Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
BMC Health Serv Res ; 22(1): 994, 2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-35927703

RESUMO

OBJECTIVE: The objective was to assess the cost-effectiveness of transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis with intermediate surgical risk in Singapore. METHODS: A de novo Markov model with three health states - stroke with long-term sequelae, no stroke, and death - was developed and simulated using Monte Carlo simulations with 10,000 iterations over a five-year time horizon from the Singapore healthcare system perspective. A 3% annual discount rate for costs and outcomes and monthly cycle lengths were used. By applying the longest available published clinical evidence, simulated patients received either TAVI or surgical aortic valve replacement (SAVR) and were at risk of adverse events (AEs) such as moderate-to-severe paravalvular aortic regurgitation (PAR). RESULTS: When five-year PARTNER 2A data was applied, base-case analyses showed that the incremental cost-effectiveness ratio (ICER) for TAVI compared to SAVR was US$315,760 per quality-adjusted life year (QALY) gained. The high ICER was due to high incremental implantation and procedure costs of TAVI compared to SAVR, and marginal improvement of 0.10 QALYs as simulated mortality of TAVI exceeded SAVR at 3.75 years post-implantation. One-way sensitivity analysis showed that the ICERs were most sensitive to cost of PAR, utility values of SAVR patients, and cost of TAVI and SAVR implants and procedures. When disutilities for AEs were additionally applied, the ICER decreased to US$300,070 per QALY gained. TAVI was dominated by SAVR when the time horizon increased to 20 years. Clinical outcomes projected from one-year PARTNER S3i data further reduced the ICER to US$86,337 per QALY gained for TAVI, assuming early all-cause mortality benefits from TAVI continued to persist. This assumption was undermined when longer term data showed that TAVI's early mortality benefits diminished at five years. LIMITATIONS AND CONCLUSION: TAVI is unlikely to be cost-effective in intermediate surgical-risk patients compared to SAVR in Singapore.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Análise Custo-Benefício , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Fatores de Risco , Singapura/epidemiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
J Cardiovasc Magn Reson ; 23(1): 17, 2021 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-33658056

RESUMO

BACKGROUND: Stress cardiovascular magnetic resonance (CMR) offers assessment of ventricular function, myocardial perfusion and viability in a single examination to detect coronary artery disease (CAD). We developed an in-scanner exercise stress CMR (ExCMR) protocol using supine cycle ergometer and aimed to examine the diagnostic value of a multiparametric approach in patients with suspected CAD, compared with invasive fractional flow reserve (FFR) as the reference gold standard. METHODS: In this single-centre prospective study, patients who had symptoms of angina and at least one cardiovascular disease risk factor underwent both ExCMR and invasive angiography with FFR. Rest-based left ventricular function (ejection fraction, regional wall motion abnormalities), tissue characteristics and exercise stress-derived (perfusion defects, inducible regional wall motion abnormalities and peak exercise cardiac index percentile-rank) CMR parameters were evaluated in the study. RESULTS: In the 60 recruited patients with intermediate CAD risk, 50% had haemodynamically significant CAD based on FFR. Of all the CMR parameters assessed, the late gadolinium enhancement, stress-inducible regional wall motion abnormalities, perfusion defects and peak exercise cardiac index percentile-rank were independently associated with FFR-positive CAD. Indeed, this multiparametric approach offered the highest incremental diagnostic value compared to a clinical risk model (χ2 for the diagnosis of FFR-positive increased from 7.6 to 55.9; P < 0.001) and excellent performance [c-statistic area under the curve 0.97 (95% CI: 0.94-1.00)] in discriminating between FFR-normal and FFR-positive patients. CONCLUSION: The study demonstrates the clinical potential of using in-scanner multiparametric ExCMR to accurately diagnose CAD. TRIAL REGISTRATION: ClinicalTrials.gov, NCT03217227, Registered 11 July 2017-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT03217227?id=NCT03217227&draw=2&rank=1&load=cart.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão , Idoso , Ciclismo , Angiografia Coronária , Doença da Artéria Coronariana/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Singapura
3.
Heart Lung Circ ; 30(9): 1397-1405, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33812787

RESUMO

BACKGROUND: The success rate of coronary angiography (CA) after transcatheter aortic valve implantation (TAVI) is variable. Our aim was to investigate CA difficulty, outcomes, and predictors of difficult CA after TAVI. METHOD: This was an international multicentric retrospective cohort study that included patients with TAVI and subsequent CA between January 2010 and December 2019. Difficulty with CA was graded as 1 (normal), 2 (partial engagement, complete vessel opacification), 3 (partial engagement, incomplete vessel opacification), and 4 (unsuccessful angiography). Patients were grouped as (a) "easy" (grade 1 for left and right) or (b) "difficult" (grade >1 for either). We compared baseline characteristics and outcomes, and performed multivariate logistic regression for predictors of difficult CA. RESULTS: Of 96 patients included (mean age 77.4±8.7 years, 48 [50%] male), 88 (92%) had successful CA. Right CA was successful in 80 (83%) patients and left CA in 91 (95%) (p<0.0001). The "difficult" group (n=41 [43%]) had higher Society of Thoracic Surgery (STS) scores (7.6±4.9 vs 5.4±4.0; p=0.022), smaller annulus perimeters (72.4±5.4 mm vs 76.2±9.4 mm; p=0.049), greater use of self-expanding valves (83% vs 18%; p<0.0001), increased valve size (26.8±2.1 mm vs 25.6±3.0 mm; p=0.032), and increased oversizing for area (44.3%±17.4% vs 23.6%±22.0%; p=0.0002) and perimeter (17.5%±8.2% vs 7.1%±10.8%; p<0.0001). There was no difference in outcomes except for increased major bleeding (7.3% vs 0.0%; p=0.042). The strongest predictor for "difficult" CA was self-expanding valves when compared to balloon-expandable valves (adjusted odds ratio [aOR], 15.23; 95% confidence interval [CI], 2.27-102.40). Society of Thoracic Surgery score was borderline predictive (aOR, 1.26; 95% CI, 1.04-1.52). CONCLUSIONS: Our results show that after TAVI, CA success rate is high, right CA is more difficult than left, self-expanding valves predispose to difficult CA, and STS score weakly predicts difficult CA. This study is hypothesis-generating and more research is required to confirm these findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
4.
J Card Surg ; 35(9): 2142-2146, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32720374

RESUMO

OBJECTIVES: The impact of the COVID-19 pandemic on the treatment of patient with aortic valve stenosis is unknown and there is uncertainty on the optimal strategies in managing these patients. METHODS: This study is supported and endorsed by the Asia Pacific Society of Interventional Cardiology. Due to the inability to have face to face discussions during the pandemic, an online survey was performed by inviting key opinion leaders (cardiac surgeon/interventional cardiologist/echocardiologist) in the field of transcatheter aortic valve implantation (TAVI) in Asia to participate. The answers to a series of questions pertaining to the impact of COVID-19 on TAVI were collected and analyzed. These led subsequently to an expert consensus recommendation on the conduct of TAVI during the pandemic. RESULTS: The COVID-19 pandemic had resulted in a 25% (10-80) reduction of case volume and 53% of operators required triaging to manage their patients with severe aortic stenosis. The two most important parameters used to triage were symptoms and valve area. Periprocedural changes included the introduction of teleconsultation, preprocedure COVID-19 testing, optimization of protests, and catheterization laboratory set up. In addition, length of stay was reduced from a mean of 4.4 to 4 days. CONCLUSION: The COVID-19 pandemic has impacted on the delivery of TAVI services to patients in Asia. This expert recommendation on best practices may be a useful guide to help TAVI teams during this period until a COVID-19 vaccine becomes widely available.


Assuntos
COVID-19/epidemiologia , Cuidados Pré-Operatórios/normas , Substituição da Valva Aórtica Transcateter/normas , Estenose da Valva Aórtica/cirurgia , Ásia/epidemiologia , COVID-19/prevenção & controle , Teste para COVID-19 , Humanos , Controle de Infecções/normas , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Tempo de Internação/tendências , Pandemias , Consulta Remota , Inquéritos e Questionários , Triagem
5.
Environ Sci Technol ; 53(10): 5858-5867, 2019 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-30998850

RESUMO

The possibility of graphene oxide (GO) exposure to the environment has spurred several studies investigating the fate of this nanoparticle (NP). However, there is currently little or no data on the fate of GO in estuarine and marine waters. This study investigated the aggregation, sedimentation, and transformation of GO in saline waters, considering the roles of salinity (0-50 ‰), light (visible light and solar irradiation), and aging, among others. The attachment efficiency of GO reached unity at 1.33 ‰. The sedimentation rate of GO increased with salinity up to 10 ‰ after which it decreased due to formation of ramified GO agglomerates and media density. On the basis of the sedimentation rate determined at 30 ‰ (0.121 m/d), the residence time of GO agglomerates in the euphotic zone of typical open oceans will exceed 500 days. Aging in the presence of visible light increased the relative abundance of the GO's aromatic (C-C/C=C) fraction, reducing the NP. Reduction of GO in visible light was confirmed via UV-vis and Raman spectroscopic techniques. Reduction of GO was faster under solar irradiation. This study demonstrates that when introduced into saline waters, GO will undergo a range of transformations affecting its fate and potential effects to aquatic organisms.


Assuntos
Grafite , Nanopartículas , Energia Solar , Compostos Orgânicos , Óxidos
6.
Environ Sci Technol ; 52(8): 4491-4513, 2018 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-29505723

RESUMO

An increase in production of commercial products containing graphene-family nanomaterials (GFNs) has led to concern over their release into the environment. The fate and potential ecotoxicological effects of GFNs in the environment are currently unclear, partially due to the limited analytical methods for GFN measurements. In this review, the unique properties of GFNs that are useful for their detection and quantification are discussed. The capacity of several classes of techniques to identify and/or quantify GFNs in different environmental matrices (water, soil, sediment, and organisms), after environmental transformations, and after release from a polymer matrix of a product is evaluated. Extraction and strategies to combine methods for more accurate discrimination of GFNs from environmental interferences as well as from other carbonaceous nanomaterials are recommended. Overall, a comprehensive review of the techniques available to detect and quantify GFNs are systematically presented to inform the state of the science, guide researchers in their selection of the best technique for the system under investigation, and enable further development of GFN metrology in environmental matrices. Two case studies are described to provide practical examples of choosing which techniques to utilize for detection or quantification of GFNs in specific scenarios. Because the available quantitative techniques are somewhat limited, more research is required to distinguish GFNs from other carbonaceous materials and improve the accuracy and detection limits of GFNs at more environmentally relevant concentrations.


Assuntos
Grafite , Nanoestruturas , Ecotoxicologia , Limite de Detecção , Água
7.
Crit Rev Toxicol ; 47(9): 767-810, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28661217

RESUMO

Engineered nanomaterials (ENM) are a growing aspect of the global economy, and their safe and sustainable development, use, and eventual disposal requires the capability to forecast and avoid potential problems. This review provides a framework to evaluate the health and safety implications of ENM releases into the environment, including purposeful releases such as for antimicrobial sprays or nano-enabled pesticides, and inadvertent releases as a consequence of other intended applications. Considerations encompass product life cycles, environmental media, exposed populations, and possible adverse outcomes. This framework is presented as a series of compartmental flow diagrams that serve as a basis to help derive future quantitative predictive models, guide research, and support development of tools for making risk-based decisions. After use, ENM are not expected to remain in their original form due to reactivity and/or propensity for hetero-agglomeration in environmental media. Therefore, emphasis is placed on characterizing ENM as they occur in environmental or biological matrices. In addition, predicting the activity of ENM in the environment is difficult due to the multiple dynamic interactions between the physical/chemical aspects of ENM and similarly complex environmental conditions. Others have proposed the use of simple predictive functional assays as an intermediate step to address the challenge of using physical/chemical properties to predict environmental fate and behavior of ENM. The nodes and interactions of the framework presented here reflect phase transitions that could be targets for development of such assays to estimate kinetic reaction rates and simplify model predictions. Application, refinement, and demonstration of this framework, along with an associated knowledgebase that includes targeted functional assay data, will allow better de novo predictions of potential exposures and adverse outcomes.


Assuntos
Ecotoxicologia/métodos , Saúde Ambiental , Poluentes Ambientais/toxicidade , Nanoestruturas/toxicidade , Humanos , Modelos Teóricos , Medição de Risco , Segurança
8.
Environ Sci Technol ; 51(3): 1357-1363, 2017 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-27951641

RESUMO

To understand their fate and transport in estuarine systems, the aggregation, sedimentation, and dissolution of CdSe quantum dots (QDs) in seawater were investigated. Hydrodynamic size increased from 40 to 60 nm to >1 mm within 1 h in seawater, and the aggregates were highly polydispersed. Their sedimentation rates in seawater were measured to be 4-10 mm/day. Humic acid (HA), further increased their size and polydispersity, and slowed sedimentation. Light increased their dissolution and release of dissolved Cd. The ZnS shell also slowed release of Cd ions. With sufficient light, HA increased the dissolution of QDs, while with low light, HA alone did not change their dissolution. The benthic zone in estuarine systems is the most probable long-term destination of QDs due to aggregation and sedimentation. The bioavailability of was evaluated using the mysid Americamysis bahia. The 7-day LC50s of particulate and dissolved QDs were 290 and 23 µg (total Cd)/L, respectively. For mysids, the acute toxicity appears to be from Cd ions; however, research on the effects of QDs should be conducted with other organisms where QDs may be lodged in critical tissues such as gills or filtering apparatus and Cd ions may be released and delivered directly to those tissues.


Assuntos
Compostos de Cádmio , Pontos Quânticos , Animais , Disponibilidade Biológica , Água do Mar , Compostos de Selênio , Solubilidade
9.
Environ Sci Technol ; 49(16): 9532-47, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26182079

RESUMO

The unique or enhanced properties of manufactured nanomaterials (MNs) suggest that their use in nanoenabled products will continue to increase. This will result in increased potential for human and environmental exposure to MNs during manufacturing, use, and disposal of nanoenabled products. Scientifically based risk assessment for MNs necessitates the development of reproducible, standardized hazard testing methods such as those provided by the Organisation of Economic Cooperation and Development (OECD). Currently, there is no comprehensive guidance on how best to address testing issues specific to MN particulate, fibrous, or colloidal properties. This paper summarizes the findings from an expert workshop convened to develop a guidance document that addresses the difficulties encountered when testing MNs using OECD aquatic and sediment test guidelines. Critical components were identified by workshop participants that require specific guidance for MN testing: preparation of dispersions, dose metrics, the importance and challenges associated with maintaining and monitoring exposure levels, and the need for reliable methods to quantify MNs in complex media. To facilitate a scientific advance in the consistency of nanoecotoxicology test results, we identify and discuss critical considerations where expert consensus recommendations were and were not achieved and provide specific research recommendations to resolve issues for which consensus was not reached. This process will enable the development of prescriptive testing guidance for MNs. Critically, we highlight the need to quantify and properly interpret and express exposure during the bioassays used to determine hazard values.


Assuntos
Organismos Aquáticos/efeitos dos fármacos , Consenso , Nanoestruturas/toxicidade , Testes de Toxicidade/métodos , Animais , Bioensaio , Exposição Ambiental/análise , Humanos
10.
Environ Sci Technol ; 48(23): 13711-7, 2014 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-25369427

RESUMO

The toxicity, bioaccumulation, and biotransformation of citrate and polyvinylpyrrolidone (PVP) coated silver nanoparticles (NPs) (AgNP-citrate and AgNP-PVP) in marine organisms via marine sediment exposure was investigated. Results from 7-d sediment toxicity tests indicate that AgNP-citrate and AgNP-PVP did not exhibit toxicity to the amphipod (Ampelisca abdita) and mysid (Americamysis bahia) at ≤75 mg/kg dry wt. A 28-d bioaccumulation study showed that Ag was significantly accumulated in the marine polychaete Nereis virens (N. virens) in the AgNP-citrate, AgNP-PVP and a conventional salt (AgNO3) treatments. Synchrotron X-ray absorption spectroscopy (XAS) results showed the distribution of Ag species in marine sediments amended with AgNP-citrate, AgNP-PVP, and AgNO3 was AgCl (50­65%) > Ag2S (32­42%) > Ag metal (Ag0) (3­11%). In N virens, AgCl (25­59%) and Ag2S (10­31%) generally decreased and, Ag metal (32­44%) increased, relative to the sediments. The patterns of speciation in the worm were different depending upon the coating of the AgNP and both types of AgNPs were different than the AgNO3 salt. These results show that the AgNP surface capping agents influenced Ag uptake, biotransformation, and/or excretion. To our knowledge, this is the first demonstration of the bioaccumulation and speciation of AgNPs in a marine organism (N. virens).


Assuntos
Organismos Aquáticos , Nanopartículas Metálicas/toxicidade , Prata/farmacocinética , Prata/toxicidade , Testes de Toxicidade/métodos , Poluentes Químicos da Água/farmacocinética , Anfípodes/metabolismo , Animais , Biotransformação , Ácido Cítrico/química , Ácido Cítrico/farmacocinética , Crustáceos/metabolismo , Meio Ambiente , Sedimentos Geológicos/análise , Sedimentos Geológicos/química , Poliquetos/metabolismo , Povidona/química , Povidona/farmacocinética , Prata/química , Espectrometria por Raios X/métodos , Poluentes Químicos da Água/química , Poluentes Químicos da Água/toxicidade , Espectroscopia por Absorção de Raios X
11.
Mar Pollut Bull ; 202: 116393, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38669855

RESUMO

Microplastics (MP) are found in marine sediments across the globe, but we are just beginning to understand their spatial distribution and assemblages. In this study, we quantified MP in Gulf of Maine, USA sediments. MP were extracted from 20 sediment samples, followed by polymer identification using Raman spectroscopy. We detected 27 polymer types and 1929 MP kg-1 wet sediment, on average. Statistical analyses showed that habitat, hydrodynamics, and station proximity were more important drivers of MP assemblages than land use or sediment characteristics. Stations closer to one another were more similar in their MP assemblages, tidal rivers had higher numbers of unique plastic polymers than open water or embayment stations, and stations closer to shore had higher numbers of MP. There was little evidence of relationships between MP assemblages and land use, sediment texture, total organic carbon, or contaminants.


Assuntos
Monitoramento Ambiental , Sedimentos Geológicos , Hidrodinâmica , Microplásticos , Poluentes Químicos da Água , Sedimentos Geológicos/química , Maine , Microplásticos/análise , Poluentes Químicos da Água/análise
12.
Eur Heart J Open ; 4(2): oeae025, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38659665

RESUMO

Aims: Aging-related cardiovascular disease and frailty burdens are anticipated to rise with global aging. In response to directions from major cardiovascular societies, we investigated frailty knowledge, awareness, and practices among cardiologists as key stakeholders in this emerging paradigm a year after the European Frailty in Cardiology consensus document was published. Methods and results: We launched a prospective multinational web-based survey via social networks to broad cardiology communities representing multiple World Health Organization regions, including Western Pacific and Southeast Asia regions. Overall, 578 respondents [38.2% female; ages 35-49 years (55.2%) and 50-64 years (34.4%)] across subspecialties, including interventionists (43.3%), general cardiologists (30.6%), and heart failure specialists (HFSs) (10.9%), were surveyed. Nearly half had read the consensus document (38.9%). Non-interventionists had better perceived knowledge of frailty assessment instruments (fully or vaguely aware, 57.2% vs. 45%, adj. P = 0.0002), exercise programmes (well aware, 12.9% vs. 6.0%, adj. P = 0.001), and engaged more in multidisciplinary team care (frequently or occasionally, 52.6% vs. 41%, adj. P = 0.002) than interventionists. Heart failure specialists more often addressed pre-procedural frailty (frequently or occasionally, 43.5% vs. 28.2%, P = 0.004) and polypharmacy (frequently or occasionally, 85.5% vs. 71%, adj. P = 0.014) and had consistently better composite knowledge (39.3% vs. 21.6%, adj. P = 0.001) and practice responses (21% vs. 11.1%, adj. P = 0.018) than non-HFSs. Respondents with better knowledge responses also had better frailty practices (40.3% vs. 3.6%, adj. P < 0.001). Conclusion: Distinct response differences suggest that future strategies strengthening frailty principles should address practices peculiar to subspecialties, such as pre-procedural frailty strategies for interventionists and rehabilitation interventions for HFSs.

13.
AsiaIntervention ; 10(1): 51-59, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38425806

RESUMO

Background: The use of cerebral embolic protection devices during transcatheter aortic valve implantation (TAVI) reveals conflicting data. Aims: This updated meta-analysis aims to evaluate the efficacy and safety of the SENTINEL Cerebral Protection System. Methods: A literature search for relevant studies up to September 2022 was performed. Study outcomes were divided based on time period - overall (up to 30 days) and short (≤7 days). The outcomes studied include stroke (disabling, non-disabling), mortality, neuroimaging findings, transient ischaemic attack, acute kidney injury and major vascular and bleeding complications. Results: A total of 15 studies involving 294,134 patients were included. Regarding overall outcomes, significant reductions were noted for mortality (odds ratio [OR] 0.60, 95% confidence interval [CI]: 0.41-0.88; p=0.008), all stroke (OR 0.64, 95% CI: 0.46-0.88; p=0.006) and disabling stroke (OR 0.42, 95% CI: 0.23-0.74; p=0.003) using the SENTINEL device. No significant differences were noted for other outcomes. There was significant heterogeneity across the studies for mortality (p=0.013) and all stroke (p=0.003). Including only randomised data (n=4), there was only significant reduction in the incidence of disabling stroke (OR 0.39, 95% CI: 0.17-0.89; p=0.026) in the SENTINEL group. In studies reporting ≤7-day outcomes (n=8), use of the SENTINEL device demonstrated significantly lower rates of all stroke (p<0.001), disabling stroke (p<0.001) and major bleeding complications (p=0.02). No differences in neuroimaging outcomes were noted. Conclusions: In this updated meta-analysis, use of the SENTINEL Cerebral Protection System was associated with lower rates of mortality, all stroke and disabling stroke, although significant heterogeneity was noted for mortality and all stroke. Including exclusively randomised data, there was only significant reduction in the incidence of disabling stroke. No significant adverse outcomes with device use were noted.

14.
Am J Cardiol ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39053723

RESUMO

A metanalysis of available randomized controlled trials and observational studies comparing self-expanding and balloon-expandable bioprostheses in patients with small aortic annulus and aortic stenosis for short and midterm hemodynamic and clinical outcomes was performed. 21 studies with a total 8647 patients (self-expanding, n=4,336 patients vs balloon-expandable, n= 4,311 patients) were included. Self-expanding bioprostheses had a lower post-operative mean gradient at 30 days (MD -5.16, 95%CI 4.7-5.5, p value <0.001) and at one year (MD -6.6, 95%CI 6.1-7.03, p value <0.001), with a larger indexed Effective Orifice Area (0.17, 95%CI 0.13-0.22, p value <0.001and 0.17, 95%CI 0.08-0.27, p value < 0.001) at both time intervals. Balloon-expandable bioprostheses had a higher risk of 30-day and 1-year severe prosthesis-patient mismatch (RR 1.07, 95%CI 1.04-1.09, p value < 0.001; RR 1.07, 95%CI 1.04-1.11, p value <0.001). 30-day and 1 year paravalvular leaks (RR 0.99, 95%CI 0.98-0.99, p value < 0.001; RR 0.89, 95%CI 0.82-0.95, p value <0.001) and permanent pacemaker implantation (RR 0.97, 95%CI .94-0.99, p value 0.01, I2= 40%,) were lower in balloon-expandable group. Balloon-expandable bioprostheses were associated with lower risk of in-hospital stroke (RR 0.99, 95%CI 0.98-1,p value= 0.01). In conclusion, in patients with small aortic annulus and aortic stenosis, SE bioprostheses have superior haemodynamic performance but higher rates of PVL, PPI and in-hospital stroke. BE bioprostheses were associated with a higher risk of severe PPM.

15.
Sci Total Environ ; 927: 171153, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38460683

RESUMO

About 3 billion new tires are produced each year and about 800 million tires become waste annually. Global dependence upon tires produced from natural rubber and petroleum-based compounds represents a persistent and complex environmental problem with only partial and often-times, ineffective solutions. Tire emissions may be in the form of whole tires, tire particles, and chemical compounds, each of which is transported through various atmospheric, terrestrial, and aquatic routes in the natural and built environments. Production and use of tires generates multiple heavy metals, plastics, PAH's, and other compounds that can be toxic alone or as chemical cocktails. Used tires require storage space, are energy intensive to recycle, and generally have few post-wear uses that are not also potential sources of pollutants (e.g., crumb rubber, pavements, burning). Tire particles emitted during use are a major component of microplastics in urban runoff and a source of unique and highly potent toxic substances. Thus, tires represent a ubiquitous and complex pollutant that requires a comprehensive examination to develop effective management and remediation. We approach the issue of tire pollution holistically by examining the life cycle of tires across production, emissions, recycling, and disposal. In this paper, we synthesize recent research and data about the environmental and human health risks associated with the production, use, and disposal of tires and discuss gaps in our knowledge about fate and transport, as well as the toxicology of tire particles and chemical leachates. We examine potential management and remediation approaches for addressing exposure risks across the life cycle of tires. We consider tires as pollutants across three levels: tires in their whole state, as particulates, and as a mixture of chemical cocktails. Finally, we discuss information gaps in our understanding of tires as a pollutant and outline key questions to improve our knowledge and ability to manage and remediate tire pollution.

16.
Environ Sci Technol ; 47(3): 1306-12, 2013 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-23305514

RESUMO

Aquatic organisms are exposed to many toxic chemicals and interpreting the cause and effect relationships between occurrence and impairment is difficult. Toxicity Identification Evaluation (TIE) provides a systematic approach for identifying responsible toxicants. TIE relies on relatively uninformative and potentially insensitive toxicological end points. Gene expression analysis may provide needed sensitivity and specificity aiding in the identification of primary toxicants. The current work aims to determine the added benefit of integrating gene expression end points into the TIE process. A cDNA library and a custom microarray were constructed for the marine amphipod Ampelisca abdita. Phase 1 TIEs were conducted using 10% and 40% dilutions of acutely toxic sediment. Gene expression was monitored in survivors and controls. An expression-based classifier was developed and evaluated against control organisms, organisms exposed to low or medium toxicity diluted sediment, and chemically selective manipulations of highly toxic sediment. The expression-based classifier correctly identified organisms exposed to toxic sediment even when little mortality was observed, suggesting enhanced sensitivity of the TIE process. The ability of the expression-based end point to correctly identify toxic sediment was lost concomitantly with acute toxicity when organic contaminants were removed. Taken together, this suggests that gene expression enhances the performance of the TIE process.


Assuntos
Anfípodes/genética , Organismos Aquáticos/genética , Determinação de Ponto Final , Genoma/genética , Testes de Toxicidade , Poluentes Químicos da Água/toxicidade , Anfípodes/efeitos dos fármacos , Animais , Organismos Aquáticos/efeitos dos fármacos , Biomarcadores/metabolismo , Regulação da Expressão Gênica/efeitos dos fármacos , Sedimentos Geológicos/química , Rhode Island , Rios/química
17.
Environ Pollut ; 338: 122650, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37777055

RESUMO

Plastic particles are ubiquitous in marine systems and fragment into smaller pieces, such as nanoplastics (NPs). The effects of NPs on marine organisms are of growing concern but are not well understood. Marine sediments act as a sink for many contaminants, like microplastics, and are rich habitats for benthic micro- and meiofauna which are ecologically-important components of marine food webs; however, little is known about the sensitivities of specific organisms to NPs or the effects on community diversity and composition. Utilizing molecular methods, such as metabarcoding of environmental DNA/RNA, allows for the rapid and comprehensive detection of microscopic organisms via high-throughput sequencing to assess adverse effects at the community level. The objective of this study was to use a metabarcoding approach to investigate the effects of NPs on benthic micro- and meiofaunal community diversity. Mesocosms were created with sediment cores collected from the Narrow River estuary (Rhode Island, USA) and exposed to 900 nm diameter weathered polystyrene beads at concentrations of 0.1, 1, 10, or 100 mg/kg dry weight in sediment for two weeks. Following exposure, RNA and DNA were co-extracted from the sediment, RNA was reverse-transcribed, 18S and COI markers were PCR-amplified, and amplicons were sequenced on an Illumina MiSeq. Using the 18S marker and eRNA template, increases to α-diversity and significant differences to ß-diversity were observed in the highest NP exposures relative to the control. Observed differences in community composition were driven by the differential abundance of several types of protists and arthropods. Significant dose-dependent shifts in composition were observed in ß-diversity Jaccard and Unweighted-Unifrac metrics with the 18S marker using the RNA template. To our knowledge, this is the first demonstration of a dose-response relationship for NPs at a community level, and it highlights the value of using community-level endpoints to assess environmental impacts of nanoparticles.


Assuntos
DNA Ambiental , Ecossistema , Microplásticos , Biodiversidade , Plásticos/toxicidade , Código de Barras de DNA Taxonômico , RNA
18.
Chemosphere ; 313: 137479, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36513195

RESUMO

Microplastics (MP) are distributed throughout ecosystems and settle into sediments where they may threaten benthic communities; however, methods for quantifying MP in sediments have not been standardized. This study compares two methods for analyzing MP in sediments, including extraction and identification, and provides recommendations for improvement. Two laboratories processed sediment samples using two methods, referred to as "core" and "augmentation", and identified particles with visual microscopy and spectroscopy. Using visual microscopy, the augmentation method yielded mean recoveries (78%) significantly greater than the core (47%) (p = 0.03), likely due to the use of separatory funnels in the former. Spectroscopic recovery of particles was lower at 42 and 54% for the core and augmentation methods, respectively. We suspect the visual identification recoveries are overestimations from erroneous identification of non-plastic materials persisting post-extraction, indicating visual identification alone is not an accurate method to identify MP, particularly in complex matrices like sediment. However, both Raman and FTIR proved highly accurate at identifying recovered MP, with 96.7% and 99.8% accuracy, respectively. Low spectroscopic recovery of spiked particles indicates that MP recovery from sediments is lower than previously assumed, and MP may be more abundant in sediments than current analyses suggest. To our knowledge, likely due to the excessive time/labor-intensity associated with MP analyses, this is the first interlaboratory study to quantify complete method performance (extraction, identification) for sediments, with regards to capabilities and limitations. This is essential as regulatory bodies move toward long-term environmental MP monitoring.


Assuntos
Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Sedimentos Geológicos/química , Ecossistema , Microplásticos/análise , Plásticos , Monitoramento Ambiental/métodos
19.
Mar Pollut Bull ; 192: 115073, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37245322

RESUMO

A common method for characterizing microplastics (MPs) involves capturing the plastic particles on a filter after extraction and isolation from the sediment particles. Microplastics captured on the filter are then scanned with Raman spectroscopy for polymer identification and quantification. However, scanning the whole filter manually using Raman analysis is a labor-intensive and time-consuming process. This study investigates a subsampling method for Raman spectroscopic analysis of microplastics (operationally defined here as 45-1000 µm in size) present in sediments and isolated onto laboratory filters. The method was evaluated using spiked MPs in deionized water and two environmentally contaminated sediments. Based on statistical analyses, we found quantification of a sub-fraction of 12.5 % of the filter in a wedge form was optimal, efficient, and accurate for estimating the entire filter count. The extrapolation method was then used to assess microplastic contamination in sediments from different marine regions of the United States.


Assuntos
Microplásticos , Poluentes Químicos da Água , Microplásticos/análise , Plásticos/análise , Análise Espectral Raman , Poluentes Químicos da Água/análise , Monitoramento Ambiental , Sedimentos Geológicos/química
20.
Chemosphere ; 333: 138883, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37169088

RESUMO

Quality assurance and quality control (QA/QC) techniques are critical to analytical chemistry, and thus the analysis of microplastics. Procedural blanks are a key component of QA/QC for quantifying and characterizing background contamination. Although procedural blanks are becoming increasingly common in microplastics research, how researchers acquire a blank and report and/or use blank contamination data varies. Here, we use the results of laboratory procedural blanks from a method evaluation study to inform QA/QC procedures for microplastics quantification and characterization. Suspected microplastic contamination in the procedural blanks, collected by 12 participating laboratories, had between 7 and 511 particles, with a mean of 80 particles per sample (±SD 134). The most common color and morphology reported were black fibers, and the most common size fraction reported was 20-212 µm. The lack of even smaller particles is likely due to limits of detection versus lack of contamination, as very few labs reported particles <20 µm. Participating labs used a range of QA/QC techniques, including air filtration, filtered water, and working in contained/'enclosed' environments. Our analyses showed that these procedures did not significantly affect blank contamination. To inform blank subtraction, several subtraction methods were tested. No clear pattern based on total recovery was observed. Despite our results, we recommend commonly accepted procedures such as thorough training and cleaning procedures, air filtration, filtered water (e.g., MilliQ, deionized or reverse osmosis), non-synthetic clothing policies and 'enclosed' air flow systems (e.g., clean cabinet). We also recommend blank subtracting by a combination of particle characteristics (color, morphology and size fraction), as it likely provides final microplastic particle characteristics that are most representative of the sample. Further work should be done to assess other QA/QC parameters, such as the use of other types of blanks (e.g., field blanks, matrix blanks) and limits of detection and quantification.


Assuntos
Microplásticos , Poluentes Químicos da Água , Plásticos/análise , Laboratórios , Controle de Qualidade , Água/análise , Monitoramento Ambiental/métodos , Poluentes Químicos da Água/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA