1.
J Orthop Sci ; 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37500402

RESUMO

BACKGROUND: Bone graft fusion is a major concern among surgeons after Anterior Cervical Discectomy and Fusion (ACDF) surgery as non-fusion may lead to further physical and drug therapies. METHODS: The related risk elements of non-fusion of bone graft in ACDF surgery were retrospectively assessed. Patients receiving ACDF operation in our hospital from January 2015 to December 2019 were retrospectively analyzed. According to the criteria, 107 study subjects were recruited with a total of 164 surgical segments. The general information of patients, bone graft materials, imaging parameters, and clinical efficacy was recorded. T-test, chi-square test and binary logistic regression evaluation were employed to explore the risk factors of bone graft nonunion. RESULTS: Low housefield unit (HU) value, diabetes, allogeneic bone, and hydroxyapatite (HA) artificial bone could be risk factors for bone graft fusion in ACDF surgery. Further multivariate analysis was performed and confirmed those related factors of bone graft non-fusion including low HU value (non-fusion rate: 32.53% [27/83], OR = 5.024, p = 0.025), diabetes (non-fusion rate: 53.33% [8/15], OR = 4.776, p = 0.031), allogeneic bone (18.57% [13/70], OR = 3.964, p = 0.046), and artificial bone (68.29% [28/41], OR = 50.550, p < 0.01). CONCLUSION: By looking at bone graft fusion, selecting autologous iliac bone is an ideal selection to avoid non-fusion of bone graft in ACDF. Diabetes was more important predictor of bone graft nonunion than low HU value. Larger sample size and longer follow-up are required to further confirm these findings in the future.

2.
Arch Orthop Trauma Surg ; 143(7): 3669-3675, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35852598

RESUMO

OBJECTIVES: This study was aimed to measure the application of W-shaped acetabular angular plate (WAAP) through direct posterior approach (DPA) on the reconstruction of acetabular posterior wall fractures when compared with reconstruction plates. PATIENTS AND METHODS: A retrospective study was performed on patients treated with the WAAP or reconstruction plates via the DPA. The intraoperative data of operative time, blood loss and radiation exposure times were recorded. Radiographs of the pelvis and CT scan were obtained within one week post-operation to assess the reduction quality. The clinical outcome was evaluated by the modified Merle d'Aubigne and Postel score. RESULTS: From May 2016 to October 2019, a total of 41 patients with simple acetabular posterior wall fractures were included in this study, 22 from the WAAP group and 19 from the reconstruction plates group. There were no significant differences between the two group in age, gender, time from injury to operation, cause of injuries, length of incision and follow-up time (P > 0.05). In comparison with the reconstruction plates group, the average operation time of the WAAP group was significantly shorter (46.1 ± 12.7 min vs 59.2 ± 17.4 min, P < 0.05), the average radiation exposure times were significantly less (2.3 ± 0.6 vs 3.6 ± 1.0, P < 0.001), the average blood loss was significantly less (240 ± 98.9 ml vs 301.1 ± 66.6 ml, P < 0.05). According to Matta radiology criteria and the modified Merle d' Aubigne and Postel score, no significant difference was observed between the two group, as for the quality of reduction and function outcomes. CONCLUSION: The application of WAAP through DPA showed satisfactory preliminary clinical outcomes, showing promise to be an alternative technique for the treatment of acetabular posterior wall fractures.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Fraturas da Coluna Vertebral , Humanos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/lesões , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Fraturas do Quadril/cirurgia
3.
BMC Musculoskelet Disord ; 21(1): 147, 2020 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-32131792

RESUMO

BACKGROUND: Pelvic fractures are rare in toddlers but are often associated with other injuries that make treatment difficult. Conservative treatment has been used with moderate success, but it is unclear if surgical correction could confer additional benefits and improve patient outcomes. The purpose of this study was to report authors' experience using the lateral-rectus approach (LRA) for surgical correction of unstable pelvic fractures in two toddlers. METHODS: We retrospectively analyzed the cases of two toddlers with unstable pelvic fractures who underwent surgery through the LRA between April 2016 and October 2018. Patients' characteristics, fracture type, mechanism of injury, Injury Severity Score (ISS), operative time, intra-operative blood loss, and post-operative complications were assessed. Pelvic asymmetry, degree of deformity, Cole scoring criteria and modified Barthel Index (MBI) were used to evaluate radiographic and functional outcomes. RESULTS: Successful surgical treatment was performed using the LRA, external fixation, and sacroiliac screw fixation. Surgery duration was 180 min on average, with an average intra-operative bleeding of 250 ml. There were no iatrogenic nerve injuries or infections. Pelvic asymmetry a week after surgery was 0.5 cm on average and dropped to 0.3 cm on average at the end of the follow-up period. The deformity index of the pelvis dropped from an average of 0.035 a week after surgery to 0.02 at the end of the follow-up period. The mean MBI was 100 in the last follow-up, and Cole scoring criteria categorized both patients as being in excellent condition. All patients achieved radiological bone union without discrepancy in length of the lower limbs. Neither patient had loss of reduction nor evidence of low back pain during the mean follow-up period of 22 months. CONCLUSIONS: Pelvic fracture in toddlers is rare, and surgical treatment requires careful consideration. The lateral-rectus approach was proven as a viable alternative for managing unstable pelvic fractures in toddlers, with minimal blood loss and risk of nerve injury. Furthermore, anterior external fixation and posterior sacroiliac screw fixation would be adequate for this population, with excellent final outcome.


Assuntos
Parafusos Ósseos , Fixadores Externos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Pré-Escolar , Feminino , Seguimentos , Fraturas Ósseas/diagnóstico por imagem , Humanos , Lactente , Ossos Pélvicos/diagnóstico por imagem , Estudos Retrospectivos
4.
BMC Musculoskelet Disord ; 21(1): 451, 2020 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-32650750

RESUMO

BACKGROUND: Complicated acetabular fractures comprise the most challenging field for orthopedists. The purpose of this study was to develop three-dimensional printed patient-specific (3DPPS) Ti-6Al-4 V plates to treat complicated acetabular fractures involving quadrilateral plate (QLP) disruption and to evaluate their efficacy. METHODS: Fifty patients with acetabular fractures involving QLP disruption were selected between January 2016 and June 2017. Patients were divided into a control group (Group A, 35 patients) and an experimental group (Group B, 15 patients), and were treated by the conventional method of shaping reconstruction plates or with 3DPPS Ti-6AL-4 V plates, respectively. The efficacy of Ti-6AL-4 V plates was evaluated by blood loss, operative time, reduction quality, postoperative residual displacement, and complications. RESULTS: The operative time and blood loss in Group B were reduced compared to Group A, and the difference was statistically significant (P < 0.05). There was no significant difference in reduction quality between the two groups (P > 0.05). Reduction quality in Group B was anatomic in 10 (66.7%), satisfactory in four (26.7%), and poor in one (6.7%). In Group A, they were anatomic in 18 (51.4%), satisfactory in 13 (37.1%), and poor in four (11.4%). Residual displacement in Group B was less than that in Group A, and the difference was statistically significant (P < 0.05). In Group B, one case exhibited loosening of the pubic screw postoperatively. In Group A, there was one case of wound infection, one of deep vein thrombosis (DVT) in the ipsilateral lower limb, one case of traumatic arthritis and two obturator nerve injuries. CONCLUSIONS: The 3DPPS Ti-6AL-4 V plate is a feasible, accurate and effective implant for acetabular fracture treatment.


Assuntos
Fraturas Ósseas , Fraturas do Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Placas Ósseas , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Impressão Tridimensional
5.
Health Care Sci ; 2(1): 36-44, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38939740

RESUMO

Objectives: This study aimed to investigate the symmetry of the Chinese pelvis. Methods: Computed tomography scan images of each of 50 Chinese pelvises were converted to 3D models and the left sides of the pelvises were reflected on Mimics software. Then, the reflected left side model was aligned with the right side using the closest point algorithm function of Geomagic software to perform symmetry analysis. The volume and surface area of either side of the pelvises were also calculated. The mean standard deviation (SD), the mean percentage of permissible deviations within the ±2 mm range, the percentage differences in volume and surface area were measured to compare pelvic symmetry. In addition, the distribution of pelvic bilateral symmetry associated with both age and sex were compared. Results: The mean SD was 1.15 ± 0.16 mm and the mean percentage of permissible deviations was 90.82% ± 4.67%. The deviation color maps showed that the specific areas of asymmetry were primarily localized to major muscle or ligament attachment sites and the sacroiliac joint surfaces. There was no significant difference between the bilateral sides of the pelvis in either volume or surface area. Additionally, no difference in any indexes was exhibited in relation to sex and age distribution. Conclusion: Our results demonstrated that the pelvis has high bilateral symmetry, which confirmed the potential of using contralateral pelvic models to create fully patient-specific and custom-made pelvic implants applicable for the treatment of fracture and bony destruction.

6.
Adv Clin Exp Med ; 29(4): 459-468, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32348038

RESUMO

BACKGROUND: Three-dimensional (3D) printing of an acetabular wing-plate is a new minimally invasive surgical technique for complex acetabular fractures. OBJECTIVES: To investigate the biomechanical stability of 3D printing acetabular wing-plates. The results were compared with 2 conventional fixation systems. MATERIAL AND METHODS: Eighteen fresh frozen cadaveric pelvises with both column fractures were randomly divided to 3 groups: A - iliosciatic plates fixation system; B - 3D printing plates; C - 2 parallel reconstruction plates fixation system. These constructions were loaded onto a biomechanical testing machine. Longitudinal displacement and stiffness values of the constructs were measured to estimate their stability. RESULTS: When the load force reached 700 N, Group A was superior to Group B in the longitudinal displacement of point 1 (p > 0.05). The longitudinal displacement of point 2 showed no significant differences among Groups A, B and C, and the displacement of the fracture line over point 3 showed no significant differences between Groups A and B (p > 0.05). The axial stiffness of Groups A, B and C were 122.4800 ±8.8480 N/mm, 168.4830 ±14.8091 N/mm and 83.1300 ±3.8091 N/mm, respectively. Group B was significantly stiffer than A and C (p < 0.05). Loads at failure of internal fixation were 1378.83 ±34.383 N, 1516.83 ±30.896 N and 1351.00 ±26.046 N for Groups A, B and C, respectively. Group B was significantly superior to Groups A and C (p > 0.05). CONCLUSIONS: Customized 3D printing acetabular-wing plates provide stability for acetabular fractures compared to intraspecific buttressing fixation.


Assuntos
Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Impressão Tridimensional , Acetábulo/lesões , Fenômenos Biomecânicos , Fêmur/fisiopatologia , Fêmur/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Resultado do Tratamento , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA