Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 122(3): 503-510, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28035014

RESUMO

Detailed information on the distribution of airway diameters during bronchoconstriction in situ is required to understand the regional response of the lungs. Imaging studies using computed tomography (CT) have previously measured airway diameters and changes in response to bronchoconstricting agents, but the manual measurements used have severely limited the number of airways measured per subject. Hence, the detailed distribution and heterogeneity of airway responses are unknown. We have developed and applied dynamic imaging and advanced image-processing methods to quantify and compare hundreds of airways in vivo. The method, based on CT, was applied to house dust-mite-sensitized and control mice during intravenous methacholine (MCh) infusion. Airway diameters were measured pre- and post-MCh challenge, and the results compared demonstrate the distribution of airway response throughout the lungs during mechanical ventilation. Forced oscillation testing was used to measure the global response in lung mechanics. We found marked heterogeneity in the response, with paradoxical dilation of airways present at all airway sizes. The probability of paradoxical dilation decreased with decreasing baseline airway diameter and was not affected by pre-existing inflammation. The results confirm the importance of considering the lung as an entire interconnected system rather than a collection of independent units. It is hoped that the response distribution measurements can help to elucidate the mechanisms that lead to heterogeneous airway response in vivo.NEW & NOTEWORTHY Information on the distribution of airway diameters during bronchoconstriction in situ is critical for understanding the regional response of the lungs. We have developed an imaging method to quantify and compare the size of hundreds of airways in vivo during bronchoconstriction in mice. The results demonstrate large heterogeneity with both constriction and paradoxical dilation of airways, confirming the importance of considering the lung as an interconnected system rather than a collection of independent units.


Assuntos
Resistência das Vias Respiratórias/efeitos dos fármacos , Brônquios/patologia , Brônquios/fisiopatologia , Testes de Provocação Brônquica , Broncoconstrição/efeitos dos fármacos , Cloreto de Metacolina/farmacologia , Animais , Brônquios/efeitos dos fármacos , Broncoconstritores/farmacologia , Interpretação de Imagem Assistida por Computador , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Reconhecimento Automatizado de Padrão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
2.
Med Device Technol ; 3(5): 30-7, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-10171588

RESUMO

Some materials undergo undesirable changes after sterilization by gamma irradiation, principally related to changes in colour and material properties. However, it is argued that there are ways to overcome these problems; solutions can involve using the most appropriate polymer or reducing the dose that is applied to the product. The new approach to dose setting has led to the view that providing certain conditions are met, a product treated with less than 25 kGy can be sterile without a sterilization test being necessary, which consequently, increases the advantages of this method.


Assuntos
Raios gama , Esterilização/métodos , União Europeia , Arquitetura de Instituições de Saúde , Raios gama/efeitos adversos , Humanos , Polímeros/efeitos da radiação , Polímeros/normas , Controle de Qualidade , Esterilização/instrumentação , Esterilização/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA