Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Vasc Med ; 26(5): 515-525, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34009060

RESUMO

Diagnostic criteria to classify severity of internal carotid artery (ICA) stenosis vary across vascular laboratories. Consensus-based criteria, proposed by the Society of Radiologists in Ultrasound in 2003 (SRUCC), have been broadly implemented but have not been adequately validated. We conducted a multicentered, retrospective correlative imaging study of duplex ultrasound versus catheter angiography for evaluation of severity of ICA stenosis. Velocity data were abstracted from bilateral duplex studies performed between 1/1/2009 and 12/31/2015 and studies were interpreted using SRUCC. Percentage ICA stenosis was determined using North American Symptomatic Carotid Endarterectomy Trial (NASCET) methodology. Receiver operating characteristic analysis evaluated the performance of SRUCC parameters compared with angiography. Of 448 ICA sides (from 224 patients), 299 ICA sides (from 167 patients) were included. Agreement between duplex ultrasound and angiography was moderate (κ = 0.42), with overestimation of degree of stenosis for both moderate (50-69%) and severe (⩾ 70%) ICA lesions. The primary SRUCC parameter for ⩾ 50% ICA stenosis of peak-systolic velocity (PSV) of ⩾ 125 cm/sec did not meet prespecified thresholds for adequate sensitivity, specificity, and accuracy (sensitivity 97.8%, specificity 64.2%, accuracy 74.5%). Test performance was improved by raising the PSV threshold to ⩾ 180 cm/sec (sensitivity 93.3%, specificity 81.6%, accuracy 85.2%) or by adding the additional parameter of ICA/common carotid artery (CCA) PSV ratio ⩾ 2.0 (sensitivity 94.3%, specificity 84.3%, accuracy 87.4%). For ⩾ 70% ICA stenosis, analysis was limited by a low number of cases with angiographically severe disease. Interpretation of carotid duplex examinations using SRUCC resulted in significant overestimation of severity of ICA stenosis when compared with angiography; raising the PSV threshold for ⩾ 50% ICA stenosis to ⩾ 180 cm/sec as a single parameter or requiring the ICA/CCA PSV ratio ⩾ 2.0 in addition to PSV of ⩾ 125 cm/sec for laboratories using the SRUCC is recommended to improve the accuracy of carotid duplex examinations.


Assuntos
Artéria Carótida Interna , Estenose das Carótidas , Acreditação , Velocidade do Fluxo Sanguíneo , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Constrição Patológica , Humanos , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Ultrassonografia Doppler Dupla
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA