1.
Gastrointest Endosc ; 91(4): 868-878.e3, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31655045

RESUMO

BACKGROUND AND AIMS: The Endoscopic Resection Group of the Spanish Society of Endoscopy (GSEED-RE) model and the Australian Colonic Endoscopic Resection (ACER) model were proposed to predict delayed bleeding (DB) after EMR of large superficial colorectal lesions, but neither has been validated. We validated and updated these models. METHODS: A multicenter cohort study was performed in patients with nonpedunculated lesions ≥20 mm removed by EMR. We assessed the discrimination and calibration of the GSEED-RE and ACER models. Difficulty performing EMR was subjectively categorized as low, medium, or high. We created a new model, including factors associated with DB in 3 cohort studies. RESULTS: DB occurred in 45 of 1034 EMRs (4.5%); it was associated with proximal location (odds ratio [OR], 2.84; 95% confidence interval [CI], 1.31-6.16), antiplatelet agents (OR, 2.51; 95% CI, .99-6.34) or anticoagulants (OR, 4.54; 95% CI, 2.14-9.63), difficulty of EMR (OR, 3.23; 95% CI, 1.41-7.40), and comorbidity (OR, 2.11; 95% CI, .99-4.47). The GSEED-RE and ACER models did not accurately predict DB. Re-estimation and recalibration yielded acceptable results (GSEED-RE area under the curve [AUC], .64 [95% CI, .54-.74]; ACER AUC, .65 [95% CI, .57-.73]). We used lesion size, proximal location, comorbidity, and antiplatelet or anticoagulant therapy to generate a new model, the GSEED-RE2, which achieved higher AUC values (.69-.73; 95% CI, .59-.80) and exhibited lower susceptibility to changes among datasets. CONCLUSIONS: The updated GSEED-RE and ACER models achieved acceptable prediction levels of DB. The GSEED-RE2 model may achieve better prediction results and could be used to guide the management of patients after validation by other external groups. (Clinical trial registration number: NCT03050333.).


Assuntos
Ressecção Endoscópica de Mucosa , Austrália , Estudos de Coortes , Colonoscopia , Neoplasias Colorretais/cirurgia , Humanos , Fatores de Risco
2.
Clin Gastroenterol Hepatol ; 14(8): 1140-7, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27033428

RESUMO

BACKGROUND & AIMS: After endoscopic mucosal resection (EMR) of colorectal lesions, delayed bleeding is the most common serious complication, but there are no guidelines for its prevention. We aimed to identify risk factors associated with delayed bleeding that required medical attention after discharge until day 15 and develop a scoring system to identify patients at risk. METHODS: We performed a prospective study of 1214 consecutive patients with nonpedunculated colorectal lesions 20 mm or larger treated by EMR (n = 1255) at 23 hospitals in Spain, from February 2013 through February 2015. Patients were examined 15 days after the procedure, and medical data were collected. We used the data to create a delayed bleeding scoring system, and assigned a weight to each risk factor based on the ß parameter from multivariate logistic regression analysis. Patients were classified as being at low, average, or high risk for delayed bleeding. RESULTS: Delayed bleeding occurred in 46 cases (3.7%, 95% confidence interval, 2.7%-4.9%). In multivariate analysis, factors associated with delayed bleeding included age ≥75 years (odds ratio [OR], 2.36; P < .01), American Society of Anesthesiologist classification scores of III or IV (OR, 1.90; P ≤ .05), aspirin use during EMR (OR, 3.16; P < .05), right-sided lesions (OR, 4.86; P < .01), lesion size ≥40 mm (OR, 1.91; P ≤ .05), and a mucosal gap not closed by hemoclips (OR, 3.63; P ≤ .01). We developed a risk scoring system based on these 6 variables that assigned patients to the low-risk (score, 0-3), average-risk (score, 4-7), or high-risk (score, 8-10) categories with a receiver operating characteristic curve of 0.77 (95% confidence interval, 0.70-0.83). In these groups, the probabilities of delayed bleeding were 0.6%, 5.5%, and 40%, respectively. CONCLUSIONS: The risk of delayed bleeding after EMR of large colorectal lesions is 3.7%. We developed a risk scoring system based on 6 factors that determined the risk for delayed bleeding (receiver operating characteristic curve, 0.77). The factors most strongly associated with delayed bleeding were right-sided lesions, aspirin use, and mucosal defects not closed by hemoclips. Patients considered to be high risk (score, 8-10) had a 40% probability of delayed bleeding.


Assuntos
Técnicas de Apoio para a Decisão , Ressecção Endoscópica de Mucosa/efeitos adversos , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Espanha , Adulto Jovem