RESUMO
BACKGROUND: Percutaneous left atrial appendage (LAA) occlusion is effective for stroke prevention in patients with atrial fibrillation. LAA can have a complex anatomy, such as multiple lobes or a large orifice, which may render it unsuitable for occlusion using regular devices. We aimed to investigate the feasibility, safety, and short-term efficacy of the small-umbrella LAmbre device for morphologically complicated LAA. METHODS: We retrospectively enrolled 129 consecutive patients who underwent LAA occlusion using the LAmbre device; the small-umbrella LAmbre device was used in 30 of these patients. We analyzed patients' characteristics, procedural details, and outcomes. RESULTS: Twenty-two patients (73.3%) had multilobed (≥ 2) LAA. The umbrella of the occluder was anchored in the branch in 9 patients and in the common trunks of branches in 13 patients. The landing zone and orifice diameters were 19.0 ± 4.39 mm and 27.4 ± 3.95 mm, respectively. The sizes of the umbrella and occluder cover were 22.0 ± 3.42 mm and 34.3 ± 2.75 mm, respectively. At 3-month follow-up transesophageal echocardiography in 24 patients, no peri-device residual flow was reported. Device thrombosis was detected in one patient at 3 months and disappeared after 3 months of anticoagulation. Ischemic stroke occurred in one patient; no other adverse events were reported. CONCLUSIONS: Occlusion of morphologically complicated LAA using the small-umbrella LAmbre device was feasible, safe, and effective in patients with atrial fibrillation in this study. This occluder provides an alternative for patients who cannot be treated with regular-sized LAA occlusion devices.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana/efeitos adversos , Humanos , Estudos Retrospectivos , Dispositivo para Oclusão Septal/efeitos adversos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/prevenção & controle , Resultado do TratamentoRESUMO
Objectives: This study aimed to assess the depression and anxiety status and their association with sleep disturbance among one single center Chinese inpatients with arrhythmia and help cardiologists better identify patients who need psychological care. Methods: A cross-sectional survey was conducted among 495 inpatients with arrhythmia treated in Fuwai Hospital from October to December 2019. The psychological status and sleep quality were assessed using the Zung Self-Rating Anxiety Scale (SAS), the Zung Self-Rating Depression Scale (SDS) and the Pittsburgh Sleep Quality Index (PSQI). Multivariate logistic regression was used to identify the potential risk factors for anxiety and depression. Results: The mean age of the participants was 52.8 ± 14.4 years, and 58.0% were male. Approximately 18.3% were in an anxious state, and 33.5% were in a depressive state. In multivariate logistic regression, age from 50 to 59 (p = 0.03), unemployment (p = 0.026) and sleep disturbance (p < 0.001) were the risk factors for anxiety status. Cardiac implanted electronic devices (CIEDs) (p = 0.004) and sleep disturbance (p < 0.001) were the risk factors for depression status. A total of 150 patients (30.3%) were categorized as having poor sleep quality (PSQI > 7). The adjusted odds ratio (OR) of having poor sleep quality was 4.30-fold higher in patients with both anxiety and depression (OR: 4.30; 95% confidence interval [CI]: 2.52-7.35); 2.67-fold higher in patients with depression (OR: 2.67; 95% CI: 1.78-4.00); and 3.94-fold higher in patients with anxiety (OR: 3.94; 95% CI: 2.41-6.44). Conclusions: Psychological intervention is critical for Chinese inpatients with arrhythmia, especially for patients aged 50-59, unemployed, or those using CIEDs. Poor sleep quality could be an important risk factor linked to psychological disturbances.
RESUMO
This study aimed to assess the incidence, clinical implications, and treatment strategies of device-related thrombus (DRT) following catheter ablation and percutaneous left atrial appendage occlusion combined in one intervention. A meta-analysis of observational studies was conducted to evaluate the incidence rates, treatment strategies, and clinical implications of DRT. A total of 21 studies describing DRT events and 1 case were included in the current study. The 21 included studies comprised 3 multi-center registries and 18 single-center registries, and we also included 1 case report analyzing the characteristics of DRT. The pooled incidence of DRT in one-stop intervention was 18/1,708 (1.2%; range = 0%-7.3%; 95% CI = 0.7%-1.8%; I 2 = 0). Of these DRT events, 56.25% were diagnosed in the first 3 months after the procedure. All cases were diagnosed via trans-esophagus echocardiogram. All of the patients diagnosed with DRT were prescribed anticoagulation treatment, and 63% (12/19) of the events were reported with an outcome of complete thrombus resolution. The duration of anticoagulation treatment varied greatly, from 30 days to 6 months. Unknown clinical events were reported relating to DRT. Device-related thrombus is an uncommon complication of one-stop intervention. It occurs mainly in the early period following the procedure. Anticoagulation appears to be an appropriate treatment method for dissolving occurrences of DRT.
Assuntos
Fibrilação Atrial/complicações , Trombose/etiologia , Feminino , Humanos , Incidência , Masculino , Fatores de Risco , Trombose/patologia , Resultado do TratamentoRESUMO
Background: A variety of supraventricular arrhythmias (SVAs) may occur in patients with hypertrophic cardiomyopathy (HCM). The characteristics and long-term ablation outcomes of different types of SVAs in HCM have not been comprehensively investigated. Methods: We retrospectively enrolled 101 consecutive patients with HCM who were referred to the electrophysiology and arrhythmia service from May 2010 to October 2020. The clinical features and ablation outcomes were analyzed. Results: Seventy-eight patients had SVAs, which comprised 50 (64.1%) cases of atrial fibrillation (AF), 16 (20.5%) of atrial flutter (AFL), 15 (19.2%) of atrioventricular reentrant tachycardia (AVRT), 11 (14.1%) of atrial arrhythmia (AT), and 3 (3.8%) of atrioventricular nodal reentrant tachycardia (AVNRT). Thirty-four patients underwent catheter ablation and were followed up for a median (interquartile range) of 58.5 (82.9) months. There was no recurrence in patients with non-AF SVAs. In patients with AF, the 1- and 7-year AF-free survival rates were 87.5 and 49.5%, respectively. A receiver operator characteristic analysis showed that a greater left ventricular end-diastolic dimension (LVEDD) was associated with a higher recurrence of AF, with an optimum cutoff value of 47 mm (c-statistic = 0.91, p = 0.011, sensitivity = 1.00, specificity = 0.82). In Kaplan-Meier analysis, patients with a LVEDD ≥ 47 mm had worse AF-free survival than those with a LVEDD <47 mm (log-rank p = 0.014). Conclusions: In this unique population of HCM, AF was the most common SVA, followed in order by AFL, AVRT, AT, and AVNRT. The long-term catheter ablation outcome for non-AF SVAs in HCM is satisfactory. A greater LVEDD predicts AF recurrence after catheter ablation in patients with HCM.
RESUMO
BACKGROUND: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is an effective technique used to precisely detect enlarged mediastinal lymph nodes. The efficacy of EBUS-TBNA versus standard modalities for the diagnosis of sarcoidosis remains to be elucidated. In this meta-analysis, we compared the efficacies of these methods. METHODS: We searched PubMed, Embase, The Cochrane Library, Wanfang, Cpvip, CNKI, and the bibliographies of the relevant references. We analyzed the data obtained with Revman 5.2 (Nordic Cochrane Center, Copenhagen, Denmark) and Stata 12.0 software (Stata Corporation, College Station, TX, USA). The Mantel-Haenszel method was used to calculate the pooled odds ratio (OR) and 95% confidence intervals (CIs). RESULTS: Sixteen studies with a total of 1823 participants met the inclusion criteria, and data were extracted regarding the diagnostic yield of each approach. The ORs for EBUS-TBNA versus transbronchial lung biopsy (TBLB) for the diagnosis of sarcoidosis ranged from 0.26 to 126.58, and the pooled OR was 5.89 (95% CI, 2.20-15.79, P = 0.0004). These findings indicated that EBUS-TBNA provided a much higher diagnostic yield than TBLB. The pooled OR for EBUS-TBNA + TBLB + endobronchial biopsy (EBB) versus TBNA + TBLB + EBB was 1.54 (95% CI, 0.61-3.93, P = 0.36), implying that there was no significant difference between their diagnostic yields. However, clinical heterogeneity was reflected in the nature of the studies and in the operative variables. CONCLUSIONS: The results of this meta-analysis suggest that EBUS-TBNA + TBLB + EBB could be used for the diagnosis of sarcoidosis, if available. At medical centers without EBUS-TBNA, TBNA + TBLB + EBB could be used instead.