AND RESULTS: Ten patients were randomized to control (group I) and studied only before ablation. AF was induced in 30 patients before and after slow pathway ablation (group II). Mean ventricular cycle lengths (AF CLmean) were recorded. Slow pathway conduction was eliminated after ablation in 10 patients (group IIA), whereas slow pathway conduction was still present in 20 patients (group IIB). Compared to pre-RFA there was a 10% increase in AF CLmean post-RFA (P < 0.01). During isoproterenol infusion the increase was 8% (P = NS). Adding digitalis and beta-blocker during isoproterenol infusion increased AF CLmean by 75% (95% in group IIA) compared to 36% in group I (P < 0.001 II vs I). CONCLUSION: Slow pathway ablation reduces ventricular rate during AF. Addition of digitalis and beta-blocker during isoproterenol infusion significantly decreases ventricular rate after ablation compared to the control group. The finding suggests that beta-blocker has significant effects on fast AV nodal pathway conduction during induced AF with isoproterenol infusion.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Nó Atrioventricular/fisiologia , Ablação por Cateter , Glicosídeos Digitálicos/uso terapêutico , Sistema de Condução Cardíaco/fisiologia , Fibrilação Atrial/induzido quimicamente , Nó Atrioventricular/efeitos dos fármacos , Feminino , Sistema de Condução Cardíaco/efeitos dos fármacos , Humanos , Isoproterenol , Masculino , Pessoa de Meia-Idade
14.
Scand Cardiovasc J ; 37(4): 199-204, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12944207

RESUMO

OBJECTIVE: AV node modification reduces ventricular rate during atrial fibrillation (AF). We induced AF in patients with dual AV nodal pathways before and after radiofrequency ablation (RFA) of AV nodal reentry tachycardia (AVNRT) and examined the role of the two pathways in the transmission of impulses during AF. DESIGN AND RESULTS: AF was induced in 30 patients before and after slow pathway ablation. Before RFA mean (AF CLmean) and shortest (AF CLshort) ventricular cycle lengths correlated significantly to ERPf, ERPs, and antegrade Wenckebach block (r = 0.53-0.67). Ablation eliminated slow pathway conduction completely in 10 patients (group A), whereas in 20 patients some slow pathway conduction was still present (group B). After RFA there was a 10% increase in AF CLmean (20%, p < 0.05 in A and 5%, p = NS in B) and 7% in AF CLshort (11%, p = NS in A and 6%, p = NS in B). During isoproterenol infusion after RFA AF CLmean increased 8% (p < 0.05) (14% in A and 6% in B; p < 0.05 in both groups). The effects of RFA were mainly confined to patients with ERPs less than the median value (13% vs 3% in those above median, respectively; p < 0.05). CONCLUSION: The refractory periods of the AV nodal pathways are the main determinants of ventricular rate during induced AF. Slow pathway ablation reduces ventricular rate during AF. This effect was greatest when slow pathway conduction was completely eliminated. A short ERPs predicted a greater reduction in ventricular rate.


Assuntos
Fibrilação Atrial/patologia , Nó Atrioventricular/patologia , Agonistas Adrenérgicos beta/uso terapêutico , Adulto , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Nó Atrioventricular/fisiopatologia , Nó Atrioventricular/cirurgia , Ablação por Cateter , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca/efeitos dos fármacos , Frequência Cardíaca/fisiologia , Humanos , Isoproterenol/uso terapêutico , Masculino , Pessoa de Meia-Idade , Período Refratário Eletrofisiológico/efeitos dos fármacos , Período Refratário Eletrofisiológico/fisiologia , Estatística como Assunto , Taquicardia por Reentrada no Nó Atrioventricular/patologia , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Resultado do Tratamento , Função Ventricular/efeitos dos fármacos , Função Ventricular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA