Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Sep Sci ; 46(17): e2300137, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37449340

RESUMO

Froth treatment tailings are one type of waste stream generated during the extraction of surface-mined oil sands bitumen. To remove water and solids from bitumen froth recovered during the water-based extraction process, hydrocarbon diluent is added, and settling and/or centrifugation are applied to the diluted bitumen froth, producing diluted bitumen and froth treatment tailings. While recovery processes are in place to remove and recycle the diluent from froth treatment tailings, some residual diluent can remain. Since tailings are stored in outdoor ponds, the residual diluent can have implications for methanogenic microbial processes and resulting greenhouse gas emissions. This work presents a methodology to accurately extract and quantify diluent hydrocarbons from froth treatment tailings using gas chromatography. A cold-start temperature program is used to separate diluent hydrocarbons from any residual bitumen in the sample, and diluent is quantified using commercial standards as well as unprocessed diluent. A series of extraction parameters were tested and results from multiple conditions are shown with a rationale for the selected optimized parameters. Quantification of diluent in tailings samples is demonstrated from 60 to 5329 µg/g, and results from quality control standards show an average diluent recovery of 100 ± 10%.

2.
J Sep Sci ; 37(24): 3649-55, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25311312

RESUMO

Two-dimensional heart-cutting gas chromatography is used to analyze dissolved hydrogen sulfide in crude samples. Liquid samples are separated first on an HP-PONA column, and the light sulfur gases are heart-cut to a GasPro column, where hydrogen sulfide is separated from other light sulfur gases and detected with a sulfur chemiluminescence detector. Heart-cutting is accomplished with the use of a Deans switch. Backflushing the columns after hydrogen sulfide detection eliminates any problems caused by high-boiling hydrocarbons in the samples. Dissolved hydrogen sulfide is quantified in 14 crude oil samples, and the results are shown in this work. The method is also applicable to the analysis of headspace hydrogen sulfide over crude oil samples. Gas hydrogen sulfide measurements are compared to liquid hydrogen sulfide measurements for the same sample set. The chromatographic system design is discussed, and chromatograms of representative gas and liquid measurements are shown.

3.
Energy Fuels ; 38(8): 6753-6763, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38654763

RESUMO

The comprehensive chemical characterization of crude oil is important for the evaluation of the transformation and fate of components in the environment. Molecular-level speciation of naphthenic acid fraction compounds (NAFCs) was investigated in a mesoscale spill tank using both negative-ion electrospray ionization (ESI) Orbitrap mass spectrometry (MS) and positive-ion atmospheric pressure photoionization Fourier transform ion cyclotron resonance mass spectrometry (APPI-FT-ICR-MS). Both ionization techniques are coupled to high-resolution mass spectrometric detectors (ESI: Orbitrap MS; APPI: FT-ICR-MS at 9.4 T), enabling insight into the behavior and fate of petrogenic compounds during a simulated freshwater crude oil spill. Negative-ion ESI Orbitrap-MS reveals that oxygen-containing (Ox) classes are detected early in the spill, whereby species with more oxygen per molecule evolve later in the simulated spill. The O2-containing species gradually decreased in relative abundance, while O3 and O4 species increased in relative abundance throughout the simulated spill, which could correspond to a relative degree of oxygen incorporation. Nonpolar speciation by positive-ion APPI 9.4 T FT-ICR-MS allowed for the identification of water-soluble nonpolar and less polar acidic species. Molecular-level graphical representation of elemental compositions derived from simulated spill water-soluble and oil-soluble species suggest that biological activity is the primary degradation mechanism and that biodegradation was the dominant mechanism based on the negative-ion ESI Orbitrap-MS results.

4.
Chemosphere ; 292: 133415, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34953875

RESUMO

Negative ion electrospray Orbitrap mass spectrometry was used to analyze water samples taken from a pilot-scale spill tank test of conventional crude oil on freshwater. A 56-day spill test was performed, and water samples were taken at regular intervals throughout the test to determine what changes in water chemistry occur with time. Orbitrap mass spectrometry was used to measure oxidized species in water samples, and oxidized species are analyzed by carbon number, double bond equivalent and hydrocarbon class. Emphasis is placed on changes with time over the course of the spill test, to examine changes by weathering processes that could occur naturally in a field spill scenario. Results demonstrate that while the concentrations of polycyclic aromatic hydrocarbons decrease in the water phase over time, the concentrations of total organic carbon and oxidized species in the water increase with time, where quantities of O2 and O3 species have the highest abundance. Measurement of increasing concentrations and changing relative abundances of these oxidized compounds can be used to assess how oil behaves in a freshwater aquatic environment after a spill.


Assuntos
Poluição por Petróleo , Petróleo , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Água Doce , Hidrocarbonetos , Espectrometria de Massas , Poluição por Petróleo/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Poluentes Químicos da Água/análise
5.
J Hazard Mater ; 440: 129798, 2022 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-36027751

RESUMO

With the increasing use of unconventional, heavy crude oils there is growing interest in potential impacts of a diluted bitumen (DB) spill in marine and freshwater environments. DB has the potential to release several toxic, trace organic contaminants to the water column. Here, the aqueous concentrations and compositions of two classes of organic contaminants, naphthenic acids (NAs) and polycyclic aromatic hydrocarbons (PAHs), are followed over 8 weeks after a simulated spill of DB (10 L) into a freshwater mesocosm (1200 L) with river sediment (2.4 kg). These complex samples contain biogenic dissolved organic matter, inorganic ions, petroleum contaminants, suspended sediments, and oil droplets. We report the first use of condensed phase membrane introduction mass spectrometry (CP-MIMS) as a direct sampling platform in a complex multi-phase mesocosm spill tank study to measure trace aqueous phase contaminants with little to no sample preparation (dilution and/or pH adjustment). CP-MIMS provides complementary strengths to conventional analytical approaches (e.g., gas- or liquid chromatography mass spectrometry) by allowing the entire sample series to be screened quickly. Trace NAs are measured as carboxylates ([M-H]-) using electrospray ionization and PAHs are detected as radical cations (M+•) using liquid electron ionization coupled to a triple quadrupole mass spectrometer. The DB-affected mesocosm exhibits NA concentrations from 0.3 to 1.2 mg/L, which rise quickly over the first 2 - 5 days , then decrease slowly over the remainder of the study period. The NA profile (measured as the full scan in negative-electrospray ionization at nominal mass resolution) shifts to lower m/z with weathering, a process followed by principal component analysis of the normalized mass spectra. We couple CP-MIMS with high-resolution mass spectrometry to follow changes in molecular speciation over time, which reveals a concomitant shift from classical 'O2' naphthenic acids to more oxidized analogues. Concentrations of PAHs and alkylated analogues (C1 - C4) in the DB-affected water range from 0 to 5 µg/L. Changes in PAH concentrations depend on ring number and degree of alkylation, with small and/or lightly alkylated (C0 - C2) PAH concentrations rising to a maximum in the first 4 - 8 days (100 - 200 h) before slowly decaying over the remainder of the study period. Larger and heavily alkylated (C3 - C4) PAH concentrations generally rise slower, with some species remaining below the detection limit throughout the study period (e.g., C20H12 class including benzo[a]pyrene). In contrast, a control mesocosm (without oil) exhibited NA concentrations below 0.05 mg/L and PAHs were below detection limit. Capitalizing on the rapid analytical workflow of CP-MIMS, we also investigate the impacts of sample filtration at the time of sampling (on NA and PAH data) and sample storage time (on NA data only).


Assuntos
Petróleo , Hidrocarbonetos Policíclicos Aromáticos , Benzo(a)pireno , Ácidos Carboxílicos , Hidrocarbonetos , Espectrometria de Massas/métodos , Petróleo/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Água/química
6.
Microorganisms ; 9(5)2021 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-34069522

RESUMO

In Alberta's Athabasca oil sands region (AOSR), over 1.25 billion m3 of tailings waste from the bitumen extraction process are stored in tailings ponds. Fugitive emissions associated with residual hydrocarbons in tailings ponds pose an environmental concern and include greenhouse gases (GHGs), reduced sulphur compounds (RSCs), and volatile organic compounds (VOCs). Froth treatment tailings (FTT) are a specific type of tailings waste stream from the bitumen froth treatment process that contains bioavailable diluent: either naphtha or paraffins. Tailings ponds that receive FTT are associated with the highest levels of biogenic gas production, as diverse microbial communities biodegrade the residual diluent. In this review, current literature regarding the composition, chemical analysis, and microbial degradation of FTT and its constituents is presented in order to provide a more complete understanding of the complex chemistry and biological processes related to fugitive emissions from tailings ponds receiving FTT. Characterizing the composition and biodegradation of FTT is important from an environmental perspective to better predict emissions from tailings ponds and guide tailings pond management decisions.

7.
J Chromatogr A ; 1530: 241-246, 2017 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-29128094

RESUMO

A modification to American Society for Testing and Materials (ASTM) method D5623 is proposed to enable successful and repeatable analysis of heavy crude oil samples. A two-dimensional gas chromatography configuration was implemented, with separation of sulphur compounds occurring on two columns. A Deans switch is used to enable heart-cutting of volatile sulphur compounds onto a DB-Sulfur stationary phase, and separation occurs concurrently with the backflushing of the primary column. The use of a sulphur-selective detector increases selectivity, and 22 volatile sulphur species are quantified in less than 15min, which is almost half the time of the original ASTM method. Samples ranging from light distillation cuts to whole crudes (boiling from 100°C to >750°C) were analyzed with minimal sample preparation. The calculated limit of detection was 0.7mg/kg, repeatability was 3% relative standard deviation (RSD), and a linear range of 1-250mg/kg was obtained, with an R2 value of 0.994 or better, depending on the compound.


Assuntos
Cromatografia Gasosa/métodos , Microfluídica/métodos , Petróleo/análise , Compostos de Enxofre/análise , Compostos de Enxofre/química , Calibragem , Limite de Detecção
8.
J Chromatogr A ; 1437: 191-202, 2016 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-26879453

RESUMO

Information on the sulfur classes present in petroleum is a key factor in determining the value of refined products and processing behavior in the refinery. A large part of the sulfur present is included in polycyclic aromatic sulfur heterocycles (PASHs), which in turn are difficult to desulfurize. Furthermore, some PASHs are potentially more mutagenic and carcinogenic than polycyclic aromatic hydrocarbons, PAHs. All of this calls for improved methods for the identification and quantification of individual sulfur species. Recent advances in analytical techniques such as comprehensive two-dimensional gas chromatography (GC×GC) have enabled the identification of many individual sulfur species. However, full identification of individual components, particularly in virgin oil fractions, is still out of reach as standards for numerous compounds are unavailable. In this work, a method for accurately predicting retention times in GC×GC using a QSRR (quantitative structure retention relationship) method was very helpful for the identification of individual sulfur compounds. Retention times for 89 saturated, aromatic, and polyaromatic sulfur-containing heterocyclic compounds were determined using two-dimensional gas chromatography. These retention data were correlated with molecular descriptors generated with CODESSA software. Two independent QSRR relationships were derived for the primary as well as the secondary retention characteristics. The predictive ability of the relationships was tested by using both independent sets of compounds and a cross-validation technique. When the corresponding chemical standards are unavailable, the equations developed for predicting retention times can be used to identify unknown chromatographic peaks by matching their retention times with those of sulfur compounds of known molecular structure.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Gasosa , Petróleo/análise , Hidrocarbonetos Policíclicos Aromáticos/análise , Enxofre/química , Compostos Heterocíclicos/análise , Compostos Heterocíclicos/química , Estrutura Molecular , Compostos de Enxofre/análise
9.
J Vis Exp ; (115)2016 09 02.
Artigo em Inglês | MEDLINE | ID: mdl-27684325

RESUMO

The work is based on a reported study which investigates the processability of canola oil (bio-feed) in the presence of bitumen-derived heavy gas oil (HGO) for production of transportation fuels through a fluid catalytic cracking (FCC) route. Cracking experiments are performed with a fully automated reaction unit at a fixed weight hourly space velocity (WHSV) of 8 hr(-1), 490-530 °C, and catalyst/oil ratios of 4-12 g/g. When a feed is in contact with catalyst in the fluid-bed reactor, cracking takes place generating gaseous, liquid, and solid products. The vapor produced is condensed and collected in a liquid receiver at -15 °C. The non-condensable effluent is first directed to a vessel and is sent, after homogenization, to an on-line gas chromatograph (GC) for refinery gas analysis. The coke deposited on the catalyst is determined in situ by burning the spent catalyst in air at high temperatures. Levels of CO2 are measured quantitatively via an infrared (IR) cell, and are converted to coke yield. Liquid samples in the receivers are analyzed by GC for simulated distillation to determine the amounts in different boiling ranges, i.e., IBP-221 °C (gasoline), 221-343 °C (light cycle oil), and 343 °C+ (heavy cycle oil). Cracking of a feed containing canola oil generates water, which appears at the bottom of a liquid receiver and on its inner wall. Recovery of water on the wall is achieved through washing with methanol followed by Karl Fischer titration for water content. Basic results reported include conversion (the portion of the feed converted to gas and liquid product with a boiling point below 221 °C, coke, and water, if present) and yields of dry gas (H2-C2's, CO, and CO2), liquefied petroleum gas (C3-C4), gasoline, light cycle oil, heavy cycle oil, coke, and water, if present.


Assuntos
Biocombustíveis , Catálise , Automação , Dióxido de Carbono , Gases , Temperatura Alta , Resíduos Industriais , Óleos de Plantas , Óleo de Brassica napus , Água
10.
J Vis Exp ; (106): e53416, 2015 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-26709594

RESUMO

A method for the analysis of dissolved hydrogen sulfide in crude oil samples is demonstrated using gas chromatography. In order to effectively eliminate interferences, a two dimensional column configuration is used, with a Deans switch employed to transfer hydrogen sulfide from the first to the second column (heart-cutting). Liquid crude samples are first separated on a dimethylpolysiloxane column, and light gases are heart-cut and further separated on a bonded porous layer open tubular (PLOT) column that is able to separate hydrogen sulfide from other light sulfur species. Hydrogen sulfide is then detected with a sulfur chemiluminescence detector, adding an additional layer of selectivity. Following separation and detection of hydrogen sulfide, the system is backflushed to remove the high-boiling hydrocarbons present in the crude samples and to preserve chromatographic integrity. Dissolved hydrogen sulfide has been quantified in liquid samples from 1.1 to 500 ppm, demonstrating wide applicability to a range of samples. The method has also been successfully applied for the analysis of gas samples from crude oil headspace and process gas bags, with measurement from 0.7 to 9,700 ppm hydrogen sulfide.


Assuntos
Cromatografia Gasosa/métodos , Sulfeto de Hidrogênio/análise , Petróleo/análise , Enxofre/análise , Gases/análise , Hidrocarbonetos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA