Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Eur Heart J ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39212387

RESUMO

BACKGROUND AND AIMS: Severe tricuspid regurgitation (TR) is associated with increased mortality rates, but benefit of its correction and ideal timing are not clearly determined. This study aimed to identify patient subsets who might benefit from surgery. METHODS: In TRIGISTRY, an international cohort study of consecutive patients with severe isolated functional TR (33 centers, 10 countries), survival rates up to 10 years were compared between patients who underwent isolated tricuspid valve (TV) surgery (repair or replacement) and those conservatively managed, overall and according to TRI-SCORE category (low: ≤3, intermediate: 4-5, high: ≥6). RESULTS: 1,217 were managed conservatively, and 551 underwent isolated TV surgery (200 repairs, 351 replacements). TRI-SCORE distribution was 33% low, 32% intermediate, and 35% high. At 10 years, survival rates were similar between surgical and conservative management (41% vs. 36%; hazard ratio [HR] 0.97; 95% confidence interval [CI] 0.88-1.08, P=0.57). Surgery improved survival compared to conservative management in the low TRI-SCORE category (72% vs. 44%; HR 0.27; 95% CI 0.20-0.37, P<0.0001), but not in the intermediate (36% vs. 37%, HR 1.17; 95%CI 0.98-1.40, P=0.09) or high categories (20% vs. 24%; HR 1.06; 95% CI 0.91-1.25, P=0.45). Both repair and replacement improved survival in the low TRI-SCORE category (84% and 61% vs. 44%; HR 0.11; 95% CI 0.06-0.19, P<0.0001, and HR 0.65; 95% CI 0.47-0.90, P=0.009). Repair showed benefit in the intermediate category (59% vs. 37%; HR 0.49; 95% CI 0.35-0.68, P<0.0001) while replacement was possibly harmful (25% vs. 37%; HR 1.43; 95% CI 1.18-1.72, P=0.0002). CONCLUSIONS: Higher survival rates were observed with repair than replacement and benefit of intervention declined as TRI-SCORE increased with no benefit of any type of surgery in the high TRI-SCORE category. These results emphasize the importance of timely intervention and patient selection to achieve the best outcomes and the need for randomized controlled trials. TRIAL REGISTRATION: TRIGISTRY: ClinicalTrials.gov, NCT05825898.

2.
Europace ; 26(10)2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39255332

RESUMO

AIMS: Both isolated thoracoscopic and hybrid thoracoscopic atrial fibrillation (AF) ablation techniques have demonstrated favourable outcomes in the management of patients with (long-standing) persistent AF, as compared with catheter ablation. However, it is currently unknown whether there is a difference in short- and long-term outcomes when comparing these two minimally invasive surgical AF ablation procedures. Therefore, a systematic review and meta-analysis were performed to investigate these two techniques, with a specific emphasis on long-term freedom from atrial tachyarrhythmias (ATAs). METHODS AND RESULTS: A systematic search through PubMed, EMBASE, and the Cochrane Library databases was performed. All studies reporting on short-term outcomes were included in the meta-analysis. A pooled analysis of long-term freedom from ATA was performed based on Kaplan-Meier (KM) curve-derived individual patient data. Reconstructed individual time-to-event data were analysed in a multivariable Cox frailty model with adjustments for age, sex, type of AF, duration of AF history, and study variable (frailty term in the frailty Cox model). In total, 53 studies were included in the meta-analysis, encompassing 4950 patients. There were no differences in major short-term outcomes (mortality or stroke) between isolated thoracoscopic and hybrid thoracoscopic ablation. A total of 18 studies reported KM curves for long-term freedom from ATA, comprising 2038 patients. Adjusted analysis revealed that hybrid ablation was significantly associated with greater freedom from ATA [adjusted hazard ratio (aHR) = 0.59, 95% confidence interval (CI): 0.43-0.83, P < 0.001] compared with isolated thoracoscopic ablation. Additionally, older age (aHR = 1.07, 95% CI: 1.03-1.12, P = 0.002) and a higher percentage of male patients (aHR = 1.02, 95% CI: 1.01-1.03, P < 0.001) were significantly associated with lower long-term freedom from ATA recurrence. CONCLUSION: Hybrid thoracoscopic AF ablation is associated with a greater long-term freedom from ATA when compared with isolated thoracoscopic ablation, without differences in complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Toracoscopia , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Humanos , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Toracoscopia/métodos , Toracoscopia/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Masculino , Feminino , Recidiva , Pessoa de Meia-Idade , Idoso
3.
Crit Care ; 28(1): 217, 2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38961495

RESUMO

BACKGROUND: The outcomes of several randomized trials on extracorporeal cardiopulmonary resuscitation (ECPR) in patients with refractory out-of-hospital cardiac arrest were examined using frequentist methods, resulting in a dichotomous interpretation of results based on p-values rather than in the probability of clinically relevant treatment effects. To determine such a probability of a clinically relevant ECPR-based treatment effect on neurological outcomes, the authors of these trials performed a Bayesian meta-analysis of the totality of randomized ECPR evidence. METHODS: A systematic search was applied to three electronic databases. Randomized trials that compared ECPR-based treatment with conventional CPR for refractory out-of-hospital cardiac arrest were included. The study was preregistered in INPLASY (INPLASY2023120060). The primary Bayesian hierarchical meta-analysis estimated the difference in 6-month neurologically favorable survival in patients with all rhythms, and a secondary analysis assessed this difference in patients with shockable rhythms (Bayesian hierarchical random-effects model). Primary Bayesian analyses were performed under vague priors. Outcomes were formulated as estimated median relative risks, mean absolute risk differences, and numbers needed to treat with corresponding 95% credible intervals (CrIs). The posterior probabilities of various clinically relevant absolute risk difference thresholds were estimated. RESULTS: Three randomized trials were included in the analysis (ECPR, n = 209 patients; conventional CPR, n = 211 patients). The estimated median relative risk of ECPR for 6-month neurologically favorable survival was 1.47 (95%CrI 0.73-3.32) with a mean absolute risk difference of 8.7% (- 5.0; 42.7%) in patients with all rhythms, and the median relative risk was 1.54 (95%CrI 0.79-3.71) with a mean absolute risk difference of 10.8% (95%CrI - 4.2; 73.9%) in patients with shockable rhythms. The posterior probabilities of an absolute risk difference > 0% and > 5% were 91.0% and 71.1% in patients with all rhythms and 92.4% and 75.8% in patients with shockable rhythms, respectively. CONCLUSION: The current Bayesian meta-analysis found a 71.1% and 75.8% posterior probability of a clinically relevant ECPR-based treatment effect on 6-month neurologically favorable survival in patients with all rhythms and shockable rhythms. These results must be interpreted within the context of the reported credible intervals and varying designs of the randomized trials. REGISTRATION: INPLASY (INPLASY2023120060, December 14th, 2023, https://doi.org/10.37766/inplasy2023.12.0060 ).


Assuntos
Teorema de Bayes , Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/terapia , Parada Cardíaca Extra-Hospitalar/mortalidade , Reanimação Cardiopulmonar/métodos , Reanimação Cardiopulmonar/normas , Oxigenação por Membrana Extracorpórea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Resultado do Tratamento
4.
Eur Heart J ; 44(41): 4357-4372, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37638786

RESUMO

BACKGROUND AND AIMS: The current study proposes a novel volume-outcome (V-O) meta-analytical approach to determine the optimal annual hospital case volume threshold for cardiovascular interventions in need of centralization. This novel method is applied to surgery for acute type A aortic dissection (ATAAD) as an illustrative example. METHODS: A systematic search was applied to three electronic databases (1 January 2012 to 29 March 2023). The primary outcome was early mortality in relation to annual hospital case volume. Data were presented by volume quartiles (Qs). Restricted cubic splines were used to demonstrate the V-O relation, and the elbow method was applied to determine the optimal case volume. For clinical interpretation, numbers needed to treat (NNTs) were calculated. RESULTS: One hundred and forty studies were included, comprising 38 276 patients. A significant non-linear V-O effect was observed (P < .001), with a notable between-quartile difference in early mortality rate [10.3% (Q4) vs. 16.2% (Q1)]. The optimal annual case volume was determined at 38 cases/year [95% confidence interval (CI) 37-40 cases/year, NNT to save a life in a centre with the optimal volume vs. 10 cases/year = 21]. More pronounced between-quartile survival differences were observed for long-term survival [10-year survival (Q4) 69% vs. (Q1) 51%, P < .01, adjusted hazard ratio 0.83, 95% CI 0.75-0.91 per quartile, NNT to save a life in a high-volume (Q4) vs. low-volume centre (Q1) = 6]. CONCLUSIONS: Using this novel approach, the optimal hospital case volume threshold was statistically determined. Centralization of ATAAD care to high-volume centres may lead to improved outcomes. This method can be applied to various other cardiovascular procedures requiring centralization.


Assuntos
Dissecção Aórtica , Hospitais com Alto Volume de Atendimentos , Humanos , Resultado do Tratamento , Dissecção Aórtica/cirurgia , Estudos Retrospectivos
5.
Eur Heart J ; 44(2): 100-112, 2023 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-36337034

RESUMO

The use of biomarkers is undisputed in the diagnosis of primary myocardial infarction (MI), but their value for identifying MI is less well studied in the postoperative phase following coronary artery bypass grafting (CABG). To identify patients with periprocedural MI (PMI), several conflicting definitions of PMI have been proposed, relying either on cardiac troponin (cTn) or the MB isoenzyme of creatine kinase, with or without supporting evidence of ischaemia. However, CABG inherently induces the release of cardiac biomarkers, as reflected by significant cTn concentrations in patients with uncomplicated postoperative courses. Still, the underlying (patho)physiological release mechanisms of cTn are incompletely understood, complicating adequate interpretation of postoperative increases in cTn concentrations. Therefore, the aim of the current review is to present these potential underlying mechanisms of cTn release in general, and following CABG in particular (Graphical Abstract). Based on these mechanisms, dissimilarities in the release of cTnI and cTnT are discussed, with potentially important implications for clinical practice. Consequently, currently proposed cTn biomarker cut-offs by the prevailing definitions of PMI might warrant re-assessment, with differentiation in cut-offs for the separate available assays and surgical strategies. To resolve these issues, future prospective studies are warranted to determine the prognostic influence of biomarker release in general and PMI in particular.


Assuntos
Ponte de Artéria Coronária , Infarto do Miocárdio , Humanos , Ponte de Artéria Coronária/efeitos adversos , Infarto do Miocárdio/etiologia , Troponina I , Troponina T , Biomarcadores
6.
Clin Chem ; 68(12): 1564-1575, 2022 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-36366960

RESUMO

BACKGROUND: Cardiac troponin I and T are both used for diagnosing myocardial infarction (MI) after coronary artery bypass grafting (CABG), also known as type 5 MI (MI-5). Different MI-5 definitions have been formulated, using multiples of the 99th percentile upper reference limit (10×, 35×, or 70× URL), with or without supporting evidence. These definitions are arbitrarily chosen based on conventional assays and do not differentiate between troponin I and T. We therefore investigated the kinetics of high-sensitivity cardiac troponin I (hs-cTnI) and T (hs-cTnT) following CABG. METHODS: A systematic search was applied to MEDLINE and EMBASE databases including the search terms "coronary artery bypass grafting" AND "high-sensitivity cardiac troponin." Studies reporting hs-cTnI or hs-cTnT on at least 2 different time points were included. Troponin concentrations were extracted and normalized to the assay-specific URL. RESULTS: For hs-cTnI and hs-cTnT, 17 (n = 1661 patients) and 15 studies (n = 2646 patients) were included, respectively. Preoperative hs-cTnI was 6.1× URL (95% confidence intervals: 4.9-7.2) and hs-cTnT 1.2× URL (0.9-1.4). Mean peak was reached 6-8 h postoperatively (126× URL, 99-153 and 45× URL, 29-61, respectively). Subanalysis of hs-cTnI illustrated assay-specific peak heights and kinetics, while subanalysis of surgical strategies revealed 3-fold higher hs-cTnI than hs-cTnT for on-pump CABG and 5-fold for off-pump CABG. CONCLUSION: Postoperative hs-cTnI and hs-cTnT following CABG surpass most current diagnostic cutoff values. hs-cTnI was almost 3-fold higher than hs-cTnT, and appeared to be highly dependent on the assay used and surgical strategy. There is a need for assay-specific hs-cTnI and hs-cTnT cutoff values for accurate, timely identification of MI-5.


Assuntos
Infarto do Miocárdio , Troponina I , Humanos , Troponina T , Ponte de Artéria Coronária , Infarto do Miocárdio/diagnóstico , Bioensaio , Biomarcadores
7.
Eur J Vasc Endovasc Surg ; 63(5): 674-687, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35379543

RESUMO

OBJECTIVE: The extent of aortic replacement during surgery for acute type A aortic dissection (ATAAD) is an important matter of debate. This meta-analysis aimed to evaluate the short and long term outcomes of a proximal aortic repair (PAR) vs. total arch replacement (TAR) in the treatment of ATAAD. DATA SOURCES: A systematic search of PubMed and Embase was performed. Studies comparing PAR to TAR for ATAAD were included. REVIEW METHODS: The primary outcomes were early death and long term actuarial survival at one, five, and 10 years. Random effects models in conjunction with relative risks (RRs) were used for meta-analyses. RESULTS: Nineteen studies were included, comprising 5 744 patients (proximal: n = 4 208; total arch: n = 1 536). PAR was associated with reduced early mortality (10.8% [95% confidence interval (CI) 8.4 - 13.7] vs. 14.0% [95% CI 10.4 - 18.7]; RR 0.73 [95% CI 0.63 - 0.85]) and reduced post-operative renal failure (10.4% [95% CI 7.2 - 14.8] vs. 11.1% [95% CI 6.7 - 17.5]; RR 0.77 [95% CI 0.66 - 0.90]), but there was no difference in stroke (8.0% [95% CI 5.9 - 10.7] vs. 7.3% [95% CI 4.6 - 11.3]; RR 0.87 [95% CI 0.69 - 1.10]). No statistically significant difference was found for survival after one year (83.2% [95% CI 77.5 - 87.7] vs. 78.6% [95% CI 69.7 - 85.5]; RR 1.05 [95% CI 0.99 - 1.11]), which persisted after five years (75.4% [95% CI 71.2 - 79.2] vs. 74.5% [95% CI 64.7 - 82.3]; RR 1.02 [95% CI 0.91 - 1.14]). After 10 years, there was a significant survival benefit for patients who underwent TAR (64.7% [95% CI 61.1 - 68.1] vs. 72.4% [95% CI 67.5 - 76.7]; RR 0.91 [95% CI 0.84 - 0.99]). CONCLUSION: PAR appears to lead to an improved early mortality rate and a reduced complication rate. In the current meta-analysis, the suggestion of an improved 10 year survival benefit of TAR was found, which should be interpreted in the context of potential confounders such as age at presentation, comorbidities, and haemodynamic stability. In any case, PAR seems to be intuitive in older patients with limited dissections, and in those presenting in less stable conditions.

8.
Artif Organs ; 46(3): 349-361, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34494291

RESUMO

In-hospital mortality of adult veno-venous extracorporeal membrane oxygenation (V-V ECMO) patients remains invariably high. However, little is known regarding timing and causes of in-hospital death, either on-ECMO or after weaning. The current review aims to investigate the timing and causes of death of adult patients during hospital admittance for V-V ECMO, and to define the V-V ECMO gap, which is represented by the patients that are successfully weaned of ECMO but still die during hospital stay. A systematic search was performed using electronic MEDLINE and EMBASE databases through PubMed. Studies reporting on adult V-V ECMO patients from January 2006 to December 2020 were screened. Studies that did not report on at least on-ECMO mortality and discharge rate were excluded from analysis as they could not provide the required information regarding the proposed V-V ECMO-gap. Mortality rates on-ECMO and after weaning, as well as weaning and discharge rates, were analyzed as primary outcomes. Secondary outcomes were the causes of death and complications. Initially, 35 studies were finally included in this review. Merely 24 of these studies (comprising 975 patients) reported on prespecified V-V ECMO outcomes (on-ECMO mortality and discharge rate). Mortality on V-V ECMO support was 27.8% (95% confidence interval (CI) 22.5%-33.2%), whereas mortality after successful weaning was 12.7% (95% CI 8.8%-16.6%, defining the V-V ECMO gap). 72.2% of patients (95% CI 66.8%-77.5%) were weaned successfully from support and 56.8% (95% CI 49.9%-63.8%) of patients were discharged from hospital. The most common causes of death on ECMO were multiple organ failure, bleeding, and sepsis. Most common causes of death after weaning were multiorgan failure and sepsis. Although the majority of patients are weaned successfully from V-V ECMO support, a significant proportion of subjects still die during hospital stay, defining the V-V ECMO gap. Overall, timing and causes of death are poorly reported in current literature. Future studies on V-V ECMO should describe morbidity and mortality outcomes in more detail in relation to the timing of the events, to improve patient management, due to enhanced understanding of the clinical course.


Assuntos
Causas de Morte , Oxigenação por Membrana Extracorpórea/mortalidade , Oxigenação por Membrana Extracorpórea/efeitos adversos , Hemorragia/mortalidade , Mortalidade Hospitalar , Hospitalização , Humanos , Insuficiência de Múltiplos Órgãos/mortalidade , Sepse/mortalidade
9.
J Card Surg ; 37(1): 162-164, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34689381

RESUMO

In the past few years, many have disputed the optimal biomarker for confirming or ruling out a diagnosis of periprocedural myocardial infarction (PMI) and the optimal cut-off concentrations to apply. In this issue of the Journal of Cardiac Surgery, Niclauss et al. performed a retrospective analysis of CK-MB and high-sensitivity cardiac troponin T (hs-cTnT) dynamics and peak concentrations following different cardiac surgical interventions in 400 patients during a 2-year period in a single center. The authors found that CK-MB and hs-cTnT predict PMI with a comparable diagnostic accuracy and discriminatory power >95%. They also attempted to propose an improved, more sensitive threshold of hs-cTnT for PMI. Their findings could have implications for clinical practice, but more research is warranted to identify more appropriate cut-offs. This could include hs-cTnT release pattern, slope steepness, and changes. Ultimately, this could results in patient-specific model, able to predict expected and abnormal ranges of hs-cTnT release, enabling an improved and timely diagnosis of PMI.


Assuntos
Infarto do Miocárdio , Troponina T , Biomarcadores , Creatina Quinase Forma MB , Humanos , Infarto do Miocárdio/diagnóstico , Estudos Retrospectivos
10.
J Card Surg ; 37(11): 3984-3987, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36047388

RESUMO

There are limits to the use of cardioplegic arrest during complex cardiac surgical procedures, especially in patients with severe left ventricular dysfunction. In the current report, we graphically present the detailed surgical strategy and technique for beating-heart aortic root replacement with concomitant coronary bypass grafting, for patients otherwise deemed inoperable. With support of cardiopulmonary bypass (CPB), beating-heart bypass surgery is realized, after which the bypass grafts can selectively be connected to the CPB, preserving coronary flow. Then, on the beating and perfused heart, a complex procedure such as aortic root replacement can be performed, without jeopardizing postoperative cardiac function. However, several important caveats and remarks regarding the use of beating-heart surgery should be considered, including: coronary perfusion verification and maintenance, temperature management, and prevention of air embolisms. By use of this strategy, risks associated with cardioplegic arrest are minimized, while it circumvents the potential need for long-term postoperative extracorporeal membrane oxygenation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Disfunção Ventricular Esquerda , Valva Aórtica , Ponte Cardiopulmonar/métodos , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA