Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
J Arthroplasty ; 39(9S1): S24-S28, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38467203

RESUMO

BACKGROUND: Advances in total hip arthroplasty (THA) have resulted in evolving revision indications and intraoperative techniques, which can influence the exposure of trainees to complex cases. We report 3 decades of revision experience from a tertiary referral center that trains fellows, comparing the reasons for revision and the complexity of revisions over time. METHODS: We retrospectively reviewed all revision THAs performed at our institution from 1990 to 2022. Revision diagnoses, components revised, types of revision implants used, and exposure techniques were collected. A "complex" revision was defined as a case that involved an extended trochanteric osteotomy, triflange and cup-cage construct, or acetabular augment. RESULTS: A total of 3,556 THA revisions were identified (108 revisions/year). Aseptic loosening was the most common indication in 1990 to 1999 (45 per year), but decreased to 28.3/year in 2010 to 2019. From 1990 to 1999 and 2010 to 2019, fracture increased from 3.1 to 7.3 per year, infection from 2.9/year to 16.9/year, and metallosis from 0.1 to 13.2 per year. Both component revision were common from 1990 to 1994 (42.6 per year), while polyethylene exchange was most common in 2010 to 2019 (43.3 per year). A decrease was observed in "complex" cases over time: 14.8 extended trochanteric osteotomies/year in 2000 to 2004 compared to 5.4 per year in 2018 to 2022, 4.5 triflange and cup-cage constructs/year in 2004 to 2007 compared to 0.8 per year in 2018 to 2022, and 4 acetabular augments per year in 2009 to 2012 compared to 1 per year in 2018 to 2022. CONCLUSIONS: Indications for revision have changed over the decades, while the number of "complex" revisions has gradually decreased, presumably due to advances in implants and materials. If this trend extends to other training institutions, the next generation of arthroplasty surgeons will have less exposure to complex revisions during their training.


Assuntos
Artroplastia de Quadril , Distinções e Prêmios , Falha de Prótese , Reoperação , Humanos , Reoperação/estatística & dados numéricos , Estudos Retrospectivos , Masculino , Feminino , Prótese de Quadril , Pessoa de Meia-Idade , Idoso
2.
J Arthroplasty ; 38(6S): S308-S313.e2, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36990369

RESUMO

BACKGROUND: Infection following total knee arthroplasty (TKA) remains a challenging clinical problem. Using American Joint Replacement Registry data, this study examined factors related to the incidence and timing of infection. METHODS: Primary TKAs performed from January 2012 through December 2018 among patients ≥65 years of age at surgery were queried from the American Joint Replacement Registry and merged with Medicare data to enhance capture of revisions for infection. Multivariate Cox regressions incorporating patient, surgical, and institutional factors were used to produce hazard ratios (HRs) associated with revision for infection and mortality after revision for infection. RESULTS: Among 525,887 TKAs, 2,821 (0.54%) were revised for infection. Men had an increased risk of revision for infection at all-time intervals (≤90 days, HR = 2.06, 95% CI: 1.75-2.43, P < .0001; >90 days to 1 year, HR = 1.90, 95% CI: 1.58-2.28, P < .0001; >1 year, HR = 1.57, 95% CI: 1.37-1.79, P < .0001). TKAs performed for osteoarthritis had an increased risk of revision for infection at ≤90 days (HR = 2.01, 95% CI: 1.45-2.78, P < .0001) but not at later times. Mortality was more likely among patients who had a Charlson Comorbidity Index (CCI) ≥ 5 compared to those who had a CCI ≤ 2 (HR = 3.21, 95% CI: 1.35-7.63, P = .008). Mortality was also more likely among older patients (HR = 1.61 for each decade, 95% CI: 1.04-2.49, P = .03). CONCLUSION: Based on primary TKAs performed in the United States, men were found to have a persistently higher risk of revision for infection, while a diagnosis of osteoarthritis was associated with a significantly higher risk only during the first 90 days after surgery.


Assuntos
Artroplastia do Joelho , Artroplastia de Substituição , Prótese do Joelho , Osteoartrite do Joelho , Masculino , Humanos , Idoso , Estados Unidos/epidemiologia , Artroplastia do Joelho/efeitos adversos , Dados de Saúde Coletados Rotineiramente , Reoperação , Falha de Prótese , Medicare , Osteoartrite do Joelho/cirurgia , Osteoartrite do Joelho/etiologia , Sistema de Registros , Fatores de Risco , Prótese do Joelho/efeitos adversos
3.
J Arthroplasty ; 37(3): 495-500, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34774686

RESUMO

BACKGROUND: One purported benefit of the direct anterior approach (DAA) for total hip arthroplasty (THA) is a lower rate of postoperative dislocation. METHODS: An institutional database was used to identify 8840 primary THAs performed from 2003 to 2020 including 5065 (57%) performed using the DAA and 3775 (43%) performed via the posterior approach (PA). Direction and mechanism of dislocation were determined from chart review. Outcomes were compared using Kaplan-Meier survivorship with dislocation as the endpoint and a Cox multivariate regression was used to investigate factors associated with dislocation. The mean follow-up was 1.7 ± 2.0 years for the DAA and 3.1 ± 3.3 years for the PA. RESULTS: The 0.5% (26/5065) incidence of dislocation among DAA hips was significantly less than the 3.3% (126/3775) among PA cases (P < .001). The majority of dislocations were posterior (DAA 57%, PA 79%) and occurred during activities of daily living (DAA 82%, PA 77%). Five-year survivorship was significantly higher for the DAA group compared to the PA group (99.1% vs 95.4%, P < .001). Dislocation risk was 4.9 times higher for the PA compared to the DAA (hazard ratio = 4.9, 95% confidence interval = 3.2-7.5, P < .001). Increasing head diameter reduced the risk (hazard ratio = 0.70, 95% confidence interval = 0.57-0.86, P < .001). The 0.2% incidence (10/5065) of revision for instability among the DAA group was significantly lower than the 1.1% (43/3775) rate for the PA group (P < .001). CONCLUSION: Compared to primary THAs performed with the PA, DAA cases had a lower risk of dislocation, higher survivorship with dislocation as an endpoint, and a lower risk of revision for instability in this single institution cohort.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Atividades Cotidianas , Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Luxação do Quadril/prevenção & controle , Humanos , Reoperação , Estudos Retrospectivos
4.
J Arthroplasty ; 37(2): 336-341, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34655761

RESUMO

BACKGROUND: Revision total hip arthroplasty with modular component exchange can limit morbidity by retaining well-fixed components but dislocation has been a relatively frequent postoperative complication. This study evaluated the effect of surgical approach on dislocation rate in a modern revision cohort. METHODS: From 2010 to 2020, 248 aseptic head and liner exchanges were performed at a single institution. The mean patient age at revision was 64.9 ± 10.4 years and 50% (123/248) were performed among males. Indications for revision included 140 (56%) for polyethylene wear, 68 (27%) for failed metal-on-metal components, and 40 (16%) for instability. The mean follow-up after revision was 2.3 years. RESULTS: Thirty (12%) hips dislocated at a mean of 0.6 years (range 0.01-4.6) postoperatively. The dislocation rate by revision approach was 17% (9/54) for the direct anterior, 6% (5/80) for the direct lateral, and 14% (16/114) for the posterolateral approach (P = .13). Hips revised by the direct anterior approach that dislocated were more abducted (51 ± 8 vs 45 ± 8, P = .05) and more anteverted (26 ± 9 vs 20 ± 7, P = .04) than non-dislocators. Among all 248 hips, cups with more than 48° of abduction were 2.6 times more likely to dislocate (P = .01). Head diameter, neck length, patient age, and gender were not associated with dislocation (P ≥ .20). CONCLUSION: Dislocation remains a common complication after head and liner exchange regardless of approach. Cup position is associated with postoperative instability and must be critically evaluated during preoperative planning.


Assuntos
Artroplastia de Quadril , Luxação do Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Luxação do Quadril/epidemiologia , Luxação do Quadril/etiologia , Luxação do Quadril/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Polietileno , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
5.
J Arthroplasty ; 37(6): 1203-1209, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35183710

RESUMO

BACKGROUND: Mobile bearing designs are intended to reduce wear, but mixed results were reported from retrieval analyses. Postmortem evaluation (PM) provides the opportunity to assess polyethylene damage in successful implants. We compared damage patterns, MRI presentation, and histology between mobile-bearing and fixed tibial inserts retrieved postmortem and compared these results to our prior findings from implants retrieved at revision. METHODS: Eleven postmortem knees with rotating platform (RP) implants and 13 with fixed bearing (FB) implants were examined. All were MRI scanned, and tissue samples were collected from standardized regions for histology. Polyethylene inserts were subjectively scored to assess articular, backside, and PS post surfaces for damage modes and severity. RESULTS: Average duration of implantation was 9.3 years (1.7-19.6 years). Surface burnishing was the most common polyethylene damage mode. Average damage scores were higher for RP (53.4) compared to FB inserts (34.4) due to greater backside damage (13.4 for RP vs 1.4 for FB). A minimal difference in damage was observed on the articular surfaces (37.4 RP vs 30.0 FB). Mild innate macrophage reactions were seen in 8 (72.7%) RP and 5 (45.5%) FB specimens. Polyethylene particles were identified in 7 (63.6%) RP and 3 (27.7%) FB specimens. CONCLUSIONS: Postmortem inserts showed low damage levels and mild tissue reactions compared to those reported for implants removed at revision arthroplasty. Nonetheless, trends in comparing RP and FB inserts were consistent with those seen in retrieval analyses, demonstrating the usefulness of retrieval studies in capturing performance differences among TKA designs.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Estresse Mecânico
6.
J Arthroplasty ; 36(12): 3883-3887, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34489145

RESUMO

BACKGROUND: To assess how implant alignment affects unicompartmental knee arthroplasty (UKA) outcome, we compared tibial component alignment of well-functioning UKAs against 2 groups of failed UKAs, revised for progression of lateral compartment arthritis ("Progression") and aseptic loosening ("Loosening"). METHODS: We identified 37 revisions for Progression and 61 revisions for Loosening from our prospective institutional database of 3351 medial fixed-bearing UKAs performed since 2000. Revision cohorts were matched on age, gender, body mass index, and postoperative range of motion with "Successful" unrevised UKAs with minimum 10-year follow-up and Knee Society Score ≥70. Tibial component coronal (TCA) and sagittal (TSA) plane alignment was measured on postoperative radiographs. Limb alignment was quantified by hip-knee-ankle (HKA) angle on long-leg radiographs. In addition to directly comparing groups, a multivariate logistic regression examined how limb and component alignments were associated with UKA revision. RESULTS: In the Progression group, component alignment was similar to the matched successes (TCA 3.6° ± 3.5° varus vs 5.1° ± 3.5° varus, P = .07; TSA 8.4° ± 4.4° vs 8.8° ± 3.6°, P = .67), whereas HKA angle was significantly more valgus (0.3° ± 3.6° valgus vs 4.4° ± 2.6° varus, P < .001). Loosening group component alignment was also similar to the matched successes (TCA 6.1° ± 3.7° varus vs 5.9° ± 3.1° varus, P = .72; TSA 8.4° ± 4.6° vs 8.1° ± 3.9°, P = .68), and HKA was significantly more varus (6.1° ± 3.1° varus vs 4.0° ± 2.7° varus, P < .001). Using a multivariate logistic regression, HKA angle was the most significant factor associated with revision (P < .001). CONCLUSION: In this population of revised UKAs and long-term successes, limb alignment was a more important determinant of outcome than tibial component alignment. LEVEL OF EVIDENCE: Level III case-control study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Estudos de Casos e Controles , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Perna (Membro) , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Estudos Retrospectivos
7.
J Arthroplasty ; 35(2): 353-357, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31668526

RESUMO

BACKGROUND: To better define the optimal alignment target for medial fixed-bearing unicompartmental knee arthroplasty (UKA), this study compares the postoperative mechanical alignment of well-functioning UKAs against 2 groups of failed UKAs, including revisions for progression of lateral compartment osteoarthritis ("Progression") and revisions for aseptic loosening or subsidence ("Loosening"). METHODS: From our prospective institutional database of 3351 medial fixed-bearing UKAs performed since 2000, we identified 37 UKAs revised for Progression and 61 UKAs revised for Loosening. Each of these revision cohorts was matched based on age at surgery, gender, body mass index, and postoperative range of motion with unrevised UKAs that had at least 10 years of follow-up and a Knee Society Score of 70 or greater without subtracting points for alignment ("Success" groups). Postoperative alignment was quantified by the hip-knee-ankle (HKA) angle measured on long-leg alignment radiographs. RESULTS: The mean HKA angle at 4-month follow-up for the Progression group was 0.3° ± 3.6° of valgus compared to 4.4° ± 2.6° of varus for the matched Success group (P < 0.001). For the Loosening group, the mean HKA angle was 6.1° ± 3.1° of varus versus 4.0° ± 2.7° of varus for the matched Success group (P < 0.001). CONCLUSIONS: Patients with well-functioning UKAs at 10 years exhibited mild varus mechanical alignment of approximately 4°, whereas patients revised for progression of osteoarthritis averaged more valgus and those revised for loosening or subsidence averaged more varus. The optimal mechanical alignment for medial fixed-bearing UKA survival with contemporary polyethylene is likely slight varus.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
8.
J Arthroplasty ; 35(5): 1208-1213, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31987687

RESUMO

BACKGROUND: The hypothetical association between health-care errors and the transition of the medical academic year has been termed the "July effect." Data supporting its existence are conflicting, particularly in orthopedic surgery, and prior studies have inappropriately grouped fellows with resident trainees. No studies to date have examined whether a training initiation effect exists among surgical fellows in adult reconstructive orthopedics. METHODS: This is a level IV retrospective cohort study reviewing 15,650 primary hip and knee arthroplasties performed from 2006 to 2016 at a single institution. Forty arthroplasty fellows were trained during this 10-year period. Primary outcome measures included intraoperative complications, additional procedures, revisions, and nonoperative complications within 90 days of surgery. These complication rates were analyzed by quarter of academic year and by temporal progression through three-month fellowship rotations. RESULTS: There were no differences in intraoperative complication, revision, or nonoperative complication rates between any academic quarter. There was a single statistically lower rate of additional procedures in the third quarter (1.2%) than in the fourth quarter (1.8%, P = .04). The most common complication in this subset was wound dehiscence for patients undergoing hip arthroplasty and stiffness for patients undergoing knee arthroplasty. There was no difference in complication rates during the first, second, or third month as fellows progressed through a single rotation. CONCLUSION: This study does not support the existence of a training-initiation effect among fellows in adult hip and knee reconstruction. Graduated autonomy can be safely employed in a fellowship program without negatively impacting patient outcomes, ensuring the continued high-caliber training of future surgeons.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Internato e Residência , Ortopedia , Adulto , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Bolsas de Estudo , Humanos , Ortopedia/educação , Estudos Retrospectivos
9.
J Arthroplasty ; 34(10): 2284-2289, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31176563

RESUMO

BACKGROUND: The Bundled Payments for Care Improvement (BPCI) initiative was introduced in 2013 to reduce Medicare healthcare costs while preserving or enhancing quality. We examined data from a metropolitan healthcare system comprised of 1 higher volume hospital and 4 lower volume hospitals that voluntarily elected to participate in the BPCI Major Joint Replacement of the Lower Extremity Model 2, beginning July 1, 2015. Stratifying the data by hospital volume, we determined how costs changed during the 16-month period when all 5 hospitals participated compared to the 1-year period preceding BPCI participation, where savings were achieved, and how the hospitals were rewarded. METHODS: The Medicare data included the 90-day target for each episode and actual part A and part B spending for the anchor hospitalization plus all post-acute payments including inpatient rehabilitation, skilled nursing, home health, outpatient physical therapy, and hospital readmissions. RESULTS: The mean episode of care cost decreased by 11.1% (from $21,324 to $18,953) at the higher volume hospitals and by 8.3% (from $25,724 to $23,584) at the lower volume hospitals during BPCI participation compared to the preceding year. The savings were achieved by reducing the use of inpatient rehabilitation, shortening the length of stay at skilled nursing facilities, and decreasing readmission rates. Although the higher volume hospital achieved an increased mean savings of $230 per episode compared to the lower volume hospitals ($2371 vs $2141), it was penalized $490 per episode after reconciling the actual Medicare expenditures with the BPCI targets while the lower volume hospitals received a mean reward of $315 per episode. CONCLUSION: The BPCI initiative decreased costs and readmissions within our healthcare system. Despite substantial savings compared to the preceding year, the higher volume hospital's low target derived from its 2009-2012 baseline costs was not achieved which resulted in a penalty and led it to withdraw from the BPCI initiative in October 2016.


Assuntos
Artroplastia de Substituição/economia , Redução de Custos/estatística & dados numéricos , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Hospitais com Baixo Volume de Atendimentos/economia , Pacotes de Assistência ao Paciente/economia , Idoso , Idoso de 80 Anos ou mais , Atenção à Saúde , Feminino , Custos de Cuidados de Saúde , Gastos em Saúde , Hospitalização , Hospitais com Baixo Volume de Atendimentos/estatística & dados numéricos , Humanos , Extremidade Inferior , Masculino , Assistência Médica , Medicare/economia , Pessoa de Meia-Idade , Readmissão do Paciente/economia , Readmissão do Paciente/estatística & dados numéricos , Instituições de Cuidados Especializados de Enfermagem/economia , Estados Unidos
10.
Clin Orthop Relat Res ; 476(2): 279-290, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29529656

RESUMO

BACKGROUND: Crosslinked polyethylene (XLPE) liners used for primary THA have demonstrated lower wear rates than noncrosslinked, conventional polyethylene (CPE) liners through the first decade of clinical service. However, little high-quality evidence is currently available regarding the second decade performance of these implants and it remains uncertain whether the onset of osteolysis has simply been delayed or if the wear associated with XLPE liners will remain low enough that osteolysis will not occur. It is also unknown how the potential reductions in wear and osteolysis will influence long-term revision rates. QUESTIONS/PURPOSES: Do patients who underwent THA with XLPE liners demonstrate (1) a lower rate of revision for wear-related complications; (2) a reduced wear rate; and (3) a lower frequency of osteolysis compared with those with CPE liners? METHODS: Over an 18-month period from 1999 to 2000, 226 patients who had 236 primary THAs consented to participate in a randomized controlled trial conducted at one institution. To be eligible for intraoperative randomization, patients had to be implanted with a 28-mm cobalt-chrome alloy femoral head, a 4-mm lateralized liner, and the same cup and stem design. Six patients with six THAs were excluded intraoperatively because they did not receive study components for reasons unrelated to the liner material. The remaining 230 THAs among 220 patients were randomized to XLPE liners or CPE liners. The mean age at surgery was 62 ± 11 years and there were no differences in age, gender, or body mass index among the groups. There was no differential loss to followup between the study groups; among patients not known to be deceased or having undergone revision, minimum 14-year radiographic followup is available for 85 THAs including 46 with XLPE and 39 with CPE liners. Polyethylene wear was measured radiographically using Martell's Hip Analysis Suite and areas of osteolysis were evaluated before revision or at most recent followup. Revision rates at 15 years using reoperation for any reason and revision for wear or osteolysis were calculated using cumulative incidence considering patient death as a competing risk. RESULTS: The cumulative incidence of revision at 15 years using reoperation for wear-related complications as an endpoint was lower in the XLPE group than the CPE group (0%, 95% confidence interval [CI], 0%-0% versus 12%, 95% CI, 7%-19%; p < 0.001). Among unrevised THAs with minimum 14-year radiographic followup, the mean steady-state linear wear rate for THAs with XLPE liners was lower than the mean linear wear rate for the THAs with CPE liners (0.03 ± 0.05 versus 0.17 ± 0.09 mm/year; mean difference, 0.14; 95% CI, 0.11-0.17; p < 0.001). Osteolysis of any size was noted among 9% (four of 46) of the hips in the XLPE group and 46% (18 of 39) of the hips in the CPE group (odds ratio, 0.19; 95% CI, 0.07-0.51; p < 0.001). CONCLUSIONS: This randomized study with followup into the second decade demonstrated reductions in revision, wear, and osteolysis associated with the use of XLPE. The low wear rates and absence of any mechanical failures among the XLPE liners at long-term followup affirm the durability of these components that did not incorporate antioxidants. Although osteolysis has not been eliminated, it occurs infrequently and has not caused any clinical problems to date. LEVEL OF EVIDENCE: Level I, therapeutic study.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Reagentes de Ligações Cruzadas/química , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteólise/prevenção & controle , Polietileno/química , Falha de Prótese , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Osteólise/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Proteção , Reoperação , Fatores de Risco , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Virginia
11.
Clin Orthop Relat Res ; 476(10): 2017-2024, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29912743

RESUMO

BACKGROUND: Our understanding of fretting and corrosion at head-neck junctions in modular THAs in vivo is based largely on the analysis of retrieved implants removed for various diagnoses. Little is known about the condition of head-neck tapers in well-functioning THAs. QUESTIONS/PURPOSES: Regarding a cohort of well-functioning autopsy-retrieved modular THAs, we asked: (1) Does trunnion geometry or femoral head material affect the pull-off force of the femoral head? (2) Is there a relationship between trunnion damage and length of implantation time, head diameter, and neck length? (3) Does visual damage scoring accurately determine the presence or absence of corrosion on cobalt-chrome trunnions? METHODS: Sixty-six femoral stems and engaged femoral heads were retrieved at autopsy from 53 patients at Anderson Orthopaedic Research Institute from 1998 to 2014. Ten stems were excluded for low stem design group size or insufficient head-stem clearance for pull-off testing, leaving a cohort of 56 THAs with a median implantation time of 10 years (range, 1-24 years). The femoral stems included three cobalt-chrome (CoCr) designs from a single manufacturer with either a 12/14 or 14/16 trunnion design (N = 36 and 20, respectively) mated with alumina or CoCr heads (N = 13 and 43, respectively). The force required to pull off the femoral heads was measured using a uniaxial load frame according to ASTM F2009-00. Mating surfaces were visually examined to assess the presence and severity of fretting and corrosion using a modified Goldberg scoring system. Three 12/14 trunnions of similar implantation lengths and varied damage scores were selected for imaging with a scanning electron microscope (SEM) and energy dispersive x-ray analysis (EDAX) to confirm the absence or presence of corrosion damage. RESULTS: No difference was seen in pull-off force between groups based on trunnion geometry and head material (median [range], alumina-12/14: 3127 [2320-6992] N, alumina-14/16: 2670 [1095-7919] N, CoCr-12/14: 2255 [1332-5939] N, CoCr-14/16: 2812 [1655-4246] N; p = 0.132). A positive correlation was found between damage score and length of implantation (ρ = 0.543, p < 0.001). However, no correlation between damage score and either head diameter or neck length was found (ρ = -0.012, p = 0.930 and ρ < 0.001, p = 0.995, respectively). In all, 39 of 56 specimens demonstrated no fretting or corrosion, and 16 specimens had mild damage scores. One specimen demonstrated severe corrosion without visual evidence of fretting. The presence of intergranular corrosion on this trunnion was determined by SEM imaging and EDAX. The absence of corrosion products on two trunnions with no observed damage was confirmed. CONCLUSIONS: This study found little evidence of fretting and corrosion in a cohort of well-functioning CoCr-CoCr and alumina-CoCr head-neck couples. Further studies are necessary to characterize fretting and corrosion at head-neck junctions of well-functioning implants of other designs and manufacturers. CLINICAL RELEVANCE: The results from this study suggest that patients with well-functioning THAs using polyethylene bearing surfaces with alumina or CoCr heads appear to be at low risk for trunnion corrosion for the specific CoCr alloy stems and trunnion geometries analyzed here.


Assuntos
Óxido de Alumínio/química , Artroplastia de Quadril/instrumentação , Ligas de Cromo/química , Remoção de Dispositivo , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Autopsia , Corrosão , Feminino , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Polietileno/química , Desenho de Prótese , Estudos Retrospectivos , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo , Adulto Jovem
12.
J Arthroplasty ; 33(7S): S8-S12, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29452974

RESUMO

BACKGROUND: Scrutiny from the federal government and the media regarding the safety of 1 surgeon doing cases in 2 operating rooms (ORs) on the same day, prompted us to examine our own institutional data. Over the past 11 years, surgeons at our facility have operated consecutively in 1 OR on a given day or used 2 alternating ORs. This study compares these cases with a focus on revisions and complications in both groups. METHODS: Six surgeons performed a total of 16,916 primary hip and knee arthroplasties from 2006-2016. 7002 cases (41%) were consecutive cases (CCs) and 9914 cases (59%) were overlapping cases (OCs). Intraoperative complications, component revisions, and postoperative complications within 90 days of surgery were compared between the CC and OC groups. RESULTS: There was no difference in intraoperative complication rates between the two groups (CC 1.6% vs. OC 1.7%, relative risk 1.082, 95% confidence interval 0.852 to 1.375, P = .52). There was no difference in 90-day component revision rates among the CC and OC groups (0.66% vs. 0.85% respectively, relative risk = 1.290, 95% confidence interval 0.901 to 1.845, P = .19). There was also no difference in 90-day complication rates among the CC and OC groups (1.33% vs. 1.45% respectively, relative risk = 1.094, 95% confidence interval 0.844 to 1.417, P = .54). CONCLUSION: This large study of a single institution with multiple surgeons over an 11-year period shows no compromise in patient safety or outcomes when comparing cases done in either consecutive or overlapping rooms.


Assuntos
Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Salas Cirúrgicas/organização & administração , Segurança do Paciente , Admissão e Escalonamento de Pessoal , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Distinções e Prêmios , Índice de Massa Corporal , Feminino , História do Século XXI , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Ortopedia/história , Estudos Retrospectivos , Fatores de Risco , Cirurgiões
13.
Clin Orthop Relat Res ; 475(2): 364-372, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27287858

RESUMO

BACKGROUND: Length of stay after total hip arthroplasty (THA) has decreased over the last two decades. However, published studies that have examined same-day and early discharge protocols after THA have been done in highly selected patient groups operated on by senior surgeons in a nonrandomized fashion without control subjects. QUESTIONS/PURPOSES: The purpose of this study was to evaluate and compare patients undergoing THA who are discharged on the same day as the surgery ("outpatient," less than 12-hour stay) with those who are discharged after an overnight hospital stay ("inpatient") with regard to the following outcomes: (1) postoperative pain; (2) perioperative complications and healthcare provider visits (readmission, emergency department or physician office); and (3) relative work effort for the surgeon's office staff. METHODS: A prospective, randomized study was conducted at two high-volume adult reconstruction centers between July 2014 and September 2015. Patients who were younger than 75 years of age at surgery, who could ambulate without a walker, who were not on chronic opioids, and whose body mass index was less than 40 kg/m2 were invited to participate. All patients had a primary THA performed by the direct anterior approach with spinal anesthesia at a hospital facility. Study data were evaluated using an intention-to-treat analysis. A total of 220 patients participated, of whom 112 were randomized to the outpatient group and 108 were randomized to the inpatient group. Of the 112 patients randomized to outpatient surgery, 85 (76%) were discharged as planned. Of the remaining 27 patients, 26 were discharged after one night in the hospital and one was discharged after two nights. Of the 108 patients randomized to inpatient surgery with an overnight hospital stay, 81 (75%) were discharged as planned. Of the remaining 27 patients, 18 met the discharge criteria on the day of their surgery and elected to leave the same day, whereas nine patients stayed two or more nights. RESULTS: On the day of surgery, there was no difference in visual analog scale (VAS) pain among patients who were randomized to discharge on the same day and those who were randomized to remain in the hospital overnight (outpatient 2.8 ± 2.5, inpatient 3.3 ± 2.3, mean difference -0.5, 95% confidence interval [CI], -1.1 to 0.1, p = 0.12). On the first day after surgery, outpatients had higher VAS pain (at home) than inpatients (3.7 ± 2.3 versus 2.8 ± 2.1, mean difference 0.9, 95% CI, 0.3-1.5, p = 0.005). With the numbers available, there was no difference in the number of reoperations, hospital readmissions without reoperation, emergency department visits without hospital readmission, or acute office visits. At 4-week followup, there was no difference in the number of phone calls and emails with the surgeon's office (outpatient: 2.4 ± 1.9, inpatient: 2.4 ± 2.2, mean difference 0, 95% CI, -0.5 to 0.6, p = 0.94). CONCLUSIONS: Outpatient THA can be implemented in a defined patient population without requiring additional work for the surgeon's office. Because 24% (27 of 112) of patients planning to have outpatient surgery were not able to be discharged the same day, facilities to accommodate an overnight stay should be available. LEVEL OF EVIDENCE: Level I, therapeutic study.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Artroplastia de Quadril , Distinções e Prêmios , Articulação do Quadril/cirurgia , Pacientes Internados , Admissão do Paciente , Adulto , Idoso , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Serviço Hospitalar de Emergência , Feminino , Articulação do Quadril/fisiopatologia , Hospitais com Alto Volume de Atendimentos , Humanos , Análise de Intenção de Tratamento , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Visita a Consultório Médico , Medição da Dor , Dor Pós-Operatória/etiologia , Alta do Paciente , Readmissão do Paciente , Philadelphia , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Virginia , Carga de Trabalho
15.
J Arthroplasty ; 29(5): 989-92, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24262142

RESUMO

Minimally invasive unicondylar arthroplasty (UKA) continues to gain popularity for the management of patients with degenerative arthritis limited to one compartment of the knee. In this study, we examine a series of 517 fixed-bearing, cemented unicompartmental knee components implanted in patients to manage degenerative arthritis in the medial compartment of their knee. All UKAs were performed at a single institution using the same fixed-bearing design. In this study we sought to examine the survivorship of the UKA components and the mechanisms of failure for the knees that were revised. The survivorship and revision rate with this implant were similar to those found in other published reports of fixed-bearing unicompartmental arthroplasties performed through minimally invasive surgical techniques.


Assuntos
Artroplastia do Joelho/métodos , Artropatias/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Desenho de Prótese , Reoperação , Estudos Retrospectivos
16.
Bone Joint J ; 106-B(3 Supple A): 44-50, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423104

RESUMO

Aims: The first aim of this study was to evaluate whether preoperative renal function is associated with postoperative changes in whole blood levels of metal ions in patients who have undergone a Birmingham Hip Resurfacing (BHR) arthroplasty with a metal-on-metal bearing. The second aim was to evaluate whether exposure to increased cobalt (Co) and chromium (Cr) levels for ten years adversely affected renal function. Methods: As part of a multicentre, prospective post-approval study, whole blood samples were sent to a single specialized laboratory to determine Co and Cr levels, and the estimated glomerular filtration rate (eGFR). The study included patients with 117 unrevised unilateral BHRs. There were 36 females (31%). The mean age of the patients at the time of surgery of 51.3 years (SD 6.5), and they all had preoperative one-, four-, five-, and ten-year laboratory data. The mean follow-up was 10.1 years (SD 0.2). Results: Median Co levels at one year postoperatively increased significantly compared with the preoperative values, by a factor of 9.7, from 0.13 to 1.26 ppb (p < 0.001), and the median Cr levels increased significantly by a factor of 2.5, from 0.60 to 1.50 ppb (p < 0.001). Lower preoperative eGFRs were associated with significantly larger increases in Co at one year compared with the preoperative levels (ρ = -0.26; p = 0.005), but there was no relationship between preoperative eGFRs and changes in Cr at one year (ρ = -0.13; p = 0.153). Metal levels remained relatively constant with the passage of time, with a median ten-year value of 1.12 ppb for Co and 1.29 ppb for Cr. There was no significant relationship between the Co and Cr levels at ten-year follow-up and the change in eGFR from the preoperative level to that at ten years (ρ = -0.02; p = 0.827 for Co; ρ = -0.008; p = 0.933 for Cr). Conclusion: Although patients with lower preoperative eGFRs tended to have larger increases in Co levels at one year, increased metal levels for patients who underwent unilateral BHR did not adversely affect renal function during the first ten postoperative years.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Feminino , Humanos , Pessoa de Meia-Idade , Prótese de Quadril/efeitos adversos , Taxa de Filtração Glomerular , Estudos Prospectivos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Metais , Cobalto , Cromo
17.
Clin Orthop Relat Res ; 471(1): 86-93, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22879092

RESUMO

BACKGROUND: Wear of total knee polyethylene has been quantified gravimetrically with thickness measurements and evaluation of surface wear modes. However, these techniques do not localize volumetric wear. QUESTIONS/PURPOSES: We used micro-CT scans of retrieved total knee liners and unworn, new liners to determine the volume and location of wear. METHODS: We retrieved 12 fixed and 12 rotating-platform bearings after a mean 52 months of use. Inserts were weighed and thickness was measured. Micro-CT scans of retrieved and matched new liners were superimposed to compare the location and magnitude of wear. RESULTS: The average total wear was 254 ± 248 mm(3). The average wear rate was 58 ± 41 mm(3)/year. Wear was 69% of penetration, demonstrating the contribution of deformation to knee wear. Rotating-platform wear rate was 43 ± 25 mm(3)/year and the fixed-bearing rate was 74 ± 49 mm(3)/year. Five percent of the rotating-platform wear rate came from the backside compared with 14% of the fixed-bearing wear rate. CONCLUSIONS: Micro-CT can determine the volume and location of wear of retrieved tibial liners. Because the magnitude of the manufacturing tolerances was approximately half the magnitude of the total wear on average, accounting for the potential influence of tolerances is important to accurately measure volumetric wear if the unworn (preimplantation) geometry of the insert is unknown. Without accounting for tolerances, this technique may not be applicable for retrievals with a short followup that have low wear. However, application of micro-CT could be of value in determining the exact location of wear in knee simulator studies in which the same insert is measured repeatedly and manufacturing tolerances are not a concern.


Assuntos
Análise de Falha de Equipamento/métodos , Prótese do Joelho , Polietileno , Falha de Prótese , Microtomografia por Raio-X , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estresse Mecânico , Propriedades de Superfície
18.
J Arthroplasty ; 28(8): 1338-44, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23849509

RESUMO

Knee wear is commonly measured with the most recent radiograph based on the assumption that wear progresses at a constant rate. Changing patient activity or in vivo polyethylene deterioration are examples of factors that could cause wear rates to change over time. Using six or more radiographs on each of 251 knees over a mean 10-year follow-up, we determined the pattern of polyethylene wear. 92% of knees had linear wear with a mean wear rate of 0.09 ± 0.12 mm/yr. Ten knees (4%) had late accelerated wear. Knees with accelerated wear and those with a wear rate of 0.15 mm/yr or greater had lower survivorship rates. We conclude that wear is linear with rare exceptions and that higher wear is correlated with failure.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Prótese do Joelho , Falha de Prótese , Radiografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Interpretação Estatística de Dados , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Polietileno , Valor Preditivo dos Testes , Prevalência , Estudos Retrospectivos
19.
Clin Orthop Relat Res ; 470(2): 462-70, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21904891

RESUMO

BACKGROUND: During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners. QUESTIONS/PURPOSES: At minimum 10-year followup, we asked whether the fixation achieved by solely relying on a press-fit would be durable and how different liner sterilization methods affected radiographic wear, osteolysis, and survivorship. PATIENTS AND METHODS: We retrospectively reviewed 373 patients who underwent 398 primary THAs with a press-fit porous-coated cup between March 1995 and December 1996. Mean age at time of surgery was 61.5 ± 13.3 years and mean followup was 10.4 ± 3.7 years. We determined reasons for revision, survivorship, femoral head penetration, osteolysis, and wear-related complications. RESULTS: Among 20 revisions involving any component, seven were associated with wear and osteolysis. Kaplan-Meier survivorship, using component revision for any reason as an end point, was 95.7% (95% confidence interval, 93.6%-97.9%) at 10 years. Noncrosslinked liners sterilized with gas plasma demonstrated a mean head penetration rate of 0.20 ± 0.09 mm/year compared with 0.13 ± 0.07 mm/year for liners sterilized with gamma irradiation in air and 0.09 ± 0.04 mm/year for liners sterilized with gamma-irradiation with barrier packaging without oxygen. THAs with increased volumetric wear tended to demonstrate larger osteolytic lesions (r = 0.40) and there tended to be less osteolysis among the liners sterilized with gamma-irradiation with barrier packaging without oxygen. However, there was no difference in survivorship among the sterilization groups and there has been no cup or stem loosening associated with osteolysis. CONCLUSIONS: Durable biologic fixation through 10-year followup can be achieved by solely relying on an initial press-fit. Noncrosslinking gas plasma for terminal sterilization of the polyethylene liners was associated with greater head penetration rate than gamma irradiation. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteólise/prevenção & controle , Polietileno , Falha de Prótese , Esterilização , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Distribuição de Qui-Quadrado , Feminino , Raios gama/efeitos adversos , Articulação do Quadril/diagnóstico por imagem , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/etiologia , Gases em Plasma/efeitos adversos , Polietileno/efeitos da radiação , Desenho de Prótese , Radiografia , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Esterilização/métodos , Estresse Mecânico , Fatores de Tempo , Resultado do Tratamento , Virginia , Adulto Jovem
20.
J Arthroplasty ; 27(8 Suppl): 2-7.e1, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22682044

RESUMO

In 1999, our institution initiated a prospective study to compare the outcome of total hip arthroplasty patients randomized to either non-cross-linked liners or polyethylene liners that were cross-linked with 5.0 Mrad of gamma-irradiation and heat treated to eliminate free radicals. Among 230 randomized THAs, 13 have had reoperations, and 31 patients with 32 THAs died with less than 9-year follow-up. Follow-up for the remaining 185 THAs averaged 10.0 ± 1.8 years. There have been 9 wear-related liner exchanges among the non-cross-linked group and none among the cross-linked group. Using revision for wear-related complications as an endpoint, survivorship at 10-years was 94.7 ± 4.6% for non-cross-linked and 100% for cross-linked (P = .003). Among unrevised hips, the mean linear wear rate was 0.22 mm/yr for non-cross-linked and 0.04 mm/yr for cross-linked (P < .001). The incidence of clinically important osteolysis with an area of at least 1.5 square centimeters among unrevised hips was 22% for non-cross-linked and 0% for cross-linked (P < .001).


Assuntos
Prótese de Quadril , Polietileno , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA