Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Zhongguo Gu Shang ; 22(7): 519-21, 2009 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-19705717

RESUMO

OBJECTIVE: To investigate the mechanical characteristics of new anatomic plate of distal tibia from view of biomechanics. METHODS: Twelve fresh adult moist ankle specimens were randomly divided into four block groups (every group had 3 specimens), 3 tibial specimens as a normal control (normal group N), 9 specimens were resulted in unstable distal tibial Pilon fracture. Using steel plate fixation with a new anatomic distal tibial plate (group A), reconstruction plate (group B), clover plate (group C). Group B and group C as control group to test the remote axial compressive strength, remote axial stiffness, reversing biomechanical properties, contacted characteristics of the tibial astragaloid articular surface. RESULTS: The remote axial compressive strength, remote axial stiffness, reversing biomechanical properties, contacted characteristics of tibial astragaloid articular surface the in distal tibial Pilon fracture instability of group A were near normal group N (P>0.05). Group A was best than group B and C (P<0.05). CONCLUSION: The new anatomic plate of distal tibia was relatively strong, which can reach effective and stable fixation for unstable distal tibial Pilon fracture.


Assuntos
Tíbia/química , Fraturas da Tíbia/cirurgia , Fenômenos Biomecânicos , Placas Ósseas , Fixação Interna de Fraturas , Humanos , Técnicas In Vitro , Tíbia/lesões , Tíbia/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA