RESUMO
The present work describes a curriculum design with the instrument of an examination mix for the study of medicine at the medical University of Vienna. The fields of application of special examination formats as well as the advantages and disadvantages of the individual examination forms are presented. Types of summative written examinations, assessment of practical skills and abilities (OSCE), oral-practical examinations, as well as formative examinations are illustrated. Studies show that repeated testing leads to higher learning gains. Therefore, the challenge is to develop suitable methods for the continuous assessment of the learning progress in the study and to apply accordingly. Thus, in addition to the written summative exams, more and more oral and practical forms of examinations in courses with continuous assessment character should be used.
Assuntos
Currículo , Educação de Graduação em Medicina , Avaliação Educacional , Áustria , Competência Clínica , Humanos , UniversidadesRESUMO
OBJECTIVE: To compare, in a retrospective observational cohort study, the efficacy, tolerability and safety of propiverine and oxybutynin in children with urge incontinence (UI) due to overactive bladder. PATIENTS AND METHODS: Medical records were scrutinized for children with UI. As a primary efficacy outcome variable the achievement of continence after treatment with variable doses of propiverine or oxybutynin was assessed. Weekly UI episodes and daily voiding frequency were evaluated as secondary efficacy outcomes. Tolerability was evaluated by the rate of adverse events, adverse drug reactions caused by antimuscarinics and premature treatment termination. RESULTS: At 16 study centres, 621 children aged 5-14 years with UI due to overactive bladder were enrolled. After anticholinergic treatment (437 propiverine, 184 oxybutynin) continence was achieved in 61.6% and 58.7% of the patients after 186 and 259 days, respectively. There were clinically relevant improvements in voiding frequency across treatment groups. Daily doses of propiverine were markedly below the recommendations (0.54 vs 0.8 mg/kg body weight), daily doses of oxybutynin were according to the recommendations (0.31 vs 0.2-0.4 mg/kg body weight) at treatment initiation. There was a significantly more favourable tolerability to propiverine than oxybutynin for the overall rate of adverse events (3.9% vs 16.3%, odds ratio 4.813), adverse drug reactions caused by propiverine or oxybutynin (2.8% vs 9.2%) and premature treatment termination due to adverse drug reactions (1.6% vs 4.4%). CONCLUSION: Propiverine and oxybutynin are effective in children with UI due to overactive bladder. Sufficient treatment periods of at least 2, preferably 3-4, months are the crucial factors for a successful treatment. The tolerability profile of propiverine is better than for oxybutynin.
Assuntos
Benzilatos/uso terapêutico , Antagonistas Colinérgicos/uso terapêutico , Ácidos Mandélicos/uso terapêutico , Bexiga Urinária Hiperativa/tratamento farmacológico , Incontinência Urinária de Urgência/tratamento farmacológico , Adolescente , Benzilatos/efeitos adversos , Criança , Pré-Escolar , Antagonistas Colinérgicos/efeitos adversos , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Ácidos Mandélicos/efeitos adversos , Resultado do Tratamento , Bexiga Urinária Hiperativa/complicações , Incontinência Urinária de Urgência/etiologiaRESUMO
Calculating the daily changing composition of parenteral nutrition for small newborn infants is troublesome and time consuming routine work in neonatal intensive care. The task needs expertise and experience and is prone to inherent calculation errors. We designed VIE-PNN (Vienna Expert System for Parenteral Nutrition of Neonates), a knowledge-based system (KBS) in order to reduce daily routine work and calculation errors. VIE-PNN was redesigned several times because the clinicians accepted the system only when it saved time. The most recent version of VIE-PNN uses an Hypertext Markup Language (HTML)-based client-server architecture and is integrated into the intranet of the local patient data management system. Since more than 3 years all parenteral nutrition plans are calculated using VIE-PNN. Evaluating the system's performance and the users contentedness, we compared 50 nutrition plans calculated in parallel using VIE-PNN or a hand-held calculator, retrospectively analyzed more than 5000 nutrition plans stored in VIE-PNNs database and evaluated a user questionnaire. Nutrition plans were calculated in a mean time of 2.4 versus 7.1min using VIE-PNN or the hand-held calculator. Errors and omissions in the nutrition plans were detected in 22% versus 56% and errors in the VIE-PNN's plans occurring only with interactively changed values. Reviews of stored plans show that a mean of 4 out of 16 parameters were interactively changed. VIE-PNN was well accepted. Most important reasons for the successful operation of VIE-PNN in the daily routine work were time savings and robustness of the system.
Assuntos
Inteligência Artificial , Cuidado do Lactente , Sistemas Computadorizados de Registros Médicos , Nutrição Parenteral , Redes de Comunicação de Computadores , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Erros de Medicação/prevenção & controle , Estado Nutricional , Planejamento de Assistência ao Paciente , Estudos RetrospectivosRESUMO
BACKGROUND AND OBJECTIVE: In preterm infants receiving supplemental oxygen, routine manual control (RMC) of the fraction of inspired oxygen (FIO2) is often difficult and time consuming. We developed a system for closed-loop automatic control (CLAC) of the FIO2 and demonstrated its short-term safety and efficacy in a single-center study. The objective of this study was to test the hypothesis that this system is more effective than RMC alone in maintaining arterial oxygen saturation within target levels when evaluated over 24 hours under routine conditions and with different target levels. METHODS: We performed a multicenter, randomized controlled, crossover clinical trial in 34 preterm infants receiving mechanical ventilation or nasal continuous positive airway pressure and supplemental oxygen. Twenty-four-hour periods with RMC were compared with 24-hour periods of RMC supported by CLAC. RESULTS: The median (range) percentage of time with arterial oxygen saturation levels within target range was 61.4 (31.5-99.5) for RMC and 71.2 (44.0-95.4) for CLAC (P < .001). The median (range) number of manual FIO2 adjustments was reduced from 77.0 (0.0-224.0) for RMC to 52.0 (10.0-317.0) for CLAC (P = .007). CONCLUSIONS: CLAC may improve oxygen administration to preterm infants receiving mechanical ventilation or nasal continuous positive airway pressure while reducing workload related to RMC.
Assuntos
Oxigênio/administração & dosagem , Respiração Artificial/métodos , Pressão Positiva Contínua nas Vias Aéreas/métodos , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Método Simples-CegoAssuntos
Educação em Enfermagem/legislação & jurisprudência , Diretrizes para o Planejamento em Saúde , Programas Nacionais de Saúde/legislação & jurisprudência , Enfermagem Pediátrica/educação , Criança , Competência Clínica/legislação & jurisprudência , Currículo , Alemanha , Implementação de Plano de Saúde/legislação & jurisprudência , Hospitais de Ensino , Humanos , Enfermagem Pediátrica/legislação & jurisprudência , Escolas de Enfermagem/legislação & jurisprudênciaRESUMO
INTRODUCTION: In this paper, we evaluated the feasibility of a telemedical (TM) support program and its effect on glycemic control in adolescents with type 1 diabetes mellitus (T1DM). Thirty-six adolescents (m=20, median age at the start of the study: 15.3 years (range: 10.7-19.3 years), median age at diagnosis: 9.3 years (2.1-13.8 years), median duration of disease: 6.4 years (1.0-12.8 years), HbA1c>8%, all on intensified insulin therapy) were randomized in a crossover trial over 6 months (3 months with TM, 3 months with conventional support and paper diary (PD)). During the TM phase, the patients sent their data (date, time, blood glucose, carbohydrate intake, insulin dosage) via mobile phone, at least daily, to our server and diabetologists sent back their advice via short message service (SMS) once a week. RESULTS: Glycemic control improved during the TM phase, while it deteriorated during the PD phase: TM-PD group HbA1c (%, median (range)): 9.05 (8-11.3) (at 0 months), 8.9 (6.9-11.3) (at 3 months), and 9.2 (7.4-12.6) (at 6 months), and PD-TM group: 8.9 (8.3-11.6), 9.9 (8.1-11), and 8.85 (7.3-11.7) (p<0.05). Patients rated the TM support program to be a good idea. Technical problems with General Packet Radio Service (GPRS) data transmission led to data loss and decreased patient satisfaction. CONCLUSION: Our telemedical support program, VIE-DIAB, proved to be feasible in adolescents and helped to improve glycemic control.
Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/terapia , Telemedicina , Adolescente , Estudos Cross-Over , Feminino , Humanos , Modelos Lineares , Masculino , Satisfação do Paciente , Projetos PilotoRESUMO
In preterm infants receiving supplemental oxygen, manual control of the inspired oxygen fraction is often time-consuming and inappropriate. We developed a system for automatic oxygen control and hypothesized that this system is more effective than routine manual oxygen control in maintaining target arterial oxygen saturation levels. We performed a randomized controlled crossover clinical trial in 12 preterm infants receiving nasal continuous positive airway pressure and supplemental oxygen. Periods with automatic and routine manual oxygen control were compared with periods of optimal control by a fully dedicated person. The median (range) percentage of time with arterial oxygen saturation levels within target range (87-96%) was 81.7% (39.0-99.8) for routine manual oxygen control, 91.0% (41.4-99.3) for optimal control, and 90.5% (59.0-99.4) for automatic control (ANOVA: p = 0.01). Pairwise post hoc comparisons revealed a statistically significant difference between automatic and routine manual oxygen control (Dunnett's test: p = 0.02). The frequency of manual oxygen adjustments was lowest in automatic control (Friedman's test: p < 0.001). Automatic oxygen control may optimize oxygen administration to preterm infants receiving nasal continuous positive airway pressure and reduce nursing time spent with oxygen control.