1.
Bioanalysis ; 14(18): 1213-1227, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36408704

RESUMO

Background: Many bioanalytical methods for antisense oligonucleotides (ASOs) using LC-MS have been reported. However, no data have been available on the reproducibility and robustness of a single bioanalytical method for ASOs. As such, in the current study, we evaluated the reproducibility and robustness of LC-MS-based bioanalytical methods for ASOs in multiple laboratories. Methods/Results: Seven independent laboratories were included in this study. Mipomersen was measured by ion-pairing LC-MS (IP-LC-MS) as a model ASO using different LC-MS. The validation results of calibration curve, accuracy, precision and selectivity met the criteria of conventional bioanalytical method validation guidelines using LC/GC-MS for drugs in all laboratories. Meanwhile, carryover (>20%) was detected in three laboratories. Conclusion: We first demonstrated the multicenter-validated IP-LC-MS bioanalytical method for ASOs. Our data showed that the method was sensitive, robust and reproducible. However, the occurrence of carryover should be carefully monitored in its future application.


Assuntos
Terapia Biológica , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes , Calibragem
2.
Bioanalysis ; 12(24): 1739-1756, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33242248

RESUMO

Background: Ion-pairing reverse-phase LC coupled with high-resolution mass spectrometry (IP-LC/HRMS) has gained attention in oligonucleotide therapeutic bioanalyses owing to its high sensitivity and selectivity. However, optimization and validation of IP-LC/HRMS-based methods are rare. The objective of this study is the development of a sensitive and reproducible IP-LC/HRMS-based bioanalytical method using clinically approved mipomersen as a model for antisense oligonucleotides. Materials & methods/results: Mipomersen was extracted from rat plasma using Clarity OTX SPE and quantified by IP-LC/HRMS. The calibration range was 0.5-250.0 ng/ml. The developed method met the general regulatory criteria for accuracy, precision, carry-over, selectivity, matrix effect and dilution integrity. Conclusion: A highly sensitive and reliable method for mipomersen measurement with potential antisense oligonucleotide bioanalysis applications has been developed.


Assuntos
Terapia Biológica/métodos , Cromatografia Líquida/métodos , DNA Antissenso/metabolismo , Espectrometria de Massas/métodos , Oligonucleotídeos/metabolismo , Calibragem , Humanos