Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Hazard Mater ; 137(3): 1395-401, 2006 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-16730902

RESUMO

The standard sampling methods for toluene diisocyanate (TDI) only collect total TDI without separating the aerosol and gas phases. There are few other samplers, such as the dual filter, triple filter and annular denuder systems (ADS), which are able to sample the aerosol and gas phases simultaneously. This field study was conducted at two workplaces to access the total 2,4-TDI and the gaseous and aerosol TDI concentrations by different samplers simultaneously. In addition to the standard sampling time of 15 min, sampling was done for 30 and 60 min to study the effect of sampling time on the measured 2,4-TDI concentrations. Test results at two workplaces show that gas-phase 2,4-TDI is the predominant species and the aerosol phase concentration is very small. The measurements using various samplers show that the sampling time influences the sampled TDI concentration considerably which may be due to reaction of TDI with water vapor and polyo in the sampling process. It is evident that as sampling time increases the TDI concentration decreases. Laboratory test was also conducted using pure gas-phase 2,4-TDI to confirm the sampling time effect on the measured concentrations found in the field study.


Assuntos
Tolueno 2,4-Di-Isocianato/análise
2.
Chemosphere ; 52(6): 1079-88, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12781241

RESUMO

Atmospheric lead concentrations were measured randomly, approximately once per week, at five traffic sites in northern Taiwan from September 1994 to May 1995. Three types of theoretical distributions, lognormal, Weibull and gamma were selected to fit the frequency distribution of the measured lead concentration. Four goodness-of-fit criteria were used to judge which theoretical distribution is the most appropriate to represent the frequency distributions of atmospheric lead. The results show that atmospheric lead concentrations in total suspended particulates fit the lognormal distribution reasonably well in northern Taiwan. The intervals of fitted theoretical cumulative frequency distributions (CFDs) can successfully contain the measured data when the population mean is estimated with a 95% confidence interval. In addition, atmospheric lead concentration exceeding a critical concentration is also predicted from the fitted theoretical CFDs.


Assuntos
Poluentes Atmosféricos/análise , Chumbo/análise , Modelos Estatísticos , Intervalos de Confiança , Monitoramento Ambiental , Distribuições Estatísticas , Taiwan
3.
J Air Waste Manag Assoc ; 53(10): 1265-72, 2003 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-14604337

RESUMO

A new triple filter system sampler/model is proposed for the precise and accurate simultaneous sampling and determination of gas- and aerosol-phase 2,4-toluene diisocyanate (TDI). The system consists of two front Teflon filters for sampling aerosol-phase TDI and a final coated glass fiber filter to collect gas-phase TDI. The aerosol-phase TDI is collected on the first Teflon filter, while the second Teflon filter is used to estimate gaseous TDI adsorbed by the first. According to the gas adsorption test of two Teflon filters in series, the TDI gas adsorption fraction of the two filters is almost the same. Results of the evaporation test using pure TDI aerosols collected on the Teflon filter show that significant evaporation of the compound does not occur during sampling. These two findings allow the use of a model to estimate accurate gas- and aerosol-phase TDI concentrations. The comparison test with an annular denuder shows that the triple filter system can minimize the TDI sampling bias between the dual filter and the annular denuder systems.


Assuntos
Monitoramento Ambiental/métodos , Tolueno 2,4-Di-Isocianato/análise , Aerossóis , Filtração , Gases , Sensibilidade e Especificidade , Tolueno 2,4-Di-Isocianato/isolamento & purificação , Local de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA