Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ugeskr Laeger ; 186(16)2024 Apr 15.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38704724

RESUMO

Pyomyositis is a bacterial infection of striated muscle, usually located to muscles in the extremities or pelvis. We present a microbiologically unique case report of pyomyositis in the sternocleidomastoid muscle (the first of its kind in Denmark) caused by Staphylococcus epidermidis, S. capitis and possibly Streptococcus pneumoniae. Pyomyositis is very rare but can lead to critical complications such as endocarditis and sepsis. It is therefore important to know the condition when evaluating an infected patient with muscle pain. Treatment consists of antibiotics and - if relevant - surgical abscess drainage.


Assuntos
Antibacterianos , Músculos do Pescoço , Piomiosite , Infecções Estafilocócicas , Humanos , Piomiosite/microbiologia , Piomiosite/diagnóstico , Piomiosite/tratamento farmacológico , Feminino , Adulto , Músculos do Pescoço/patologia , Músculos do Pescoço/diagnóstico por imagem , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/microbiologia , Antibacterianos/uso terapêutico , Staphylococcus epidermidis/isolamento & purificação , Streptococcus pneumoniae/isolamento & purificação
2.
Ugeskr Laeger ; 185(39)2023 09 25.
Artigo em Dinamarquês | MEDLINE | ID: mdl-37873992

RESUMO

Injuries to the cartilaginous structures of the nose can arise after minor trauma and without a concomitant nasal fracture. They are diagnosed with a thorough clinical examination and can, if not diagnosed and treated in the acute phase, result in nasal/septal deformation, saddle nose or abscess formation with subsequent intracranial spreading of the infection. Even with proper treatment in the acute phase, the cartilage often heals with deviation. This can result in functional and cosmetic problems which may require later reconstructive surgery, as argued in this review.


Assuntos
Deformidades Adquiridas Nasais , Doenças Nasais , Rinoplastia , Humanos , Septo Nasal/lesões , Cartilagem/transplante , Doenças Nasais/cirurgia
3.
J Breath Res ; 17(4)2023 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-37657436

RESUMO

It can be a clinical challenge to distinguish inflammation from infection in critically ill patients. Therefore, valid and conclusive surrogate markers for infections are desired. Nitric oxide (NO) might be that marker since concentrations of exhaled NO have shown to change in the presence of various diseases. This observational, prospective, single-center feasibility study aimed to investigate if fractional exhaled NO (FeNO) can be measured in intubated patients with or without infection, pneumonia and septic shock in a standardized, reliable setting. 20 intubated patients in the intensive care unit (ICU) were included for analysis. FeNO mean values were measured in the endotracheal tube via the suction channel using a chemiluminescence based analyzer. We developed a pragmatic method to measure FeNO repeatedly and reliably in intubated patients using a chemiluminescence based analyzer. We found a median of 0.98 (0.59-1.44) FeNO mean (ppb) in exhaled breath from all 20 intubated patient. Intubated patient with suspected infection had a significantly lower median FeNO mean compared with the intubated patients without suspected infection. Similarly did patients with septic shock demonstrate a significantly lower median FeNO mean than without septic shock. We found no statistical difference in median FeNO mean for intubated patients with pneumonia. It was feasible to measure FeNO in intubated patients in the ICU. Our results indicate decreased levels of FeNO in infected intubated patients in the ICU. The study was not powered to provide firm conclusions, so larger trials are needed to confirm the results and to prove FeNO as a useful biomarker for distinguishment between infection and inflammation in the ICU.


Assuntos
Pneumonia , Choque Séptico , Humanos , Óxido Nítrico/análise , Estudos de Viabilidade , Respiração Artificial , Estudos Prospectivos , Testes Respiratórios/métodos , Inflamação , Expiração , Biomarcadores/análise , Unidades de Terapia Intensiva
4.
ERJ Open Res ; 6(4)2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33123551

RESUMO

Exhaled breath condensate (EBC) is safely collected in mechanically ventilated (MV) patients, but there are no guidelines regarding humidification of inhaled air during EBC collection. We investigated the influence of active and passive air humidification on EBC volumes obtained from MV patients. We collected 29 EBC samples from 21 critically ill MV patients with one condition of active humidification and four different conditions of non-humidification; 19 samples from 19 surgical MV patients with passive humidification and two samples from artificial lungs MV with active humidification. The main outcome was the obtained EBC volume per 100 L exhaled air. When collected with different conditions of non-humidification, mean [95% CI] EBC volumes did not differ significantly (1.35 [1.23; 1.46] versus 1.16 [1.05; 1.28] versus 1.27 [1.13; 1.41] versus 1.17 [1.00; 1.33] mL/100 L, p=0.114). EBC volumes were higher with active humidification than with non-humidification (2.05 [1.91; 2.19] versus 1.25 [1.17; 1.32] mL/100 L, p<0.001). The volume difference between these corresponded to the EBC volume obtained from artificial lungs (0.81 [0.62; 0.99] versus 0.89 mL/100 L, p=0.287). EBC volumes were lower for surgical MV patients with passive humidification compared to critically ill MV patients with non-humidification (0.55 [0.47; 0.63] versus 1.25 [1.17; 1.32] mL/100 L, p<0.001). While active humidification increases EBC volumes, passive humidification decreases EBC volumes and possibly influences EBC composition by other mechanisms. We propose that EBC should be collected from MV patients without air humidification to improve reproducibility and comparability across studies, and that humidification conditions should always be reported.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA