1.
Blood ; 120(2): 440-8, 2012 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-22529288

RESUMO

The quantification of residual plasmatic ADAMTS13 activity in congenital thrombotic thrombocytopenic purpura (TTP) patients is constrained by limitations in sensitivity and reproducibility of commonly used assays at low levels of ADAMTS13 activity, blunting efforts to establish genotype-phenotype correlations. In the present study, the residual plasmatic activity of ADAMTS13 was measured centrally by surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (limit of detection = 0.5%) in 29 congenital TTP patients. The results were used to study correlations among ADAMTS13 genotype, residual plasmatic activity, and clinical phenotype severity. An ADAMTS13 activity above 0.5% was measured in 26 (90%) patients and lower levels of activity were associated with earlier age at first TTP episode requiring plasma infusion, more frequent recurrences, and prescription of fresh-frozen plasma prophylaxis. Receiver operating characteristic curve analysis showed that activity levels of less than 2.74% and 1.61% were discriminative of age at first TTP episode requiring plasma infusion < 18 years, annual rate of TTP episodes > 1, and use of prophylaxis. Mutations affecting the highly conserved N-terminal domains of the protein were associated with lower residual ADAMTS13 activity and a more severe phenotype in an allelic-dose dependent manner. The results of the present study show that residual ADAMTS13 activity is associated with the severity of clinical phenotype in congenital TTP and provide insights into genotype-phenotype correlations.


Assuntos
Proteínas ADAM/sangue , Proteínas ADAM/deficiência , Púrpura Trombocitopênica Trombótica/sangue , Púrpura Trombocitopênica Trombótica/congênito , Proteínas ADAM/genética , Proteína ADAMTS13 , Adolescente , Adulto , Fatores Etários , Idoso , Análise Química do Sangue , Transfusão de Sangue , Criança , Pré-Escolar , Análise Mutacional de DNA , Feminino , Estudos de Associação Genética , Humanos , Masculino , Pessoa de Meia-Idade , Mutação , Plasma , Púrpura Trombocitopênica Trombótica/genética , Púrpura Trombocitopênica Trombótica/terapia , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Adulto Jovem
2.
Neuromodulation ; 12(2): 85-103, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20657744

RESUMO

Deep Brain Stimulation (DBS) provides therapeutic benefit for several neuropathologies including Parkinson's disease (PD), epilepsy, chronic pain, and depression. Despite well established clinical efficacy, the mechanism(s) of DBS remains poorly understood. In this review we begin by summarizing the current understanding of the DBS mechanism. Using this knowledge as a framework, we then explore a specific hypothesis regarding DBS of the subthalamic nucleus (STN) for the treatment of PD. This hypothesis states that therapeutic benefit is provided, at least in part, by activation of surviving nigrostriatal dopaminergic neurons, subsequent striatal dopamine release, and resumption of striatal target cell control by dopamine. While highly controversial, we present preliminary data that are consistent with specific predications testing this hypothesis. We additionally propose that developing new technologies, e.g., human electrometer and closed-loop smart devices, for monitoring dopaminergic neurotransmission during STN DBS will further advance this treatment approach.

3.
Am J Med Qual ; 23(5): 382-8, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18820143

RESUMO

As organizations strive for ways to control health care spending, address the growing needs of an aging population, and respond satisfactorily to a more informed and demanding consumer base, the opportunities for innovation have increased exponentially. By means of this article, the authors describe the basic concepts of purposeful innovation, and compare and contrast it to quality improvement. The authors also provide an overview of the terminology and types of innovation, describe the innovation life cycle, and discuss diffusion and commercialization of innovations. This article provides a primer on innovation for quality improvement practitioners and physician leaders who play a key role in creating innovation and environments for innovations to flourish.


Assuntos
Atenção à Saúde/organização & administração , Difusão de Inovações , Inovação Organizacional , Garantia da Qualidade dos Cuidados de Saúde/organização & administração , Custos e Análise de Custo , Medicina Baseada em Evidências , Humanos , Pesquisa/organização & administração
4.
Scientifica (Cairo) ; 2014: 613689, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24729918

RESUMO

Background. HIV-infected subjects have an increased incidence of pulmonary emphysema. There are known gender differences in COPD phenotypic expression and diagnosis, but this is not well characterized in lung disease related to HIV. We analyzed a group at risk for the development of COPD (HIV-infected smokers) to determine gender differences in pulmonary symptoms, pulmonary function tests, and HRCT appearances. Methods. This was a cross-sectional, baseline analysis of a prospective study performed between 2006 and 2010. We performed symptomatic, pulmonary function, and computed tomography assessments in 243 HIV-infected smokers. In a subset bronchoalveolar lavage was performed with proteomic analysis of their alveolar macrophages. Results. The majority of the participants were male 213 (87.6%). There was significantly higher percentage of cough and phlegm production in males. There was also a lower FEV1 and a higher RV in males than females. Proteomic analysis revealed 29 proteins with at least a 2-fold higher expression in males and 13 identified proteins that were higher in females. Conclusions. In this group of HIV-infected smokers, airway symptoms and pulmonary function test abnormalities were higher in men than women. These gender differences may be due to differential expression of certain proteins in this group.

5.
J Neurosurg ; 119(6): 1556-65, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24116724

RESUMO

OBJECT: Conventional deep brain stimulation (DBS) devices continue to rely on an open-loop system in which stimulation is independent of functional neural feedback. The authors previously proposed that as the foundation of a DBS "smart" device, a closed-loop system based on neurochemical feedback, may have the potential to improve therapeutic outcomes. Alterations in neurochemical release are thought to be linked to the clinical benefit of DBS, and fast-scan cyclic voltammetry (FSCV) has been shown to be effective for recording these evoked neurochemical changes. However, the combination of FSCV with conventional DBS devices interferes with the recording and identification of the evoked analytes. To integrate neurochemical recording with neurostimulation, the authors developed the Mayo Investigational Neuromodulation Control System (MINCS), a novel, wirelessly controlled stimulation device designed to interface with FSCV performed by their previously described Wireless Instantaneous Neurochemical Concentration Sensing System (WINCS). METHODS: To test the functionality of these integrated devices, various frequencies of electrical stimulation were applied by MINCS to the medial forebrain bundle of the anesthetized rat, and striatal dopamine release was recorded by WINCS. The parameters for FSCV in the present study consisted of a pyramidal voltage waveform applied to the carbon-fiber microelectrode every 100 msec, ramping between -0.4 V and +1.5 V with respect to an Ag/AgCl reference electrode at a scan rate of either 400 V/sec or 1000 V/sec. The carbon-fiber microelectrode was held at the baseline potential of -0.4 V between scans. RESULTS: By using MINCS in conjunction with WINCS coordinated through an optic fiber, the authors interleaved intervals of electrical stimulation with FSCV scans and thus obtained artifact-free wireless FSCV recordings. Electrical stimulation of the medial forebrain bundle in the anesthetized rat by MINCS elicited striatal dopamine release that was time-locked to stimulation and increased progressively with stimulation frequency. CONCLUSIONS: Here, the authors report a series of proof-of-principle tests in the rat brain demonstrating MINCS to be a reliable and flexible stimulation device that, when used in conjunction with WINCS, performs wirelessly controlled stimulation concurrent with artifact-free neurochemical recording. These findings suggest that the integration of neurochemical recording with neurostimulation may be a useful first step toward the development of a closed-loop DBS system for human application.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Equipamentos e Provisões/normas , Retroalimentação Fisiológica/fisiologia , Neurotransmissores/fisiologia , Animais , Técnicas Biossensoriais/normas , Corpo Estriado/metabolismo , Estimulação Encefálica Profunda/métodos , Estimulação Encefálica Profunda/normas , Dopamina/metabolismo , Técnicas Eletroquímicas/normas , Desenho de Equipamento/normas , Masculino , Feixe Prosencefálico Mediano/fisiologia , Microeletrodos/estatística & dados numéricos , Ratos , Ratos Sprague-Dawley
6.
J Neurosurg ; 111(4): 712-23, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19425890

RESUMO

OBJECT: Emerging evidence supports the hypothesis that modulation of specific central neuronal systems contributes to the clinical efficacy of deep brain stimulation (DBS) and motor cortex stimulation (MCS). Real-time monitoring of the neurochemical output of targeted regions may therefore advance functional neurosurgery by, among other goals, providing a strategy for investigation of mechanisms, identification of new candidate neurotransmitters, and chemically guided placement of the stimulating electrode. The authors report the development of a device called the Wireless Instantaneous Neurotransmitter Concentration System (WINCS) for intraoperative neurochemical monitoring during functional neurosurgery. This device supports fast-scan cyclic voltammetry (FSCV) at a carbon-fiber microelectrode (CFM) for real-time, spatially and chemically resolved neurotransmitter measurements in the brain. METHODS: The FSCV study consisted of a triangle wave scanned between -0.4 and 1 V at a rate of 300 V/second and applied at 10 Hz. All voltages were compared with an Ag/AgCl reference electrode. The CFM was constructed by aspirating a single carbon fiber (r = 2.5 mum) into a glass capillary and pulling the capillary to a microscopic tip by using a pipette puller. The exposed carbon fiber (that is, the sensing region) extended beyond the glass insulation by approximately 100 microm. The neurotransmitter dopamine was selected as the analyte for most trials. Proof-of-principle tests included in vitro flow injection and noise analysis, and in vivo measurements in urethane-anesthetized rats by monitoring dopamine release in the striatum following high-frequency electrical stimulation of the medial forebrain bundle. Direct comparisons were made to a conventional hardwired system. RESULTS: The WINCS, designed in compliance with FDA-recognized consensus standards for medical electrical device safety, consisted of 4 modules: 1) front-end analog circuit for FSCV (that is, current-to-voltage transducer); 2) Bluetooth transceiver; 3) microprocessor; and 4) direct-current battery. A Windows-XP laptop computer running custom software and equipped with a Universal Serial Bus-connected Bluetooth transceiver served as the base station. Computer software directed wireless data acquisition at 100 kilosamples/second and remote control of FSCV operation and adjustable waveform parameters. The WINCS provided reliable, high-fidelity measurements of dopamine and other neurochemicals such as serotonin, norepinephrine, and ascorbic acid by using FSCV at CFM and by flow injection analysis. In rats, the WINCS detected subsecond striatal dopamine release at the implanted sensor during high-frequency stimulation of ascending dopaminergic fibers. Overall, in vitro and in vivo testing demonstrated comparable signals to a conventional hardwired electrochemical system for FSCV. Importantly, the WINCS reduced susceptibility to electromagnetic noise typically found in an operating room setting. CONCLUSIONS: Taken together, these results demonstrate that the WINCS is well suited for intraoperative neurochemical monitoring. It is anticipated that neurotransmitter measurements at an implanted chemical sensor will prove useful for advancing functional neurosurgery.


Assuntos
Encéfalo/metabolismo , Técnicas Eletroquímicas/instrumentação , Monitorização Intraoperatória/instrumentação , Neurotransmissores/metabolismo , Telemetria/instrumentação , Animais , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Estimulação Encefálica Profunda , Dopamina/metabolismo , Estimulação Elétrica , Técnicas Eletroquímicas/métodos , Masculino , Modelos Animais , Monitorização Intraoperatória/métodos , Neurocirurgia/instrumentação , Neurocirurgia/métodos , Norepinefrina/metabolismo , Ratos , Ratos Sprague-Dawley , Serotonina/metabolismo , Telemetria/métodos
7.
Artigo em Inglês | MEDLINE | ID: mdl-19963865

RESUMO

The Wireless Instantaneous Neurotransmitter Concentration Sensing System (WINCS) measures extracellular neurotransmitter concentration in vivo and displays the data graphically in nearly real time. WINCS implements two electroanalytical methods, fast-scan cyclic voltammetry (FSCV) and fixed-potential amperometry (FPA), to measure neurotransmitter concentrations at an electrochemical sensor, typically a carbon-fiber microelectrode. WINCS comprises a battery-powered patient module and a custom software application (WINCSware) running on a nearby personal computer. The patient module impresses upon the electrochemical sensor either a constant potential (for FPA) or a time-varying waveform (for FSCV). A transimpedance amplifier converts the resulting current to a signal that is digitized and transmitted to the base station via a Bluetooth radio link. WINCSware controls the operational parameters for FPA or FSCV, and records the transmitted data stream. Filtered data is displayed in various formats, including a background-subtracted plot of sequential FSCV scans - a representation that enables users to distinguish the signatures of various analytes with considerable specificity. Dopamine, glutamate, adenosine and serotonin were selected as analytes for test trials. Proof-of-principle tests included in vitro flow-injection measurements and in vivo measurements in rat and pig. Further testing demonstrated basic functionality in a 3-Tesla MRI unit. WINCS was designed in compliance with consensus standards for medical electrical device safety, and it is anticipated that its capability for real-time intraoperative monitoring of neurotransmitter release at an implanted sensor will prove useful for advancing functional neurosurgery.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Encéfalo/metabolismo , Dopamina/metabolismo , Humanos , Serotonina/metabolismo , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA