RESUMO
To improve the understanding of chemo-refractory high-grade serous ovarian cancers (HGSOCs), we characterized the proteogenomic landscape of 242 (refractory and sensitive) HGSOCs, representing one discovery and two validation cohorts across two biospecimen types (formalin-fixed paraffin-embedded and frozen). We identified a 64-protein signature that predicts with high specificity a subset of HGSOCs refractory to initial platinum-based therapy and is validated in two independent patient cohorts. We detected significant association between lack of Ch17 loss of heterozygosity (LOH) and chemo-refractoriness. Based on pathway protein expression, we identified 5 clusters of HGSOC, which validated across two independent patient cohorts and patient-derived xenograft (PDX) models. These clusters may represent different mechanisms of refractoriness and implicate putative therapeutic vulnerabilities.
Assuntos
Cistadenocarcinoma Seroso , Neoplasias Ovarianas , Proteogenômica , Feminino , Humanos , Cistadenocarcinoma Seroso/tratamento farmacológico , Cistadenocarcinoma Seroso/genética , Neoplasias Ovarianas/tratamento farmacológico , Neoplasias Ovarianas/genéticaRESUMO
Many peptide hormones form an α-helix on binding their receptors1-4, and sensitive methods for their detection could contribute to better clinical management of disease5. De novo protein design can now generate binders with high affinity and specificity to structured proteins6,7. However, the design of interactions between proteins and short peptides with helical propensity is an unmet challenge. Here we describe parametric generation and deep learning-based methods for designing proteins to address this challenge. We show that by extending RFdiffusion8 to enable binder design to flexible targets, and to refining input structure models by successive noising and denoising (partial diffusion), picomolar-affinity binders can be generated to helical peptide targets by either refining designs generated with other methods, or completely de novo starting from random noise distributions without any subsequent experimental optimization. The RFdiffusion designs enable the enrichment and subsequent detection of parathyroid hormone and glucagon by mass spectrometry, and the construction of bioluminescence-based protein biosensors. The ability to design binders to conformationally variable targets, and to optimize by partial diffusion both natural and designed proteins, should be broadly useful.
Assuntos
Desenho Assistido por Computador , Aprendizado Profundo , Peptídeos , Proteínas , Técnicas Biossensoriais , Difusão , Glucagon/química , Glucagon/metabolismo , Medições Luminescentes , Espectrometria de Massas , Hormônio Paratireóideo/química , Hormônio Paratireóideo/metabolismo , Peptídeos/química , Peptídeos/metabolismo , Estrutura Secundária de Proteína , Proteínas/química , Proteínas/metabolismo , Especificidade por Substrato , Modelos MolecularesRESUMO
The evaluation of biopsied solid organ tissue has long relied on visual examination using a microscope. Immunohistochemistry is critical in this process, labeling and detecting cell lineage markers and therapeutic targets. However, while the practice of immunohistochemistry has reshaped diagnostic pathology and facilitated improvements in cancer treatment, it has also been subject to pervasive challenges with respect to standardization and reproducibility. Efforts are ongoing to improve immunohistochemistry, but for some applications, the benefit of such initiatives could be impeded by its reliance on monospecific antibody-protein reagents and limited multiplexing capacity. This perspective surveys the relevant challenges facing traditional immunohistochemistry and describes how mass spectrometry, particularly liquid chromatography-tandem mass spectrometry, could help alleviate problems. In particular, targeted mass spectrometry assays could facilitate measurements of individual proteins or analyte panels, using internal standards for more robust quantification and improved interlaboratory reproducibility. Meanwhile, untargeted mass spectrometry, showcased to date clinically in the form of amyloid typing, is inherently multiplexed, facilitating the detection and crude quantification of 100s to 1000s of proteins in a single analysis. Further, data-independent acquisition has yet to be applied in clinical practice, but offers particular strengths that could appeal to clinical users. Finally, we discuss the guidance that is needed to facilitate broader utilization in clinical environments and achieve standardization.
Assuntos
Proteínas , Proteômica , Proteômica/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas , AnticorposRESUMO
Targeted mass spectrometry (MS)-based proteomic assays, such as multiplexed multiple reaction monitoring (MRM)-MS assays, enable sensitive and specific quantification of proteotypic peptides as stoichiometric surrogates for proteins. Efforts are underway to expand the use of MRM-MS assays in clinical environments, which requires a reliable strategy to monitor proteolytic digestion efficiency within individual samples. Towards this goal, extended stable isotope-labeled standard (SIS) peptides (hE), which incorporate native proteolytic cleavage sites, can be spiked into protein lysates prior to proteolytic (trypsin) digestion, and release of the tryptic SIS peptide (hT) can be monitored. However, hT measurements alone cannot monitor the extent of digestion and may be confounded by matrix effects specific to individual patient samples; therefore, they are not sufficient to monitor sample-to-sample digestion variability. We hypothesized that measuring undigested hE, along with its paired hT, would improve detection of digestion issues compared to only measuring hT. We tested the ratio of the SIS pair measurements, or hE/hT, as a quality control (QC) metric of trypsin digestion for two MRM assays: a direct-MRM (398 targets) and an immuno-MRM (126 targets requiring immunoaffinity peptide enrichment) assay, with extended SIS peptides observable for 54% (216) and 62% (78) of the targets, respectively. We evaluated the quantitative bias for each target in a series of experiments that adversely affected proteolytic digestion (e.g., variable digestion times, pH, and temperature). We identified a subset of SIS pairs (36 for the direct-MRM, 7 for the immuno-MRM assay) for which the hE/hT ratio reliably detected inefficient digestion that resulted in decreased assay sensitivity and unreliable endogenous quantification. The hE/hT ratio was more responsive to a decrease in digestion efficiency than a metric based on hT measurements alone. For clinical-grade MRM-MS assays, this study describes a ready-to-use QC panel and also provides a road map for designing custom QC panels.
Assuntos
Peptídeos , Proteômica , Humanos , Proteômica/métodos , Tripsina/química , Peptídeos/análise , Espectrometria de Massas/métodos , Controle de Qualidade , DigestãoRESUMO
A thorough evaluation of the quality, reproducibility, and variability of bottom-up proteomics data is necessary at every stage of a workflow, from planning to analysis. We share vignettes applying adaptable quality control (QC) measures to assess sample preparation, system function, and quantitative analysis. System suitability samples are repeatedly measured longitudinally with targeted methods, and we share examples where they are used on three instrument platforms to identify severe system failures and track function over months to years. Internal QCs incorporated at the protein and peptide levels allow our team to assess sample preparation issues and to differentiate system failures from sample-specific issues. External QC samples prepared alongside our experimental samples are used to verify the consistency and quantitative potential of our results during batch correction and normalization before assessing biological phenotypes. We combine these controls with rapid analysis (Skyline), longitudinal QC metrics (AutoQC), and server-based data deposition (PanoramaWeb). We propose that this integrated approach to QC is a useful starting point for groups to facilitate rapid quality control assessment to ensure that valuable instrument time is used to collect the best quality data possible. Data are available on Panorama Public and ProteomeXchange under the identifier PXD051318.
Assuntos
Proteômica , Controle de Qualidade , Proteômica/métodos , Proteômica/normas , Reprodutibilidade dos Testes , Humanos , Fluxo de Trabalho , Peptídeos/análise , Peptídeos/normasRESUMO
Estimating glomerular filtration rate (GFR) is important in daily practice to assess kidney function and adapting the best clinical care of patients with and without chronic kidney disease. The new creatinine-based European Kidney Function Consortium (EKFC) equation is used to estimate GFR. This equation was developed and validated mainly in European individuals and based on a rescaled creatinine, with the rescaling factor (Q-value) defined as the median normal value of serum creatinine in a given population. The validation was limited in Non-Black Americans and absent in Black Americans. Here, our cross-sectional analysis included 12,854 participants from nine studies encompassing large numbers of both non-Black and Black Americans with measured GFR by clearance of an exogenous marker (reference method), serum creatinine, age, sex, and self-reported race available. Two strategies were considered with population-specific Q-values in Black and non-Black men and women (EKFCPS) or a race-free Q-value (EKFCRF). In the whole population, only the EKFCPS equation showed no statistical median bias (0.14, 95% confidence interval [-0.07; 0.35] mL/min/1.73m2), and the bias for the EKFCRF (0.74, [0.51; 0.94] mL/min/1.73m2) was closer to zero than that for the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI2021) equation (1.22, [0.99; 1.47]) mL/min/1.73m2]. The percentage of estimated GFR within 30% of measured GFR was similar for CKD-EPI2021 (79.2% [78.5%; 79.9%]) and EKFCRF (80.1% [79.4%; 80.7%]), but improved for the EKFCPS equation (81.1% [80.5%; 81.8%]). Thus, our EKFC equations can be used to estimate GFR in the United States incorporating either self-reported race or unknown race at the patient's discretion per hospital registration records.
Assuntos
Cistatina C , Insuficiência Renal Crônica , Masculino , Humanos , Feminino , Estados Unidos , Creatinina , Estudos Transversais , Taxa de Filtração Glomerular , RimRESUMO
BACKGROUND: The enhanced precision and selectivity of liquid chromatography-tandem mass spectrometry (LC-MS/MS) makes it an attractive alternative to certain clinical immunoassays. Easily transferrable work flows could help facilitate harmonization and ensure high-quality patient care. We aimed to evaluate the interlaboratory comparability of antibody-free multiplexed insulin and C-peptide LC-MS/MS measurements. METHODS: The laboratories that comprise the Targeted Mass Spectrometry Assays for Diabetes and Obesity Research (TaMADOR) consortium verified the performance of a validated peptide-based assay (reproducibility, linearity, and lower limit of the measuring interval [LLMI]). An interlaboratory comparison study was then performed using shared calibrators, de-identified leftover laboratory samples, and reference materials. RESULTS: During verification, the measurements were precise (2.7% to 3.7%CV), linear (4 to 15â ng/mL for C-peptide and 2 to 14â ng/mL for insulin), and sensitive (LLMI of 0.04 to 0.10â ng/mL for C-peptide and 0.03â ng/mL for insulin). Median imprecision across the 3 laboratories was 13.4% (inter-quartile range [IQR] 11.6%) for C-peptide and 22.2% (IQR 20.9%) for insulin using individual measurements, and 10.8% (IQR 8.7%) and 15.3% (IQR 14.9%) for C-peptide and insulin, respectively, when replicate measurements were averaged. Method comparison with the University of Missouri reference method for C-peptide demonstrated a robust linear correlation with a slope of 1.044 and r2 = 0.99. CONCLUSIONS: Our results suggest that combined LC-MS/MS measurements of C-peptide and insulin are robust and adaptable and that standardization with a reference measurement procedure could allow accurate and precise measurements across sites, which could be important to diabetes research and help patient care in the future.
Assuntos
Peptídeo C , Insulina , Espectrometria de Massas em Tandem , Peptídeo C/sangue , Peptídeo C/análise , Humanos , Espectrometria de Massas em Tandem/métodos , Insulina/análise , Insulina/sangue , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Laboratórios/normas , Espectrometria de Massa com Cromatografia LíquidaRESUMO
Mass spectrometry (MS) assays offer exceptional capabilities in high multiplexity, specificity, and throughput. As proteomics technologies continue advancements to identify new disease biomarkers, transition of these innovations from research settings to clinical applications becomes imperative. To meet the rigorous regulatory standards of clinical laboratories, development of a clinical protein MS assay necessitates adherence to stringent criteria. To illustrate the process, this project focused on using thyroglobulin (Tg) as a biomarker and an immuno-multiple reaction monitoring (iMRM) MS-based assay as a model for establishing a Clinical Laboratory Improvement Amendments (CLIA) compliant laboratory within the Centers of Genomic and Precision Medicine, National Taiwan University. The chosen example also illustrates the clinical utility of MS assays to complement conventional immunoassay-based methods, particularly in cases where the presence of autoantibodies in 10-30% of patients hinders accuracy. The laboratory design entails a comprehensive coordination in spatial layout, workflow organization, equipment selection, ventilation systems, plumbing, electrical infrastructure, documentation procedures, and communication protocols. Practical aspects of the transformation process, including preparing laboratory facilities, testing environments, instrument validation, assay development and validation, quality management, sample testing, and personnel competency, are discussed. Finally, concordant results in proficiency testing demonstrate the harmonization with the University of Washington Medical Center and the quality assurance of the CLIA-equivalent Tg-iMRM MS assay established in Taiwan. The realization of this model protein MS assay in Taiwan highlights the feasibility of international joint development and provides a detailed reference map to expedite the implementation of more MS-based protein assays in clinical laboratories for patient care.
RESUMO
INTRODUCTION: Fibroblast growth factor 23 (FGF23) has direct effects on the vasculature and myocardium, and high levels of FGF23 are a risk factor for cardiovascular disease (CVD); however, the impact of FGF23 on CVD in primary proteinuric glomerulopathies has not been addressed. METHODS: The associations of baseline plasma intact FGF23 levels with resting blood pressure (BP) and lipids over time among adults and children with proteinuric glomerulopathies enrolled in the Nephrotic Syndrome Study Network (NEPTUNE) were analyzed using generalized estimating equation regression analyses. Models were adjusted for age, sex, glomerular diagnosis, follow-up time, estimated glomerular filtration rate, urine protein/creatinine ratio, obesity, and serum phosphorous levels. RESULTS: Two hundred and four adults with median FGF23 77.5 (IQR 51.3-119.3) pg/mL and 93 children with median FGF23 62.3 (IQR 44.6-83.6) pg/mL were followed for a median of 42 (IQR 20.5-54) months. In adjusted models, each 1 µg/mL increase in FGF23 was associated with a 0.3 increase in systolic BP index at follow-up (p < 0.001). Greater baseline FGF23 was associated with greater odds of hypertensive BP (OR = 1.0003; 95% CI 1.001-1.006, p = 0.03) over time. Compared to tertile 1, tertile 2 (OR = 2.1; 95% CI 1.12-3.99, p = 0.02), and tertile 3 (OR = 3; 95% CI 1.08-8.08, p = 0.04), FGF23 levels were associated with greater odds of hypertensive BP over time. Tertile 2 was associated with greater triglycerides compared to tertile 1 (OR = 48.1; 95% CI 4.4-91.9, p = 0.03). CONCLUSION: Overall, higher baseline FGF23 was significantly associated with hypertensive BP over time in individuals with proteinuric glomerulopathies. Further study of FGF23 as a therapeutic target for reducing CVD in proteinuric glomerular disease is warranted.
Assuntos
Doenças Cardiovasculares , Hipertensão , Adulto , Criança , Humanos , Pressão Sanguínea/fisiologia , Fator de Crescimento de Fibroblastos 23 , Fatores de Crescimento de Fibroblastos , Fatores de RiscoRESUMO
BACKGROUND: 25-hydroxyvitamin D[25(OH)D] may be a poor marker of vitamin D status due to variability in levels of vitamin D binding protein (VDBP). The vitamin D metabolite ratio (VMR) is the ratio of 24,25-dihydroxyvitamin D[24,25(OH)2D3] to 25(OH)D3 and has been postulated to reflect vitamin D sufficiency independent of variability in VDBP. Therapeutic plasma exchange (TPE) is a procedure that removes plasma, including VDBP, and may lower bound vitamin D metabolite concentrations. Effects of TPE on the VMR are unknown. METHODS: We measured 25(OH)D, free 25(OH)D, 1,25-dihydroxyvitamin D[1,25(OH)2D], 24,25(OH)2D3, and VDBP in persons undergoing TPE, before and after treatment. We used paired t-tests to assess changes in these biomarkers during a TPE procedure. RESULTS: Study participants (n = 45) had a mean age of 55 ± 16 years; 67% were female; and 76% were white. Compared to pretreatment concentrations, TPE caused a significant decrease in total VDBP by 65% (95%CI 60,70%), as well as all the vitamin D metabolites-25(OH)D by 66% (60%,74%), free 25(OH)D by 31% (24%,39%), 24,25(OH)2D3 by 66% (55%,78%) and 1,25(OH)2D by 68% (60%,76%). In contrast, there was no significant change in the VMR before and after a single TPE treatment, with an observed mean 7% (-3%, 17%) change in VMR. CONCLUSIONS: Changes in VDBP concentration across TPE parallel changes in 25(OH)D, 1,25(OH)2D, and 24,25(OH)2D3, suggesting that concentrations of these metabolites reflect underlying VDBP concentrations. The VMR is stable across a TPE session despite a 65% reduction in VDBP. These findings suggest that the VMR is a marker of vitamin D status independent of VDBP levels.
Assuntos
Proteína de Ligação a Vitamina D , Vitamina D , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Masculino , Biomarcadores , Plasmaferese , Plasma/metabolismoRESUMO
BACKGROUND: Patients with chronic kidney disease (CKD) have dysfunctional high-density lipoprotein (HDL) particles as compared with the general population. Understanding the lipid composition of HDL may provide mechanistic insight. We tested associations of estimated glomerular filtration rate (eGFR) and albuminuria with relative HDL abundance of ceramides, sphingomyelins, and phosphatidylcholines in participants with CKD. METHODS: We studied 490 participants with CKD from the Seattle Kidney Study. HDL was isolated from plasma; targeted lipidomics was used to quantify the relative abundance of ceramides, sphingomyelins, and phosphatidylcholines per 10 µg of total HDL protein. We evaluated the associations of eGFR and albuminuria with levels of individual lipids and lipid classes (including 7 ceramides, 6 sphingomyelins, and 24 phosphatidylcholines) using multivariable linear regression, controlling for multiple comparisons via the false discovery rate. RESULTS: The mean (SD) eGFR was 45 (24) mL/min/1.73 m2; the median (IQR[interquartile range]) albuminuria was 108 (16, 686) mg/g (12.2 [1.8, 77.6] mg/mmol) urine creatinine. After adjusting for demographics, past medical history, laboratory values, and medication use, eGFR was not associated with higher relative abundance of any class of lipids or individual lipids. Greater albuminuria was significantly associated with a higher relative abundance of total ceramides and moderate-long R-chain sphingomyelins, ceramides 22:0 and 24:1, hexosylceramide 16:0, sphingomyelin 16:0, and phosphatidylcholines 29:0, 30:1, and 38:2; the strongest association was for hexosylceramide 16:0 (increase per doubling of urine albumin to creatinine ratio 0.022 (95% CI, 0.012-0.032). CONCLUSIONS: Greater albuminuria was significantly associated with specific alterations in the lipid composition of HDL in participants with CKD.
Assuntos
Albuminúria , Insuficiência Renal Crônica , Humanos , Albuminúria/urina , Lipoproteínas HDL , Creatinina/urina , Esfingomielinas , Lipidômica , Taxa de Filtração Glomerular , Ceramidas , FosfatidilcolinasRESUMO
BACKGROUND: Medical results generated by European CE Marking for In Vitro Diagnostic or in-house tests should be traceable to higher order reference measurement systems (RMS), such as International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-endorsed reference measurement procedures (RMPs) and reference materials. Currently, serum apolipoprotein (a) [apo(a)] is recognized as a novel risk factor for cardiovascular risk assessment and patient management. The former RMS for serum apo(a) is no longer available; consequently, an International System of Units (SI)-traceable, ideally multiplexed, and sustainable RMS for apo(a) is needed. METHODS: A mass spectrometry (MS)-based candidate RMP (cRMP) for apo(a) was developed using quantitative bottom-up proteomics targeting 3 proteotypic peptides. The method was provisionally validated according to ISO 15193 using a single human serum based calibrator traceable to the former WHO-IFCC RMS. RESULTS: The quantitation of serum apo(a) was by design independent of its size polymorphism, was linear from 3.8 to 456 nmol/L, and had a lower limit of quantitation for apo(a) of 3.8 nmol/L using peptide LFLEPTQADIALLK. Interpeptide agreement showed Pearson Rs of 0.987 and 0.984 for peptides GISSTVTGR and TPENYPNAGLTR, and method comparison indicated good correspondence (slopes 0.977, 1.033, and 1.085 for LFLEPTQADIALLK, GISSTVTGR, and TPENYPNAGLTR). Average within-laboratory imprecision of the cRMP was 8.9%, 11.9%, and 12.8% for the 3 peptides. CONCLUSIONS: A robust, antibody-independent, MS-based cRMP was developed as higher order RMP and an essential part of the apo(a) traceability chain and future RMS. The cRMP fulfils predefined analytical performance specifications, making it a promising RMP candidate in an SI-traceable MS-based RMS for apo(a).
Assuntos
Peptídeos , Soro , Humanos , Apoproteína(a) , Espectrometria de Massas , Padrões de Referência , CalibragemRESUMO
BACKGROUND: Elevated concentrations of lipoprotein(a) [Lp(a)] are directly related to an increased risk of cardiovascular diseases, making it a relevant biomarker for clinical risk assessment. However, the lack of global standardization of current Lp(a) measurement procedures (MPs) leads to inconsistent patient care. The International Federation for Clinical Chemistry and Laboratory Medicine working group on quantitating apolipoproteins by mass spectrometry (MS) aims to develop a next-generation SI (International system of units)-traceable reference measurement system consisting of a MS-based, peptide-calibrated reference measurement procedure (RMP) and secondary serum-based reference materials (RMs) certified for their apolipoprotein(a) [apo(a)] content. To reach measurement standardization through this new measurement system, 2 essential requirements need to be fulfilled: a sufficient correlation among the MPs and appropriate commutability of future serum-based RMs. METHODS: The correlation among the candidate RMP (cRMP) and immunoassay-based MPs was assessed by measuring a panel of 39 clinical samples (CS). In addition, the commutability of 14 different candidate RMs was investigated. RESULTS: Results of the immunoassay-based MPs and the cRMPs demonstrated good linear correlations for the CS but some significant sample-specific differences were also observed. The results of the commutability study show that RMs based on unspiked human serum pools can be commutable with CS, whereas human pools spiked with recombinant apo(a) show different behavior compared to CS. CONCLUSIONS: The results of this study show that unspiked human serum pools are the preferred candidate secondary RMs in the future SI-traceable Lp(a) Reference Measurement System.
Assuntos
Química Clínica , Lipoproteína(a) , Humanos , Imunoensaio , Espectrometria de Massas , Padrões de ReferênciaRESUMO
BACKGROUND: APOE genotype is associated with Alzheimer disease. Thus, the concentration of apolipoprotein E (apoE) isoforms in cerebrospinal fluid (CSF) could be altered in dementia. However, conflicting results have been obtained in different studies. Carefully validated and standardized assays could improve the interpretation of research findings, allow their replication in other laboratories, and generalize their application. METHODS: To evaluate this hypothesis, we aimed to develop, validate, and standardize a new measurement procedure using LC-MS/MS. Purified recombinant apoE protein standards (E2, E3, E4) were thoroughly characterized and used to assign the concentration of a matrix-matched calibration material that contained each apoE isoform, which ensured the metrological traceability of results. RESULTS: The assay of each isoform in human CSF was precise (≤11%CV) and of moderate throughput (approximately 80 samples per day). It demonstrated good linearity and parallelism for lumbar CSF, ventricular CSF, and bovine CSF. The use of an SI-traceable matrix-matched calibrator enabled precise and accurate measurements. There was no association observed between total apoE concentration and the number of Æ4 alleles in a cohort of 322 participants. However, the concentration of each isoform was significantly different in heterozygotes, with E4 > E3 > E2. Isoform concentrations were associated with cognitive and motor symptoms but contributed negligibly to a predictive model of cognitive impairment that included established CSF biomarkers. CONCLUSIONS: Our method simultaneously measures each apoE isoform in human CSF with excellent precision and accuracy. A secondary matrix-matched material has been developed and is available to other laboratories to improve interlaboratory agreement.
Assuntos
Doença de Alzheimer , Apolipoproteína E4 , Humanos , Animais , Bovinos , Cromatografia Líquida , Apolipoproteína E4/genética , Apolipoproteína E4/líquido cefalorraquidiano , Espectrometria de Massas em Tandem , Apolipoproteínas E/genética , Doença de Alzheimer/líquido cefalorraquidiano , Isoformas de Proteínas , Peptídeos beta-Amiloides/líquido cefalorraquidianoRESUMO
OBJECTIVES: Vitamin D-binding protein (VDBP), a serum transport protein for 25-hydroxyvitamin D [25(OH)D], has three common proteoforms which have co-localized amino acid variations and glycosylation. A monoclonal immunoassay was found to differentially detect VDBP proteoforms and methods using liquid chromatography-tandem mass spectrometry (LC-MS/MS) might be able to overcome this limitation. Previously developed multiple reaction monitoring LC-MS/MS methods for total VDBP quantification represent an opportunity to probe the potential effects of proteoforms on proteolysis, instrument response and quantification accuracy. METHODS: VDBP was purified from homozygous human donors and quantified using proteolysis or acid hydrolysis and LC-MS/MS. An interlaboratory comparison was performed using pooled human plasma [Standard Reference Material® 1950 (SRM 1950) Metabolites in Frozen Human Plasma] and analyses with different LC-MS/MS methods in two laboratories. RESULTS: Several shared peptides from purified proteoforms were found to give reproducible concentrations [≤2.7% coefficient of variation (CV)] and linear instrument responses (R2≥0.9971) when added to human serum. Total VDBP concentrations from proteolysis or amino acid analysis (AAA) of purified proteoforms had ≤1.92% CV. SRM 1950, containing multiple proteoforms, quantified in two laboratories resulted in total VDBP concentrations with 7.05% CV. CONCLUSIONS: VDBP proteoforms were not found to cause bias during quantification by LC-MS/MS, thus demonstrating that a family of proteins can be accurately quantified using shared peptides. A reference value was assigned for total VDBP in SRM 1950, which may be used to standardize methods and improve the accuracy of VDBP quantification in research and clinical samples.
Assuntos
Espectrometria de Massas em Tandem , Proteína de Ligação a Vitamina D , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Proteólise , Vitamina D , Proteínas Sanguíneas/metabolismo , Aminoácidos/metabolismoRESUMO
BACKGROUND: Vitamin D deficiency is common in glomerular disease. Supplementation may be ineffective due to ongoing urinary losses of vitamin D binding protein. We sought to determine if daily cholecalciferol supplementation would increase vitamin D concentrations in children with glomerular disease and persistent proteinuria, without adverse effects. METHODS: Eighteen participants at least 5 years of age with primary glomerular disease and urine protein:creatinine ratio ≥ 0.5 were enrolled from four pediatric nephrology practices to receive cholecalciferol supplementation: 4,000 IU or 2,000 IU per day for serum 25 hydroxyvitamin vitamin D (25OHD) concentrations < 20 ng/mL and 20 ng/mL to < 30 ng/mL, respectively. Measures of vitamin D and mineral metabolism were obtained at baseline and weeks 6 and 12. Multivariable generalized estimating equation (GEE) regression estimated mean percent changes in serum 25OHD concentration. RESULTS: Median baseline 25OHD was 12.8 ng/mL (IQR 9.3, 18.9) and increased to 27.8 ng/mL (20.5, 36.0) at week 6 (p < 0.001) without further significant increase at week 12. A total of 31% of participants had a level ≥ 30 ng/mL at week 12. Supplementation was stopped in two participants at week 6 for mildly elevated calcium and phosphorus, respectively, with subsequent declines in 25OHD of > 20 ng/mL. In the adjusted GEE model, 25OHD was 102% (95% CI: 64, 141) and 96% (95% CI: 51, 140) higher versus baseline at weeks 6 and 12, respectively (p < 0.001). CONCLUSION: Cholecalciferol supplementation in vitamin D deficient children with glomerular disease and persistent proteinuria safely increases 25OHD concentration. Ideal dosing to fully replete 25OHD concentrations in this population remains unknown. CLINICAL TRIAL: NCT01835639. A higher resolution version of the Graphical abstract is available as Supplementary information.
Assuntos
Nefropatias , Deficiência de Vitamina D , Humanos , Criança , Adulto Jovem , Vitamina D , Colecalciferol/uso terapêutico , Vitaminas/uso terapêutico , Deficiência de Vitamina D/complicações , Deficiência de Vitamina D/tratamento farmacológico , Nefropatias/complicações , Suplementos Nutricionais , Proteinúria/etiologia , Proteinúria/complicaçõesRESUMO
OBJECTIVE: Case reports of postvaccine early-onset Graves' hyperthyroidism (PVGD) after the administration of COVID-19 vaccination have emerged. Our aim was to investigate whether the incidence of Graves' hyperthyroidism (GD) has increased after the introduction of COVID-19 vaccination. METHODS: We compared the incidence of new-onset GD at a single academic center during 2 periods: December 2017 to October 2019 and December 2020 to October 2022, ie, before and after the implementation of COVID-19 vaccinations. We defined PVGD as laboratory-confirmed hyperthyroidism and GD within 4 weeks after the vaccination or clear onset of symptoms of thyrotoxicosis within 4 weeks of vaccination with evidence of hyperthyroidism and GD within 3 months. RESULTS: During the prevaccination period, 803 patients carried diagnoses of GD, and of these, 131 were new. During the postvaccination period, 901 patients carried diagnoses of GD, and of these, 138 were new. There was no statistically significant difference in the incidence of GD (P = .52), age at onset, gender, or race between the 2 groups. Twenty-four of 138 newly diagnosed patients in the post-COVID-19 group met the criteria for PVGD. The median free T4 was higher, but this was not statistically significant (3.9 vs 2.5 ng/dL, P = .05). There were no differences in age, gender, race, antibody titers, or type of vaccination between PVGD and controls. CONCLUSION: There was no increase in new-onset GD after COVID-19 vaccination. Median free T4 was higher in patients with PVGD, but this was not statistically significant.
Assuntos
COVID-19 , Doença de Graves , Hipertireoidismo , Humanos , Doença de Graves/epidemiologia , Doença de Graves/diagnóstico , Incidência , Vacinas contra COVID-19 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Hipertireoidismo/epidemiologiaRESUMO
BACKGROUND: People with chronic kidney disease (CKD) are at high risk for cognitive impairment and progressive cognitive decline. Retention of protein-bound organic solutes that are normally removed by tubular secretion is hypothesized to contribute to cognitive impairment in CKD. METHODS: We followed 2362 participants who were initially free of cognitive impairment and stroke in the prospective Chronic Renal Insufficiency Cohort (CRIC) Study. We estimated tubular secretory clearance by the 24-hour kidney clearances of eight endogenous solutes that are primarily eliminated by tubular secretion. CRIC study investigators assessed participants' cognitive function annually using the Modified Mini-Mental State (3MS) Examination. Cognitive decline was defined as a sustained decrease of more than five points in the 3MS score from baseline. Using Cox regression models adjusted for potential confounders, we analyzed associations between secretory solute clearances, serum solute concentrations, and cognitive decline. RESULTS: The median number of follow-up 3MS examinations was six per participant. There were 247 incident cognitive decline events over a median of 9.1 years of follow-up. Lower kidney clearances of five of the eight secretory solutes (cinnamoylglycine, isovalerylglycine, kynurenic acid, pyridoxic acid, and tiglylglycine) were associated with cognitive decline after adjustment for baseline eGFR, proteinuria, and other confounding variables. Effect sizes ranged from a 17% to a 34% higher risk of cognitive decline per 50% lower clearance. In contrast, serum concentrations of the solutes were not associated with cognitive decline. CONCLUSIONS: Lower kidney clearances of secreted solutes are associated with incident global cognitive decline in a prospective study of CKD, independent of eGFR. Further work is needed to determine the domains of cognition most affected by decreased secretory clearance and the mechanisms of these associations.
Assuntos
Disfunção Cognitiva , Insuficiência Renal Crônica , Cognição , Disfunção Cognitiva/etiologia , Taxa de Filtração Glomerular , Humanos , Testes de Função Renal , Estudos ProspectivosRESUMO
A 58-year-old woman with debilitating ankylosing spondylitis who was born to consanguineous parents was found to have an apparent severe vitamin D deficiency that did not respond to supplementation. Liquid chromatography-tandem mass spectrometry showed the absence of circulating vitamin D-binding protein, and chromosomal microarray confirmed a homozygous deletion of the group-specific component (GC) gene that encodes the protein. Congenital absence of vitamin D-binding protein resulted in normocalcemia and a relatively mild disruption of bone metabolism, in this case complicated by severe autoimmune disease. (Funded by the National Institutes of Health and the University of Washington.).