Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Clin Oral Investig ; 15(5): 635-41, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20505963

RESUMO

The aim of this in vitro study was to compare the performance of two laser fluorescence devices (LF, LFpen), conventional visual criteria (VE), ICDAS and radiographic examination on occlusal surfaces of primary teeth. Thirty-seven primary human molars were selected from a pool of extracted teeth, which were stored frozen at -20 °C until use. Teeth were assessed twice by two experienced examiners using laser fluorescence devices (LF and LFpen), conventional visual criteria, ICDAS and bitewing radiographs, with a 2-week interval between measurements. After measurement, the teeth were histologically prepared and assessed for caries extension. The highest sensitivity was observed for ICDAS at D(1) and D(3) thresholds, with no statistically significant difference when compared to the LF devices, except at the D(3) threshold. Bitewing radiographs presented the lowest values of sensitivity. Specificity at D(1) was higher for LFpen (0.90) and for VE at D(3) (0.94). When VE was combined with LFpen the post-test probabilities were the highest (94.0% and 89.2% at D(1) and D(3) thresholds, respectively). High values were observed for the combination of ICDAS and LFpen (92.0% and 80.0%, respectively). LF and LFpen showed the highest values of ICC for interexaminer reproducibility. However, regarding ICDAS, BW and VE, intraexaminer reproducibility was not the same for the two examiners. After primary visual inspection using ICDAS or not, the use of LFpen may aid in the detection of occlusal caries in primary teeth. Bitewing radiographs may be indicated only for approximal caries detection.


Assuntos
Cárie Dentária/diagnóstico , Lasers , Dente Molar/patologia , Exame Físico , Radiografia Interproximal , Dente Decíduo/patologia , Área Sob a Curva , Cárie Dentária/diagnóstico por imagem , Esmalte Dentário/diagnóstico por imagem , Esmalte Dentário/patologia , Dentina/diagnóstico por imagem , Dentina/patologia , Fluorescência , Humanos , Dente Molar/diagnóstico por imagem , Variações Dependentes do Observador , Exame Físico/normas , Valor Preditivo dos Testes , Curva ROC , Radiografia Interproximal/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dente Decíduo/diagnóstico por imagem
2.
Clin Oral Investig ; 14(6): 707-11, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19655179

RESUMO

The aim of this in vitro study was to evaluate the relationship between laser fluorescence values and sealant penetration depth on occlusal fissures. One hundred and sixty-six permanent molars were selected and divided into four groups, which were each treated using a different sealant (two clear and two opaque). The teeth were independently measured twice by two experienced dentists using two laser fluorescence devices-DIAGNOdent (LF and LFpen)-before and after sealing, and then thermoclycled. After measuring, the teeth were histologically prepared and assessed for caries extension. Digital photographs of the cut sealed sites were assessed, and the sealant penetration depth was measured. All 166 sites were measured by one of the examiners taking as limits the outer and inner surface of the sealant into the fissure. For each device (LF and LFpen) and each group, the difference between the values at baseline and after sealing was plotted against the sealant penetration depth and scatter plots were provided. It could be observed that most of the points were concentrated around the zero line, for both LF and LFpen in the four groups. In conclusion, there is no relation between changes in DIAGNOdent values and increasing of depth sealant penetration within the occlusal fissures.


Assuntos
Fissuras Dentárias/diagnóstico , Lasers , Selantes de Fossas e Fissuras/química , Condicionamento Ácido do Dente/métodos , Bis-Fenol A-Glicidil Metacrilato/química , Resinas Compostas/química , Cárie Dentária/patologia , Esmalte Dentário/patologia , Fissuras Dentárias/patologia , Fissuras Dentárias/terapia , Progressão da Doença , Fluorescência , Humanos , Processamento de Imagem Assistida por Computador , Nanoestruturas/química , Fotografia Dentária , Selantes de Fossas e Fissuras/uso terapêutico , Propriedades de Superfície , Temperatura , Fatores de Tempo , Gravação em Vídeo
3.
Oper Dent ; 35(5): 564-71, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20945748

RESUMO

This study evaluated the performance of the DIAGNOdent pen laser fluorescence device (LFpen) in comparison with visual examination (VE), bitewing radiographs (BW) and visual examination combined with bitewing radiographs (VEBW) in detecting secondary approximal caries associated with composite restorations. In total, 60 approximal surfaces from 43 permanent molars with composite restorations were assessed twice by two examiners using the LFpen, VE, BW and VEBW. After histological preparation and hardness measurements, the sample was assigned to either a crown or root caries group, depending on the location of the lesions as the gold standard. For crown caries at D1, the highest values of specificity and sensitivity were observed for the LFpen at a cutoff value of 18 (1.00) and for the VEBW (0.89). At D3 (cutoff of 30), the LFpen showed the highest values of sensitivity and specificity. For root caries, the LFpen and VEBW showed the highest values of specificity (0.54), sensitivity (0.81) and accuracy (0.69). The Spearman rank correlation coefficients for crown/root caries with histology were 0.54/0.37 (LFpen), 0.29/0.10 (BW), 0.29/0.18 (VE) and 0.23/0.37 (VEBW). For the LFpen, the ICC varied from 0.80 (interexaminer) to 0.97 (intraexaminer B); the kappa value was 0.19 for BW and 0.35 for VE (interexaminer). Intraexaminer kappa values for BW were 0.25 (A) and 0.29 (B), and those for VE were 0.31 (A) and 0.32 (B). The LFpen device exhibited a performance comparable to that of conventional methods but with higher interexaminer reproducibility. Therefore, the LFpen should be considered an auxiliary method for the detection of secondary approximal caries associated with composite restorations.


Assuntos
Resinas Compostas , Cárie Dentária/diagnóstico , Materiais Dentários , Restauração Dentária Permanente , Lasers , Resinas Compostas/química , Cárie Dentária/diagnóstico por imagem , Cárie Dentária/patologia , Materiais Dentários/química , Fluorescência , Dureza , Humanos , Lasers/normas , Variações Dependentes do Observador , Radiografia Interproximal , Recidiva , Reprodutibilidade dos Testes , Cárie Radicular/diagnóstico , Cárie Radicular/diagnóstico por imagem , Cárie Radicular/patologia , Sensibilidade e Especificidade , Coroa do Dente/diagnóstico por imagem , Coroa do Dente/patologia , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/patologia , Percepção Visual/fisiologia
4.
Lasers Med Sci ; 24(3): 301-6, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-18309456

RESUMO

The aim of this study was to assess the influence of the zero value subtraction on the performance of laser fluorescence (LFpen) for approximal caries detection. Three areas (cuspal, middle and cervical) of both mesial and distal buccal surfaces of 78 permanent molars were assessed using both wedge-shaped (WDG) and tapered wedge-shaped (TWDG) tips. With the addition of the average, one cut-off value for each area was obtained and the performance was assessed. The areas under the receiver operating characteristics (ROC) curve, specificity, sensitivity and accuracy with and without the zero value subtraction were calculated. The McNemar test revealed a statistically significant difference for specificity at thresholds D(1), D(2) and D(3) (WDG) and D(1) and D(2) (TWDG) when the zero value subtraction was not performed. Influence of the zero value subtraction on the LFpen performance was observed for approximal caries detection. However, when modified cut-off values were used, the zero value subtraction could be eliminated.


Assuntos
Cárie Dentária/diagnóstico , Lasers , Instrumentos Odontológicos , Fluorescência , Humanos , Técnicas In Vitro , Dente Molar/patologia , Curva ROC , Sensibilidade e Especificidade
5.
J Am Dent Assoc ; 139(8): 1105-12, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18682625

RESUMO

BACKGROUND: The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. METHODS: The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. RESULTS: The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. CONCLUSIONS: For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. CLINICAL IMPLICATIONS: When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.


Assuntos
Cárie Dentária/diagnóstico , Lasers , Área Sob a Curva , Calibragem , Cárie Dentária/patologia , Esmalte Dentário/patologia , Dentina/patologia , Desenho de Equipamento , Fluorescência , Corantes Fluorescentes , Humanos , Lasers/normas , Teste de Materiais , Fotografia Dentária , Valor Preditivo dos Testes , Curva ROC , Rodaminas , Sensibilidade e Especificidade , Coroa do Dente/patologia
6.
J Dent Educ ; 77(8): 1086-91, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23929579

RESUMO

This study aimed to evaluate the effect of an e-learning program on the validity and reproducibility of the International Caries Detection and Assessment System (ICDAS) in detecting occlusal caries. For the study, 170 permanent molars were selected. Four dentists in Switzerland who had no previous contact with ICDAS examined the teeth before and after the e-learning program and scored the sites according to ICDAS. Teeth were histologically prepared and assessed for caries extension. The significance level was set at 0.05. Sensitivity before and after the e-learning program was 0.80 and 0.77 (D1), 0.72 and 0.63 (D2), and 0.74 and 0.67 (D3,4), respectively. Specificity was 0.64 and 0.69 (D1), 0.70 and 0.81 (D2), and 0.81 and 0.87 (D3,4). A McNemar test did not show any difference between the values of sensitivity, specificity, accuracy, and area under the ROC curve (AUC) before and after the e-learning program. The averages of wK values for interexaminer reproducibility were 0.61 (before) and 0.66 (after). Correlation with histology presented wK values of 0.62 (before) and 0.63 (after). A Wilcoxon test showed a statistically significant difference between before and after the e-learning program. In conclusion, even though ICDAS performed well in detecting occlusal caries, the e-learning program did not have any statistically significant effect on its performance by these experienced dentists.


Assuntos
Competência Clínica , Instrução por Computador , Cárie Dentária/diagnóstico , Odontólogos , Internet , Coroa do Dente/patologia , Área Sob a Curva , Codificação Clínica , Árvores de Decisões , Cárie Dentária/patologia , Esmalte Dentário/patologia , Dentina/patologia , Avaliação Educacional , Humanos , Dente Molar/patologia , Dente Serotino/patologia , Variações Dependentes do Observador , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suíça
7.
Microsc Res Tech ; 75(5): 605-8, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22021193

RESUMO

UNLABELLED: The aim of this in vitro study was to assess the agreement among four techniques used as gold standard for the validation of methods for occlusal caries detection. Sixty-five human permanent molars were selected and one site in each occlusal surface was chosen as the test site. The teeth were cut and prepared according to each technique: stereomicroscopy without coloring (1), dye enhancement with rhodamine B (2) and fuchsine/acetic light green (3), and semi-quantitative microradiography (4). Digital photographs from each prepared tooth were assessed by three examiners for caries extension. Weighted kappa, as well as Friedman's test with multiple comparisons, was performed to compare all techniques and verify statistical significant differences. RESULTS: kappa values varied from 0.62 to 0.78, the latter being found by both dye enhancement methods. Friedman's test showed statistical significant difference (P < 0.001) and multiple comparison identified these differences among all techniques, except between both dye enhancement methods (rhodamine B and fuchsine/acetic light green). Cross-tabulation showed that the stereomicroscopy overscored the lesions. Both dye enhancement methods showed a good agreement, while stereomicroscopy overscored the lesions. Furthermore, the outcome of caries diagnostic tests may be influenced by the validation method applied. Dye enhancement methods seem to be reliable as gold standard methods.


Assuntos
Cárie Dentária/diagnóstico , Cárie Dentária/patologia , Humanos , Microrradiografia/métodos , Microscopia/métodos , Dente Molar/patologia , Coloração e Rotulagem/métodos
8.
J Biomed Opt ; 16(10): 107003, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22029365

RESUMO

The aim of this study was to assess the performance of two light-emitting diode (LED)- and two laser fluorescence-based devices in detecting occlusal caries in vitro. Ninety-seven permanent molars were assessed twice by two examiners using two LED- (Midwest Caries - MID and VistaProof - VP) and two laser fluorescence-based (DIAGNOdent 2095 - LF and DIAGNOdent pen 2190 - LFpen) devices. After measuring, the teeth were histologically prepared and classified according to lesion extension. At D1 the specificities were 0.76 (LF and LFpen), 0.94 (MID), and 0.70 (VP); the sensitivities were 0.70 (LF), 0.62 (LFpen), 0.31 (MID), and 0.75 (VP). At D(3) threshold the specificities were 0.88 (LF), 0.87 (LFpen), 0.90 (MID), and 0.70 (VP); the sensitivities were 0.63 (LF and LFpen), 0.70 (MID), and 0.96 (VP). Spearman's rank correlations with histology were 0.56 (LF), 0.51 (LFpen), 0.55 (MID), and 0.58 (VP). Inter- and intraexaminer ICC values were high and varied from 0.83 to 0.90. Both LF devices seemed to be useful auxiliary tools to the conventional methods, presenting good reproducibility and better accuracy at D(3) threshold. MID was not able to differentiate sound surfaces from enamel caries and VP still needs improvement on the cut-off limits for its use.


Assuntos
Cárie Dentária/diagnóstico , Diagnóstico Bucal/instrumentação , Fluorescência , Humanos , Lasers , Dente Molar/patologia , Dispositivos Ópticos , Fenômenos Ópticos
9.
Photomed Laser Surg ; 27(3): 435-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19416005

RESUMO

OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.


Assuntos
Cárie Dentária/diagnóstico , Instrumentos Odontológicos , Fluorescência , Lasers , Dente Molar , Cloreto de Polivinila , Calibragem , Desenho de Equipamento , Humanos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatísticas não Paramétricas
10.
Community Dent Oral Epidemiol ; 37(5): 399-404, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19681984

RESUMO

OBJECTIVES: The aim of this in vitro study was to assess the inter- and intra-examiner reproducibility and the accuracy of the International Caries Detection and Assessment System-II (ICDAS-II) in detecting occlusal caries. METHODS: One hundred and sixty-three molars were independently assessed twice by two experienced dentists using the 0- to 6-graded ICDAS-II. The teeth were histologically prepared and classified using two different histological systems [Ekstrand et al. (1997) Caries Research vol. 31, pp. 224-231; Lussi et al. (1999) Caries Research vol. 33, pp. 261-266] and assessed for caries extension. Sensitivity, specificity, accuracy and area under the ROC curve (A(z)) were obtained at D(2) and D(3) thresholds. Unweighted kappa coefficient was used to assess inter- and intra-examiner reproducibility. RESULTS: For the Ekstrand et al. histological classification the sensitivity was 0.99 and 1.00, specificity 1.00 and 0.69 and accuracy 0.99 and 0.76 at D(2) and D(3), respectively. For the Lussi et al. histological classification the sensitivity was 0.91 and 0.75, specificity 0.47 and 0.62 and accuracy 0.86 and 0.68 at D(2) and D(3), respectively. The A(z) varied from 0.54 to 0.73. The inter- and intra-examiner kappa values were 0.51 and 0.58, respectively. CONCLUSIONS: ICDAS-II presented good reproducibility and accuracy in detecting occlusal caries, especially caries lesions in the outer half of the enamel.


Assuntos
Testes de Atividade de Cárie Dentária/normas , Cárie Dentária/diagnóstico , Cárie Dentária/classificação , Humanos , Funções Verossimilhança , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto/normas , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA