Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Sensors (Basel) ; 22(11)2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35684806

RESUMO

The preconditioning and modification of the supporting electrode surface is an essential step in every biosensor architecture. In particular, when using screen-printed carbon electrodes (SPEs) as inexpensive and convenient disposable sensor substrates, their somewhat lower electrochemical (surface) reproducibility might represent a complex hurdle. Herein, we investigated the effect of selected preconditioning strategies, such as cyclic voltammetric pretreatment, in H2SO4 and H2O2 and plasma pretreatment with a positive and negative glow discharge, which all improved the electrochemical stability of the unmodified SPEs. Furthermore, we studied the influence of preconditioning strategies on the adsorption kinetics of the two most commonly used building blocks for biosensor preparation, i.e., bovine serum albumin (BSA) and protein A. We observed an advantageous effect of all the examined preconditioning strategies for the modification of SPEs with protein A, being the most effective the negative glow discharge. On the other hand, BSA exhibited a more complex adsorption behavior, with the negative glow discharge as the only generally beneficial preconditioning strategy providing the highest electrochemical stability. Protein A revealed a more substantial impact on the electrochemical signal attenuation than BSA considering their same concentrations in the modification solutions. For both BSA and protein A, we showed that the concentrations of 5 and 10 µg mL-1 already suffice for an electrochemically satisfactorily stable electrode surface after 60 min of incubation time, except for BSA at the positive-plasma-treated electrode.


Assuntos
Carbono , Técnicas Eletroquímicas , Adsorção , Eletrodos , Peróxido de Hidrogênio , Reprodutibilidade dos Testes , Soroalbumina Bovina
2.
Analyst ; 144(2): 488-497, 2019 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-30467573

RESUMO

The present work aims to study the effects that acute exposure to low concentrations of silver nanoparticles (AgNPs) cause in digestive glands of terrestrial isopods (Porcellio scaber). The experiments were designed to integrate different analytical techniques, such as transmission electron microscopy, atomic absorption spectroscopy, proton induced X-ray emission, and Fourier transform IR imaging (FTIRI), in order to gain a comprehensive insight into the process from the AgNPs' synthesis to their interaction with biological tissues in vivo. To this aim, terrestrial isopods were fed with AgNPs having different shapes, sizes, and concentrations. For all the tested conditions, no toxicity at the whole organism level was observed after 14 days of exposure. However, FTIRI showed that AgNPs caused detectable local changes in proteins, lipids, nucleic acids and carbohydrates at the tissue level, to an extent dependent on the interplay of the AgNPs' properties: shape, size, concentration and dissolution of ions from them.


Assuntos
Isópodes/química , Nanopartículas Metálicas/química , Prata/química , Animais , Feminino , Mucosa Intestinal/química , Mucosa Intestinal/efeitos dos fármacos , Mucosa Intestinal/metabolismo , Mucosa Intestinal/patologia , Isópodes/efeitos dos fármacos , Isópodes/metabolismo , Masculino , Nanopartículas Metálicas/administração & dosagem , Microscopia , Tamanho da Partícula , Análise de Componente Principal , Solubilidade , Espectroscopia de Infravermelho com Transformada de Fourier
3.
Sensors (Basel) ; 18(12)2018 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-30513847

RESUMO

Progesterone is an important hormone responsible, among others, for maintaining pregnancy via inhibition of uterus muscles activity; thus, following its concentration levels in pregnant women is of immense importance in the endeavor to prevent premature birth. In this work, the nanostructured bismuth film electrode (nsBiFE) was studied for detection of progesterone in neutral medium. Due to the ability to accumulate progesterone at the nsBiFE, the adsorptive cathodic stripping voltammetry was beneficially exploited. The nsBiFE was prepared on the surface of a glassy carbon supporting electrode and several parameters influencing the detection of progesterone were investigated. The nsBiFE exhibited superior electroanalytical characteristics in comparison to other bismuth-based electrodes and unmodified glassy carbon electrode together with satisfactory response toward low concentrations of progesterone, which are consistent with clinically significant levels.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Nanoestruturas/química , Progesterona/isolamento & purificação , Adsorção , Bismuto/química , Carbono/química , Feminino , Humanos , Gravidez , Progesterona/química
4.
ACS Appl Mater Interfaces ; 16(23): 30196-30208, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38814245

RESUMO

Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.


Assuntos
Técnicas Biossensoriais , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/análise , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Técnicas Biossensoriais/métodos , Humanos , Imunoensaio/métodos , Limite de Detecção , COVID-19/diagnóstico , COVID-19/virologia , Técnicas Eletroquímicas/métodos , Eletrodos
5.
Nat Commun ; 14(1): 6474, 2023 10 14.
Artigo em Inglês | MEDLINE | ID: mdl-37838694

RESUMO

Listeriosis is one of the most serious foodborne diseases caused by the intracellular bacterium Listeria monocytogenes. Its two major virulence factors, broad-range phospholipase C (LmPC-PLC) and the pore-forming toxin listeriolysin O (LLO), enable the bacterium to spread in the host by destroying cell membranes. Here, we determine the crystal structure of LmPC-PLC and complement it with the functional analysis of this enzyme. This reveals that LmPC-PLC has evolved several structural features to regulate its activity, including the invariant position of the N-terminal tryptophan (W1), the structurally plastic active site, Zn2+-dependent activity, and the tendency to form oligomers with impaired enzymatic activity. We demonstrate that the enzymatic activity of LmPC-PLC can be specifically inhibited by its propeptide added in trans. Furthermore, we show that the phospholipase activity of LmPC-PLC facilitates the pore-forming activity of LLO and affects the morphology of LLO oligomerization on lipid membranes, revealing the multifaceted synergy of the two virulence factors.


Assuntos
Listeria monocytogenes , Listeriose , Humanos , Fosfolipases Tipo C/metabolismo , Listeriose/microbiologia , Proteínas Hemolisinas/metabolismo , Membrana Celular/metabolismo , Fatores de Virulência/metabolismo
6.
ACS Appl Mater Interfaces ; 15(26): 31643-31651, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37350261

RESUMO

The development of sensitive, selective, and reliable gaseous hydrogen peroxide (H2O2) sensors operating at room temperature still represents a remaining challenge. In this work, we have investigated and combined the advantageous properties of a two-dimensional Ti3C2Tx MXene material that exhibits a large specific surface area and high surface activity, with favorable conducting and stabilizing properties of chitosan. The MXene-chitosan membrane was deposited on the ferrocyanide-modified screen-printed working carbon electrode, followed by applying poly(acrylic acid) as an electrolyte and accumulation medium for gaseous H2O2. The sensor showed highly sensitive and selective electroanalytical performance for detecting trace concentrations of gaseous H2O2 with a very low detection limit of 4 µg m-3 (4 ppbv), linear response in the studied concentration range of 0.5-30.0 mg m-3, and good reproducibility with an RSD of 1.3%. The applicability of the sensor was demonstrated by point-of-interest detection of gaseous H2O2 during the real hair bleaching process with a 9 and 12% H2O2 solution.

7.
Anal Chem ; 84(10): 4429-36, 2012 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-22462643

RESUMO

A mechanistic study to provide diagnostics of anodic stripping electrode processes at bismuth-film electrodes is presented from both theoretical and experimental points of view. Theoretical models for three types of electrode mechanisms are developed under conditions of square-wave voltammetry, combining rigorous modeling based on integral equations and the step function method, resulting in derivation of a single numerical recurrent formula to predict the outcome of the voltammetric experiment. In the course of the deposition step, it has been assumed that a uniform film of the metal analyte is formed on the bismuth substrate, in situ deposited onto a glassy carbon electrode surface, without considering mass transfer within either the bismuth or the metal analyte film. Theoretical data are analyzed in terms of dimensionless critical parameters related with electrode kinetics, mass transfer, adsorption equilibria, and possible lateral interactions within the deposited metal particles. Theoretical analysis enables definition of simple criteria for differentiation and characterization of electrode processes. Comparing theoretical and experimental data, anodic stripping processes of zinc(II), cadmium(II), and lead(II) are successfully characterized, revealing significant differences in their reaction pathways. The proposed easy-to-perform diagnostic route is considered to be of a general use while the bismuth film exploited in this study served as a convenient nonmercury model substrate surface.

8.
ACS Sens ; 5(8): 2570-2577, 2020 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-32597168

RESUMO

The detection of volatile organic compounds with electrochemical gas sensors is still very challenging regarding their sensitivity, selectivity, and operation at room temperature. There is a need for robust, sensitive, inexpensive, and yet easy-to-operate sensors for phenol and other phenolic compounds that function reliably under ambient conditions. Herein, we present a phenol gas sensor based on a combination of a semisolid, alkaline sodium polyacrylate, and commercial screen-printed electrodes. Sodium polyacrylate was employed as a multifunctional sensing material serving as a (i) gel-like electrolyte, (ii) accumulation milieu, and (iii) derivatization medium. Under ambient conditions, the sensor showed excellent sensitivity in the low ppbv (µg m-3) range, a good linear operation in the examined concentration range of 0.1-1.0 ppmv for up to 105 min accumulation, and low sensitivity toward examined interferences. The sensor also indicated a possibility to differentiate between several phenolic compounds based on their oxidation potential. Given its favorable electroanalytical performance, a strong application potential is envisioned in topical fields such as environmental monitoring, cultural heritage preservation, and occupational health and safety.


Assuntos
Gases , Fenol , Resinas Acrílicas , Fenóis , Sódio , Temperatura
10.
Front Biosci ; 11: 2782-9, 2006 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16720351

RESUMO

The in vivo performance of a voltammetric microprobe based on overoxidized poly(1,2-phenylenediamine) coated carbon fiber microelectrode (OPPD/CFME), developed in our laboratory, is presented. For this purpose, an OPPD microprobe was stereotaxicaly implanted in the striatum of a deeply anesthetized Wistar rat for the simultaneous measurement of dopamine, serotonin and ascorbate. Furthermore, the post mortem levels of these physiologically important compounds were monitored after the rats were terminated with an overdose of anesthetic introduced through an indwelling jugular catheter. Using cyclic (CV) and square-wave (SWV) voltammetry, the OPPD/CFME was demonstrated to exhibit efficient separation of the voltammetric signals of dopamine, serotonin and ascorbate in the presence of biological matrix, with the SWV mode allowing more convenient detection regarding both sensitivity and selectivity. Explicit proof of in vivo dopamine detection at the OPPD/CFME was achieved via the absence of the dopamine signal in rats with unilateral lesions of nigrostriatal dopaminergic neurons, which was induced by the use of the selective dopaminergic neurotoxin 6-hydroxydopamine (6-OHDA). In stark contrast to non-treated rats, where a strong signal corresponding to 1.2 micro M dopamine was measured at ca. 90 s after the rats' death, the signal for dopamine in dopamine-depleted striatum of 6-OHDA rats was absent. A critical comparison of the in vivo performance of the OPPD/CFME to that of bare and Nafion-coated carbon fiber microelectrodes, often used in neurophysiological studies, clearly showed a significant advantage of the former microprobe. The OPPD/CFME allowed multiple and repetitive in vivo measurements, along with pre- and post-measurement external calibration, with no loss in selectivity and an acceptable loss in sensitivity, indicating that the active sensing sites were not adversely blocked by the components of the extracellular fluid, thus affirming the great practical in vivo applicability of the OPPD microprobe.


Assuntos
Ácido Ascórbico/análise , Corpo Estriado/química , Dopamina/análise , Serotonina/análise , Animais , Eletroquímica , Feminino , Microeletrodos , Ratos , Ratos Wistar , Técnicas Estereotáxicas
11.
Environ Pollut ; 218: 957-964, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27567171

RESUMO

We assessed the bioavailability of Ag from Ag nanoparticles (NPs), stabilized with polyvinylpyrrolidone (PVP), to terrestrial isopods which were exposed to 10, 100 and 1000 µg Ag NPs/g of dry food. Different Ag species were determined in the NP suspension that was fed to isopods: (i) total Ag by atomic absorption spectroscopy, (ii) the sum of Ag-PVP complexes and free Ag+ by anodic stripping voltammetry at the bismuth-film electrode, and (iii) free Ag+ by ion-selective potentiometry. The amounts of Ag species in the consumed food were compared to the masses of Ag accumulated in the isopod digestive glands. Our results show that all three Ag species (Ag NPs, Ag-PVP complexes and free Ag+) could be the source of bioaccumulated Ag, but to various degrees depending on the exposure concentration and transformations in the digestive system. We provide a proof that (i) Ag NPs dissolve and Ag-PVP complexes dissociate in the isopod digestive tract; (ii) the concentration of free Ag+ in the suspension offered to the test organisms is not the only measure of bioavailable Ag. The type of NP stabilizer along with the NP transformations in the digestive system needs to be considered in the creation of new computational models of the nanomaterial fate.


Assuntos
Isópodes/metabolismo , Nanopartículas Metálicas/química , Povidona/química , Prata/farmacocinética , Animais , Disponibilidade Biológica , Trato Gastrointestinal/metabolismo , Isópodes/efeitos dos fármacos , Prata/química , Suspensões
12.
Front Biosci ; 10: 483-91, 2005 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-15574385

RESUMO

Electrochemically modified screen-printed carbon electrode (SPCE) has been prepared by electrodepositing nickel hexacyanoferrate(III) (NiHCF) onto the electrode surface using cyclic voltammetry (CV). The performance of NiHCF-SPCE sensor was characterized and optimized by controlling several operational parameters. The NiHCF film has been proven to remain stable after CV scanning from 0 to +1.0 V vs. Ag/AgCl in the pH range of 3 to 10 and is re-useable. The most favourable supporting electrolyte solution exhibiting the optimum electroanalytical performance of the NiHCF-SPCE sensor was found to be 0.2 mol/L sodium nitrate. The electrochemical response toward ascorbic acid (AA) and H2O2 in 0.2 mol/L sodium nitrate solution was studied by using CV and the results showed that both analytes were electrocatalytically oxidized at approximately +0.4 V, while H2O2 also revealed a reduction signal at -0.8 V vs. Ag/AgCl. The NiHCF-SPCE sensor exhibited highly linear response for AA and H2O2 in the examined concentration range from 5.0x10-5 to 1.5x10-3 mol/L and from 2.0x10-5 to 1.0x10-3 mol/L (at +0.4 V), with the correlation coefficients of 0.999 and 0.998, respectively. The reproducibility of the NiHCF-SPCE sensor was followed for the determination of AA by using four individual electrodes, and the relative standard deviation of CV peak currents varied between 0.9 % and 2.2 %. The proposed NiHCF-SPCE has been shown to be a very attractive electrochemical sensor for AA and H2O2, also in a view of inexpensive mass production of disposable single-use sensors. The NiHCF-SPCE sensor was tested by measuring AA in multivitamin tablets, with recoveries obtained between 94.4 % and 108.2 % (n=5).


Assuntos
Ácido Ascórbico/química , Carbono/química , Eletroquímica/instrumentação , Eletroquímica/métodos , Ferrocianetos/química , Peróxido de Hidrogênio/química , Níquel/química , Técnicas Biossensoriais , Suplementos Nutricionais , Eletrodos , Humanos , Concentração de Íons de Hidrogênio , Nitratos/química
13.
J Phys Chem B ; 109(30): 14387-95, 2005 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-16852810

RESUMO

A new sol-gel precursor, based on 1-methyl-3-[3-(trimethoxy-lambda(4)-silyl)propyl]imidazolium iodide (MTMSPI(+)I(-)), was synthesized and investigated as a potential novel quasi-solid-state ionic liquid redox electrolyte for dye-sensitized photoelectrochemical (DSPEC) cells of the Graetzel type. MTMSPI(+)I(-) was hydrolyzed with acidified water, and the reaction products of the sol-gel condensation reactions were assessed with the help of (29)Si NMR and infrared spectroscopic techniques. Results of time-dependent analyses showed the formation of a positively charged polyhedral cubelike silsesquioxane species, which still contained a small amount of silanol end groups that were removed after heating at 200 degrees C. After cooling, the material formed was a tough, yellowish, and transparent solid, consisting mainly of ladderlike polysilsesquioxane species. The specific conductivity (sigma) of the nonhydrolyzed MTMSPI(+)I(-) (no I(2)) was 0.23 mS/cm, while the activation energy (E(a)), determined from the Vogel-Tamman-Fulcher (VTF) relation, was 0.29 kJ/mol. After 56 days of aging the sigma value of the hydrolyzed MTMSPI(+)I(-) dropped to 0.11 mS/cm but the viscosity had already increased to 7500 Pa.s after 17 days, demonstrating that a quasi solid state was attained. Apparent diffusion coefficients (D(app)) of I(-) and I(3)(-) obtained from the voltammetric measurements were approximately 10(-7) cm(2)/s and decreased to approximately 10(-8) cm(2)/s after 15 days of sol aging. Time-dependent vibrational spectra, which served in assessing the hydrolysis and condensation reactions of MTMSPI(+)I(-), were measured with the help of the attenuated total reflectance (ATR) IR spectroscopic technique. The results revealed that, in the course of condensation of sols, the refractive index of the modes attributed to the polysilsesquioxane species exhibited strong dispersion, which led to a shift of the vibrational band position in the experimental ATR spectra. This effect accompanies the sol-to-gel transformations and has not yet been considered as a possible error in analysis of the ATR spectra of sols and gels. The calculation procedure for obtaining the corresponding transmission spectra is briefly outlined, and the results are applied in this work.


Assuntos
Iodetos/química , Íons/química , Compostos de Organossilício/química , Estrutura Molecular , Fotoquímica , Análise Espectral , Viscosidade , Água/química
14.
Anal Sci ; 18(3): 301-5, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11918189

RESUMO

The testing of various types of carbon paste electrodes (CPEs) for their use in stripping potentiometry was carried out by means of specially proposed procedures and by using various model analyte systems. CPEs containing three different pasting liquids (paraffin oil, silicone oil, tricresyl phosphate) were tested as supports for mercury- and gold films, and as substrates for electrolytic, adsorptive, ion-pair forming, and extractive accumulation. Test measurements in organic solvent-containing media and studies of some irreversible electrochemical reactions were performed as well. Individual examples to be studied allowed one to formulate and outline some perspectives of CPEs in potentiometric stripping analysis and related constant current stripping analysis.

15.
Anal Chim Acta ; 785: 43-9, 2013 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-23764442

RESUMO

New insights into the functioning, i.e. electrochemical behaviour and analytical performance, of in situ prepared antimony film electrodes (SbFEs) under square-wave anodic stripping (SW-ASV) and cyclic (CV) voltammetry conditions are presented by studying several key operational parameters using Pb(II), Cd(II) and Zn(II) as model analyte ions. Five different carbon- and metal-based substrate transducer electrodes revealed a clear advantage of the former ones while the concentration of the precursor Sb(III) ion exhibited a distinct influence on the ASV functioning of the SbFE. Among six acids examined as potential supporting electrolytes the HNO3 was demonstrated to yield nearly identical results in conducting ASV experiments with SbFE as so far almost exclusively used HCl. This is extremely important as HNO3 is commonly employed acidifying agent in trace metal analysis, especially in elemental mass spectrometry measurements. By carrying out a systematic CV and ASV investigation using a medium exchange protocol, we confirmed the formation of poorly soluble oxidized Sb species at the substrate electrode surface at the end of each stripping step, i.e. at the potentials beyond the anodic dissolution of the antimony film. Hence, the significance of the cleaning and initializing the surface of a substrate electrode after accomplishing a stripping step was thoroughly studied in order to find conditions for a complete removal of the adhered Sb-oxides and thus to assure a memory-free functioning of the in situ prepared SbFE. Finally, the practical analytical application of the proposed ASV method was successfully tested and evaluated by measuring the three metal analytes in ground (tap) and surface (river) water samples acidified with HNO3. Our results approved the appropriateness of the SbFE and the proposed method for measuring low µg L(-1) levels of some toxic metals, particularly taking into account the possibility of on-field testing and the use of low cost instrumentation.

16.
Anal Chim Acta ; 678(2): 176-82, 2010 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-20888449

RESUMO

This article reports on a novel microsensor for amperometric measurement of ascorbic acid (AA) under acidic conditions (pH 2) based on a carbon fiber microelectrode (CFME) modified with nickel oxide and ruthenium hexacyanoferrate (NiO-RuHCF). This sensing layer was deposited electrochemically in a two-step procedure involving an initial galvanostatic NiO deposition followed by a potentiodynamic RuHCF deposition from solutions containing the precursor salts. Several important parameters were examined to characterize and optimize the NiO-RuHCF sensing layer with respect to its current response to AA by using cyclic voltammetry, and scanning electron microscopy-energy dispersive X-ray spectroscopy methods. With the NiO-RuHCF coated CFME, the AA oxidation potential under acidic conditions was shifted to a less positive value for about 0.2 V (E(p) of ca. 0.23 V vs. Ag/AgCl) as compared to a bare CFME, which greatly improves the electrochemical selectivity. Using the hydrodynamic amperometry mode, the current vs. AA concentration in 0.01 M HCl, at a selected operating potential of 0.30 V, was found to be linear over a wide range of 10-1610 µM (n=22, r=0.999) with a calculated limit of detection of 1.0 µM. The measurement repeatability was satisfactory with a relative standard deviation (r.s.d.) ranging from 4% to 5% (n=6), depending on the AA concentration, and with a sensor-to-sensor reproducibility (r.s.d.) of 6.9% at 100 µM AA. The long-term reproducibility, using the same microsensor for 112 consecutive measurements of 20 µM AA over 11 h of periodic probing sets over 4 days, was 16.1% r.s.d., thus showing very good stability at low AA levels and suitability for use over a prolonged period of time. Moreover, using the proposed microsensor, additionally coated with a protective cellulose acetate membrane, the calibration plot obtained in the extremely complex matrix of real undiluted gastric juice was linear from 10 to 520 µM (n=14, r=0.998). These results demonstrated the unique featuring of the proposed NiO-RuHCF microsensor under acidic conditions with enhanced sensitivity and stability and proved its promising potentiality for direct amperometric probing of AA at physiological levels in real gastric juice environments.


Assuntos
Ácido Ascórbico/análise , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/métodos , Suco Gástrico/metabolismo , Ácido Ascórbico/química , Técnicas Biossensoriais/instrumentação , Calibragem , Carbono/química , Fibra de Carbono , Celulose/análogos & derivados , Celulose/química , Técnicas Eletroquímicas/instrumentação , Ferrocianetos/química , Suco Gástrico/química , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Microeletrodos , Microscopia Eletrônica de Varredura , Níquel/química , Reprodutibilidade dos Testes , Compostos de Rutênio/química , Espectroscopia por Absorção de Raios X
17.
Talanta ; 74(3): 405-11, 2007 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-18371656

RESUMO

The present paper demonstrates the preparation and characterization of micro-electrodes based on carbon paste which is composed of carbon nanoparticles with an average diameter of 30 nm and binding oil. The carbon paste electrode material is encased in pulled glass capillaries ranging in diameter from several tens down to less than ten micro-meters (r=4.5 microm). Manipulation of the carbon paste micro-electrode (CPME) was accomplished via newly developed piston-driven system which construction and related problems are presented. Several parameters influencing the CPME performance including carbon paste composition and its electrochemical activation/preconditioning were investigated. Basic electrochemical behavior and properties were examined using typical redox system, i.e. potassium hexacyanoferrate. Applicability of the proposed carbon paste micro-electrode is illustrated by measuring some potentially interesting organic and inorganic analytes such as dopamine, ascorbic acid and selected heavy metals.


Assuntos
Carbono/química , Eletroquímica/instrumentação , Nanopartículas/química , Óleos/química , Ácido Ascórbico/análise , Dopamina/análise , Metais Pesados/análise , Microeletrodos , Nanotubos de Carbono/química , Fuligem/química
18.
Anal Chem ; 79(22): 8639-43, 2007 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-17949057

RESUMO

In this work, an antimony film electrode (SbFE) is reported for the first time as a possible alternative for electrochemical stripping analysis of trace heavy metals. The SbFE was prepared in situ on a glassy carbon substrate electrode and employed in combination with either anodic stripping voltammetry or stripping chronopotentiometry in nondeaerated solutions of 0.01 M hydrochloric acid (pH 2). Several key operational parameters influencing the electroanalytical response of SbFE were examined and optimized, such as deposition potential, deposition time, and composition of the measurement solution. The SbFE exhibited well-defined and separated stripping signals for both model metal ions, Cd(II) and Pb(II), surrounded with low background contribution and a relatively large negative potential range. The electrode revealed good linear behavior in the examined concentration range from 20 to 140 microg L-1 for both test metal ions, with a limit of detection (3sigma) of 0.7 microg L-1 for Cd(II) and 0.9 microg L-1 for Pb(II) obtained after a 120 s deposition step, and good reproducibility, with a relative standard deviation (RSD) of +/-3.6% for Cd(II) and +/-6.2% for Pb(II) (60 microg L-1, n = 12). When comparing the SbFE with the commonly used mercury film electrode and recently introduced bismuth film electrode, the newly proposed electrode offers a remarkable performance in more acidic solutions (pH < or = 2), which can be advantageous in electrochemical analysis of trace heavy metals, hence contributing to the wider applicability of electrochemical stripping techniques in connection with "mercury-free" electrodes.

19.
Anal Chim Acta ; 580(2): 244-50, 2006 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-17723780

RESUMO

The bismuth film electrode (BiFE), in combination with anodic stripping voltammetry, offers convenient measurement of low concentrations of tin. The procedure involves simultaneous in situ formation of the bismuth film electrode on a glassy carbon substrate electrode, together with electrochemical deposition of tin, in a non-deaerated model solution containing bismuth ions, catechol as complexing agent and the metal analyte, followed by an anodic stripping scan. The BiFE is characterized by an attractive electroanalytical performance, with two distinct voltammetric stripping signals corresponding to tin, accompanied with low background contributions. Several experimental parameters were optimized, such as concentration of bismuth ions and catechol, deposition potential, deposition time and pH of the model solution. In addition, a critical comparison is given with bare glassy carbon and mercury film electrodes, revealing the superior characteristics of BiFE for measurement of tin. BiFE exhibited highly linear behavior in the examined concentration range from 1 to 100 microg L(-1) of tin (R2=0.997), an LoD of 0.26 microg L(-1) tin, and good reproducibility with a calculated R.S.D. of 7.3% for 10 microg L(-1) tin (n=10). As an example, the practical applicability of BiFE was tested with the measurement of tin in a real sample of seawater.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA