Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
N Engl J Med ; 384(4): 345-352, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33503343

RESUMO

BACKGROUND: The minimum duration of pulselessness required before organ donation after circulatory determination of death has not been well studied. METHODS: We conducted a prospective observational study of the incidence and timing of resumption of cardiac electrical and pulsatile activity in adults who died after planned withdrawal of life-sustaining measures in 20 intensive care units in three countries. Patients were intended to be monitored for 30 minutes after determination of death. Clinicians at the bedside reported resumption of cardiac activity prospectively. Continuous blood-pressure and electrocardiographic (ECG) waveforms were recorded and reviewed retrospectively to confirm bedside observations and to determine whether there were additional instances of resumption of cardiac activity. RESULTS: A total of 1999 patients were screened, and 631 were included in the study. Clinically reported resumption of cardiac activity, respiratory movement, or both that was confirmed by waveform analysis occurred in 5 patients (1%). Retrospective analysis of ECG and blood-pressure waveforms from 480 patients identified 67 instances (14%) with resumption of cardiac activity after a period of pulselessness, including the 5 reported by bedside clinicians. The longest duration after pulselessness before resumption of cardiac activity was 4 minutes 20 seconds. The last QRS complex coincided with the last arterial pulse in 19% of the patients. CONCLUSIONS: After withdrawal of life-sustaining measures, transient resumption of at least one cycle of cardiac activity after pulselessness occurred in 14% of patients according to retrospective analysis of waveforms; only 1% of such resumptions were identified at the bedside. These events occurred within 4 minutes 20 seconds after a period of pulselessness. (Funded by the Canadian Institutes for Health Research and others.).


Assuntos
Parada Cardíaca , Coração/fisiologia , Pulso Arterial , Suspensão de Tratamento , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Extubação , Pressão Sanguínea/fisiologia , Morte , Eletrocardiografia , Feminino , Testes de Função Cardíaca , Humanos , Cuidados para Prolongar a Vida , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
2.
J Intensive Care Med ; : 8850666241291524, 2024 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-39444331

RESUMO

IMPORTANCE: Extubation Advisor (EA) is a novel software tool that generates a synoptic report for each Spontaneous Breathing Trial (SBT) conducted to inform extubation decision-making. OBJECTIVES: To assess bedside EA implementation, perceptions of utility, and identify barriers and facilitators of use. DESIGN, SETTING AND PARTICIPANTS: We conducted a phase I mixed-methods interventional study in three mixed intensive care unit (ICUs) in two academic hospitals. We interviewed critical care physicians (MDs) and respiratory therapists (RTs) regarding user-centered design principles and usability. ANALYSIS: We evaluated our ability to consent participants (feasibility threshold 50%), capture complete data (threshold 90%), generate and review EA reports in real-time (thresholds 75% and 80%, respectively), and MD perception of tool usefulness (6-point Likert scale). We analyzed interview transcripts using inductive coding to identify facilitators and barriers to EA implementation and perceived benefit of tool use. RESULTS: We enrolled 31 patients who underwent 70 SBTs. Although consent rates [31/31 (100%], complete data capture [68/68 (100%)], and EA report generation [68/70 (97.1%)] exceeded feasibility thresholds, reports were reviewed by MDs for [55/70 (78.6%)] SBTs. Mean MD usefulness score was 4.0/6. Based on feedback obtained from 36 interviews (15 MDs, 21 RTs), we revised the EA report twice and identified facilitators (ability to track patient progress, enhance extubation decision-making, and provide support in resource-limited settings) and barriers (resource constraints, need for education) to tool implementation. Half of respondents (9 MDs, 9 RTs; combined 50%) perceived definite or potential benefit to EA tool use. CONCLUSION: This is the first study of a waveform-based variability-derived, predictive clinical decision support tool evaluated in adult ICUs. Our findings support the feasibility of integrating the EA tool into bedside workflow. Clinical trials are needed to assess the utility of the EA tool in practice and its impact on extubation decision-making and outcomes. TRIAL REGISTRATION: NCT04708509.

3.
Eur J Appl Physiol ; 122(5): 1249-1259, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35239038

RESUMO

PURPOSE: In older adults with type 2 diabetes (T2D) and hypertension (HTN), cardiac autonomic modulation is markedly attenuated during exercise-heat stress. However, the extent to which this impairment is evident under increasing levels of heat stress remains unknown. METHODS: We examined heart rate variability (HRV), a surrogate of cardiac autonomic modulation, during incremental exercise-heat stress exposures in young (20-30 years) and middle-aged-to-older individuals (50-70 years) without and with T2D and HTN. Thirteen young and healthy (Young, n = 13) and 37 older men without (Older, n = 14) and with HTN (n = 13) or T2D (n = 10) performed 180-min treadmill walking at a fixed metabolic rate (~ 200 W/m2; ~ 3.5 METs) in a differing wet-bulb globe temperature (WBGT; 16 °C, 24 °C, 28 °C, and 32 °C). Electrocardiogram (ECG) and core temperature measurements were recorded throughout. Data were analysed using 5-min averaged epochs following 60-min exercise, which represented the last common timepoint across groups and conditions. RESULTS: Ageing did not significantly reduce HRV during increasing exercise-heat stress (all p > 0.050). However, T2D and HTN modified HRV during exercise-heat stress such that Detrended Fluctuation Analysis (DFA) α1 (p = 0.012) and the cardiac sympathetic index (p = 0.037) were decreased compared to Older in all except the warmest WBGT condition (32 °C). CONCLUSION: Our unique observations indicate that, relative to their younger counterparts, HRV in healthy older individuals is not perturbed during exercise heat-stress. However, relative to their age-matched healthy counterparts, HRV is reduced during exercise-heat stress in individuals with age-associated chronic conditions, indicative of cardiac autonomic dysfunction.


Assuntos
Diabetes Mellitus Tipo 2 , Transtornos de Estresse por Calor , Hipertensão , Idoso , Frequência Cardíaca/fisiologia , Resposta ao Choque Térmico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
4.
Int J Technol Assess Health Care ; 38(1): e66, 2022 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-35811412

RESUMO

OBJECTIVES: To estimate the minimum percent change in failed extubation to make a tool designed to reduce extubation failure (Extubation Advisor [EA]) economically viable. METHODS: We conducted an early return on investment (ROI) analysis using data from intubated intensive care unit (ICU) patients at a large Canadian tertiary care hospital. We obtained input parameters from the hospital database and published literature. We ran generalized linear models to estimate the attributable length of stay, total hospital cost, and time to subsequent extubation attempt following failure. We developed a Markov model to estimate the expected ROI and performed probabilistic sensitivity analyses to assess the robustness of findings. Costs were presented in 2020 Canadian dollars (C$). RESULTS: The model estimated a 1 percent reduction in failed extubation could save the hospital C$289 per intubated patient (95 percent CI: 197, 459). A large center seeing 2,500 intubated ICU patients per year could save C$723,124/year/percent reduction in failed extubation. At the current annual price of C$164,221, the EA tool must reduce extubation failure by at least 0.24 percent (95 percent CI: .14, .41) to make the tool cost-effective at our site. CONCLUSIONS: Clinical decision-support tools like the EA may play an important role in reducing healthcare costs by reducing the rate of extubation failure, a costly event in the ICU.


Assuntos
Extubação , Desmame do Respirador , Canadá , Estudos de Viabilidade , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Respiração Artificial
5.
Can J Neurol Sci ; 48(2): 226-232, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32684195

RESUMO

BACKGROUND: Mean cerebral blood flow velocity (mean-CBFV) obtained from Transcranial Doppler (TCD) poorly predicts cerebral vasospasm in patients with aneurysmal subarachnoid hemorrhage (aSAH). Variability descriptors of mean-CBFV obtained during extended TCD recordings may improve this prediction. We assessed the feasibility of generating reliable linear and non-linear descriptors of mean-CBFV variability using extended recordings in aSAH patients and in healthy controls. We also explored which of those metrics might have the ability to discriminate between aSAH patients and healthy controls, and among patients who would go on to develop vasospasm and those who would not. METHODS: Bilateral mean-CBFV, blood pressure, and heart rate were continuously recorded for 40 minutes in aSAH patients (n = 8) within the first 5 days after ictus, in age-matched healthy controls (n = 8) and in additional young controls (n = 8). We obtained linear [standard deviation, coefficient of variations, and the very-low (0.003-0.040 Hz), low (0.040-0.150 Hz), and high-frequency (0.15-0.4 Hz) power spectra] and non-linear (Fractality, deterministic Chaos analyses) variability metrics. RESULTS: We successfully obtained TCD recordings from patients and healthy controls and calculated the desired metrics of mean-CBFV variability. Differences were appreciable between aSAH patients and healthy controls, as well as between aSAH patients who later developed vasospasm and those who did not. CONCLUSIONS: A 40-minute TCD recording provides reliable variability metrics in aSAH patients and healthy controls. Future studies are required to determine if mean-CBFV variability metrics remain stable over time, and whether they may serve to identify patients who are at greatest risk of developing cerebral vasospasm after aSAH.


Assuntos
Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Circulação Cerebrovascular , Estudos de Viabilidade , Humanos , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia
6.
J Physiol ; 598(2): 249-263, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31802494

RESUMO

KEY POINTS: We introduce a technique to test whether intrinsic fetal heart rate variability (iFHRV) exists and we show the utility of the technique by testing the hypothesis that iFHRV is affected by chronic fetal hypoxia, one of the most common adverse outcomes of human pregnancy complicated by fetal growth restriction. Using an established late gestation ovine model of fetal development under chronic hypoxic conditions, we identify iFHRV in isolated fetal hearts and show that it is markedly affected by hypoxic pregnancy. Therefore, the isolated fetal heart has intrinsic variability and carries a memory of adverse intrauterine conditions experienced during the last third of pregnancy. ABSTRACT: Fetal heart rate variability (FHRV) emerges from influences of the autonomic nervous system, fetal body and breathing movements, and from baroreflex and circadian processes. We tested whether intrinsic heart rate variability (iHRV), devoid of any external influences, exists in the fetal period and whether it is affected by chronic fetal hypoxia. Chronically catheterized ewes carrying male singleton fetuses were exposed to normoxia (n = 6) or hypoxia (10% inspired O2 , n = 9) for the last third of gestation (105-138 days of gestation (dG); term ∼145 dG) in isobaric chambers. At 138 dG, isolated hearts were studied using a Langendorff preparation. We calculated basal intrinsic FHRV (iFHRV) indices reflecting iFHRV's variability, predictability, temporal symmetry, fractality and chaotic behaviour, from the systolic peaks within 15 min segments in each heart. Significance was assumed at P < 0.05. Hearts of fetuses isolated from hypoxic pregnancy showed approximately 4-fold increases in the Grid transformation as well as the AND similarity index (sgridAND) and a 4-fold reduction in the scale-dependent Lyapunov exponent slope. We also detected a 2-fold reduction in the Recurrence quantification analysis, percentage of laminarity (pL) and recurrences, maximum and average diagonal line (dlmax, dlmean) and the Multiscale time irreversibility asymmetry index. The iHRV measures dlmax, dlmean, pL and sgridAND correlated with left ventricular end-diastolic pressure across both groups (average R2  = 0.38 ± 0.03). This is the first evidence that iHRV originates in fetal life and that chronic fetal hypoxia significantly alters it. Isolated fetal hearts from hypoxic pregnancy exhibit a time scale-dependent higher complexity in iFHRV.


Assuntos
Hipóxia Fetal/fisiopatologia , Frequência Cardíaca Fetal , Complicações na Gravidez/fisiopatologia , Animais , Feminino , Coração Fetal/fisiopatologia , Masculino , Gravidez , Ovinos
7.
Eur J Appl Physiol ; 120(2): 453-465, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31894413

RESUMO

PURPOSE: This study aimed to detect potential differences in heart-rate variability (HRV) during a moderate-intensity intermittent exercise in the heat among physically active young (25.8 ± 1.9 years), middle-aged (43.5 ± 2.8 years), and older (62.9 ± 3.7 years) men. METHODS: Thirty-three participants (11/group) performed four successive bouts of 15-min cycling at a moderate fixed rate of metabolic heat production of ~ 400 W; each separated by a 15-min recovery with 1 h of final recovery in a hot and dry environment (35 °C, 20% relative humidity). Twelve HRV indices were computed that have been commonly described in the literature, and characterized various domains of the variability and complexity of heart rate. RESULTS: Cardiac autonomic regulation during intermittent exercise in the heat, as well as during pre-exercise rest and recovery was significantly affected by age, as changes were observed among the three different aged groups in five indices (p ≤ 0.05). Similarly, time influenced cardiac autonomic regulation as three indices showed changes across time (p ≤ 0.05) during intermittent exercise, whilst five indices displayed significant changes (p ≤ 0.05) during rest and recovery in the heat. CONCLUSIONS: This study supports that moderate-intensity intermittent exercise in the heat is associated with significant cardiac autonomic dysregulation in older men, as compared to young and middle-aged men, yet it highlights the importance of developing preventative health strategies for heat-related illness in aged individuals.


Assuntos
Envelhecimento , Sistema Nervoso Autônomo/fisiologia , Coração/fisiologia , Eletromiografia , Exercício Físico , Feminino , Coração/inervação , Temperatura Alta , Humanos , Treinamento Resistido , Adulto Jovem
8.
Am J Ind Med ; 63(9): 787-795, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32677129

RESUMO

BACKGROUND: The Threshold Limit Values (TLV) of the American Conference of Governmental and Industrial Hygienists indicate the levels of heat stress that all workers may be repeatedly exposed to without adverse health effects. In this study, we evaluated heart rate variability (HRV) during moderate-to-heavy work performed continuously or according to different TLV work-rest (WR) allocations in healthy physically active older workers. METHODS: Nine healthy older (58 ± 5 years) males performed three different 120-minute conditions in accordance with TLV guidelines for moderate-to-heavy intensity work (360 W fixed rate of heat production) in different wet-bulb globe temperatures (WBGT): continuous cycling at 28°C WBGT (CON), as well as intermitted work performed at WR of 3:1 in 29°C WBGT (WR3:1), and at WR of 1:1 at 30°C (WR1:1). Rectal temperature and HRV (3-lead electrocardiogram [ECG]) were assessed throughout. RESULTS: Coefficient of Variation, Poincaré SD2, and Shannon Entropy were decreased during the CON compared with the WR3:1 when core temperature exceeded 38°C and after 1 hour of continuous work (P < .05). Also, 4 of the 12 HRV indices studied were reduced at CON compared with WR1:1 after 2 hours of accumulated work time (P < .05). Participants worked longer before core temperature reached 38°C during the WR1:1 and the WR3:1, compared with CON (P < .05). CONCLUSIONS: Incorporating breaks during moderate-to-heavy work in the heat for older adults can reduce autonomic stress and prolong the work performed at safe core temperature levels. The TLV WR1:1 provides increased cardiac protection for older workers, as compared with the CON and the WR3:1.


Assuntos
Frequência Cardíaca , Temperatura Alta/efeitos adversos , Níveis Máximos Permitidos , Trabalho/fisiologia , Voluntários Saudáveis , Transtornos de Estresse por Calor/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/etiologia
9.
J Occup Environ Hyg ; 17(9): 383-389, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32649261

RESUMO

Susceptibility to heat illness during physically demanding work in hot environments is greater on the second of two consecutive workdays. While it has been demonstrated that heat storage is exacerbated on the second compared to first workday in older workers (50-65 yr), the effects on heart rate variability (HRV), an established surrogate of cardiac autonomic modulation, remain unclear. This study evaluated HRV in older workers on the day following prolonged work in the heat. Electrocardiogram was recorded in nine older (53-64 yr) males at rest, during three 30-min bouts of semi-recumbent cycling at fixed rates of metabolic heat production (150, 200, 250 W/m2), each separated by 15-min recovery. Experiments were conducted in hot-dry conditions (40 °C, 20% relative humidity), immediately prior to (Day 1), and on the day following (Day 2), a prolonged work simulation (∼7.5 hr) involving moderate intensity intermittent exercise in hot-dry conditions (38 °C, 34% relative humidity). Core temperature, as well as time, frequency, and nonlinear HRV indices were derived for analysis during rest, the final 5-min of exercise at the highest heat production and recovery. The change in core temperature at the end of work (mean ±SD) was significantly greater on Day 2 (1.0 °C ±0.3) relative to Day 1 (0.8 °C ±0.2; p < 0.01). Heart rate, however, did not significantly differ between days 1 and 2 at rest (Day 1, 59 ±11 bpm; Day 2, 62 ±13 bpm), during exercise (Day 1, 113 ±21 bpm; Day 2, 114 ±18 bpm ) and at the end of recovery (Day 1, 75 ±16 bpm; Day 2, 76 ±12 bpm). Likewise, there were no significant differences in any HRV indices derived from time, frequency, and nonlinear domains (all p > 0.05). Prolonged work in the heat did not modulate next-day heart rhythms, as reflected by HRV, despite augmented core temperature. While HRV can reflect physiological aspects of cardiac autonomic stressors, these findings indicate it does not provide a means to identify exacerbated heat strain in older workers over consecutive work shifts in the heat.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Frequência Cardíaca/fisiologia , Temperatura Alta , Esforço Físico/fisiologia , Sistema Nervoso Autônomo/fisiologia , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade
10.
Exp Physiol ; 104(6): 845-854, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30932277

RESUMO

NEW FINDINGS: What is the central question of this study? Does a delay in cold water immersion treatment affect the cardiac autonomic control of exertionally heat-strained individuals? What is the main finding and its importance? Cold water immersion is effective for treating exertionally heat-strained individuals even when treatment is commenced with a significant delay. However, that treatment delay leads to only partial/transient restoration of cardiac autonomic control. Therefore, we recommend that exertional heatstroke patients are continuously monitored for several hours even after core temperature has returned to normal values. ABSTRACT: Immediate cold water immersion (CWI) is the gold-standard treatment for exertional heatstroke. In the field, however, treatment is often delayed, primarily owing to a delayed paramedic response and/or inaccurate diagnosis. We examined the effect of treatment (reduction of rectal temperature to 37.5°C) delays of 5 (short), 20 (moderate) and 40 (prolonged) min on cardiac autonomic control [as assessed via heart rate variability (HRV)] in eight exertionally heat-strained (40.0°C rectal temperature) individuals. Eleven HRV indices were computed that have been described commonly in the literature and characterize almost all known domains of the variability and complexity of the cardiopulmonary system. We found that the cardiac autonomic control (as assessed via HRV) of exertionally heat-strained individuals was significantly affected by the amount of time it took for the CWI treatment to be applied. Six out of 11 HRV indices studied, from all variability domains, displayed strong (P ≤ 0.005) time × delay interaction effects. Moreover, the number of significantly (P ≤ 0.005) abnormal (i.e. different from the short delay) HRV indices more than doubled (seven versus 15) from the moderate delay to the prolonged delay. Finally, our results demonstrated that a CWI treatment applied with delays of 20 and, primarily, 40 min did not lead to a full restoration of cardiac autonomic control of exertionally heat-strained individuals. In conclusion, this study supports CWI for treating exertionally heat-strained individuals even when applied with prolonged delay, but it highlights the importance of continued cardiac monitoring of patients who have suffered exertional heatstroke for several hours after restoration of core temperature to normal.


Assuntos
Temperatura Corporal/fisiologia , Frequência Cardíaca/fisiologia , Golpe de Calor/fisiopatologia , Adulto , Golpe de Calor/terapia , Humanos , Imersão , Masculino , Consumo de Oxigênio/fisiologia , Tempo para o Tratamento , Adulto Jovem
11.
J Emerg Med ; 54(6): 766-773, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29548723

RESUMO

BACKGROUND: Early emergency department (ED) identification of septic patients at risk of deterioration is critical. Lactate is associated with 28-day mortality in admitted patients, but little evidence exists on its use in predicting short-term deterioration. OBJECTIVE: Our aim was to determine the role of initial serum lactate for prediction of short-term deterioration in stable ED patients with suspected sepsis. METHODS: We conducted a prospective cohort study of adult ED sepsis patients. Venous lactate was obtained within 2 h of ED arrival. Main outcome was subsequent deterioration (defined as any of the following: death, intensive care admission > 24 h, intubation, vasoactive medications for > 1 h, or noninvasive positive pressure ventilation for > 1 h) within 72 h. Patients meeting any endpoint within 1 h of arrival were excluded. RESULTS: Nine hundred and eighty-five patients were enrolled, of whom 84 (8.5%) met the primary outcome of deterioration. Initial lactate ≥ 4.0 mmol/L had a specificity of 97% (95% confidence interval [CI] 94-100%), but a sensitivity of 27% (95% CI 18-37%) for predicting deterioration, with positive and negative likelihood ratios of 10.7 (95% CI 6.3-18.3) and 0.8 (95% CI 0.7-0.9), respectively. A lower threshold of lactate (≥2.0 mmol/L) had a sensitivity of 67% (95% CI 55-76%) and specificity of 66% (95% CI 63-69%), with corresponding positive and negative likelihood ratios of 2.0 (95% CI 1.7-2.3) and 0.5 (95% CI 0.4-0.7). CONCLUSIONS: High ED lactate is predictive of subsequent deterioration from sepsis within 72 h, and may be useful in determining disposition, but low lactate is not effective in screening stable patients at risk of deterioration.


Assuntos
Ácido Láctico/análise , Medição de Risco/normas , Sepse/diagnóstico , Adulto , Idoso , Biomarcadores/análise , Biomarcadores/sangue , Estudos de Coortes , Serviço Hospitalar de Emergência/organização & administração , Feminino , Humanos , Ácido Láctico/sangue , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco/métodos , Sepse/induzido quimicamente
12.
Emerg Med J ; 35(2): 96-102, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28821492

RESUMO

OBJECTIVE: To examine the ability of the low-frequency/high-frequency (LF/HF) ratio of heart rate variability (HRV) analysis to identify patients with sepsis at risk of early deterioration. METHODS: This is a prospective observational cohort study of patients with sepsis presenting to the Montefiore Medical Center ED from December 2014 through September 2015. On presentation, a single ECG Holter recording was obtained and analysed to obtain the LF/HF ratio of HRV. Initial Sequential Organ Failure Assessment (SOFA) scores were computed. Patients were followed for 72 hours to identify those with early deterioration. RESULTS: 466 patients presenting to the ED with sepsis were analysed. Thirty-two (7%) reached at least one endpoint within 72 hours. An LF/HF ratio <1 had a sensitivity and specificity of 34% (95% CI (19% to 53%)) and 82% (95% CI (78% to 85%)), respectively, with positive and negative likelihood ratios of 1.9 (95% CI (1.1 to 3.2)) and 0.8 (95% CI (0.6 to 1.0)). An initial SOFA score ≥3 had a sensitivity and specificity of 38% (95% CI (22% to 56%)) and 92% (95% CI (89% to 95%)), with positive and negative likelihood ratios of 4.9 (95% CI (2.8 to 8.6)) and 0.7 (95% CI (0.5 to 0.9)). The composite measure of HRV+SOFA had improved sensitivity (56%, 95% CI (38% to 73%)) but at the expense of specificity (77%, 95% CI (72% to 80%)), with positive and negative likelihood ratios of 2.4 (95% CI (1.7 to 3.4)) and 0.6 (95% CI (0.4 to 0.9)). Receiver operating characteristic analysis did not identify a superior alternate threshold for the LF/HF ratio. Kaplan-Meier survival functions differed significantly (p=0.02) between low (<1) and high (≥1) LF/HF groups. CONCLUSIONS: While we found a statistically significant relationship between HRV, SOFA and HRV+SOFA, and early deterioration, none reliably functioned as a clinical predictive tool. More complex multivariable models will likely be required to construct models with clinical utility.


Assuntos
Deterioração Clínica , Determinação da Frequência Cardíaca/métodos , Ondas de Rádio , Sepse/diagnóstico , Adulto , Idoso , Estudos de Coortes , Eletrocardiografia/métodos , Serviço Hospitalar de Emergência/organização & administração , Feminino , Frequência Cardíaca/fisiologia , Determinação da Frequência Cardíaca/normas , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Sepse/fisiopatologia
13.
Am J Physiol Regul Integr Comp Physiol ; 311(4): R669-R675, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27511279

RESUMO

We examined whether older individuals with and without Type 2 diabetes (T2D) experience differences in heart rate variability (HRV) during a 3-h exposure to high heat stress compared with young adults. Young (Young; n = 22; 23 ± 3 yr) and older individuals with (T2D; n = 11; 59 ± 9 yr) and without (Older; n = 25; 63 ± 5 yr) T2D were exposed to heat stress (44°C, 30% relative humidity) for 3 h. Fifty-five HRV measures were assessed for 15 min at baseline and at minutes 82.5-97.5 (Mid) and minutes 165-180 (End) during heat stress. When compared with Young, a similar number of HRV indices were significantly different (P < 0.05) in Older (Baseline: 35; Mid: 29; End: 32) and T2D (Baseline: 31; Mid: 30; End: 27). In contrast, the number of HRV indices significantly different (P < 0.05) between Older and T2D were far fewer (Baseline: 13, Mid: 1, End: 3). Within-group analyses demonstrated a greater change in the Young group's HRV during heat stress compared with Older and T2D; the number of significantly different (P < 0.05) HRV indices between baseline and End were 42, 29, and 20, for Young, Older, and T2D, respectively. Analysis of specific HRV domains suggest that the Young group experienced greater sympathetic activity during heat stress compared with Older and T2D. In conclusion, when compared with young, older individuals with and without T2D demonstrate low HRV at baseline and less change in HRV (including an attenuated sympathetic response) during 3 h high heat stress, potentially contributing to impaired thermoregulatory function.


Assuntos
Envelhecimento , Regulação da Temperatura Corporal , Diabetes Mellitus Tipo 2/fisiopatologia , Frequência Cardíaca , Resposta ao Choque Térmico , Sistema Nervoso Simpático/fisiologia , Adulto , Temperatura Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
14.
Pediatr Crit Care Med ; 17(4): e165-76, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26914621

RESUMO

OBJECTIVE: Necrotizing enterocolitis of the neonate is an acute inflammatory intestinal disease that can cause necrosis and sepsis. Chorioamnionitis is a risk factor of necrotizing enterocolitis. The gut represents the biggest vagus-innervated organ. Vagal activity can be measured via fetal heart rate variability. We hypothesized that fetal heart rate variability can detect fetuses with incipient gut inflammation. DESIGN: Prospective animal study. SETTING: University research laboratory. SUBJECTS: Chronically instrumented near-term fetal sheep (n = 21). MEASUREMENTS AND MAIN RESULTS: Animals were surgically instrumented with vascular catheters and electrocardiogram to allow manipulation and recording from nonanesthetized animals. In 14 fetal sheep, inflammation was induced with lipopolysaccharide (IV) to mimic chorioamnionitis. Fetal arterial blood samples were drawn at selected time points over 54 hours post lipopolysaccharide for blood gas and cytokines (interleukin-6 and tumor necrosis factor-α enzymelinked immunosorbent assay). Fetal heart rateV was quantified throughout the experiment. The time-matched fetal heart rate variability measures were correlated to the levels of interleukin-6 and tumor necrosis factor-α. Upon necropsy, ionized calcium binding adaptor molecule 1+ (Iba1+), CD11c+ (M1), CD206+ (M2 macrophages), and occludin (leakiness marker) immunofluorescence in the terminal ileum was quantified along with regional Iba1+ signal in the brain (microglia). Interleukin-6 peaked at 3 hours post lipopolysaccharide accompanied by mild cardiovascular signs of sepsis. At 54 hours, we identified an increase in Iba1+ and, specifically, M1 macrophages in the ileum accompanied by increased leakiness, with no change in Iba1 signal in the brain. Preceding this change on tissue level, at 24 hours, a subset of nine fetal heart rate variability measures correlated exclusively to the Iba+ markers of ileal, but not brain, inflammation. An additional fetal heart rate variability measure, mean of the differences of R-R intervals, correlated uniquely to M1 ileum macrophages increasing due to lipopolysaccharide. CONCLUSIONS: We identified a unique subset of fetal heart rate variability measures reflecting 1.5 days ahead of time the levels of macrophage activation and increased leakiness in terminal ileum. We propose that such subset of fetal heart rate variability measures reflects brain-gut communication via the vagus nerve. Detecting such noninvasively obtainable organ-specific fetal heart rate variability signature of inflammation would alarm neonatologists about neonates at risk of developing necrotizing enterocolitis and sepsis. Clinical validation studies are required.


Assuntos
Corioamnionite , Enterocolite Necrosante/diagnóstico , Frequência Cardíaca Fetal , Animais , Cardiotocografia , Corioamnionite/induzido quimicamente , Corioamnionite/imunologia , Citocinas/sangue , Citocinas/metabolismo , Modelos Animais de Doenças , Enterocolite Necrosante/etiologia , Enterocolite Necrosante/fisiopatologia , Feminino , Humanos , Íleo/patologia , Recém-Nascido , Lipopolissacarídeos , Ativação de Macrófagos , Gravidez , Estudos Prospectivos , Ovinos
15.
Can Vet J ; 57(3): 289-92, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26933266

RESUMO

This study describes a safe, reliable, and accessible means to measure heart rate (HR) and HR variability (HRV) and evaluates the use of HRV as a physiological correlate of stress in the Asian elephant. A probabilistic model indicates that HRV measurements may adequately distinguish between stressed and non-stressed elephants.


Variabilité de la fréquence cardiaque en relation avec le stress chez un éléphant d'Asie(Elephas maximus). Cette étude décrit un moyen sûr, fiable et accessible de mesurer la fréquence cardiaque (FC) et la variabilité de la FC (VFC) et évalue l'utilisation de la VFC comme corrélat physiologique du stress chez l'éléphant d'Asie. Un modèle probabiliste indique que les mesures de la VFC peuvent adéquatement distinguer entre des éléphants stressés et non stressés.(Traduit par Isabelle Vallières).


Assuntos
Elefantes/fisiologia , Determinação da Frequência Cardíaca/veterinária , Frequência Cardíaca , Estresse Fisiológico , Animais , Eletrodos/veterinária , Feminino , Determinação da Frequência Cardíaca/métodos , Masculino , Valores de Referência
16.
Crit Care ; 18(2): R65, 2014 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-24713049

RESUMO

INTRODUCTION: Prolonged ventilation and failed extubation are associated with increased harm and cost. The added value of heart and respiratory rate variability (HRV and RRV) during spontaneous breathing trials (SBTs) to predict extubation failure remains unknown. METHODS: We enrolled 721 patients in a multicenter (12 sites), prospective, observational study, evaluating clinical estimates of risk of extubation failure, physiologic measures recorded during SBTs, HRV and RRV recorded before and during the last SBT prior to extubation, and extubation outcomes. We excluded 287 patients because of protocol or technical violations, or poor data quality. Measures of variability (97 HRV, 82 RRV) were calculated from electrocardiogram and capnography waveforms followed by automated cleaning and variability analysis using Continuous Individualized Multiorgan Variability Analysis (CIMVA™) software. Repeated randomized subsampling with training, validation, and testing were used to derive and compare predictive models. RESULTS: Of 434 patients with high-quality data, 51 (12%) failed extubation. Two HRV and eight RRV measures showed statistically significant association with extubation failure (P <0.0041, 5% false discovery rate). An ensemble average of five univariate logistic regression models using RRV during SBT, yielding a probability of extubation failure (called WAVE score), demonstrated optimal predictive capacity. With repeated random subsampling and testing, the model showed mean receiver operating characteristic area under the curve (ROC AUC) of 0.69, higher than heart rate (0.51), rapid shallow breathing index (RBSI; 0.61) and respiratory rate (0.63). After deriving a WAVE model based on all data, training-set performance demonstrated that the model increased its predictive power when applied to patients conventionally considered high risk: a WAVE score >0.5 in patients with RSBI >105 and perceived high risk of failure yielded a fold increase in risk of extubation failure of 3.0 (95% confidence interval (CI) 1.2 to 5.2) and 3.5 (95% CI 1.9 to 5.4), respectively. CONCLUSIONS: Altered HRV and RRV (during the SBT prior to extubation) are significantly associated with extubation failure. A predictive model using RRV during the last SBT provided optimal accuracy of prediction in all patients, with improved accuracy when combined with clinical impression or RSBI. This model requires a validation cohort to evaluate accuracy and generalizability. TRIAL REGISTRATION: ClinicalTrials.gov NCT01237886. Registered 13 October 2010.


Assuntos
Extubação/tendências , Estado Terminal/terapia , Frequência Cardíaca/fisiologia , Taxa Respiratória/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
17.
Eur J Appl Physiol ; 114(10): 2119-28, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24957416

RESUMO

PURPOSE: We evaluated the changes in core temperature, heart rate, and heart rate variability (HRV) during the induction and decay of heat acclimation. METHODS: Ten males (23 ± 3 years; 79.5 ± 3.5 kg; 15.2 ± 4.5 percent body fat; 51.13 ± 4.61 mLO(2)∙kg(-1)∙min(-1) peak oxygen uptake) underwent a 14-day heat acclimation protocol comprising of 90-min cycling at ~50 % peak oxygen uptake at 40 °C and ~20 % relative humidity. Core temperature, heart rate, and 102 HRV measures were recorded during a heat tolerance test conducted at baseline (day 0) and at the end of the induction (day 14) and decay (day 28) phases. RESULTS: Heat acclimation resulted in significantly reduced core temperature [rectal (χ (2) = 1298.14, p < 0.001); esophageal (χ (2) = 1069.88, p < 0.001)] and heart rate (χ (2) = 1230.17, p < 0.001). Following the decay phase, 26, 40, and 60 % of the heat acclimation-induced reductions in rectal temperature, esophageal temperature, and heart rate, respectively, were lost. Heat acclimation was accompanied by profound and broad changes in HRV: at the end of the induction phase, 75 of the 102 variability measures computed were significantly different (p < 0.001), compared to only 47 of the 102 at the end of the decay phase. CONCLUSIONS: Heat acclimation is accompanied by reduced core temperature, significant bradycardia, and marked alterations in HRV, which we interpret as being related to vagal dominance. The observed changes in core temperature persist for at least 2 weeks of non-exposure to heat, while the changes in heart rate and HRV decay faster and are only partly evident after 2 weeks of non-exposure to heat.


Assuntos
Aclimatação/fisiologia , Frequência Cardíaca , Temperatura Alta , Adulto , Temperatura Corporal , Humanos , Masculino
19.
Artigo em Inglês | MEDLINE | ID: mdl-39255520

RESUMO

Heart rate variability (HRV) has shown potential as a tool for monitoring thermal strain, but there is limited data to support its efficacy in older adults during prolonged heat exposures. We compared HRV between young (19-31 years, n=20) and older (61-78 years, n=39) adults during 9 hours of heat exposure (40°C, 9% RH). We also explored whether heart rate (HR) and/or HRV could be used to distinguish older adults who achieved elevated thermal strain, defined as either 1) an increase in core temperature >1.0°C (occurring in 39% [15/39]) or 2) a reduction in systolic blood pressure >10 mm Hg (occurring in 67% [26/39]). Percentage of age-predicted maximal HR and percentage of heart rate reserve (HRR) were higher, whereas standard deviation of normal RR intervals (SDNN), the square root of the mean of squared differences between successive RR intervals (RMSSD), high frequency power (HF), and cardiac vagal index (CVI) were lower in older compared to young adults (P≤0.004) during heat exposure. In older adults, increases in core temperature were correlated with percentage of age-predicted maximal HR, percentage of HRR, RMSSD, and CVI (P≤0.031), whereas changes in systolic blood pressure were not significantly associated with HR or HRV indices (P≤0.327). Receiver operating characteristic curve analysis indicated that HR and HRV indices had generally poor ability to identify older adults with elevated thermal strain (area under the curve ≤0.65). Age-related differences in HRV, consistent with vagal withdrawal among older adults, remained during daylong heat exposure, but marked heterogeneity of response likely contributed to HRV providing limited discriminatory value in identifying changes in core temperature or blood pressure in older adults.

20.
Appl Physiol Nutr Metab ; 48(11): 863-869, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37556854

RESUMO

TAKE-HOME MESSAGE: During short bouts of light-to-vigorous exercise in the heat, controlled and uncomplicated hypertension did not significantly modulate HRV in physically active individuals. These findings can be used to refine guidance on use of exercise for hypertension management in the heat.


Assuntos
Transtornos de Estresse por Calor , Hipertensão , Humanos , Frequência Cardíaca , Coração , Hipertensão/terapia , Sistema Nervoso Autônomo , Resposta ao Choque Térmico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA