Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Clin Transplant ; 35(7): e14335, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33948997

RESUMO

Chronic organ shortage remains the most limiting factor in lung transplantation. To overcome this shortage, a minority of centers have started with efforts to reintroduce donation after circulatory death (DCD). This review aims to evaluate the experimental background, the current international clinical experience, and the further potential and challenges of the different DCD categories. Successful strategies have been implemented to reduce the problems of warm ischemic time, thrombosis after circulatory arrest, and difficulties in organ assessment, which come with DCD donation. From the currently reported results, controlled-DCD lungs are an effective and safe method with good mid-term and even long-term survival outcomes comparable to donation after brain death (DBD). Primary graft dysfunction and onset of chronic allograft dysfunction seem also comparable. Thus, controlled-DCD lungs should be ceased to be treated as marginal and instead be promoted as an equivalent alternative to DBD. A wide implementation of controlled-DCD-lung donation would significantly decrease the mortality on the waiting list. Therefore, further efforts in establishment of legislation and logistics are crucial. With regard to uncontrolled DCD, more data are needed analyzing long-term outcomes. To help with the detailed assessment and improvement of uncontrolled or otherwise questionable grafts after retrieval, ex-vivo lung perfusion is promising.


Assuntos
Transplante de Pulmão , Obtenção de Tecidos e Órgãos , Morte Encefálica , Morte , Sobrevivência de Enxerto , Humanos , Pulmão , Estudos Retrospectivos , Doadores de Tecidos
2.
BMC Health Serv Res ; 18(1): 876, 2018 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-30458762

RESUMO

BACKGROUND: Various actions have been taken during the last decade to increase the number of organs from deceased donors available for transplantation in Switzerland. This study provides an overview on key figures of the Swiss deceased organ donation and transplant activity between 2008 and 2017. In addition, it puts the evolution of the Swiss donation program's efficiency in relation to the situation in the neighboring countries. METHODS: This study is an analysis of prospective registry data, covering the period from 1 January 2008 to 31 December 2017. It includes all actual deceased organ donors (ADD) in Switzerland. Donor data were extracted from the Swiss Organ Allocation System. The "donor conversion index" (DCI) methodology and data was used for the comparison of donation program efficiency in Switzerland, Germany, Austria, Italy and France. RESULTS: During the study period there were 1116 ADD in Switzerland. The number of ADD per year increased from 91 in 2008 to 145 in 2017 (+ 59%). The reintroduction of the donation after cardiocirculatory death (DCD) program in 2011 resulted in the growth of annual percentages of DCD donors, reaching a maximum of 27% in 2017. The total number of organs transplanted from ADD was 3763 (3.4 ± 1.5 transplants per donor on average). Of these, 48% were kidneys (n = 1814), 24% livers (n = 903), 12% lungs (n = 445), 9% hearts (n = 352) and 7% pancreata or pancreatic islets (n = 249). The donation program efficiency assessment showed an increase of the Swiss DCI from 1.6% in 2008 to 2.7% in 2017 (+ 69%). The most prominent efficiency growth was observed between 2012 and 2017. Even though Swiss donation efficiency increased during the study period, it remained below the DCI of the French and Austrian donation programs. CONCLUSION: Swiss donation activity and efficiency grew during the last decade. The increased donation efficiency suggests that measures implemented so far were effective. The lower efficiency of the Swiss donation program, compared to the French and Austrian programs, may likely be explained by the lower consent rate in Switzerland. This issue should be addressed in order to achieve the goal of more organs available for transplantation.


Assuntos
Doadores de Tecidos/estatística & dados numéricos , Obtenção de Tecidos e Órgãos/tendências , Áustria , Morte Encefálica , Eficiência Organizacional , Feminino , Previsões , França , Alemanha , Parada Cardíaca , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Sistema de Registros , Suíça
3.
Swiss Med Wkly ; 152: w30139, 2022 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-35201682

RESUMO

AIMS OF THE STUDY: Organ donation after circulatory death (DCD) was reintroduced in Switzerland in 2011 and accounts for a third of deceased organ donors today. Controversy persists if DCD transplants are of similar quality to transplants following donation after brain death (DBD), mainly due to warm ischaemia time DCD organs are exposed to. We compared DCD with DBD in Switzerland. METHODS: Data on deceased adults who were referred to and approved for organ donation from 1 September 2011 to 31 December 2019 were retrospectively analysed (217 DCD, 840 DBD donors). We compared DCD and DBD donor/organ characteristics, transplant rates of lungs, liver, kidneys, and pancreas, and early liver and kidney graft function in the recipient. The effect of DCD/DBD on transplant rates (organ transplanted or not) and 72-hour recipient graft function (moderate/good vs delayed graft function / organ loss) was analysed using multivariable logistic regression. Among utilised DCD donors, we analysed the effect of functional warm ischaemia time (FWIT) and donor age on 72-hour post-transplant liver and kidney graft function, also using multivariable logistic regression. RESULTS: DCD donors were more often male (64.5% vs 56.8% p = 0.039), presented with heart disease (36.4% vs 25.5%, p <0.001), were resuscitated before hospital admission (41.9% vs 30.7%, p = 0.006), and died from anoxia (41.9% vs 23.9%). Kidney function before transplantation was comparable, lung, liver and pancreas function were poorer in DCD than DBD. Eighty-one and 91% of approved DCD and DBD donors were utilised (p <0.001). Median FWIT in DCD was 29 minutes (interquartile range 25-35). DCD transplant rates ranged from 4% (pancreas) to 73% (left kidney) and were all lower compared with DBD. Seventy-two-hour liver graft function was comparable between DCD and DBD (94.2% vs 96.6% moderate/good, p = 0.199). DCD kidney transplants showed increased risk of delayed graft function or early organ loss (odds ratios 8.32 and 5.05; 95% confidence intervals CI 5.28-13.28 and 3.22-7.95; both p <0.001, for left and right kidney transplants, respectively). No negative effect of prolonged FWIT or higher donor age was detected. CONCLUSION: Despite less favourable donor/organ characteristics compared with donation after brain death, donation after circulatory death donors are increasingly referred and today provide an important source for scarce transplants in Switzerland. We identified a higher risk for delayed graft function or early organ loss for DCD kidney transplants, but not for DCD liver transplants. When carefully selected and allowed for other risk factors in organ allocation, prolonged functional warm ischaemia time or higher age in donation after circulatory death does not seem to be associated with impaired graft function early after transplantation.


Assuntos
Morte Encefálica , Obtenção de Tecidos e Órgãos , Adulto , Idoso , Morte , Sobrevivência de Enxerto , Humanos , Masculino , Estudos Retrospectivos , Suíça , Doadores de Tecidos
4.
Ther Umsch ; 68(12): 673-7, 2011 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-22139981

RESUMO

The present article will give a related overview of the current background of the field of donor recruitment and transplantation medicine. The transplantation Law that came into effect on the 01.07.2007 has caused numerous changes in the identification and reporting of potential organ- and tissue donors in hospitals with accredited Intensive care units. The law has had a great influence on the allocation practice of the rare organs in Switzerland. With just 12.6 cadaveric donors per million inhabitants, Switzerland is, compared to other European countries at the bottom of the table. This is not without influence on the waiting list, which at the end of 2010 was at a new all time high with 1029 patients. We assume that almost half of the Swiss population has not yet decided if they want to donate their organs or not. The most important contact people in this subject are the practicing colleagues, by this we mean you. On a specially publicized Link [www.swisstransplant.org/medizinerinfo] you will find more information and documents that you can either put out in your practice or download them for further education. Organ donation is possible until a high age, bring this subject up with your patients, and inform them transparently and openly about this. Ask your patients to inform their loved ones of their decision for or against organ donation.


Assuntos
Programas Nacionais de Saúde/legislação & jurisprudência , Transplante de Órgãos/legislação & jurisprudência , Obtenção de Tecidos e Órgãos/legislação & jurisprudência , Medicina Geral , Humanos , Suíça , Doadores de Tecidos/legislação & jurisprudência , Doadores de Tecidos/provisão & distribuição , Listas de Espera
5.
Vasa ; 39(3): 219-28, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20737380

RESUMO

BACKGROUND: Conservative management of acute type B aortic dissection is currently being challenged by primary thoracic endovascular aortic repair. Aim was to assess outcome and quality of life after these different approaches using an adjusted standard population as benchmark. PATIENTS AND METHODS: Observational study of a prospectively collected (January 2000 to December 2005) consecutive series of 87 patients with acute type B aortic dissection. Patients were 63 +/- 13 years old and 68 were men (78.2 %). Seventy-two were managed conservatively (83 %) and 15 invasively (12 by endovascular aortic repair). Follow-up was 36 +/- 19 months. Endpoints were early and late morbidity and mortality, and long-term quality of life as assessed by the Short Form health survey questionnaire. RESULTS: Patient cohorts were similar regarding age, risk profile and local disease. In the conservative cohort, four patients died during early (5.6 %) and eight during long-term follow-up (cumulative four years survival rate 79 %). Thirty-two patients needed secondary surgical management (44 %), i.e. delayed aortic repair (n = 11), or interventions on adjacent aortic sections or major branches (n = 21). In the surgical cohort no patient died, and no repeated interventions were necessary after the peri-operative period. Long-term quality of life scores were 100 (69-115) in conservatively and 94 (75-124) in invasively managed patients. Normal scores range from 85 to 115. CONCLUSIONS: Primary endovascular management of uncomplicated acute type B dissection is safe and leads to excellent long-term results, whereas secondary interventions were required with high incidence after initial conservative management. Long-term quality of life, however, returned to normal with any successful treatment strategy.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Qualidade de Vida , Doença Aguda , Idoso , Dissecção Aórtica/mortalidade , Dissecção Aórtica/psicologia , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/psicologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Implante de Prótese Vascular/psicologia , Bases de Dados como Assunto , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Avaliação de Processos e Resultados em Cuidados de Saúde , Reoperação , Medição de Risco , Fatores de Risco , Inquéritos e Questionários , Suíça , Fatores de Tempo , Resultado do Tratamento
6.
J Heart Valve Dis ; 18(4): 380-5, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19852141

RESUMO

BACKGROUND AND AIM OF THE STUDY: Combined replacement of the aortic valve and ascending aorta using a composite graft represents the standard treatment for dilated aortic root with concomitant structural damage of the aortic valve, especially when the aortic valve cannot be preserved. Unfortunately, hemodynamic changes associated with prosthetic replacement of the aortic root have not been fully elucidated. The study aim was to compare hemodynamics within the replaced aortic root using either a prosthetic vascular graft with bulges mimicking the sinuses of Valsalva and including a stented pericardial valve, or a straight xenopericardial conduit and a stentless porcine valve. METHODS: Between July 2004 and March 2006, a total of 35 patients (mean age 65.2 years: range: 32-80 years) was enrolled into the present study. Aortic root replacement was performed in nine patients with a Valsalva graft (Gelweave Valsalva; Vascutek, Renfrewshire, UK) including a stented pericardial valve, and in 19 patients with a xenopericardial conduit containing a stentless porcine valve. All patients underwent postoperative magnetic resonance imaging (MRI). A control group of seven patients allowed for comparison with native aortic root hemodynamics. RESULTS: Maximum flow-velocity above the aortic valve as one marker of compliance of the aortic root was slightly higher in patients with a Valsalva graft compared to native aortic roots (1.9 m/s versus 1.3 m/s, p = 0.001), but was significantly lower than in patients with the xenopericardial graft without neo-sinuses (1.3 m/s versus 2.4 m/s, p < 0.001). CONCLUSION: The pre-shaped bulges in the prosthetic Valsalva graft effectively mimic the native sinuses of Valsalva, improve compliance of the aortic root, and result in a more physiologic flow pattern, as demonstrated by postoperative MRI.


Assuntos
Aorta/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Implante de Prótese Vascular , Implante de Prótese de Valva Cardíaca , Seio Aórtico/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Técnicas de Sutura
7.
PLoS One ; 14(2): e0211614, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30735508

RESUMO

This study investigated the critical care staff's attitude, knowledge and involvement with donation, skills and confidence with donation-related tasks and their association with consent rates at the hospital level. In 2015, we conducted a cross-sectional survey among critical care staff of hospitals involved in organ donation using an anonymous online questionnaire with a response rate of 56.4% (n = 2799). The hospital level consent rate was obtained from the Swiss Monitoring of Potential Donors database (2013-2015). For each hospital, we calculated a mean score for each predictor of interest of the Hospital Attitude Survey and investigated the association with hospital consent rates with generalized linear mixed-effect models. In univariable analysis, one score point increase in doctors' confidence resulted in a 66% (95% CI: 45%-80%) reduction in the odds to consent, and one score point increase in nurses' attitudes resulted in a 223% (95% CI: 84%-472%) increase in the odds to consent. After simultaneously adjusting for all major predictors found in the crude models, only levels of education of medical and nursing staff remained as significant predictors for hospital consent rates. In Switzerland, efforts are needed to increase consent rates for organ donation and should concentrate on continuous support as well as specific training of the hospital staff involved in the donation process.


Assuntos
Cuidados Críticos/estatística & dados numéricos , Conhecimentos, Atitudes e Prática em Saúde , Hospitais/estatística & dados numéricos , Consentimento Livre e Esclarecido/estatística & dados numéricos , Obtenção de Tecidos e Órgãos/estatística & dados numéricos , Atitude do Pessoal de Saúde , Estudos Transversais , Feminino , Humanos , Conhecimento , Masculino , Recursos Humanos de Enfermagem Hospitalar/estatística & dados numéricos , Transplante de Órgãos/estatística & dados numéricos , Médicos , Inquéritos e Questionários , Suíça , Doadores de Tecidos/estatística & dados numéricos
8.
J Heart Valve Dis ; 17(1): 94-7; discussion 97, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18365575

RESUMO

BACKGROUND AND AIM OF THE STUDY: Preservation of the aortic valve during the repair of acute type A aortic dissection (AADA) is a viable option to prevent lifelong oral anticoagulation. The study aim was to assess aortic valve function following resuspension and supracoronary ascending aortic grafting. METHODS: Among a collective of 210 consecutive patients undergoing surgery for AADA, 140 (66.7%) with resuspension of the aortic valve and supracoronary ascending graft were analyzed. Of these patients, 83 (59.3%) had a complete follow up (mean 61.2 +/- 40.8 months), with 65 of the subgroup (78.3%) being followed by computed tomography scanning and echocardiography. RESULTS: Reoperation due to severe aortic valve regurgitation was required in seven patients (10.8%). The perioperative characteristics were similar in these patients; notably, no significant difference was evident with regards to the aortic annulus diameter and the severity of regurgitation at the time of surgery. The left ventricular mass index was significantly higher in patients requiring reoperation due to aortic valve regurgitation (219.3 +/- 146.6 versus 123.9 +/- 146.6 g/m2; p <0.05). None of the patients died as a result of reoperation. CONCLUSION: The long-term functional results following resuspension of the aortic valve in AADA were very good. A close echocardiographic follow up was necessary, as reoperation of the aortic valve was required in more than 10% of the collective, with an average follow up of five years. Reoperation was mainly related to secondary dilatation of the aortic root.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Doença Aguda , Dissecção Aórtica/diagnóstico , Aneurisma da Aorta Torácica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ecocardiografia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Eur J Cardiothorac Surg ; 33(6): 1025-9, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18343679

RESUMO

BACKGROUND: Transient neurological dysfunction (TND) consists of postoperative confusion, delirium and agitation. It is underestimated after surgery on the thoracic aorta and its influence on long-term quality of life (QoL) has not yet been studied. This study aimed to assess the influence of TND on short- and long-term outcome following surgery of the ascending aorta and proximal arch. METHODS: Nine hundred and seven patients undergoing surgery of the ascending aorta and the proximal aortic arch at our institution were included. Two hundred and ninety patients (31.9%) underwent surgery because of acute aortic dissection type A (AADA) and 617 patients because of aortic aneurysm. In 547 patients (60.3%) the distal anastomosis was performed using deep hypothermic circulatory arrest (DHCA). TND was defined as a Glasgow coma scale (GCS) value <13. All surviving patients had a clinical follow up and QoL was assessed with an SF-36 questionnaire. RESULTS: Overall in-hospital mortality was 8.3%. TND occurred in 89 patients (9.8%). As compared to patients without TND, those who suffered from TND were older (66.4 vs 59.9 years, p<0.01) underwent more frequently emergent procedures (53% vs 32%, p<0.05) and surgery under DHCA (84.3% vs 57.7%, p<0.05). However, duration of DHCA and extent of surgery did not influence the incidence of TND. In-hospital mortality in the group of patients with TND compared to the group without TND was similar (12.0% vs 11.4%; p=ns). Patients with TND suffered more frequently from coronary artery disease (28% vs 20.8%, p=ns) and were more frequently admitted in a compromised haemodynamic condition (23.6% vs 9.9%, p<0.05). Postoperative course revealed more pulmonary complications such as prolonged mechanical ventilation. Additional to their transient neurological dysfunction, significantly more patients had strokes with permanent neurological loss of function (14.6% vs 4.8%, p<0.05) compared to the patients without TND. ICU and hospital stay were significantly prolonged in TND patients (18+/-13 days vs 12+/-7 days, p<0.05). Over a mean follow-up interval of 27+/-14 months, patients with TND showed a significantly impaired QoL. CONCLUSION: The neurological outcome following surgery of the ascending aorta and proximal aortic arch is of paramount importance. The impact of TND on short- and long-term outcome is underestimated and negatively affects the short- and long-term outcome.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Doenças do Sistema Nervoso/etiologia , Complicações Pós-Operatórias , Qualidade de Vida , Adulto , Idoso , Confusão/etiologia , Métodos Epidemiológicos , Feminino , Escala de Coma de Glasgow , Humanos , Hipotermia Induzida , Masculino , Pessoa de Meia-Idade , Prognóstico , Agitação Psicomotora/etiologia , Resultado do Tratamento
10.
Eur J Cardiothorac Surg ; 33(2): 222-4, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18083039

RESUMO

BACKGROUND: Increasing age and comorbidities among patients undergoing coronary artery bypass surgery (CABG) stimulates the exhaustive research for alternative grafts. No-React treatment should render the tissue resistant against degeneration and reduce early inflammatory response. The aim of the present study was an invasive assessment of the patency of No-React bovine internal mammary artery (NRIMA grafts) used as bypass conduit in CABG surgery. PATIENTS AND METHODS: Nineteen NRIMA grafts were used in 17 patients (2.9%) out of a total of 572 patients undergoing CABG surgery within a 12-month period. All intraoperative data were assessed and in-hospital outcome was analysed. Follow-up examination was performed 7.0+/-4.0 months after initial surgery, including clinical status and coronary angiography to assess patency of the NRIMA grafts. RESULTS: Average perioperative flow of all NRIMA grafts was 71+/-60 ml/min. One patient died in hospital due to a multi-organ failure. Four patients refused invasive assessment. Follow-up was complete in 12 patients with overall 13 NRIMA grafts. Nine NRIMA grafts (69.2%) were used for the right coronary system, two NRIMA grafts (15.4%) on the LAD and two on the circumflex artery. Graft patency was 23.1% and was independent of the intraoperative flow measurement. CONCLUSIONS: NRIMA grafts show a very low patency and cannot be recommended as coronary bypass graft conduits. Patency was independent of the perioperative flow, assessed by Doppler ultrasound. Because of this unsatisfying observation, this type of graft should be utilised as a last resource conduit and used only to revascularise less important target vessels, such as the end branches of the right coronary artery.


Assuntos
Bioprótese/normas , Prótese Vascular/normas , Artéria Torácica Interna/transplante , Transplante Heterólogo/normas , Idoso , Animais , Prótese Vascular/efeitos adversos , Bovinos , Angiografia Coronária , Circulação Coronária , Feminino , Seguimentos , Humanos , Anastomose de Artéria Torácica Interna-Coronária/normas , Masculino , Resultado do Tratamento , Grau de Desobstrução Vascular
11.
Heart Surg Forum ; 11(1): E9-12, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18270146

RESUMO

Aprotinin is widely used in cardiac surgery to reduce postoperative bleeding and the need for blood transfusion. Controversy exists regarding the influence of aprotinin on renal function and its effect on the incidence of perioperative myocardial infarction (MI) and cerebrovascular incidents (CVI). In the present study, we analyzed the incidence of these adverse events in patients who underwent coronary artery bypass grafting (CABG) surgery under full-dose aprotinin and compared the data with those recently reported by Mangano et al [2006]. For 751 consecutive patients undergoing CABG surgery under full-dose aprotinin (>4 million kalikrein-inhibitor units) we analyzed in-hospital data on renal dysfunction or failure, MI (defined as creatine kinase-myocardial band > 60 iU/L), and CVI (defined as persistent or transient neurological symptoms and/or positive computed tomographic scan). Average age was 67.0 +/- 9.9 years, and patient pre- and perioperative characteristics were similar to those in the Society of Thoracic Surgeons database. The mortality (2.8%) and incidence of renal failure (5.2%) ranged within the reported results. The incidence rates of MI (8% versus 16%; P < .01) and CVI (2% versus 6%; P < .01) however, were significantly lower than those reported by Mangano et al. Thus the data of our single center experience do not confirm the recently reported negative effect of full-dose aprotinin on the incidence of MI and CVI. Therefore, aprotinin may still remain a valid option to reduce postoperative bleeding, especially because of the increased use of aggressive fibrinolytic therapy following percutaneous transluminal coronary angioplasty.


Assuntos
Aprotinina/farmacologia , Hemorragia Pós-Operatória/prevenção & controle , Inibidores de Serina Proteinase/farmacologia , Idoso , Transfusão de Sangue , Feminino , Indicadores Básicos de Saúde , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos
12.
Transplantation ; 102(10): 1768-1778, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29677069

RESUMO

BACKGROUND: The donation rate (DR) per million population is not ideal for an efficiency comparison of national deceased organ donation programs. The DR does not account for variabilities in the potential for deceased donation which mainly depends on fatalities from causes leading to brain death. In this study, the donation activity was put into relation to the mortality from selected causes. Based on that metric, this study assesses the efficiency of different donation programs. METHODS: This is a retrospective analysis of 2001 to 2015 deceased organ donation and mortality registry data. Included are 27 Council of Europe countries, as well as the United States. A donor conversion index (DCI) was calculated for assessing donation program efficiency over time and in international comparisons. RESULTS: According to the DCI and of the countries included in the study, Spain, France, and the United States had the most efficient donation programs in 2015. Even though mortality from the selected causes decreased in most countries during the study period, differences in international comparisons persist. This indicates that the potential for deceased organ donation and its conversion into actual donation is far from being similar internationally. CONCLUSIONS: Compared with the DR, the DCI takes into account the potential for deceased organ donation, and therefore is a more accurate metric of performance. National donation programs could optimize performance by identifying the areas where most potential is lost, and by implementing measures to tackle these issues.


Assuntos
Comparação Transcultural , Eficiência Organizacional , Transplante de Órgãos/estatística & dados numéricos , Doadores de Tecidos/estatística & dados numéricos , Obtenção de Tecidos e Órgãos/estatística & dados numéricos , Causas de Morte , Europa (Continente)/epidemiologia , Humanos , Sistema de Registros/estatística & dados numéricos , Estudos Retrospectivos , Obtenção de Tecidos e Órgãos/organização & administração , Estados Unidos/epidemiologia
13.
Swiss Med Wkly ; 148: w14614, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29689119

RESUMO

AIM: Various scoring systems aim to assess the quality of organs donated for transplantation on the basis of patient characteristics, clinical examination and laboratory results. How well such scoring systems reflect the practice in lung transplantation in Switzerland has never been studied. Therefore, we evaluated two scoring systems for their ability to predict whether or not donor lungs are accepted by the two Swiss lung transplant centres. METHODS: We retrospectively analysed patient data of adult deceased organ donors in Switzerland between 1 July 2007 and 30 June 2014. Included were all donors from whom at least one organ was transplanted. We evaluated two lung donor quality scores, the multicentre-developed Eurotransplant donor score (EDS), and the single-centre-developed Zurich donor score (ZDS). Both scores were slightly adapted to be applicable to Swiss deceased organ donor data. We evaluated whether these scores can predict whether lungs were transplanted or refused by Swiss transplant centres, using univariate logistic regression. We further assessed their discriminative power by calculating the area under the receiver operating characteristic curve (AUC). RESULTS: Of the 635 donors included in our analysis, 295 (46%) were accepted as lung donors by one of the two lung transplant centres in Switzerland. Our analysis showed that both scores can predict whether or not a donor lung is likely to be accepted for transplantation in Switzerland. As the score value of a donor increases, the odds of the lung being transplanted significantly decreases (odds ratio [OR] 0.58, 95% confidence interval [CI] 0.51-0.65 for the adapted EDS; OR 0.35, 95% CI 0.28-0.43 for the adapted ZDS). This effect is slightly more pronounced in the adapted ZDS than in the adapted EDS. The discriminatory power of the scores from the AUC was 0.719 (95% CI 0.680-0.758) for the adapted EDS, and 0.723 (95% CI 0.681-0.760) for the adapted ZDS, which for both was deemed fair discrimination. CONCLUSIONS: Both scoring systems are able to predict whether or not donor lungs are accepted by the two Swiss lung transplant centres. As an alternative to adapting an established scoring system, a national lung quality score could be derived de novo. This could be based on a logistic regression analysis including the most relevant donor characteristics. However, such a new score would need to be validated on an independent sample and ideally tested for its predictive value in terms of post-transplantation outcome.


Assuntos
Algoritmos , Seleção do Doador/normas , Transplante de Pulmão , Obtenção de Tecidos e Órgãos/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Alocação de Recursos/normas , Estudos Retrospectivos , Fatores de Risco , Suíça , Resultado do Tratamento
14.
Heart Surg Forum ; 10(3): E235-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17599899

RESUMO

OBJECTIVE: The standard heart-lung machine is a major trigger of systemic inflammatory response and the morbidity attributed to conventional extracorporeal circulation (CECC) is still significant. Reduction of blood-artificial surface contact and reduction of priming volume are principal aims in minimized extracorporeal circulation (MECC) cardiopulmonary bypass systems. The aim of this paper is to give an overview of the literature and to present our experience with the MECC-smart suction system. METHODS AND RESULTS: At our institution, 1799 patients underwent isolated coronary artery bypass grafting (CABG) surgery, 1372 with a MECC-smart suction system and 427 with CECC. All in-hospital data were assessed and the results were compared between the 2 groups. Patient characteristics and the distribution of EuroSCORE risk profile in our collective were similar between both groups. Average age in the MECC collective was 67.5 +/- 11.4 years and average EuroSCORE was 5.0 +/- 1.5. Average number of distal anastomoses was similar to the average number encountered in patients undergoing CABG surgery with CECC (3.3 +/- 1.0 for MECC versus 3.2 +/- 1.1 for CECC; P = ns). Myocardial protection is superior in MECC patients with lower postoperative maximal cTnI values (11.0 +/- 10.8 micromol/L for MECC versus 24.7 +/- 25.3 micromol/L for CECC; P < .05). Postoperative recovery was faster in patients operated on with the MECC-smart suction system and discharge from the hospital was earlier than for CECC patients (7.4 +/- 1.9 days for MECC versus 8.8 +/- 3.8 days for CECC; P < .05). CONCLUSIONS: The MECC-smart suction system is a safe perfusion technique for CABG surgery. In patients operated on with this system, the clinical outcome seems to be better than in patients operated on with CECC. This promising and less damaging perfusion technology has the potential to replace CECC systems in CABG surgery.


Assuntos
Ponte Cardiopulmonar/métodos , Ponte de Artéria Coronária , Sucção/instrumentação , Idoso , Ponte Cardiopulmonar/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
15.
Swiss Med Wkly ; 147: w14401, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28165540

RESUMO

BACKGROUND: Organs donated for transplantation remain a scarce resource in Switzerland. One of the reasons for this situation is the high percentage of patients or families who refuse to consent to donation. This study aimed to provide an overview of attitudes towards organ donation among Swiss residents, including any intention to donate organs after death, and whether they had already declared their wish and/or communicated it to anyone. METHODS: A representative poll investigating the attitude of the Swiss population towards deceased organ donation was conducted between 16 and 28 March 2015. Survey data were collected in 1000 structured telephone interviews. Participants consisted of residents aged 15 years and over from all Swiss regions, and covering the German, French and Italian language areas. RESULTS: Of the 1000 survey participants, 92% stated that they have a very positive (58%) or quite positive (33%) attitude towards organ donation, while 6% have a very negative (2%) or quite negative (4%) view. Some 81% of respondents said that they would be willing to donate their organs after death, and 9% expressed a wish not to become a donor. A total of 53% of participants said that they had already communicated or documented whether they wish to donate. CONCLUSION: Our study highlights the importance of continuing to raise awareness about the importance of communicating wishes, both in written form and to family members, and suggests that more work is needed to reap the benefits of the substantial support for organ donation among the Swiss population.


Assuntos
Conhecimentos, Atitudes e Prática em Saúde , Intenção , Doadores de Tecidos/psicologia , Obtenção de Tecidos e Órgãos , Adolescente , Adulto , Comunicação , Família , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Suíça
16.
Circulation ; 112(9 Suppl): I249-52, 2005 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-16159825

RESUMO

BACKGROUND: Since 1994 patients with acute aortic dissection type A (AADA) are followed-up in our outpatient clinic. Early diagnosis of secondary dilatation of the diseased aorta is crucial to reduce late mortality in these patients. Aim of the present study is to asses the impact of a large volume in the false lumen of the diseased downstream aorta on secondary dilatation. METHODS AND RESULTS: 134 patients of 264 patients who underwent surgery for AADA (between January 1994 and June 2003) are followed-up at our outpatient clinic since 1994. 84 patients (62.7%) fulfilled the inclusion criteria. Areas of the true and the false lumens of the aorta were analyzed and a logistic regression was calculated at 5 levels of the aorta for each patient. Patients were divided in 3 groups: group 1 included 34 patients (40.5%) without progression, group 2 had 34 patients (40.5%) with slight progression, and group 3 had 16 patients (19.0%) with important progression, requiring surgery in all patients. In 87.5% of the patients the area of the original lumen was <0% in group 3, compared with 11.8% in group 2 and 8.8% in group 1 in relation to the total area of the aorta 6 months after surgery (P<0.001). CONCLUSIONS: A large false lumen, with an area of the true lumen <30% 6 months after surgery, is the strongest predictor for secondary dilatation of the diseased downstream aorta.


Assuntos
Aneurisma Aórtico/patologia , Dissecção Aórtica/patologia , Doença Aguda , Adulto , Idoso , Dissecção Aórtica/classificação , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Antropometria , Aneurisma Aórtico/classificação , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Aortografia , Progressão da Doença , Feminino , Seguimentos , Humanos , Modelos Logísticos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Recidiva , Fatores de Risco , Suíça , Tomografia Computadorizada por Raios X
17.
Circulation ; 110(11 Suppl 1): II250-5, 2004 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-15364871

RESUMO

BACKGROUND: We have recently demonstrated that the use of deep hypothermic circulatory arrest (DHCA) during surgery for acute type A aortic dissections or thoracic aortic aneurysms adversely affect mid-term quality of life (QoL). The aim of this study is to assess the impact of DHCA duration and the potential effects of antegrade cerebral perfusion (ACP) on mid-term QoL. METHODS AND RESULTS: Between January 1994 and December 2002, 363 patients underwent surgery of the thoracic aorta with the use of DHCA at our institution. One hundred seventy-six (48.5%) presented with acute type A dissections and 187 (51.5%) presented with aortic aneurysms. ACP was used in 41 (11.3%) cases. All in-hospital data were assessed and a follow-up was performed in all survivors after 2.4+/-1.2 years. QoL was analyzed with the Short-Form 36 Health Survey Questionnaire (SF-36). In-hospital mortality was 8.6%. In comparison with patients having undergone DHCA <20 minutes, averaged QoL score was significantly decreased in patients with DHCA between 20 and 34 minutes (95.6+/-12.8 versus 81.9+/-15.7; P<0.01) and >35 minutes (61.8+/-18.3; P<0.01). Averaged QoL score was significantly better with the use of ACP, independently of the duration of DHCA. CONCLUSIONS: DHCA duration >20 minutes, and especially >35 minutes, adversely affects mid-term QoL in patients undergoing surgery of the thoracic aorta. The use of ACP, however, improved averaged QoL score at each time period and allows DHCA to be extended up to 30 minutes, without impairment in mid-term QoL.


Assuntos
Aorta Torácica/cirurgia , Circulação Cerebrovascular , Parada Cardíaca Induzida , Hipotermia Induzida , Perfusão/métodos , Qualidade de Vida , Atividades Cotidianas , Idoso , Transtornos Cerebrovasculares/complicações , Feminino , Seguimentos , Humanos , Hipóxia Encefálica/prevenção & controle , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Período Pós-Operatório , Papel (figurativo) , Inquéritos e Questionários , Fatores de Tempo
18.
Circulation ; 106(12 Suppl 1): I1-4, 2002 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-12354699

RESUMO

BACKGROUND: Coronary anastomoses are currently primarily carried out with the use of running nonabsorbable sutures. Recently, a renewed interest has developed for facilitated mechanical anastomotic devices especially for minimal invasive techniques or limited access surgery. The initial experience with the first successful creation of mechanical vein-to-coronary artery anastomoses in humans is reported. METHODS AND RESULTS: Between November 2000 and June 2001, 14 patients scheduled for multivessel coronary artery bypass grafting (CABG) procedure were investigated. One vein graft-to-coronary artery anastomosis per patient was performed with the St. Jude Medical ATG Symmetry coronary connector system (stainless steel investigational device, not yet commercially available). We evaluated the overall performance of the device. Intraoperative flow measurements of the grafts using transit time methods were measured. A postoperative angiographic control was performed immediately after the procedure in all patients. Hemostasis was instantaneous in all cases and all anastomoses (mechanical n=14, sutured n=40) were patent. Mean intraoperative flow measurements for the mechanical anastomosed vein grafts was 75+/-25 mL/min. Three month angiogram or MRI angiography is available to date in 11 patients. Ten connector grafts were patent and 1 was occluded. There were no cardiac-related adverse events or return of angina; exercise tolerance tests and stress electrocardiograms were normal in all patients. CONCLUSIONS: The St. Jude Medical ATG Symmetry coronary connector system is a new device for sutureless distal vein graft-to-coronary artery anastomoses in CABG. This system allows the construction of geometrically perfect anastomoses. This technology represents a further step in a new era of sutureless anastomoses in cardiac surgery.


Assuntos
Prótese Vascular , Ponte de Artéria Coronária/instrumentação , Ponte de Artéria Coronária/métodos , Vasos Coronários/cirurgia , Anastomose Cirúrgica , Angiografia Coronária , Doença das Coronárias/cirurgia , Vasos Coronários/patologia , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética
19.
Eur J Cardiothorac Surg ; 27(4): 654-7, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15784368

RESUMO

OBJECTIVES: Prompt diagnosis of subsequent dilatation of the dissected aorta is crucial to reduce late mortality in these patients. This study focuses on risk factors for dilatation of the aorta after type A aortic dissection (AADA) affecting a normal-sized or slightly dilated aorta. METHODS: Overall 531 CT scans were analysed. Patients were included in the study if at least 3 CT scans were available after operative repair. 64 patients (59.8%) out of 107 patients full-field the inclusion criteria. Volumetric analyses of the aorta were performed. Patients were divided in 3 groups: group A included 26 patients (40.6%) without progression of the aortic diameter, group 2, 27 patients (42.2%) with slight progression and group 3, 11 patients (17.2%) with important progression, requiring surgery in 9 patients (81.8%). Risk-factors for progression of the aortic size were analysed and compared between the groups. RESULTS: Patients from group 3 were younger 57.7+/-13.4 vs. 61.9+/-11.6 in group 1 (P<0.05) and were more frequent female (45.4 vs. 23.1%; P<0.05). Dissection of the supraaortic branches (100 vs. 80.8%; P<0.05), the presence of preoperative cerebral, visceral or peripheral malperfusion (54.6 vs. 26.9%; P<0.05) and contrast enhancement in the false lumen during the follow-up (72.7 vs. 57.7%; P=0.07) were additional risk factors for late aortic dilatation in these patients. CONCLUSIONS: Acute type A aortic dissection in younger patients, involving the supraaortic branches and/or combined with malperfusion syndrome favour secondary dilatation. A close follow-up is mandatory to prevent acute complications of the diseased downstream aorta following repair of a AADA.


Assuntos
Aorta/patologia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Complicações Pós-Operatórias , Adulto , Fatores Etários , Idoso , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/etiologia , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Reoperação , Fatores de Risco , Tomografia Computadorizada por Raios X
20.
Eur J Cardiothorac Surg ; 28(5): 701-4, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16221550

RESUMO

OBJECTIVE: Minimal extracorporeal circulation (mini-ECC) is a new technology, consisting of a centrifugal pump, an oxygenator, and a modified suction system. The main advantage of mini-ECC is the reduction of tubing length (reduction of the priming volume). Additional beneficial effects are a decrease of coagulation cascade and a reduction of blood transfusion in patients undergoing coronary artery bypass grafting (CABG) surgery. We compared the intraoperative and early postoperative myocardial damage and outcome of patients who underwent CABG surgery with conventional cardiopulmonary bypass (CPB) or mini-ECC. METHODS: One hundred and thirty-six consecutive patients who underwent isolated CABG surgery at our institution were prospectively studied. Fifty-four patients (39.7%) were operated with mini-ECC. Patient characteristics were similar in both groups. The most interesting intraoperative details as well as in-hospital outcome were assessed. RESULTS: There was no difference in mortality between the two groups. Cross-clamping time was similar in both groups (p = 0.07). Defibrillation was required in one patient in the mini-ECC group (1.9%) and in 38 patients (46.3%) in the CPB group (p < 0.001). In the mini-ECC group, the requirement of inotropic support and incidence of atrial fibrillation was significantly lower than in the CPB group. Postoperative creatine kinase isoenzyme MB (CK-MB) and cardiac Troponin I (cTnI) were significantly lower in the mini-ECC group (p < 0.05). Duration of ventilation, length of stay in the intensive care unit and total hospitalization time were significantly shorter in patients operated with mini-ECC (p < 0.05). CONCLUSION: Mini-ECC is a safe procedure and is followed by a diminished release of CK-MB and cTnI than after CPB. Postoperative recovery is accelerated following mini-ECC and there is a significantly lower incidence of postoperative atrial fibrillation.


Assuntos
Ponte de Artéria Coronária , Circulação Extracorpórea/métodos , Complicações Intraoperatórias , Idoso , Fibrilação Atrial/etiologia , Biomarcadores/sangue , Ponte Cardiopulmonar/efeitos adversos , Cuidados Críticos , Circulação Extracorpórea/efeitos adversos , Feminino , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Respiração Artificial , Estatísticas não Paramétricas , Fatores de Tempo , Troponina I/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA