Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nature ; 573(7775): 558-562, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31554980

RESUMO

High-pressure transitions are thought to modify hydrogen molecules to a molecular metallic solid and finally to an atomic metal1, which is predicted to have exotic physical properties and the topology of a two-component (electron and proton) superconducting superfluid condensate2,3. Therefore, understanding such transitions remains an important objective in condensed matter physics4,5. However, measurements of the crystal structure of solid hydrogen, which provides crucial information about the metallization of hydrogen under compression, are lacking for most high-pressure phases, owing to the considerable technical challenges involved in X-ray and neutron diffraction measurements under extreme conditions. Here we present a single-crystal X-ray diffraction study of solid hydrogen at pressures of up to 254 gigapascals that reveals the crystallographic nature of the transitions from phase I to phases III and IV. Under compression, hydrogen molecules remain in the hexagonal close-packed (hcp) crystal lattice structure, accompanied by a monotonic increase in anisotropy. In addition, the pressure-dependent decrease of the unit cell volume exhibits a slope change when entering phase IV, suggesting a second-order isostructural phase transition. Our results indicate that the precursor to the exotic two-component atomic hydrogen may consist of electronic transitions caused by a highly distorted hcp Brillouin zone and molecular-symmetry breaking.


Assuntos
Hidrogênio/química , Modelos Moleculares , Pressão , Eletrônica , Difração de Nêutrons , Transição de Fase , Difração de Raios X
2.
J Synchrotron Radiat ; 31(Pt 3): 508-516, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38530832

RESUMO

Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement. For coherent diffraction imaging it is advantageous to increase the available field of view by increasing the spatial coherence length (SCL) of a beam exiting such a DCM. Here, Talbot interferometry data together with ray-tracing simulations for a (+ - - +) four-reflection experimental arrangement are presented, wherein the first two reflections are in the DCM and the final fourth reflection is asymmetric at grazing exit. Analyses of the interferometry data combined with the simulations show that compared with the beam exiting the DCM a gain of 76% in the SCL was achieved, albeit with a factor of 20 reduction in flux density, which may not be a severe penalty at a synchrotron beamline. Previous efforts reported in the literature to increase the SCL that employed asymmetric crystal diffraction at grazing incidence are also discussed. A much reduced SCL is found presently in simulations wherein the same asymmetric crystal is set for grazing incidence instead of grazing exit. In addition, the present study is compared and contrasted with two other means of increasing the SCL. These are (i) focusing the beam onto an aperture to act as a secondary source, and (ii) allowing the beam to propagate in vacuum an additional distance along the beamline.

3.
J Synchrotron Radiat ; 31(Pt 4): 751-762, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38904936

RESUMO

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

4.
J Synchrotron Radiat ; 29(Pt 1): 159-166, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34985433

RESUMO

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

5.
Opt Lett ; 47(3): 565-568, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35103672

RESUMO

Most polarization-sensitive photodetectors detect either linearly polarized (LP) or circularly polarized (CP) light. Here, we experimentally demonstrate a multiple-polarization photodetector based on a hybrid organic-inorganic perovskite (HOIP) metasurface, which is sensitive to both LP and CP light simultaneously. The perovskite metasurface is composed of a HOIP antenna array on a single-crystal HOIP film. Owing to the antenna anisotropy, the absorption of linearly polarized light at the metasurface depends on the polarization angle; also, due to the mirror asymmetry of the antenna elements, the metasurface is also sensitive to different circular polarizations. Polarization-dependent photocurrent responses to both LP and CP light are detected. Our results highlight the potential of perovskite metasurfaces for integrated photoelectric applications.

6.
J Synchrotron Radiat ; 28(Pt 4): 1184-1192, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34212883

RESUMO

The IRIXS Spectrograph represents a new design of an ultra-high-resolution resonant inelastic X-ray scattering (RIXS) spectrometer that operates at the Ru L3-edge (2840 eV). First proposed in the field of hard X-rays by Shvyd'ko [(2015), Phys. Rev. A, 91, 053817], the X-ray spectrograph uses a combination of laterally graded multilayer mirrors and collimating/dispersing Ge(111) crystals optics in a novel spectral imaging approach to overcome the energy resolution limitation of a traditional Rowland-type spectrometer [Gretarsson et al. (2020), J. Synchrotron Rad. 27, 538-544]. In combination with a dispersionless nested four-bounce high-resolution monochromator design that utilizes Si(111) and Al2O3(110) crystals, an overall energy resolution better than 35 meV full width at half-maximum has been achieved at the Ru L3-edge, in excellent agreement with ray-tracing simulations.

7.
J Synchrotron Radiat ; 27(Pt 4): 963-969, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33566005

RESUMO

Resonant inelastic X-ray scattering (RIXS) is increasingly playing a significant role in studying highly correlated systems, especially since it was proven capable of measuring low-energy magnetic excitations. However, despite high expectations for experimental evidence of novel magnetic phases at high pressure, unequivocal low-energy spectral signatures remain obscured by extrinsic scattering from material surrounding the sample in a diamond anvil cell (DAC): pressure media, Be gasket and the diamond anvils themselves. A scattered X-ray collimation based medium-energy resolution (∼100 meV) analyzer system for a RIXS spectrometer at the Ir L3-absorption edge has been designed and built to remediate these difficulties. Due to the confocal nature of the analyzer system, the majority of extrinsic scattering is rejected, yielding a clean low-energy excitation spectrum of an iridate Sr2IrO4 sample in a DAC cell. Furthermore, the energy resolution of different configurations of the collimating and analyzing optics are discussed.

8.
J Synchrotron Radiat ; 27(Pt 6): 1553-1563, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-33147180

RESUMO

Wavefront-preserving X-ray diamond crystal optics are essential for numerous applications in X-ray science. Perfect crystals with flat Bragg planes are a prerequisite for wavefront preservation in Bragg diffraction. However, this condition is difficult to realize in practice because of inevitable crystal imperfections. Here, X-ray rocking curve imaging is used to study the smallest achievable Bragg-plane slope errors in the best presently available synthetic diamond crystals and how they compare with those of perfect silicon crystals. It is shown that the smallest specific slope errors in the best diamond crystals are about 0.08 (3) µrad mm-2. These errors are only 50% larger than the 0.05 (2) µrad mm-2 specific slope errors measured in perfect silicon crystals. High-temperature annealing at 1450°C of almost flawless diamond crystals reduces the slope errors very close to those of silicon. Further investigations are in progress to establish the wavefront-preservation properties of these crystals.

9.
Opt Express ; 28(3): 3552-3560, 2020 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-32122021

RESUMO

We experimentally demonstrate a bendable cloaking structure composed of obliquely stacked planar metallic shells that individually enclose the objects to be hidden. The ensemble of shells acts as a disordered oblique grating capable of bending along a curved structure and exhibits broadband invisibility from 0.2 to 1.0 THz. Hiding cloaked objects sized hundreds of microns could prevent the detection of certain powders that are sensitive to terahertz waves; such a cloaking structure can also be considered as a shape-changing passageway that transfers the electromagnetic waves without interfering with them. Our approach provides a unique way to achieve broadband electromagnetic invisibility.

10.
Nano Lett ; 18(3): 1896-1902, 2018 03 14.
Artigo em Inglês | MEDLINE | ID: mdl-29432022

RESUMO

In this work, we experimentally demonstrate for the first time strong localization of surface plasmon polaritons (SPPs) at visible regime in metallic nanogratings with short-range correlated disorder. By increasing the degree of disorder, the confinement of SPPs is significantly enhanced, and the effective SPP propagation length dramatically shrinks. Strong localization of SPPs eventually emerges at visible regime, which is verified by the exponentially decayed fields and the vanishing autocorrelation function of the SPPs. Physically, the short-range correlated disorder induces strong interference among multiple scattered SPPs and provides an adequate fluctuation to effective permittivity, which leads to the localization effect. Our study demonstrates a unique opportunity for disorder engineering to manipulate light on nanoscale and may achieve various applications in random nanolasing, solar energy, and strong light-matter interactions.

11.
J Synchrotron Radiat ; 25(Pt 2): 373-377, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29488915

RESUMO

A novel diced spherical quartz analyzer for use in resonant inelastic X-ray scattering (RIXS) is introduced, achieving an unprecedented energy resolution of 10.53 meV at the Ir L3 absorption edge (11.215 keV). In this work the fabrication process and the characterization of the analyzer are presented, and an example of a RIXS spectrum of magnetic excitations in a Sr3Ir2O7 sample is shown.

12.
Opt Express ; 26(1): 516-524, 2018 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-29328328

RESUMO

In this work, we demonstrate broadband integrated polarization rotator (IPR) with a series of three-layer rotating metallic grating structures. This transmissive optical IPR can conveniently rotate the polarization of linearly polarized light to any desired directions at different spatial locations with high conversion efficiency, which is nearly constant for different rotation angles. The linear polarization rotation originates from multi-wave interference in the three-layer grating structure. We anticipate that this type of IPR will find wide applications in analytical chemistry, biology, communication technology, imaging, etc.

13.
J Synchrotron Radiat ; 23(Pt 4): 880-6, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27359136

RESUMO

Advances in resonant inelastic X-ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L3-edge stands at ∼25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid-angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L3-absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X-ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27-ID at the Advanced Photon Source. X-rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X-ray measurements, ray-tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high-resolution RIXS multi-crystal analyzer system.

14.
J Synchrotron Radiat ; 20(Pt 1): 74-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23254658

RESUMO

Resonant inelastic X-ray scattering (RIXS) experiments require special sets of near-backscattering spherical diced analyzers and high-resolution monochromators for every distinct absorption-edge energy and emission line. For the purpose of aiding the design and planning of efficient RIXS experiments, comprehensive lists of suitable analyzer reflections for silicon, germanium, α-quartz, sapphire and lithium niobate crystals were compiled for a multitude of absorption edges and emission lines. Analyzers made from lithium niobate, sapphire or α-quartz offer many choices of reflections with intrinsic resolutions currently unattainable from silicon or germanium. In some cases these materials offer higher intensities at comparable resolutions. While lithium niobate, sapphire or α-quartz analyzers are still in an early stage of development, the present compilation can serve as a computational basis for assessing expected and actual performance. With regard to high-resolution monochromators, bandpass and throughput calculations for combinations of double-crystal, high-heat-load and near-backscattering high-resolution channel-cuts were assembled. The compilation of these analyzer and monochromator data is publicly available on a website.

15.
Opt Express ; 21 Suppl 3: A313-23, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-24104419

RESUMO

We report in this work that quantum efficiency can be significantly enhanced in an ultra-thin silicon solar cell coated by a fractal-like pattern of silver nano cuboids. When sunlight shines this solar cell, multiple antireflection bands are achieved mainly due to the self-similarity in the fractal-like structure. Actually, several kinds of optical modes exist in the structure. One is cavity modes, which come from Fabry-Perot resonances at the longitudinal and transverse cavities, respectively; the other is surface plasmon (SP) modes, which propagate along the silicon-silver interface. Due to the fact that several feature sizes distribute in a fractal-like structure, both low-index and high-index SP modes are simultaneously excited. As a whole effect, broadband absorption is achieved in this solar cell. Further by considering the ideal process that the lifetime of carriers is infinite and the recombination loss is ignored, we demonstrate that external quantum efficiency of the solar cell under this ideal condition is significantly enhanced. This theoretical finding contributes to high-performance plasmonic solar cells and can be applied to designing miniaturized compact photovoltaic devices.

16.
Rev Sci Instrum ; 92(7): 073105, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340408

RESUMO

We present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES) [Mattern et al., Rev. Sci. Instrum. 83(2), 023901 (2012)]. The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kß x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

17.
J Synchrotron Radiat ; 17(3): 352-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20400833

RESUMO

A theoretical model to trace X-rays through an L-shaped (nested or Montel Kirkpatrick-Baez mirrors) laterally graded multilayer mirror to be used in a synchrotron application is presented. The model includes source parameters (size and divergence), mirror figure (parabolic and elliptic), multilayer parameters (reflectivity, which depends on layer material, thickness and number of layers) and figure errors (slope error, roughness, layer thickness fluctuation Deltad/d and imperfection in the corners). The model was implemented through MATLAB/OCTAVE scripts, and was employed to study the performance of a multilayer mirror designed for the analyzer system of an ultrahigh-resolution inelastic X-ray scattering spectrometer at National Synchrotron Light Source II. The results are presented and discussed.

18.
Phys Rev Lett ; 105(24): 243901, 2010 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-21231526

RESUMO

From first-principles computations we reveal that metallic gratings consisting of narrow slits may become transparent for extremely broad bandwidths under oblique incidence. This phenomenon can be explained by a concrete picture in which the incident wave drives free electrons on the conducting surfaces and part of the slit walls to form spoof surface plasmons (SSPs). The SSPs then propagate on the slit walls but are abruptly discontinued by the bottom edges to form oscillating charges that emit the transmitted wave. This picture explicitly demonstrates the conversion between light and SSPs and indicates clear guidelines for enhancing SSP excitation and propagation. Making structured metals transparent may lead to a variety of applications.

19.
J Opt Soc Am A Opt Image Sci Vis ; 27(4): 718-29, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20360814

RESUMO

Interactions between light and conducting microstructures or nanostructures can result in a variety of novel phenomena, but their underlying mechanisms have not been completely understood. From calculations of surface charge density waves on conducting gratings and by comparing them with classical surface plasmons, we revealed a general yet concrete picture regarding the coupling of light to free electron oscillation on structured conducting surfaces that can lead to oscillating subwavelength charge patterns (i.e., structured surface plasmons). New wavelets emitted from these light sources then destructively interfere to form evanescent waves. This principle, usually combined with other mechanisms, is mainly a geometrical effect that can be universally involved in light scattering from all periodic and non-periodic structures containing free electrons. This picture may provide clear guidelines for developing conductor-based nano-optical devices.

20.
Med Hypotheses ; 140: 109643, 2020 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-32163794

RESUMO

BACKGROUND: Malignant transformation is a rare and late complication of chronic osteomyelitis. This study presented the results of six cases of carcinogenesis and precancerosis transformations arising from chronic osteomyelitis. METHODS: Patients who were diagnosed as chronic osteomyelitis and treated in our division were retrospectively retrieved from electronic case system of our hospital. A total of six cases of chronic osteomyelitis patients, confirming with pathological results were included. Not only the characteristics and causes of chronic osteomyelitis, but also time from diagnosis to malignancy, histological types, therapeutic choices and results of treatment were fully incorporated to further study this disease. RESULTS: All 6 cases with chronic osteomyelitis included in the study were male, with average age of 55.67 year-old (ranging from 48 to 66). The average time from onset of osteomyelitis to carcinomatous change was 31 years (ranging from 9 to 50). Two thirds of patients had explicit infection source of trauma, whereas the rest cases had no obvious culprits before osteomyelitis emerging. All 3 patients diagnosed as carcinoma were performed with proximal limb amputation, but therapy strategies varied in the remaining 3 patients in precancerosis stage. After amputation, 1 patient had carcinoma relapsed at the lower portion of his femur. CONCLUSION: Although carcinomatous degeneration exists as a rare complication in chronic osteomyelitis, some suspicious conditions such as failure treatment of refractory ulcer and bulking of cauliflower-like mass should be taken cautiously. Early diagnosis and proximal amputation are essential for prognosis and clinical results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA