Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 46(3): 342-345, 2022 May 30.
Artigo em Chinês | MEDLINE | ID: mdl-35678449

RESUMO

OBJECTIVE: To solve the ESB bus performance and safety problems caused by the explosive growth of the hospital's business, and to ensure the stable interaction of the hospital's business system. METHODS: Taking the construction of our hospital's information system as an example, we used AlwaysOn, load balancing and other technologies to optimize the ESB bus architecture to achieve high availability and scalability of the hospital's ESB bus. RESULTS: The ESB bus high-availability architecture effectively eliminates multiple points of failure. Compared with the traditional dual-machine Cluster solution, the security is significantly improved. The nodes based on load balancing can be scaled horizontally according to the growth of the hospital's business volume. CONCLUSIONS: The construction of the ESB bus high-availability architecture effectively solves the performance and security issues caused by business growth, and provides practical experience for medical information colleagues. It has certain guiding significance for the development of regional medical information.


Assuntos
Sistemas de Informação Hospitalar , Sistemas de Informação
2.
BMC Gastroenterol ; 21(1): 185, 2021 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-33879095

RESUMO

BACKGROUND: Since December 2019, China has experienced a public health emergency from the coronavirus disease, which has become a pandemic and is impacting the care of cancer patients worldwide. This study evaluated the impact of the pandemic on colorectal cancer (CRC) patients at our center and aimed to share the lessons we learned with clinics currently experiencing this impact. METHODS: We retrospectively collected data on CRC patients admitted between January 1, 2020 and May 3, 2020; the control group comprised patients admitted between January 1, 2019 and May 3, 2019. RESULTS: During the pandemic, outpatient volumes decreased significantly, especially those of nonlocal and elderly patients, whereas the number of patients who received chemotherapy and surgery remained the same. During the pandemic, 710 CRC patients underwent curative resection. The proportion of patients who received laparoscopic surgeries was 49.4%, significantly higher than the 39.5% during the same period in 2019. The proportion of major complication during the pandemic was not significantly different from that of the control group. The mean hospital stay was significantly longer than that of the control group. CONCLUSIONS: CRC patients confirmed to be infection-free can receive routine treatment. Using online medical counseling and appropriate identification, treatment and follow-up can be effectively maintained. Adjuvant and palliative chemotherapy should not be discontinued. Endoscopic polypectomy, elective, palliative, and multidisciplinary surgeries can be postponed, while curative surgery should proceed as usual. For elderly CRC patients, endoscopic surgery and neoadjuvant radiotherapy are recommended.


Assuntos
COVID-19/epidemiologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/terapia , Idoso , China/epidemiologia , Humanos , Pandemias , Estudos Retrospectivos
3.
IEEE Trans Neural Syst Rehabil Eng ; 24(1): 180-91, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26276996

RESUMO

The micro-electronic neural bridge (MENB) aims to rebuild lost motor function of paralyzed humans by routing movement-related signals from the brain, around the damage part in the spinal cord, to the external effectors. This study focused on the prototype system design of the MENB, including the principle of the MENB, the neural signal detecting circuit and the functional electrical stimulation (FES) circuit design, and the spike detecting and sorting algorithm. In this study, we developed a novel improved amplitude threshold spike detecting method based on variable forward difference threshold for both training and bridging phase. The discrete wavelet transform (DWT), a new level feature coefficient selection method based on Lilliefors test, and the k-means clustering method based on Mahalanobis distance were used for spike sorting. A real-time online spike detecting and sorting algorithm based on DWT and Euclidean distance was also implemented for the bridging phase. Tested by the data sets available at Caltech, in the training phase, the average sensitivity, specificity, and clustering accuracies are 99.43%, 97.83%, and 95.45%, respectively. Validated by the three-fold cross-validation method, the average sensitivity, specificity, and classification accuracy are 99.43%, 97.70%, and 96.46%, respectively.


Assuntos
Biomimética/instrumentação , Redes de Comunicação de Computadores/instrumentação , Terapia por Estimulação Elétrica/instrumentação , Eletroencefalografia/instrumentação , Eletrônica/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Algoritmos , Sistemas Computacionais , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Miniaturização , Projetos Piloto , Terapia Assistida por Computador/instrumentação
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2015: 1671-4, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26736597

RESUMO

In this paper, a four-channel pulse-triggered functional electrical stimulator using complementary current source and time division output method is proposed for the research and application of functional electrical stimulation (FES). The high-voltage compliance and output impedance is increased by adopting the complementary current source, which can also realize the linear voltage-to-current conversion and high channel isolation. A high-voltage analog switch chip MAX14803, combined with a FIFO queue algorithm in the microprocessor, is used to setup the H-bridge and multiplexers for the four-channel time division multiplexing output. With this method, the size and cost of the key components are reduced greatly. The stimulating core circuit area is 30 × 50 mm(2). According to the experiments, the stimulator can achieve the four-channel charge-balanced biphasic stimulation with a current range between 0 and 60 mA and a single-phase pulse amplitude up to 60 V.


Assuntos
Terapia por Estimulação Elétrica/instrumentação , Impedância Elétrica , Fontes de Energia Elétrica , Eletrodos , Hemiplegia/terapia , Humanos , Microcomputadores , Software
SELEÇÃO DE REFERÊNCIAS