Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anesthesiology ; 121(4): 765-72, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24937075

RESUMO

BACKGROUND: The initial treatment of an acute blood loss with acellular fluids leads to the dilution of the red cell mass remaining in the vasculature, that is, to acute normovolemic anemia. Whether the compensation and, thus, the tolerance of acute anemia, are affected by sympathetic block induced by thoracic epidural anesthesia has not yet been investigated. METHODS: Eighteen anesthetized and mechanically ventilated pigs were instrumented with thoracic epidural catheters and randomly assigned to receive an epidural injection of either 5-ml ropivacaine 0.2% (n = 9) aiming for a Th5-Th10 block or saline (n = 9) followed by continuous epidural infusion of 5 ml/h of either fluid. Subsequently, acute normovolemic anemia was induced by replacement of whole blood with 6% hydroxyethyl starch solution until a "critical" limitation of oxygen transport capacity was reached as indicated by a sudden decrease in oxygen consumption. The critical hemoglobin concentration quantified at this time point was the primary endpoint; secondary endpoints were hemodynamic and oxygen transport parameters. RESULTS: Thoracic epidural anesthesia elicited only a moderate decrease in mean arterial pressure and cardiac index and a transient decrease in oxygen extraction ratio. During progressive anemia, the compensatory increases in cardiac index and oxygen extraction ratio were not compromised by thoracic epidural anesthesia. Critical hemoglobin concentration was reached at identical levels in both groups (ropivacaine group: 2.5 ± 0.6 g/dl, saline group: 2.5 ± 0.6 g/dl). CONCLUSION: Thoracic epidural anesthesia with ropivacaine 0.2% does not decrease the tolerance to acute normovolemic anemia in healthy pigs. The hemodynamic compensation of acute anemia is fully preserved despite sympathetic block, and the critical hemoglobin concentration remains unaffected.


Assuntos
Amidas/administração & dosagem , Anemia/fisiopatologia , Anestesia Epidural/métodos , Anestésicos Locais/administração & dosagem , Tolerância a Medicamentos , Anemia/diagnóstico , Animais , Volume Sanguíneo/efeitos dos fármacos , Volume Sanguíneo/fisiologia , Tolerância a Medicamentos/fisiologia , Feminino , Masculino , Distribuição Aleatória , Ropivacaina , Suínos , Vértebras Torácicas
2.
Crit Care ; 16(2): R69, 2012 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-22546374

RESUMO

INTRODUCTION: The correction of hypovolemia with acellular fluids results in acute normovolemic anemia. Whether the choice of the infusion fluid has an impact on the maintenance of oxygen (O2) supply during acute normovolemic anemia has not been investigated so far. METHODS: Thirty-six anesthetized and mechanically ventilated pigs were hemodiluted to their physiological limit of anemia tolerance, reflected by the individual critical hemoglobin concentration (Hbcrit). Hbcrit was defined as the Hb-concentration corresponding with the onset of supply-dependency of total body O2-consumption (VO2). The hemodilution protocol was randomly performed with either tetrastarch (6% HES 130/0.4, TS-group, n = 9), gelatin (3.5% urea-crosslinked polygeline, GEL-group, n = 9), hetastarch (6% HES 450/0.7, HS-group, n = 9) or Ringer's solution (RS-group, n = 9). The primary endpoint was the dimension of Hbcrit, secondary endpoints were parameters of central hemodynamics, O2 transport and tissue oxygenation. RESULTS: In each animal, normovolemia was maintained throughout the protocol. Hbcrit was met at 3.7 ± 0.6 g/dl (RS), 3.0 ± 0.6 g/dl (HS P < 0.05 vs. RS), 2.7 ± 0.6 g/dl (GEL, P < 0.05 vs. RS) and 2.1 ± 0.4 g/dl (TS, P < 0.05 vs. GEL, HS and RS). Hemodilution with RS resulted in a significant increase of extravascular lung water index (EVLWI) and a decrease of arterial oxygen partial pressure (paO2), and O2 extraction ratio was increased, when animals of the TS-, GEL- and HS-groups met their individual Hbcrit. CONCLUSIONS: The choice of the intravenous fluid has an impact on the tolerance of acute normovolemic anemia induced by acellular volume replacement. Third-generation tetrastarch preparations (e.g., HES 130/0.4) appear most advantageous regarding maintenance of tissue oxygenation during progressive anemia. The underlying mechanism includes a lower degree of extravasation and favourable effects on microcirculatory function.


Assuntos
Anemia/etiologia , Anemia/fisiopatologia , Hidratação/métodos , Hemodiluição/métodos , Hipovolemia/terapia , Análise de Variância , Animais , Volume Sanguíneo , Eletrocardiografia , Determinação de Ponto Final , Gelatina/farmacologia , Hemodinâmica/fisiologia , Hemoglobinas/análise , Derivados de Hidroxietil Amido/farmacologia , Soluções Isotônicas/farmacologia , Consumo de Oxigênio/fisiologia , Poligelina/farmacologia , Distribuição Aleatória , Análise de Regressão , Respiração Artificial , Solução de Ringer , Suínos
3.
Intensive Care Med ; 34(8): 1534-43, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18385978

RESUMO

OBJECTIVE: To investigate the efficacy of a polyethylene glycol (PEG) modified formulation of liposome-encapsulated hemoglobin (LEH) as an oxygen-carrying blood substitute in the treatment of critical normovolemic anemia. DESIGN AND SETTING: Prospective, controlled, randomized experimental study in a university research facility. SUBJECTS: 14 anesthetized and mechanically ventilated beagle dogs. INTERVENTIONS: Animals were splenectomized and hemodiluted by exchange of whole blood for iso-oncotic hetastarch (HES). Target parameter of the hemodilution protocol was the individual critical hemoglobin concentration (Hb(crit)) corresponding with the onset of O(2) supply dependency of total body O(2) consumption. At Hb(crit) animals were randomized to receive a bolus infusion (20[Symbol: see text]ml/kg) of either LEH (n = 7) or normal saline (NS; n = 7). Subsequently animals were observed without further intervention. MEASUREMENTS AND RESULTS: The primary endpoint was survival time after the completion of treatment; secondary endpoints were parameters of central hemodynamics, O(2) transport and tissue oxygenation. Animals in the LEH group survived significantly longer after completion of treatment (149 +/- 109 vs. 43+/- 56 min). Immediately after treatment LEH-treated animals presented with a more stable cardiovascular condition. After 30 min tissue O(2) tension on the surface of a skeletal muscle was significantly higher in the LEH group (23+/-8 vs. 9 +/- 2 mmHg). Nevertheless, treatment with LEH did not decrease mortality within the observation period. CONCLUSIONS: In this present experimental study the infusion of a PEG-modified LEH provided adequate tissue oxygenation, hemodynamic stability, and a prolongation of survival time after critical anemia. However, these effects were sustained for only a short period of time.


Assuntos
Anemia/terapia , Portadores de Fármacos , Hemodinâmica , Hemoglobinas/administração & dosagem , Consumo de Oxigênio , Polietilenoglicóis , Animais , Química Farmacêutica , Cães , Feminino , Lipossomos , Masculino
4.
Rev Sci Instrum ; 81(5): 053702, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20515140

RESUMO

We present a novel quartz cantilever for frequency-modulation atomic force microscopy (FM-AFM) which has three electrodes: an actuating electrode, a sensing electrode, and a ground electrode. By applying an ac signal on the actuating electrode, the cantilever is set to vibrate. If the frequency of actuation voltage closely matches one of the characteristic frequencies of the cantilever, a sharp resonance should be observed. The vibration of the cantilever in turn generates a current on the sensing electrode. The arrangement of the electrodes is such that the cross-talk capacitance between the actuating electrode and the sensing electrode is less than 10(-16) F, thus the direct coupling is negligible. To verify the principle, a number of samples were made. Direct measurements with a Nanosurf easyPPL controller and detector showed that for each cantilever, one or more vibrational modes can be excited and detected. Using classical theory of elasticity, it is shown that such novel cantilevers with proper dimensions can provide optimized performance and sensitivity in FM-AFM with very simple electronics.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA