Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Pers Med ; 12(7)2022 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-35887548

RESUMO

Background: The maintenance of marginal bone levels around dental implants is an important criterion for evaluating the success of implants. Although computer-aided design/computer-aided manufacturing (CAD/CAM) customized abutments (CAs) provide more flexible solutions, compared with the original preformed stock abutments (PAs), there are dimensional tolerances and underlying drawbacks in the production of CAD/CAM CAs, which may change the tightness and seamless connection between fixtures and abutments set by the manufacturer and then affect the long-term stability of the abutments. This study aimed to examine the change in both mesial and distal bone levels using digital periapical radiographs to evaluate the difference between CAD/CAM CAs and original PAs.Material and methods: Radiographs were taken before delivery; after functional loading for 1 month; and after 3, 6, and 12 months; and the vertical marginal bone levels (vMBLs) of both the mesial and distal surrounding implant bones were measured. All data are presented as means ± standard errors and were analyzed using Student's t-test. A p-value < 0.05 was judged to represent a significant difference. Results: A total of 57 implants in 50 patients were divided into 22 CAD/CAM CAs and 35 original stock abutments. The PAs appeared to have a more stable bone level. By contrast, the amount of bone level change in the CAs was higher than that in the PAs. The change in the vMBL of the CAs was significantly more than that of the PAs after functional loading for 1 month (p = 0.006), 3 months (p = 0.013), 6 months (p = 0.014), and 12 months (p = 0.002). In contrast, the distal marginal bone level was lower than the mesial marginal bone level in any period. Nevertheless, the bone levels of the CAs and PAs in any period were comparable with no significant difference. Conclusions: Significant differences were found between the mesial and distal bone levels in the PAs. The CAD/CAM CAs showed a significantly greater bone level change than the original stock abutments after functional loading.

2.
Artigo em Inglês | MEDLINE | ID: mdl-35162773

RESUMO

Few studies have compared marginal bone loss (MBL) around implant-retaining overdentures (IODs) vs. implant-supported fixed prostheses (FPs). This study evaluated the mean MBL and radiographic bone-implant interface contact (r-BIIC) around IODs and implant-supported FPs. We also investigated osseointegration and MBL around non-submerged dental implants. We measured the changes between the MBL in the mesial and distal sites immediately after prosthetic delivery and after one year. The mean MBL and its changes in the IOD group were significantly higher. The mean percentage of r-BIIC was significantly higher in the FP group. MBL and its changes in males were significantly higher in the IOD group. The percentage of r-BIIC was significantly higher in the FP group. MBL in the lower site in the IOD group was significantly higher. Regarding MBL, the location of the implant was the only significant factor in the IOD group, while gender was the only significant predictor in the FP group. Regarding the r-BIIC percentage, gender was a significant factor in the FP group. We concluded that non-submerged dental implants restored with FPs and IODs maintained stable bone remodeling one year after prosthetic delivery.


Assuntos
Interface Osso-Implante , Revestimento de Dentadura , Remodelação Óssea , Seguimentos , Humanos , Masculino , Osseointegração , Estudos Retrospectivos
3.
J Pers Med ; 12(8)2022 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-36013175

RESUMO

Preserving the marginal bone level (MBL) is essential for the long-term success of dental implant therapy, and bone remodeling around dental implants is considered to vary with time. Numerous studies comparing the platform-switching (PS) and platform-matching (PM) dental implants have indicated that PS dental implants showed a lesser reduction for the MBL, and the majority of them had a relatively short period. This study aimed to evaluate vertical and horizontal bone defects by using digital periapical radiographs to examine the changes in MBL around PM and PS dental implants over 5 years after functional loading. The vertical MBL (vMBL) was measured from the implant-abutment junction to the first bone-to-implant contact. The horizontal MBL (hMBL) was measured from the implant-abutment junction to the bone crest. All data were presented as means ± standard errors. Paired and independent t-tests with Welch's correction were used to analyze the data. A total of 61 dental implants in 38 patients after 5 years of functional loading were evaluated. Over time, PS dental implants were more likely to gain bone; by contrast, PM dental implants were more likely to lose bone during the observation time. Changes in vMBL for PS dental implants were significantly less than those for PM dental implants at 1-year (p = 0.045), 3-year (p = 0.021), and 5-year (p = 0.010) loading. Likewise, changes in hMBL for PS dental implants were significantly smaller than in those for PM dental implants at 3-year (p = 0.021) and 5-year (p = 0.006) loading; however, the changes were minimal in both approaches. PS dental implants had a significant increment in the percentage of bone integration, whereas that for PM dental implants dropped over time, with no significance. In PS dental implants that occlude with natural teeth, vertical and horizontal bone gain was observed, and it was significant at 3 years (p = 0.023). A significant horizontal bone gain was observed in the opposing natural teeth at 3-year (p = 0.002) and 5-year loading (p = 0.002). The PS concept appears to preserve more MBL around dental implants by stabilizing the vMBL and hMBL over a 5-year period. A minimal marginal bone change was detected in both concepts. The opposing natural teeth at PS dental implants showed a favorable effect on marginal bone tissues.

4.
Artigo em Inglês | MEDLINE | ID: mdl-34682460

RESUMO

BACKGROUND: The objective of this study was to evaluate the effects of opposite tooth conditions on change in marginal bone level (MBL) around submerged dental implants. MATERIALS AND METHODS: The study included healthy patients with one or two implants. Structures opposite implants were either natural teeth (NT) or fixed restorations (FRs). MBLs were measured on digital periapical radiographs at the mesial and distal aspects of each implant. RESULTS: Sixty implants were inserted by the 3-year follow-up. Mean MBLs for NT were 0.21 ± 0.33 mm before prosthetic loading and 0.30 ± 0.41 mm 3 years later (p = 0.001). Mean MBLs with FRs were 0.36 ± 0.45 mm before loading and 0.53 ± 0.50 mm 3 years later (p < 0.001). Changes in mean MBL from the 6-month follow-up to the 1- and 3-year follow-ups were statistically significant (p < 0.01) for implants opposite NT. However, changes in mean MBL from the 6-month follow-up to the 1-year (p = 0.161) and 3-year follow-ups (p = 1.000) were not significant for implants opposite FRs. Between baseline and the 3-year follow-up, MBL change was relatively small and did not differ regarding NT and FRs. CONCLUSION: Bone loss was greater if submerged dental implants were opposed by FRs. MBLs around submerged implants continued to change after 3 years if NT opposed implants.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Boca Edêntula , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/epidemiologia , Perda do Osso Alveolar/etiologia , Implantes Dentários/efeitos adversos , Seguimentos , Humanos , Estudos Retrospectivos
5.
Artigo em Inglês | MEDLINE | ID: mdl-34299898

RESUMO

Absorbable porcine collagen membrane with a bovine bone graft can be considered for regenerative treatment in periodontal class II furcation defects. We evaluated the clinical efficacy of guided tissue regeneration (GTR) treatment with bovine bone xenograft and a porcine collagen membrane in molars with class II furcations. Probing depth (PD), clinical attachment level (CAL), and bone level (BL) were recorded at baseline and at 3, 6, and 9 months postoperatively. Thirty class II furcation defects from the lower and upper molars were assessed. Significant improvements in PD and CAL were observed from baseline to 9 months in all groups (p < 0.01). BL improved in all groups except group A in the upper molars in radiographic assessment (p < 0.05). The lower and upper molars showed PD reduction of 50.5% ± 7.44% and 46.2% ± 11.2%, respectively, at 9 months (p = 0.044). In furcations of 1-3 mm, the lower and upper molars showed PD reductions of 51.2% ± 4.49% and 36.5% ± 16.14%, respectively (p = 0.035). The lower and upper molars showed a CAL gain of 51.1% ± 4.64% and 33.6% ± 18.8%, respectively (p = 0.037). Thus, GTR with bovine bone graft and porcine collagen membrane yielded good results in class II furcations, with better results in the lower than in the upper molars.


Assuntos
Regeneração Tecidual Guiada Periodontal , Maxila , Animais , Bovinos , Seguimentos , Mandíbula , Membranas Artificiais , Perda da Inserção Periodontal/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-31323848

RESUMO

OBJECTIVE: To describe remodeling of the mesial and distal marginal bone level around platform-switched (PS) and platform-matched (PM) dental implants that were sandblasted with large grit and etched with acid over a three-year period. MATERIALS AND METHODS: Digital periapical radiographs were obtained at the following time-points: during Stage I of the surgical placement of dental implants, before loading, immediately after loading (baseline), and one, three, six, 12, and 36 months after loading for measuring the horizontal and vertical marginal bone levels. RESULTS: Sixty implants were successfully osseointegrated during the overall observation period. Vertical marginal bone levels for the PS and PM dental implants were 0.78 ± 0.77 and 0.98 ± 0.81 mm, respectively, whereas the horizontal marginal bone levels for the PS and PM implants were 0.84 ± 0.45 and 0.98 ± 0.68 mm, respectively. During the time leading up to the procedure until 36 months after the procedure, the average vertical marginal bone level resulted in less bone loss for the PS and PM groups-0.96 ± 1.28 and 0.30 ± 1.15 mm, respectively (p < 0.05). The mean levels of the horizontal marginal bone also showed increases of 0.48 ± 1.01 mm in the PS and 0.37 ± 0.77 mm in the PM groups from the time before loading until 36 months after the procedure. However, these increases were not statistically significant (p > 0.05). CONCLUSION: PS dental implants appeared to be more effective than PM implants for minimizing the mean marginal vertical and horizontal marginal bone loss during the three-year period. Regardless of which abutment connection was used, the dental implant in the present retrospective investigation exhibited minimal marginal bone remodeling, thus indicating long-term stability.


Assuntos
Perda do Osso Alveolar/etiologia , Prótese Ancorada no Osso/estatística & dados numéricos , Implantação Dentária Endóssea/instrumentação , Implantes Dentários/estatística & dados numéricos , Osseointegração , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/diagnóstico por imagem , Osso e Ossos , Prótese Ancorada no Osso/efeitos adversos , Implantação Dentária Endóssea/estatística & dados numéricos , Implantes Dentários/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Dentária , Estudos Retrospectivos
7.
Biomed Res Int ; 2017: 7191534, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29204445

RESUMO

The benefits and feasibility of platform switching have been discussed in several studies, reporting lesser crestal bone loss in platform-switched implants than in platform-matched implants. Objective. The aim of the present study was to observe the changes in vertical and horizontal marginal bone levels in platform-switched and platform-matched dental implants. Materials and Methods. 51 patients received 60 dental implants in the present study over a 1-year period. Measurement was performed between the implant shoulder and the most apical and horizontal marginal defect by periapical radiographs to examine the changes of peri-implant alveolar bone before and 12 months after prosthodontic restoration delivery. Results. These marginal bone measurements showed a bone gain of 0.23 ± 0.58 mm in the vertical gap and 0.22 ± 0.53 mm in the horizontal gap of platform matching, while in platform switching a bone gain of 0.93 ± 1 mm (P < 0.05) in the vertical gap and 0.50 ± 0.56 mm in the horizontal gap was found. The average vertical gap reduction from the baseline until 12 months was 0.92 ± 1.11 mm in platform switching and 0.29 ± 0.85 mm in platform matching (P < 0.05). Conclusions. Within the limitations of the present study, platform switching seemed to be more effective for a better peri-implant alveolar bone vertical and horizontal gap reduction at 1 year.


Assuntos
Perda do Osso Alveolar/cirurgia , Projeto do Implante Dentário-Pivô/métodos , Implantação Dentária Endóssea/métodos , Implantes Dentários , Adulto , Idoso , Idoso de 80 Anos ou mais , Perda do Osso Alveolar/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fumar/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA