1.
Heliyon ; 10(8): e29719, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38681575

RESUMO

The gadolinium-based contrast agent DOTA-Gd is clinically used in combination with local anesthetics for direct magnetic resonance arthrography. It remains unclear whether gadolinium uptake into cartilage is influenced by co-administration of bupivacaine or ropivacaine and whether DOTA-Gd alters their chondrotoxicity. Gadolinium quantification of chondrogenic spheroids revealed enhanced gadolinium uptake after simultaneous exposure to local anesthetics. Analyses of the spatial gadolinium distribution using synchrotron X-ray-fluorescence scanning indicates gadolinium exposed chondrocytes. In vitro exposure to DOTA-Gd does not alter viability and proliferation of human chondrocytes and the chondrotoxic potential of the anesthetics. Reduced viability induced by ropivacaine was found to be reversible, while exposure to bupivacaine leads to irreversible cell death. Our data suggest that ropivacaine is more tolerable than bupivacaine and that DOTA-Gd exposure does not alter the cytotoxicity of both anesthetics. Enhanced gadolinium uptake into cartilage due to co-administration of anesthetics should find attention.

2.
Adv Sci (Weinh) ; 7(20): 2000412, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33101844

RESUMO

Metallic implants are frequently used in medicine to support and replace degenerated tissues. Implant loosening due to particle exposure remains a major cause for revision arthroplasty. The exact role of metal debris in sterile peri-implant inflammation is controversial, as it remains unclear whether and how metals chemically alter and potentially accumulate behind an insulating peri-implant membrane, in the adjacent bone and bone marrow (BM). An intensively focused and bright synchrotron X-ray beam allows for spatially resolving the multi-elemental composition of peri-implant tissues from patients undergoing revision surgery. In peri-implant BM, particulate cobalt (Co) is exclusively co-localized with chromium (Cr), non-particulate Cr accumulates in the BM matrix. Particles consisting of Co and Cr contain less Co than bulk alloy, which indicates a pronounced dissolution capacity. Particulate titanium (Ti) is abundant in the BM and analyzed Ti nanoparticles predominantly consist of titanium dioxide in the anatase crystal phase. Co and Cr but not Ti integrate into peri-implant bone trabeculae. The characteristic of Cr to accumulate in the intertrabecular matrix and trabecular bone is reproducible in a human 3D in vitro model. This study illustrates the importance of updating the view on long-term consequences of biomaterial usage and reveals toxicokinetics within highly sensitive organs.

3.
Front Immunol ; 10: 2758, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31827473

RESUMO

Delayed type hypersensitivity (DTH) reactions are considered infrequent complications in arthroplasty, but have been recognized to be associated with devastating morbidity and substantial decrease in quality of life of affected patients. Chronic inflammation of artificial joints and associated loss of peri-implant bone often require revision surgery. Methods for the diagnosis of implant-related DTH are available but infrequently considered to the full extent. Sequential diagnostics based on exclusion of septic complications, local and systemic metal level determination, lymphocyte transformation testing (LTT), and local T cell subset analysis are required for an unequivocal DTH diagnosis. Here, we report on a patient with a history of chronic rheumatoid arthritis and an unfavorable outcome of unilateral knee arthroplasty. This case illustrates pitfalls and difficulties in the course of recurrent inflammation following joint replacement. In the early course, suspicion of low-grade bacterial infection led to three two-stage revisions. Afterwards, the joint was proven to be sterile. However, metal level quantification revealed release of especially cobalt and chromium from the joint, LTT indicated persisting cobalt and nickel sensitization and subset analysis of T cells from the synovium suggested DTH as a root cause for the inflammatory symptoms. This report aims to recommend the depicted diagnostic algorithm as an adequate tool for future DTH detection. Yet, systemic to local subset ratios for effector memory and regulatory T cells should be derived from sufficient patient numbers to establish it as a diagnostic marker. Moreover, future prospects regarding implant-related DTH diagnostics are discussed. Therapeutic options for the portrayed patient are proposed, considering pharmaceutical, cell-therapeutic and surgical aspects. Patients who experience peri-implant inflammation but do not have obvious mechanical or infectious problems remain a diagnostic challenge and are at high risk of being treated inadequately. Since potentially sensitizing materials are regularly used in arthroplasty, it is essential to detect cases of acute DTH-derived inflammation of an artificial joint at early postoperative stages. This would reduce the severity of inflammation-related long-term consequences for affected patients and may avoid unnecessary revision surgery.


Assuntos
Artrite Reumatoide/cirurgia , Hipersensibilidade Tardia/diagnóstico , Hipersensibilidade Tardia/imunologia , Metais/imunologia , Idoso , Artrite Reumatoide/imunologia , Artroplastia do Joelho/efeitos adversos , Cromo/efeitos adversos , Cromo/imunologia , Cobalto/efeitos adversos , Cobalto/imunologia , Feminino , Humanos , Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Metais/efeitos adversos , Níquel/efeitos adversos , Níquel/imunologia , Reoperação , Linfócitos T/imunologia