Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Micromachines (Basel) ; 11(11)2020 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-33114617

RESUMO

The InAs/InAsSb (Gallium-free) type-II strained-layer superlattice (T2SLS) has emerged in the last decade as a viable infrared detector material with a continuously adjustable band gap capable of accommodating detector cutoff wavelengths ranging from 4 to 15 µm and beyond. When coupled with the unipolar barrier infrared detector architecture, the InAs/InAsSb T2SLS mid-wavelength infrared (MWIR) focal plane array (FPA) has demonstrated a significantly higher operating temperature than InSb FPA, a major incumbent technology. In this brief review paper, we describe the emergence of the InAs/InAsSb T2SLS infrared photodetector technology, point out its advantages and disadvantages, and survey its recent development.

2.
Appl Opt ; 46(33): 8202-10, 2007 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-18026560

RESUMO

The development of an interband cascade laser (ICL) based spectroscopic trace-gas sensor for the simultaneous detection of two atmospheric trace gases is reported. The sensor performance was evaluated using two ICLs capable of targeting formaldehyde (H2CO) and ethane (C2H6). Minimum detection limits of 3.5 ppbV for H2CO and 150 pptV for C2H6 was demonstrated with a 1 s integration time. The sensor was deployed for field measurements of H2CO, and laboratory quantification of both formaldehyde and ethane are reported. A cross comparison of the atmospheric concentration data for H2CO with data collected by a collocated commercial H2CO sensor employing Hantzsch reaction based fluorometric detection was performed. These results show excellent agreement between these two different approaches for trace-gas quantification. In addition, laboratory experiments for dual gas quantification show accurate, fast response with no crosstalk between the two gas channels.

3.
Appl Opt ; 45(6): 1275-87, 2006 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-16523793

RESUMO

Spectroscopic detection of gases can be achieved by measuring a few species-specific absorption lines, requiring very accurate wavelength control. Alternatively, it can be achieved by using many wavelengths spread over a wide range; each wavelength need not be optimal spectroscopically, but all collectively form a unique fingerprint for the species of interest. Statistical regression can be used to quantify their concentrations. An experimental evaluation of this concept involved using a 3.1 microm broadly tunable Sb-based mid-IR laser to discriminate and measure mixtures of acetylene and water vapor with absorption spectral overlaps. As many as 30 wavelengths from approximately 3200 to approximately 3280 cm-1 were used to measure 5 x 5 combinations of the two-gas concentration. Statistical analysis of the results validates the concept. Each gas concentration was consistently and reliably measured without any problem of interference from the other. In addition, the method was sufficiently sensitivite to detect unusual discrepancies by use of statistical analysis. Optimization of the system's detection capability and its receiver-operating characteristics is demonstrated. The results suggest that the statistical multiwavelength broadband approach to detection of gas mixture can be a highly effective alternative to species-specific single-line spectroscopy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA